­º­¶> Àx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦CRAID>Fibre-to-SATA

>>ÂsÄý©Ò¦³Promise³ì¹©Àx¦s³]³Æ/³Æ¥÷¤è®×>

Promise³ì¹©
Promise³ì¹©FC SAN (4Gb¥úÅÖ³q¹DRAID)(VTE310fS)

«¬¸¹¡GVTE310fS


Promise³ì¹©VTE310fS


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºPromise³ì¹© - VTE310fS - Àx¦s³]³Æ/³Æ¥÷¤è®×>
³Ì¦nªºPromise³ì¹© - Promise³ì¹©FC SAN (4Gb¥úÅÖ³q¹DRAID)(VTE310fS)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦CRAID>Fibre-to-SATA Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óPromise³ì¹©¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§Promise³ì¹©²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§Promise³ì¹©­ì¼t°t¥ó


¡@

¡@

¡@

ùþ²¤¶


ùþ²¤¶

°w¹ï¥ø·~¯Å»Pªñ½u( nearline )À³¥Î¡A¥H³Ì¤jªºÂX¥R©Ê¤Î©µ®i©Ê¡A½á¤©°ª«×ªº¥i¥Î©Ê©M®Ä¯à

VTrak E310f²£«~µJÂI 

RAID±±¨î¾¹¤ä´©¬G»Ù´_­ì( failover) ¡þ¬G»Ù¦^´_( failback )¡A´£¨Ñ°ª«×¥i¥Î©Ê¡C

°í¹êªº2U ¾÷½c¤¤«Ø¦³12­Ó¤ä´©¼ö´¡©ÞªºµwºÐ¼Ñ¡C

´£¨Ñ¥i¦P®É¨Ï¥ÎSAS»PSATA 3Gb/s µwºÐªº¼u©Ê¡C

¨C­Ó±±¨î¾¹´£¨ÑÂù4Gb FC¥D¾÷¤¶­±°ð¡A¨ã³Æ®Ä¯à¤Î³sµ²¯à¤O¡C

RAID 0/ 1/ 1E / 10/ 5/ 6 / 50 /60ªº¸ê®Æ«OÅ@±¹©ì¡A¤ä´©¦h­Ó¥þ°ì©Î±M¥Îªº¼ö³Æ´©µwºÐ (multiple global or dedicated hot-spare drives support)¡C

JBODÂX¥R ¡Ð ³Ì°ª¥i³s±µ¥|­ÓVTrak J-Class JBOD ¨t²Î¡CJBOD expansion - up to 4 VTrak J-Class JBOD systems

³Æ´©ªº¼ö´¡©Þ¹q·½¤Î§N«o¼Ò²Õ¡C

´O¤J¦¡ºô­¶ºÞ²zGUI¡A¥i³z¹LRJ-11§Ç¦C°ð¨Ï¥Î¤A¤Óºô¸ô¤Î©R¥O¦C¤¶­±¡þ¤u¨ã¡C

LUN¹ï¬M (mapping) ¤Î¾B¸n (masking)¡A¥i³]©wSAN¤Î¤j«¬ÂO¶°¡C

PerfectRAIDR»PPredictive Data MigrationR§Þ³N¡A´£¨Ñ°í¹êªº¿ù»~³B²z¤Î´_­ì¥\¯à¡C

µ´¨Îªº¤ä´©¤è®×¡A¥]¬A24 X 7ªº¤ä´©¡]¶È´£¨Ñ­^»yªA°È¡^¤Î¹w¥ý§ó´«­pµe¡C 

¬°¦Ò¶q¤¤¤p¥ø·~¯à­t¾áªº»ù®æ¡A«o¥i¨Ï¥Î¤j«¬¥ø·~µ¥¯Åªº¥\¯à¡A³ì¹©VTrak E-Class±q±ÄÁÊ¡B¦w¸Ë¾Þ§@³]©w©M¤É¯Å¤è­±¡A³£¹ý©³§ïÅÜÀx¦s¸gÀٮįq¡F¨Ï¥ÎSerial Attached SCSI¡]SAS¡^»PSerial ATA¡]SATA¡^µwºÐªº¼u©Ê¡A¥[¤WVTrak E-Classªº¶}©ñ¬[ºc¡A¨Ï¥ø·~¯à¹B¥Î³Ì¾A¦X¨äÀ³¥Î»Ý¨Dªº¤¸¥ó¡C©Ò¦³E-Class¨t¦C²£«~¨Ï¥Î¬Û¦Pªº¶´Åé¡A©ö©ó¶i¦æ³W®æ¼f®Ö§@·~¡C³ì¹©ªºWebPAMR PROe´£¨Ñ¤@®M¿W¥ß©ó§@·~¨t²Îªº¶°¤¤¦¡GUI¡A´£¨Ñ¥þ­±©Êªº¸ê®ÆºÞ²z¯à¤O¡C³ì¹©§ó¥H24 X 7ªº§Þ³N¤ä´©¡B¤T¦~¦³­­«O©T¤Î¹w¥ý§ó´«­pµe¡A¤ä´©©Ò¦³ªºVTrak²£«~¡C 

