­º­¶> Àx¦s³]³Æ/³Æ¥÷¤è®×

>>ÂsÄý©Ò¦³SunÀx¦s³]³Æ/³Æ¥÷¤è®×

Sun
Sun StorageTek 3510 FC Array

«¬¸¹¡GSun StorageTek 3510 FC Array


SunSun StorageTek 3510 FC Array


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºSun - Sun StorageTek 3510 FC Array - Àx¦s³]³Æ/³Æ¥÷¤è®×
³Ì¦nªºSun - Sun StorageTek 3510 FC Array±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óSun¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§Sun²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§Sun­ì¼t°t¥ó


¡@

¡@

¡@


Sun
Sun StorageTek 3510 FC Array - ServerBank¸ê°T±ÄÁʺô
Sun StorageTek 3510 FC Array
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ
µL¼ÐÃD¤å¥ó

 

 

«¬¸¹

Sun StorageTek 3510 FC Array

Specifications

-

Key Specifications
  • NEBS Level 3 certification AND MIL-STD-810F compliance
  • Up to 12 2 Gb/sec FC drives per tray
  • Up to 8 host ports
  • RAID and expansion hold up to 32.4 TB (using 300 GB drives)
Details

 

Standard Interfaces

Host interface 2 Gb Fibre Channel
Drives 3.5 in. low profile
Supported drives Dual-ported active- active 2 Gb Fibre Channel 73 GB 15K rpm; 146 GB 10K rpm, 146 GB 15K rpm, 300 GB 10K rpm, 300 GB 15K rpm
Maximum number of host ports Dual RAID controllers: 8x2 Gb Fibre Channel host ports (no expansion); 6x2 Gb Fibre Channel with expansion trays
Maximum cable length 250 m

 

FC Tray (12 HDDs) and FC RAID Array (108 HDDs) Maximum Raw Storage Capacities

73 GB 15K rpm HDDs 876 GB per 2U tray; expandable to 7.8 TB per RAID array
146 GB 10K rpm and 15K rpm HDDs 1.7 TB per 2U tray; expandable to 15.7 TB per RAID array
300 GB 10K rpm and 15K rpm HDDs 3.6 TB per 2U tray; expandable to 32.4 TB per RAID array

 

FC Tray (12 HDDs) and FC/SATA RAID Array (108 HDDs) Maximum Raw Storage Capacities

12x300 GB FC + 96x500 GB SATA
  • 51.6 TB max per RAID array. FC & SATA expansion trays may be mixed

 

RAID Controller Card

RAID configurations Expansion (no controller); single RAID controller; dual (mirrored) RAID controllers
RAID levels 0, 1, 1+0, 3, 5, 3+0, and 5+0
Max. LUNS Up to 1,024 per RAID array
Max. LUN sizes and max. number of logical drives

Firmware 4.11 and below: Max. 2 TB LUN size; 8 logical drives max.

Firmware 4.11 and above: Max. 16 TB LUN size; 32 logical drives max.
Max. local and/or global hot spares Up to 20 (RAID set and disk quantity dependent) per RAID array
Cache size (read and write) 1 GB per controller
Cache battery backup Up to 72 hours
Cache write policy Write Back¡Xdefault; Write Through¡Xuser configurable
Cache selectable block sizes 32K (random file transfer); 128K (sequential file transfer)
Included Management software Sun StorageTek Configuration Service software; Sun StorageTek support Diagnostic Reporter software
Optional supported software Sun StorageTek Enterprise Storage Manager, Sun StorageTek Traffic Manager, Sun Cluster 3, VERITAS NetBackup and VERITAS Volume Manager including DMP, Sun Logical Volume Manager for the Solaris 9 Operating System, Sun Solstice DiskSuite for the Solaris 8 Operating System, Sun StorageTek Resource Management, Sun StorageTek Utilization, and Sun StorageTek Performance Suites

 

