Processor
|
Processor |
One or two Next-Generation AMD Opteron - 2000 Series dual
core processors (2220 (2.8 GHz, 95W), 2218 (2.6 GHz, 95W), 2214 (2.2
GHz, 95W), 2210 (1.8 GHz, 95W) or High Efficiency 2218 HE (2.6 GHz,
68W)) |
|
Cache |
1 MB Level 2 per core |
|
System Architecture/CPU Interconnect |
X16 HyperTransport 8 GB/s (Processor to South Bridge) X16
HyperTransport 8 GB/s (CPU-0 to CPU-1) |
|
Graphics Controller |
ASPEED AST2000 |
Main Memory
|
DIMM Slots, Memory Type |
8 DIMM slots per processor
16 DIMM slots total system Registered DDR2/667 ECC DIMMs (128 bit plus
ECC databus) |
|
Supported Max Memory Configuration |
Up to 64 GB memory supported. System configurations from
1 GB up to 64 GB. For optimal performance, install DIMMS in pairs.
¡@ |
Standard/Integrated Interfaces
|
Network |
Four Integrated 10/100/1000Base-T Ethernet ports
|
|
Management |
Service processor with embedded Lights Out Management
(LOM) standard |
|
Serial |
One Serial DB-9 Port (on rear) |
|
SATA |
Two channel SATA II interface, internal access only
|
|
USB |
Six USB 2.0 ports - two front, four rear |
|
Expansion bus |
Standard: Riser card assembly with two internal 64-bit,
8-lane, low-profile, half length PCI-Express slots |
Mass Storage and Media
|
Internal disk |
Up to two hot-pluggable 3.5" SATA II or SAS disk drives;
250 GB, 500 GB 7200 rpm SATA II or 146 GB 15K rpm SAS supported.
|
|
Removable Media |
Up to one EIDE DVD-ROM or DVD+/-RW DL drive. |
|
RAID |
RAID 0/1/0+1 with optional
4-port
SAS HBA; all supported OS with pair of SATA II or SAS drives
|
|
External disk |
See Supported Storage
|
Software
|
Operating environment |
Solaris OS, Red Hat Enterprise Linux, SUSE Linux
Enterprise Server, Microsoft Windows and VMware
See Supported
Operating Systems |
|
Languages |
C/C++, FORTRAN, Java programming language, all other
standard Sun-supported languages |
|
Networking Standards |
ONC, ONC+, NFS, WebNFS, TCP/IP, SunLink, OSI, MHS,
IPX/SPX, SMB technologies, and XML |
|
Management |
IPMI 2.0 compliant Service Processor with embedded Lights
Out Management offering remote power, KWM (keyboard, video, mouse) and
media capability |
Power
|
Quantity of Power Supplies |
Single PSU |
|
Power Supply Rating (DC Output) |
450 W |
|
Power Supply AC Input |
100-240 VAC (47-63 Hz), Auto-sensed |
|
UL Maximum (AC input) |
8A @ 100-127V; 4A @ 200-240V |
|
In Use System Power |
See the
X2200 Power
Calculator |
Dimensions and Weight
|
Height |
43 mm (1.7") |
|
Width |
425.5 mm (16.8") |
|
Depth |
633.7 mm (25") |
|
Maximum Weight |
11.60 kg (24.7 lbs) |
Documentation
|
Product Documentation |
Latest Documents
¡@
- Where to Find Sun Fire X2200 Server Documentation
- Sun Fire X2200 M2 Server Product Notes
- Sun Fire X2200 M2 Server Operating System
Installation Guide
- Embedded Lights Out Manager Administration Guide
- Sun Fire X2200 M2 Server Installation Guide
- Sun Fire X2200 M2 Server Service Manual
- Sun Fire X2200 M2 Server Safety and Compliance
Guide
|
Environment
|
Operating temperature /humidity (single, non-rack system)
|
2 ¢XC to 38 ¢XC (36¢X F to 100¢X F), 7% to 93% relative
humidity, non-condensing, 27¢X C max wet bulb |
|
Non-operating temperature/humidity (single, non-rack
system) |
-40¢X C to 68¢X C (-40¢X F to 154¢X F), up to 93% relative
humidity, non-condensing, 38¢X C max wet bulb |
|
Altitude (operating) (single, non-rack system)
|
Up to 3,000m/9000ft, maximum ambient temperature is
derated by 1¢X C per 300m above 900m |
|
Altitude (non-operating) (single, non-rack system)
|
Up to 12,000 m |
Acoustic Noise Emissions
|
Acoustic Noise Emissions |
Declared noise emissions in accordance with ISO 9296,
A-weighted, operating and idling |
|
LwAd (1B = 10dB) |
Idle, at or below 25¢X C: 6.9B
Max, at ambient: 7.2B |
|
LpAm bystander |
Idle, at or below 25C: 54.9 dBA
Max, at ambient: 58.1 dBA |
Regulations & Certifications
|
Regulations & Certifications |
Meets or exceeds the following requirements: |
|
Safety |
IEC 60950, UL/CSA60950, EN60950, CB scheme with all
country differences |
|
RFI/EMI |
FCC Class A, Part 15 47 CFR, EN55022, CISPR 22,
EN300-386:v1.31, ICES-003 |
|
Immunity |
EN55024, EN300-386:v1.3.2 |
|
Safety |
CE Mark, GOST, GS Mark, cULus Mark, CB scheme, CCC, S
Mark |
|
EMC |
CE Mark, Emissions and Immunity Class A Emissions Levels:
FCC, C-Tick, MIC, CCC, GOST, BSMI, ESTI, DOC, S Mark |
|
Other |
Labeled per WEEE (Waste Electrical and Electronic
Equipment) Directive, Reduction of Hazardous Substances Compliant
(2002/95/EC) |