´¼¼z«¬³]­p´£¨Ñ©µ®i©Ê¤Î¤É¯Å©Ê
¨C­Ó±±¨î¾¹¤W¦³Âù4Gb¥úÅÖ³q¹D¡]FC¡^¥D¾÷¤¶­±°ð¡A¥i³s±µ¦Ü¼sªx³¡¸pªº¥úÅÖ³q¹DÀx¦sºô¸ô¡A¾A¦X©ó¸É¥R²{¦³Àx¦sºô¸ô¤Î«Ø¥ß·sªºÀ³¥Îµ{¦¡Àx¦s¨t²Î¡C¿ï¾Ü²Å¦X¥Ø«e»Ý¨DªºE-Class¨t²Î¡A§Y¾Ö¦³¥u­nÅܧ󱱨´N¯à§ó´«¥D¾÷¤¶­±ªº¼u©Ê¡A¨Ã¥B¥i±NVTrak J-Class¥[¤JJBOD¨t²Î¡A¼W¥[¥i¥ÎªºÀx¦s³]³Æ¡A¥Hº¡¨¬¥¼¨Óªº»Ý¨D¡C¦¹¥~¡A¦bVTrak E-Class»PJ-Class¤¤¹ê¬ISAS§Þ³Nªº¥D­nÀu¶Õ¤§¤@¡A§Y¬O¯à¥H¬Û¦Pªº¤¶­±³s±µSAS©ÎSATAµwºÐ¡C³o¨Ï¥ø·~¯à¦b­«­n°Ó·~¥æ©ö¼W¥[®É¡A«K©óÂX¥RSASÀx¦s³]³Æ¡A¨Ã±N¸û¤Ö¦s¨úªº¸ê®Æ²¾Âà¨ìSATAÀx¦s³]³Æ¤W¡A²¤Æ¸ê®ÆºÞ²zªº§@·~¡C¥t¥~¡A²£«~¤§¶¡¨Ï¥Î¬Û¦PªºFRUs¡A¥ç¯à´î¤Ö³Æ¥Î¹s¥óªºSKUs©M²¤Æ²{³õªº§ó´«§@·~¡C 

µL³æÂI¥¢®Ä
³ì¹©ªºVTrak E310f¤j´TÁY¤p²³æ®e¿ù (simple fault tolerance)¡A»PµL³æÂI¥¢®Ä (No Single Point of Failure) ¤§¶¡ªº®t¶Z¡CE310f¾ã¦X¤@¶µ´¼¼z«¬¡B¥ø·~¯ÅªºµLÆl½u¨t²Î³]­p (cable-less system design)¡A¨ä¤¤¥]¬A§¹¾ã³Æ´©¡B¼ö´¡©Þ±±¨î¾¹¡B¹q·½¤Î§N«o¸Ë¸m¡A³o¨Ç¬Ò¥i¶i¦æ²{³õ§ó´«¡A¨Ã¥B«ùÄòºÊ±±©Ò¦³¨t²Î¤¸¥ó¡A½T«O«ùÄò¹B§@¡A¥HÁקKµo¥ÍºÏºÐ¡B±±¨î¾¹¡B¹q·½¨ÑÀ³¾¹©Î¬O§N«o¸Ë¸m¬G»Ùªº±¡ªp¡CÂù­«active-active¡B¬G»Ù´_­ì¡þ¬G»Ù¦^´_RAID ±±¨î¾¹¡A´£¨Ñ³Æ´©¸ê®Æ¸ô®| (redundant data paths)¡A¶i¤@¨B½T«O¤F¥i¥Î©Ê¡C

§¹¾ãªº¸ê®ÆºÞ²z¥\¯à
VTrak E310f·f°t¤@®M´O¤J¦¡ºÞ²z³nÅéWebPAM PROe¡A±Æ°£¦bºô¸ô¤W¦w¸ËÃB¥~³nÅ骺»Ý¨D¡C¥i³z¹L³æ¤@¡B©ö©óºÞ²zªººô­¶¹Ï§Î¨Ï¥ÎªÌ¤¶­±¡A³]©w©MºÊ±±ºô¸ô¸Ì©Ò¦³VTrak¨t²Î¡A¦Ó³nÅé³z¹LVTrak¨t²Îªº¤A¤Óºô¸ô°ð¡]¦b¥»¾÷ºÝ¡B¸g¹LLAN©Î¬Oºô»Úºô¸ô³s½u¡^¶i¦æ¹B§@¡A¥H³]©w©MºÊ±±¤@­Ó©Î¦h­ÓVTrak¨t²Î¡A¨Ã¥BÂǥѼu¥X°T®§¡B¨Æ¥ó¤é»x©Î¬O¹q¤l¶l¥ó³qª¾´£¨Ñ¿ù»~¦^³ø¡Cµo¥Í±±¨î¾¹¬G»Ù®É¡A³ì¹©ªººÞ²z³nÅé¥ç·|¶i¦æ§¹µ½ªº¬G»Ù´_­ì©M¬G»Ù¦^´_§@·~¡CVTrak¨t¦C²£«~¤]¥i¹B¥Î¤u·~¼Ð·ÇªºSNMP©MCIM¨ó©w¡A²¤Æ»P²Ä¤TªÌºÞ²zÀ³¥Îµ{¦¡ªº¾ã¦X§@·~¡C


¡@


Promise³ì¹©
Promise³ì¹©FC SAN (4Gb¥úÅÖ³q¹DRAID)(VTE310fS) - ServerBank¸ê°T±ÄÁʺô
VTE310fS
Àx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦CRAID>Fibre-to-SATA


¡@
²£«~³W®æ
E-Class 3U/FC ³W ®æ

VTrak E310f³W ®æ

¨t²Î»PºÏºÐ°}¦C¥d¯S¦â
ºÏºÐ°}¦C¥d

Âù­«ºÏºÐ°}¦C¥d²ÕºA(E310f¡ÐÂù­«)/³æ¤@ºÏºÐ°}¦C¥d²ÕºA¡A¥i¤É¯Å(E310f¡Ð³æ¤@)