Supported Host Platforms

Supported Host Servers All Sun Enterprise, Netra, and Sun Fire SPARC-based and Sun Fire x86-based servers; x86-based (Intel and AMD) third-party servers; IBM RISC-based servers; HP RISC-based servers
Supported host bus adapters
  • Sun Solaris (8, 9, 10): X6727A, X6767A, X6768A, SG-XPCI1FC-QF2, SG-XPCI2FC-QF2, SG-XPCI1FC-JF2, SG-XPCI2FC-JF2
  • Sun Solaris x86 10: X9279A (Sun Fire V20z and V40z servers)
  • MS Windows/Red Hat Linux/Novell SuSE Linux/Novell Netware: QLA23XX 2 Gb FC PCI*
  • HP-UX 11.0 and 11i: Emulex LP9XXX 2 Gb FC PCI* and compatible
  • IBM-AIX 4.3.3 and 5.1L (32 and 64 bit): Emulex LP9XXX 2 Gb FC PCI* and compatible
*Note: All non-Sun host bus adapters supported by third-party vendor

 

Reliability, Availability, Serviceability (RAS)

RAS
  • Non-disruptive controller firmware upgrades using dual RAID controllers via SSCS
  • Hot-swap RAID controllers with battery-backed mirrored 1 GB cache, (with dual RAID controllers)
  • Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
  • Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
  • Hot-swap, redundant electrically-isolated redundant cooling fans
  • Local and global hot sparing

 

Electrical Requirements

Wattage 420W each (Dual Hot-Swap Redundant Power Supplies)
AC Voltage 100 to 240 VAC, single phase
AC Power requirement 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)
AC Current per input 100 to 240 VAC, 50 to 60 Hz, 5.0¡V7.1A
DC Voltage ¡V48 or ¡V60 VDC, 18A
DC Power requirement ¡V36 to ¡V75 VDC
DC Current per input ¡V48 or ¡V60 VDC, 18A

 

Environment

Temperature
  • Operating: 5¢XC to 40¢XC (41¢XF to 104¢XF)
  • Non-operating: ¡V40¢XC to 65¢XC (¡V40¢XF to 149¢XF)
Humidity (non-condensing)
  • Operating: 10% to 90% relative to 38¢XC
  • Non-operating: 0% to 90% relative to 27¢XC
Altitude
  • Operating: ¡V30 m to 3048 m (¡V100 to 10,000 ft.)
  • Non-operating: ¡V30 m to 12,192 m (¡V100 to 40,000 ft.)
Shock
  • Operating: 5.0 G, 11-ms, half-sine
  • Non-operating: 15.0 G, 11-ms, half-sine
Vibration
  • Operating: 0.2 G, 5¡V500 Hz, swept-sine
  • Non-operating: 1.0 G, 5¡V500 Hz, swept-sine
Noise *
  • Operating: LWAD = 6.6 bels
*LWAD (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23¢XC.

 

Regulations - Meets or exceeds the following requirements:

Safety UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003
Emissions VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark
Harmonics IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001
Immunity CSIPR 24 EN 55024
Ruggedized NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386
Restriction of Hazardous Substances European Union (EU) Directive 2002/95/EC, invoking the lead-in-solder exemption, Article 4(1) paragraph 7.

 

Dimensions and Weight

Dimensions (Height, Width, Depth) H: 8.8 cm (3.5 in.; 2U); W: 44.7 cm (17.6 in.); D: 53.3 cm (21 in.)
Weight (Fully Populated) 22.7 kg (50 lb.)

 

Warranty

Two year Sun two-year standard warranty, (1st year on site, 2nd year return to depot)
Service upgrades SunSpectrum service upgrades are available