¦Û°Ê¬G»Ù´_­ì/¦Û°Ê«ì´_RAIDºÏºÐ°}¦C¥d¡FActive/Active with LUN Affinity* or Active/Standby

¤ä´©µwºÐ

³Ì¦h12²Õ3.5¦T x 1¦TªºµwºÐ¡GSAS 3Gb/s¡BSATA II 3Gb/s»P1.5Gb/s -- ³æ¤@I/OºÏºÐ°}¦C¥d²ÕºAªºª½±µ³sµ²©Î¬O¨Ï¥Î³ì¹©SATA MUXÂà´«¥dªºÂù­«I/OºÏºÐ°}¦C¥d²ÕºA¡F¥æ¿ù¦¡¹êÅéµwºÐ±Ò°Ê¤ä´©¦b¦P¤@¨t²Î¤¤¥ô¦ó¦P®É²V·fªºSAS 3Gb/s¡BSATA II 3Gb/s»P1.5Gb/sµwºÐ¡F¥ç¤ä´©ª½±µSATA LED

¥~±µI/O°ð(¨C¤@ºÏºÐ°}¦C¥d)

Âù­«4 Gb¥úÅÖ³q¹D¥D¾÷°ð - ¦^·¹¬Û®e©ó2 Gb»P1 Gb FC HBA¡F³æ¤@¥~±µ3Gb/s SAS x4°ðªºJBODÂX¥R(³Ì¦h4²ÕVTrakJ-Class JBOD¨t²Î)

¸ê®Æ§Ö¨ú

Ãè¹³»P¦@¥Îªº512 MB¹w´ú¦¡¸ê®Æ§Ö¨ú(³Ì¦h¥i¹F2 GB - ½Ð¦V³ì¹©­qÁÊ)¡F¦Û°Ê¼g¤J§Ö¨ú­°¶¥(de-staging)¡F512 MB¦³72¤p®Éªº¹q¦À³Æ´©

«ü¥O¦î¦C²`«× ¨C­ÓVTrakºÏºÐ°}¦C¥d512­Ó«ü¥O
¾Þ§@¥\¯à
RAID¼h¯Å RAID 0¡B1¡B1E¡B5¡B6¡B10¡B50¡B60 - ¥ô¦ó¤W­zRAID¼h¯Åªº²Õ¦X§¡¥i¦P®É¨Ã¦s
RAID¼u©Ê

¥i³]©wRAIDªº±ø±a(stripe)¤j¤p¡G¨CÁûµwºÐ64 K¡B128 K¡B256 K¡B512 K¤Î1 MBªº±ø±a(stripe)¤j¤p

­I´º§@·~Àu¥ý«×½Õ¸`¡G¦b©Ò¦³­I´º§@·~®É½Õ¸`³Ì¤pI/O«O¯dµ¹¦øªA¾¹¨Ï¥Î

§Y®É³Æ¥ó ¥i«ü©w¦h­Ó©Î±MÄݪº§Y®É³Æ¥óµwºÐ¤ÎÁÙ­ì¿ï¶µ
¨C­Ó¤l¨t²Îªº³Ì¤jLUN¼Æ¥Ø ¥ô¦óRAID¼h¯Å¤ÎÃþ«¬²Õ¦X¤U§¡¬°256
¨C­Ó°}¦Cªº³Ì¤jÅÞ¿èµwºÐ¼Æ¥Ø

32­ÓÅÞ¿èµwºÐ(LUN)¡F¥i±N³æ¤@°}¦C¤À³Î¦¨¼Æ­ÓÅÞ¿èµwºÐ¥H¤ä´©LUN¹º¤À¡A¨C­ÓLUNªºRAID¼h¯Å¡B±ø±a¤j¤p¡BºÏ°Ï¤j¤p¡B¥H¤Î§Ö¨ú¤è¦¡³£¥i¦Û­q¡C¤ä´©µL§Ç¦¡ÅÞ¿èµwºÐ§R°£»P­«»s

¨C­Ó¥Ø¼ÐIDªº³Ì¤jLUN¼Æ¥Ø ³Ì¦h256
LUN¾B¸n»P¹ïÀ³ ¤ä´©³Ì¦h128­Ó¥HFC WWPN¬°°ò¦ªº ±Ò°Ê¾¹
µwºÐ¸ê®Æ®æ¦¡ ¤ä´©·~¬É¼Ð·ÇªºµwºÐ¸ê®Æ®æ¦¡(DDF)»PVTrak¨t²Î¶¡ªºµwºÐº©¹C
­I´º°Ê§@

´CÅ騵µø¡F­I´º¦P¨B¡F«e´º±Ò°Ê¡F­««Ø¡F³Æ´©Àˬd¡FSMARTª¬ºA¦@¥Î¡F

OCE (½u¤W®e¶qÂX¥R)¡FRLM (RAID¼h¯ÅÂಾ)¡F

Àu¥ý«×±±¨î¡B³t²v±±¨î¥H¤ÎµwºÐ©MNVRAM¨C­ÓBGAªº¯B¤ô¦L

PerfectRAID

¸ê®Æ¥¿½T©Ê¥\¯à

¹êÅéµwºÐ¿ù»~ÁÙ­ì¡GPDM (¹w´ú¦¡¸ê®ÆÂಾ)¡G§ó´«°}¦C¤¤¦³°ÝÃDªºµwºÐ¡A¨Ã¦b¨ä¥L¥¿±`µwºÐ±N¸ê®Æ­««Ø¦Ü·sµwºÐ®É«O«ù°}¦Cª¬ºA¥¿±`¡AÃa­y¹ïÀ³¡B´CÅ騵µø¡BSMART¡Bµw¦¡/³n¦¡­«³]¥H«K­×´_HD¬G»Ùª¬ºA¡BHD¹q·½±±¨î¥H«K­×´_HD°±º¢ª¬ºA¡C°}¦C¿ù»~­×´_¡G³z¹L³Æ´©RAID¡BRAID 5/6¤£¤@­P¸ê®Æ¨¾½d(Write Hole Table)¡B¸ê®Æ¤º®e¿ù»~¨¾½d(Ū/¼gÀˬdªí) NVRAM¨Æ¥ó¬ö¿ý¡A±qÃa­y©Î¬O¬G»ÙHDÁÙ­ì¸ê®Æ

SCSI«ü¥O

¤ä´©»PSCSI/FCµwºÐ¾÷µ¥®Ä¤§ÂX¥R¦¡SCSI«ü¥O¶°¡F¥H¥iÅܦ¡ºÏ°Ï¤j¤p(±q512 Byte¨ì4 kB)¥´¯}¶Ç²Î­­¨î¡F16 Byte CDB¤ä´©64¦ì¤¸ªºLBA©w§}

¨t²ÎºÞ²z

¤ä´©ªº§@·~¨t²Î

Windows 2000, Windows 2003, Vista/Windows 2008, Linux (Red Hat, SuSE)

¦h­«¸ô®|I/O¤ä´© PerfectPath? Manager¡Ð¨Ï¥Î·L³nªºMPIO¬[ºc(¥u­­Windows)
ºÞ²z¤u¨ã

»P§@·~¨t²ÎµLÃö¡F¨ã³Æ¦hºØ¥»¤g¤Æ»y¨¥¡F¤ä´©SSL¦w¥þ©Ê¡FWebPAM PROe¡F¨Ï¥Î¤A¤Óºô¸ô°ðªººô­¶¦¡GUI¡F«ü¥O¦C¤¶­±»P¨Ï¥ÎRJ-11¦ê¦C°ð©Î¤A¤Óºô¸ô(Telnet)ªº¤u¨ã¡F¦Û°Ê¡B§Ö³t»P¶i¶¥²ÕºA¤ä´©¡A¤À§O¾A¥Î©ó¤Jªù©Î¦³¸gÅ窺¥Î¤á¡C¦bºÞ²z¤A¤Óºô¸ô¨B¶i¦æµLÁ_¦¡³nÅé¬G»Ù´_­ì»P¦Û°Ê«ì´_

ºÞ²z¤¶­±/¨ó©w ´O¤J¦¡ºô­¶¦øªA¾¹»PºÞ²z¤ä´© - ¤ð¶·¨Ï¥Î¥D¾÷¥N²zµ{¦¡¡F¤A¤Óºô¸ô¡BRJ-11¦ê¦C°ð¡FCIM/WBEM¡BSNMP¡BSSL¡BSLP¡BTelnet
¨Æ¥ó´£¥Ü ¹q¤l¶l¥ó¡BNETSEND¡F­µ®Ä(¸Á»ï)¡B¥H¤Î¥iµø(LED)ĵ°T
¾÷±ñ³W®æ

¹qÀ£

¥æ¬y100¦Ü240¥ñ¯S¦Û°Ê½Õ¸`

¹q¬y(¤W­­)

8¦w°ö@100¥ñ¯S¥æ¬y¡F4¦w°ö@200¥ñ¯S¥æ¬y(¹q¬yÃB©w¨Ï¥Î¨â±ø¹q·½½u)

ÀW²v 50¦Ü60 Hz

¹q·½

Âù­«400¥Ë¡BÂù­«¼ö©â´«ªº³Æ´©PFC¡BN+1³]­p

¸`¬ù¥\²v

141.68¥Ë(µLHDD­t¸ü®É)¡B452.68¥Ë(¦³SAS HDD­t¸ü®É)

¾Þ§@·Å«×/·Ã«×

Äá¤ó5«×~40«×(¤£¾Þ§@®É¬°Äá¤ó¹s¤U40«×~Äá¤ó60«×)

¬Û¹ï·Ã«× ³Ì°ª95%

¾_°Ê

ÀH¾÷¡A0.21 grms¡A5¦Ü500 Hz¡AX¡BY¡BZ¶b

¤Ø¤o(°ªx¼ex²`)

8.8 x 44.4 x 56.1¤½¤À(3.5 x 17.5 x 22.1¦T)

­«¶q

*°²³]¨CÁûµwºÐ­«¶q= 0.5¤½¤ç

²b­«(¥u­­¨t²Î)¡GµLµwºÐ®É26¤½¤ç(57½S)¡A¦w¸Ë12ÁûµwºÐ®É 32¤½¤ç(71½S)**

¤ò­«(§t¯È½c)¡G¤£§tµwºÐ®É29¤½¤ç(64½S)