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºSun - Sun StorageTek 3510 FC Array - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºSun - Sun StorageTek 3510 FC Array±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 NASºô¸ôÀx¦sÀɮצøªA¾¹
 ServerBank±ÀÂ˾÷ºØ
 ®à¤W«¬
 ¾÷¬[¦¡
 ª½¥ß¦¡
 ºÏºÐ°}¦C°t¥ó
 ¦Û°Ê¥úºÐ«þ¨©¾÷
 ¥~±µ¦¡µwºÐ
 ºÏ±a¾÷
 SDLT
 DLT
 LTO 1/2/3/4
 Ultrium I
 Ultrium II
 SAIT
 AIT
 AIT Turbo
 DAT
 DDS
 ºÏ±a´«±a¾÷Autoloader
 iSCSI¸Ñ¨M¤è®×
 iSCSIºÏºÐ°}¦C
 iSCSI¾ô±µ¾¹
 ºÏºÐ°}¦CRAID
 ServerBank±ÀÂ˾÷ºØ
 iSCSI
 iSCSI to SAS
 SATA
 SCSI-to-SCSI
 SCSI-to-IDE
 SCSI-to-SATA
 Fibre-to-SCSI
 Fibre-to-IDE
 Fibre-to-SATA
 Fibre-to-Fibre
 Fibre to SAS
 USB-to-IDE
 SATA-to-SATA
 SATA-to-IDE
 SAS
 IDE-to-IDE
 1394-to-IDE
 JBOD
 ºÏºÐ°}¦CÂd
 1394B-to-SATAII
 1394B-to PATA
 °ïÅ|¦¡Àx¦s¥~±µ²°
 SAS-to-SATA
 SAS-to-SAS
 SCSI-to-SAS
 PCIE
 USB
 IDE
 SAN¸Ñ¨M¤è®×
 ¥úÅÖ³q¹D¥æ´«¾¹
 ¥úÅÖ³q¹D¤¶­±¥d
 SAN Storage
 SAN Software
 ¥úÅÖ³q¹D¾ô±µ¾¹
 ¾É¦V¾¹director
 ¥úÅÖ¼Ò²Õ
 Àx¦sºÞ²z³nÅé
 ºÏ±aÂd
 ºÏ±a
 ¦Û°Ê´«¤ù¥úºÐ
 ÂÅ¥ú¥úºÐÂd
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > Àx¦s³]³Æ/³Æ¥÷¤è®×


SunSun StorageTek 3510 FC Array

Sun StorageTek 3510 FC Array


¼tµP¡GSun      >>ÂsÄýSun¥þ³¡²£«~
«¬¸¹¡GSun StorageTek 3510 FC Array



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºSun - Sun StorageTek 3510 FC Array - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºSun - Sun StorageTek 3510 FC Array±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óSun¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§Sun²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§Sun­ì¼t°t¥ó


¡@

¡@

¡@


Sun
Sun StorageTek 3510 FC Array - ServerBank¸ê°T±ÄÁʺô
Sun StorageTek 3510 FC Array
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ
µL¼ÐÃD¤å¥ó

 

 

«¬¸¹

Sun StorageTek 3510 FC Array

Specifications

-

Key Specifications
  • NEBS Level 3 certification AND MIL-STD-810F compliance
  • Up to 12 2 Gb/sec FC drives per tray
  • Up to 8 host ports
  • RAID and expansion hold up to 32.4 TB (using 300 GB drives)
Details

 

Standard Interfaces

Host interface 2 Gb Fibre Channel
Drives 3.5 in. low profile
Supported drives Dual-ported active- active 2 Gb Fibre Channel 73 GB 15K rpm; 146 GB 10K rpm, 146 GB 15K rpm, 300 GB 10K rpm, 300 GB 15K rpm
Maximum number of host ports Dual RAID controllers: 8x2 Gb Fibre Channel host ports (no expansion); 6x2 Gb Fibre Channel with expansion trays
Maximum cable length 250 m

 

FC Tray (12 HDDs) and FC RAID Array (108 HDDs) Maximum Raw Storage Capacities

73 GB 15K rpm HDDs 876 GB per 2U tray; expandable to 7.8 TB per RAID array
146 GB 10K rpm and 15K rpm HDDs 1.7 TB per 2U tray; expandable to 15.7 TB per RAID array
300 GB 10K rpm and 15K rpm HDDs 3.6 TB per 2U tray; expandable to 32.4 TB per RAID array

 

FC Tray (12 HDDs) and FC/SATA RAID Array (108 HDDs) Maximum Raw Storage Capacities

12x300 GB FC + 96x500 GB SATA
  • 51.6 TB max per RAID array. FC & SATA expansion trays may be mixed

 

RAID Controller Card

RAID configurations Expansion (no controller); single RAID controller; dual (mirrored) RAID controllers
RAID levels 0, 1, 1+0, 3, 5, 3+0, and 5+0
Max. LUNS Up to 1,024 per RAID array
Max. LUN sizes and max. number of logical drives

Firmware 4.11 and below: Max. 2 TB LUN size; 8 logical drives max.