¦w¥þ©Ê CE¡BFCC Class A¡BVCCI¡BC-Tick¡BcUL¡BTUV¡BCB¡BBSMI

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºPromise³ì¹© - VTE310fS - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºPromise³ì¹© - Promise³ì¹©FC SAN (4Gb¥úÅÖ³q¹DRAID)(VTE310fS)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 NASºô¸ôÀx¦sÀɮצøªA¾¹
 ServerBank±ÀÂ˾÷ºØ
 ®à¤W«¬
 ¾÷¬[¦¡
 ª½¥ß¦¡
 ºÏºÐ°}¦C°t¥ó
 ¦Û°Ê¥úºÐ«þ¨©¾÷
 ¥~±µ¦¡µwºÐ
 ºÏ±a¾÷
 SDLT
 DLT
 LTO 1/2/3/4
 Ultrium I
 Ultrium II
 SAIT
 AIT
 AIT Turbo
 DAT
 DDS
 ºÏ±a´«±a¾÷Autoloader
 iSCSI¸Ñ¨M¤è®×
 iSCSIºÏºÐ°}¦C
 iSCSI¾ô±µ¾¹
 ºÏºÐ°}¦CRAID
 ServerBank±ÀÂ˾÷ºØ
 iSCSI
 iSCSI to SAS
 SATA
 SCSI-to-SCSI
 SCSI-to-IDE
 SCSI-to-SATA
 Fibre-to-SCSI
 Fibre-to-IDE
 Fibre-to-SATA
 Fibre-to-Fibre
 Fibre to SAS
 USB-to-IDE
 SATA-to-SATA
 SATA-to-IDE
 SAS
 IDE-to-IDE
 1394-to-IDE
 JBOD
 ºÏºÐ°}¦CÂd
 1394B-to-SATAII
 1394B-to PATA
 °ïÅ|¦¡Àx¦s¥~±µ²°
 SAS-to-SATA
 SAS-to-SAS
 SCSI-to-SAS
 PCIE
 USB
 IDE
 SAN¸Ñ¨M¤è®×
 ¥úÅÖ³q¹D¥æ´«¾¹
 ¥úÅÖ³q¹D¤¶­±¥d
 SAN Storage
 SAN Software
 ¥úÅÖ³q¹D¾ô±µ¾¹
 ¾É¦V¾¹director
 ¥úÅÖ¼Ò²Õ
 Àx¦sºÞ²z³nÅé
 ºÏ±aÂd
 ºÏ±a
 ¦Û°Ê´«¤ù¥úºÐ
 ÂÅ¥ú¥úºÐÂd
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > Àx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦CRAID>Fibre-to-SATA


Promise³ì¹©VTE310fS

Promise³ì¹©FC SAN (4Gb¥úÅÖ³q¹DRAID)(VTE310fS)


¼tµP¡GPromise³ì¹©      >>ÂsÄýPromise³ì¹©¥þ³¡²£«~
«¬¸¹¡GVTE310fS



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºPromise³ì¹© - VTE310fS - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºPromise³ì¹© - Promise³ì¹©FC SAN (4Gb¥úÅÖ³q¹DRAID)(VTE310fS)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦CRAID>Fibre-to-SATA Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óPromise³ì¹©¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§Promise³ì¹©²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§Promise³ì¹©­ì¼t°t¥ó


¡@

¡@

¡@

ùþ²¤¶


ùþ²¤¶

°w¹ï¥ø·~¯Å»Pªñ½u( nearline )À³¥Î¡A¥H³Ì¤jªºÂX¥R©Ê¤Î©µ®i©Ê¡A½á¤©°ª«×ªº¥i¥Î©Ê©M®Ä¯à

VTrak E310f²£«~µJÂI 

RAID±±¨î¾¹¤ä´©¬G»Ù´_­ì( failover) ¡þ¬G»Ù¦^´_( failback )¡A´£¨Ñ°ª«×¥i¥Î©Ê¡C

°í¹êªº2U ¾÷½c¤¤«Ø¦³12­Ó¤ä´©¼ö´¡©ÞªºµwºÐ¼Ñ¡C

´£¨Ñ¥i¦P®É¨Ï¥ÎSAS»PSATA 3Gb/s µwºÐªº¼u©Ê¡C

¨C­Ó±±¨î¾¹´£¨ÑÂù4Gb FC¥D¾÷¤¶­±°ð¡A¨ã³Æ®Ä¯à¤Î³sµ²¯à¤O¡C

RAID 0/ 1/ 1E / 10/ 5/ 6 / 50 /60ªº¸ê®Æ«OÅ@±¹©ì¡A¤ä´©¦h­Ó¥þ°ì©Î±M¥Îªº¼ö³Æ´©µwºÐ (multiple global or dedicated hot-spare drives support)¡C

JBODÂX¥R ¡Ð ³Ì°ª¥i³s±µ¥|­ÓVTrak J-Class JBOD ¨t²Î¡CJBOD expansion - up to 4 VTrak J-Class JBOD systems

³Æ´©ªº¼ö´¡©Þ¹q·½¤Î§N«o¼Ò²Õ¡C

´O¤J¦¡ºô­¶ºÞ²zGUI¡A¥i³z¹LRJ-11§Ç¦C°ð¨Ï¥Î¤A¤Óºô¸ô¤Î©R¥O¦C¤¶­±¡þ¤u¨ã¡C

LUN¹ï¬M (mapping) ¤Î¾B¸n (masking)¡A¥i³]©wSAN¤Î¤j«¬ÂO¶°¡C

PerfectRAIDR»PPredictive Data MigrationR§Þ³N¡A´£¨Ñ°í¹êªº¿ù»~³B²z¤Î´_­ì¥\¯à¡C

µ´¨Îªº¤ä´©¤è®×¡A¥]¬A24 X 7ªº¤ä´©¡]¶È´£¨Ñ­^»yªA°È¡^¤Î¹w¥ý§ó´«­pµe¡C 

¬°¦Ò¶q¤¤¤p¥ø·~¯à­t¾áªº»ù®æ¡A«o¥i¨Ï¥Î¤j«¬¥ø·~µ¥¯Åªº¥\¯à¡A³ì¹©VTrak E-Class±q±ÄÁÊ¡B¦w¸Ë¾Þ§@³]©w©M¤É¯Å¤è­±¡A³£¹ý©³§ïÅÜÀx¦s¸gÀٮįq¡F¨Ï¥ÎSerial Attached SCSI¡]SAS¡^»PSerial ATA¡]SATA¡^µwºÐªº¼u©Ê¡A¥[¤WVTrak E-Classªº¶}©ñ¬[ºc¡A¨Ï¥ø·~¯à¹B¥Î³Ì¾A¦X¨äÀ³¥Î»Ý¨Dªº¤¸¥ó¡C©Ò¦³E-Class¨t¦C²£«~¨Ï¥Î¬Û¦Pªº¶´Åé¡A©ö©ó¶i¦æ³W®æ¼f®Ö§@·~¡C³ì¹©ªºWebPAMR PROe´£¨Ñ¤@®M¿W¥ß©ó§@·~¨t²Îªº¶°¤¤¦¡GUI¡A´£¨Ñ¥þ­±©Êªº¸ê®ÆºÞ²z¯à¤O¡C³ì¹©§ó¥H24 X 7ªº§Þ³N¤ä´©¡B¤T¦~¦³­­«O©T¤Î¹w¥ý§ó´«­pµe¡A¤ä´©©Ò¦³ªºVTrak²£«~¡C 

´¼¼z«¬³]­p´£¨Ñ©µ®i©Ê¤Î¤É¯Å©Ê
¨C­Ó±±¨î¾¹¤W¦³Âù4Gb¥úÅÖ³q¹D¡]FC¡^¥D¾÷¤¶­±°ð¡A¥i³s±µ¦Ü¼sªx³¡¸pªº¥úÅÖ³q¹DÀx¦sºô¸ô¡A¾A¦X©ó¸É¥R²{¦³Àx¦sºô¸ô¤Î«Ø¥ß·sªºÀ³¥Îµ{¦¡Àx¦s¨t²Î¡C¿ï¾Ü²Å¦X¥Ø«e»Ý¨DªºE-Class¨t²Î¡A§Y¾Ö¦³¥u­nÅܧ󱱨´N¯à§ó´«¥D¾÷¤¶­±ªº¼u©Ê¡A¨Ã¥B¥i±NVTrak J-Class¥[¤JJBOD¨t²Î¡A¼W¥[¥i¥ÎªºÀx¦s³]³Æ¡A¥Hº¡¨¬¥¼¨Óªº»Ý¨D¡C¦¹¥~¡A¦bVTrak E-Class»PJ-Class¤¤¹ê¬ISAS§Þ³Nªº¥D­nÀu¶Õ¤§¤@¡A§Y¬O¯à¥H¬Û¦Pªº¤¶­±³s±µSAS©ÎSATAµwºÐ¡C³o¨Ï¥ø·~¯à¦b­«­n°Ó·~¥æ©ö¼W¥[®É¡A«K©óÂX¥RSASÀx¦s³]³Æ¡A¨Ã±N¸û¤Ö¦s¨úªº¸ê®Æ²¾Âà¨ìSATAÀx¦s³]³Æ¤W¡A²¤Æ¸ê®ÆºÞ²zªº§@·~¡C¥t¥~¡A²£«~¤§¶¡¨Ï¥Î¬Û¦PªºFRUs¡A¥ç¯à´î¤Ö³Æ¥Î¹s¥óªºSKUs©M²¤Æ²{³õªº§ó´«§@·~¡C 

µL³æÂI¥¢®Ä
³ì¹©ªºVTrak E310f¤j´TÁY¤p²³æ®e¿ù (simple fault tolerance)¡A»PµL³æÂI¥¢®Ä (No Single Point of Failure) ¤§¶¡ªº®t¶Z¡CE310f¾ã¦X¤@¶µ´¼¼z«¬¡B¥ø·~¯ÅªºµLÆl½u¨t²Î³]­p (cable-less system design)¡A¨ä¤¤¥]¬A§¹¾ã³Æ´©¡B¼ö´¡©Þ±±¨î¾¹¡B¹q·½¤Î§N«o¸Ë¸m¡A³o¨Ç¬Ò¥i¶i¦æ²{³õ§ó´«¡A¨Ã¥B«ùÄòºÊ±±©Ò¦³¨t²Î¤¸¥ó¡A½T«O«ùÄò¹B§@¡A¥HÁקKµo¥ÍºÏºÐ¡B±±¨î¾¹¡B¹q·½¨ÑÀ³¾¹©Î¬O§N«o¸Ë¸m¬G»Ùªº±¡ªp¡CÂù­«active-active¡B¬G»Ù´_­ì¡þ¬G»Ù¦^´_RAID ±±¨î¾¹¡A´£¨Ñ³Æ´©¸ê®Æ¸ô®| (redundant data paths)¡A¶i¤@¨B½T«O¤F¥i¥Î©Ê¡C