Firmware 4.11 and above: Max. 16 TB LUN size; 32 logical drives max.
Max. local and/or global hot spares Up to 20 (RAID set and disk quantity dependent) per RAID array
Cache size (read and write) 1 GB per controller
Cache battery backup Up to 72 hours
Cache write policy Write Back¡Xdefault; Write Through¡Xuser configurable
Cache selectable block sizes 32K (random file transfer); 128K (sequential file transfer)
Included Management software Sun StorageTek Configuration Service software; Sun StorageTek support Diagnostic Reporter software
Optional supported software Sun StorageTek Enterprise Storage Manager, Sun StorageTek Traffic Manager, Sun Cluster 3, VERITAS NetBackup and VERITAS Volume Manager including DMP, Sun Logical Volume Manager for the Solaris 9 Operating System, Sun Solstice DiskSuite for the Solaris 8 Operating System, Sun StorageTek Resource Management, Sun StorageTek Utilization, and Sun StorageTek Performance Suites

 

Supported Host Platforms

Supported Host Servers All Sun Enterprise, Netra, and Sun Fire SPARC-based and Sun Fire x86-based servers; x86-based (Intel and AMD) third-party servers; IBM RISC-based servers; HP RISC-based servers
Supported host bus adapters
  • Sun Solaris (8, 9, 10): X6727A, X6767A, X6768A, SG-XPCI1FC-QF2, SG-XPCI2FC-QF2, SG-XPCI1FC-JF2, SG-XPCI2FC-JF2
  • Sun Solaris x86 10: X9279A (Sun Fire V20z and V40z servers)
  • MS Windows/Red Hat Linux/Novell SuSE Linux/Novell Netware: QLA23XX 2 Gb FC PCI*
  • HP-UX 11.0 and 11i: Emulex LP9XXX 2 Gb FC PCI* and compatible
  • IBM-AIX 4.3.3 and 5.1L (32 and 64 bit): Emulex LP9XXX 2 Gb FC PCI* and compatible
*Note: All non-Sun host bus adapters supported by third-party vendor

 

Reliability, Availability, Serviceability (RAS)

RAS
  • Non-disruptive controller firmware upgrades using dual RAID controllers via SSCS
  • Hot-swap RAID controllers with battery-backed mirrored 1 GB cache, (with dual RAID controllers)
  • Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
  • Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
  • Hot-swap, redundant electrically-isolated redundant cooling fans
  • Local and global hot sparing

 

Electrical Requirements

Wattage 420W each (Dual Hot-Swap Redundant Power Supplies)
AC Voltage 100 to 240 VAC, single phase
AC Power requirement 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)
AC Current per input 100 to 240 VAC, 50 to 60 Hz, 5.0¡V7.1A
DC Voltage ¡V48 or ¡V60 VDC, 18A
DC Power requirement ¡V36 to ¡V75 VDC
DC Current per input ¡V48 or ¡V60 VDC, 18A

 

Environment

Temperature
  • Operating: 5¢XC to 40¢XC (41¢XF to 104¢XF)
  • Non-operating: ¡V40¢XC to 65¢XC (¡V40¢XF to 149¢XF)
Humidity (non-condensing)
  • Operating: 10% to 90% relative to 38¢XC
  • Non-operating: 0% to 90% relative to 27¢XC
Altitude
  • Operating: ¡V30 m to 3048 m (¡V100 to 10,000 ft.)
  • Non-operating: ¡V30 m to 12,192 m (¡V100 to 40,000 ft.)
Shock
  • Operating: 5.0 G, 11-ms, half-sine
  • Non-operating: 15.0 G, 11-ms, half-sine
Vibration
  • Operating: 0.2 G, 5¡V500 Hz, swept-sine
  • Non-operating: 1.0 G, 5¡V500 Hz, swept-sine
Noise *
  • Operating: LWAD = 6.6 bels
*LWAD (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23¢XC.

 

Regulations - Meets or exceeds the following requirements:

Safety UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003
Emissions VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark
Harmonics IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001
Immunity CSIPR 24 EN 55024
Ruggedized NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386
Restriction of Hazardous Substances European Union (EU) Directive 2002/95/EC, invoking the lead-in-solder exemption, Article 4(1) paragraph 7.

 

Dimensions and Weight

Dimensions (Height, Width, Depth) H: 8.8 cm (3.5 in.; 2U); W: 44.7 cm (17.6 in.); D: 53.3 cm (21 in.)
Weight (Fully Populated) 22.7 kg (50 lb.)

 

Warranty

Two year Sun two-year standard warranty, (1st year on site, 2nd year return to depot)
Service upgrades SunSpectrum service upgrades are available

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºSun - Sun StorageTek 3510 FC Array - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºSun - Sun StorageTek 3510 FC Array±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@