§¹¾ãªº¸ê®ÆºÞ²z¥\¯à
VTrak E310f·f°t¤@®M´O¤J¦¡ºÞ²z³nÅéWebPAM PROe¡A±Æ°£¦bºô¸ô¤W¦w¸ËÃB¥~³nÅ骺»Ý¨D¡C¥i³z¹L³æ¤@¡B©ö©óºÞ²zªººô­¶¹Ï§Î¨Ï¥ÎªÌ¤¶­±¡A³]©w©MºÊ±±ºô¸ô¸Ì©Ò¦³VTrak¨t²Î¡A¦Ó³nÅé³z¹LVTrak¨t²Îªº¤A¤Óºô¸ô°ð¡]¦b¥»¾÷ºÝ¡B¸g¹LLAN©Î¬Oºô»Úºô¸ô³s½u¡^¶i¦æ¹B§@¡A¥H³]©w©MºÊ±±¤@­Ó©Î¦h­ÓVTrak¨t²Î¡A¨Ã¥BÂǥѼu¥X°T®§¡B¨Æ¥ó¤é»x©Î¬O¹q¤l¶l¥ó³qª¾´£¨Ñ¿ù»~¦^³ø¡Cµo¥Í±±¨î¾¹¬G»Ù®É¡A³ì¹©ªººÞ²z³nÅé¥ç·|¶i¦æ§¹µ½ªº¬G»Ù´_­ì©M¬G»Ù¦^´_§@·~¡CVTrak¨t¦C²£«~¤]¥i¹B¥Î¤u·~¼Ð·ÇªºSNMP©MCIM¨ó©w¡A²¤Æ»P²Ä¤TªÌºÞ²zÀ³¥Îµ{¦¡ªº¾ã¦X§@·~¡C


¡@


Promise³ì¹©
Promise³ì¹©FC SAN (4Gb¥úÅÖ³q¹DRAID)(VTE310fS) - ServerBank¸ê°T±ÄÁʺô
VTE310fS
Àx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦CRAID>Fibre-to-SATA


¡@
²£«~³W®æ
E-Class 3U/FC ³W ®æ

VTrak E310f³W ®æ

¨t²Î»PºÏºÐ°}¦C¥d¯S¦â
ºÏºÐ°}¦C¥d

Âù­«ºÏºÐ°}¦C¥d²ÕºA(E310f¡ÐÂù­«)/³æ¤@ºÏºÐ°}¦C¥d²ÕºA¡A¥i¤É¯Å(E310f¡Ð³æ¤@)

¦Û°Ê¬G»Ù´_­ì/¦Û°Ê«ì´_RAIDºÏºÐ°}¦C¥d¡FActive/Active with LUN Affinity* or Active/Standby

¤ä´©µwºÐ

³Ì¦h12²Õ3.5¦T x 1¦TªºµwºÐ¡GSAS 3Gb/s¡BSATA II 3Gb/s»P1.5Gb/s -- ³æ¤@I/OºÏºÐ°}¦C¥d²ÕºAªºª½±µ³sµ²©Î¬O¨Ï¥Î³ì¹©SATA MUXÂà´«¥dªºÂù­«I/OºÏºÐ°}¦C¥d²ÕºA¡F¥æ¿ù¦¡¹êÅéµwºÐ±Ò°Ê¤ä´©¦b¦P¤@¨t²Î¤¤¥ô¦ó¦P®É²V·fªºSAS 3Gb/s¡BSATA II 3Gb/s»P1.5Gb/sµwºÐ¡F¥ç¤ä´©ª½±µSATA LED

¥~±µI/O°ð(¨C¤@ºÏºÐ°}¦C¥d)

Âù­«4 Gb¥úÅÖ³q¹D¥D¾÷°ð - ¦^·¹¬Û®e©ó2 Gb»P1 Gb FC HBA¡F³æ¤@¥~±µ3Gb/s SAS x4°ðªºJBODÂX¥R(³Ì¦h4²ÕVTrakJ-Class JBOD¨t²Î)

¸ê®Æ§Ö¨ú

Ãè¹³»P¦@¥Îªº512 MB¹w´ú¦¡¸ê®Æ§Ö¨ú(³Ì¦h¥i¹F2 GB - ½Ð¦V³ì¹©­qÁÊ)¡F¦Û°Ê¼g¤J§Ö¨ú­°¶¥(de-staging)¡F512 MB¦³72¤p®Éªº¹q¦À³Æ´©

«ü¥O¦î¦C²`«× ¨C­ÓVTrakºÏºÐ°}¦C¥d512­Ó«ü¥O
¾Þ§@¥\¯à
RAID¼h¯Å RAID 0¡B1¡B1E¡B5¡B6¡B10¡B50¡B60 - ¥ô¦ó¤W­zRAID¼h¯Åªº²Õ¦X§¡¥i¦P®É¨Ã¦s
RAID¼u©Ê

¥i³]©wRAIDªº±ø±a(stripe)¤j¤p¡G¨CÁûµwºÐ64 K¡B128 K¡B256 K¡B512 K¤Î1 MBªº±ø±a(stripe)¤j¤p

­I´º§@·~Àu¥ý«×½Õ¸`¡G¦b©Ò¦³­I´º§@·~®É½Õ¸`³Ì¤pI/O«O¯dµ¹¦øªA¾¹¨Ï¥Î

§Y®É³Æ¥ó ¥i«ü©w¦h­Ó©Î±MÄݪº§Y®É³Æ¥óµwºÐ¤ÎÁÙ­ì¿ï¶µ
¨C­Ó¤l¨t²Îªº³Ì¤jLUN¼Æ¥Ø ¥ô¦óRAID¼h¯Å¤ÎÃþ«¬²Õ¦X¤U§¡¬°256
¨C­Ó°}¦Cªº³Ì¤jÅÞ¿èµwºÐ¼Æ¥Ø

32­ÓÅÞ¿èµwºÐ(LUN)¡F¥i±N³æ¤@°}¦C¤À³Î¦¨¼Æ­ÓÅÞ¿èµwºÐ¥H¤ä´©LUN¹º¤À¡A¨C­ÓLUNªºRAID¼h¯Å¡B±ø±a¤j¤p¡BºÏ°Ï¤j¤p¡B¥H¤Î§Ö¨ú¤è¦¡³£¥i¦Û­q¡C¤ä´©µL§Ç¦¡ÅÞ¿èµwºÐ§R°£»P­«»s

¨C­Ó¥Ø¼ÐIDªº³Ì¤jLUN¼Æ¥Ø ³Ì¦h256
LUN¾B¸n»P¹ïÀ³ ¤ä´©³Ì¦h128­Ó¥HFC WWPN¬°°ò¦ªº ±Ò°Ê¾¹
µwºÐ¸ê®Æ®æ¦¡ ¤ä´©·~¬É¼Ð·ÇªºµwºÐ¸ê®Æ®æ¦¡(DDF)»PVTrak¨t²Î¶¡ªºµwºÐº©¹C
­I´º°Ê§@

´CÅ騵µø¡F­I´º¦P¨B¡F«e´º±Ò°Ê¡F­««Ø¡F³Æ´©Àˬd¡FSMARTª¬ºA¦@¥Î¡F

OCE (½u¤W®e¶qÂX¥R)¡FRLM (RAID¼h¯ÅÂಾ)¡F

Àu¥ý«×±±¨î¡B³t²v±±¨î¥H¤ÎµwºÐ©MNVRAM¨C­ÓBGAªº¯B¤ô¦L

PerfectRAID

¸ê®Æ¥¿½T©Ê¥\¯à

¹êÅéµwºÐ¿ù»~ÁÙ­ì¡GPDM (¹w´ú¦¡¸ê®ÆÂಾ)¡G§ó´«°}¦C¤¤¦³°ÝÃDªºµwºÐ¡A¨Ã¦b¨ä¥L¥¿±`µwºÐ±N¸ê®Æ­««Ø¦Ü·sµwºÐ®É«O«ù°}¦Cª¬ºA¥¿±`¡AÃa­y¹ïÀ³¡B´CÅ騵µø¡BSMART¡Bµw¦¡/³n¦¡­«³]¥H«K­×´_HD¬G»Ùª¬ºA¡BHD¹q·½±±¨î¥H«K­×´_HD°±º¢ª¬ºA¡C°}¦C¿ù»~­×´_¡G³z¹L³Æ´©RAID¡BRAID 5/6¤£¤@­P¸ê®Æ¨¾½d(Write Hole Table)¡B¸ê®Æ¤º®e¿ù»~¨¾½d(Ū/¼gÀˬdªí) NVRAM¨Æ¥ó¬ö¿ý¡A±qÃa­y©Î¬O¬G»ÙHDÁÙ­ì¸ê®Æ

SCSI«ü¥O

¤ä´©»PSCSI/FCµwºÐ¾÷µ¥®Ä¤§ÂX¥R¦¡SCSI«ü¥O¶°¡F¥H¥iÅܦ¡ºÏ°Ï¤j¤p(±q512 Byte¨ì4 kB)¥´¯}¶Ç²Î­­¨î¡F16 Byte CDB¤ä´©64¦ì¤¸ªºLBA©w§}

¨t²ÎºÞ²z

¤ä´©ªº§@·~¨t²Î

Windows 2000, Windows 2003, Vista/Windows 2008, Linux (Red Hat, SuSE)

¦h­«¸ô®|I/O¤ä´© PerfectPath? Manager¡Ð¨Ï¥Î·L³nªºMPIO¬[ºc(¥u­­Windows)
ºÞ²z¤u¨ã

»P§@·~¨t²ÎµLÃö¡F¨ã³Æ¦hºØ¥»¤g¤Æ»y¨¥¡F¤ä´©SSL¦w¥þ©Ê¡FWebPAM PROe¡F¨Ï¥Î¤A¤Óºô¸ô°ðªººô­¶¦¡GUI¡F«ü¥O¦C¤¶­±»P¨Ï¥ÎRJ-11¦ê¦C°ð©Î¤A¤Óºô¸ô(Telnet)ªº¤u¨ã¡F¦Û°Ê¡B§Ö³t»P¶i¶¥²ÕºA¤ä´©¡A¤À§O¾A¥Î©ó¤Jªù©Î¦³¸gÅ窺¥Î¤á¡C¦bºÞ²z¤A¤Óºô¸ô¨B¶i¦æµLÁ_¦¡³nÅé¬G»Ù´_­ì»P¦Û°Ê«ì´_

ºÞ²z¤¶­±/¨ó©w ´O¤J¦¡ºô­¶¦øªA¾¹»PºÞ²z¤ä´© - ¤ð¶·¨Ï¥Î¥D¾÷¥N²zµ{¦¡¡F¤A¤Óºô¸ô¡BRJ-11¦ê¦C°ð¡FCIM/WBEM¡BSNMP¡BSSL¡BSLP¡BTelnet
¨Æ¥ó´£¥Ü ¹q¤l¶l¥ó¡BNETSEND¡F­µ®Ä(¸Á»ï)¡B¥H¤Î¥iµø(LED)ĵ°T
¾÷±ñ³W®æ

¹qÀ£

¥æ¬y100¦Ü240¥ñ¯S¦Û°Ê½Õ¸`

¹q¬y(¤W­­)

8¦w°ö@100¥ñ¯S¥æ¬y¡F4¦w°ö@200¥ñ¯S¥æ¬y(¹q¬yÃB©w¨Ï¥Î¨â±ø¹q·½½u)

ÀW²v 50¦Ü60 Hz

¹q·½

Âù­«400¥Ë¡BÂù­«¼ö©â´«ªº³Æ´©PFC¡BN+1³]­p

¸`¬ù¥\²v

141.68¥Ë(µLHDD­t¸ü®É)¡B452.68¥Ë(¦³SAS HDD­t¸ü®É)

¾Þ§@·Å«×/·Ã«×

Äá¤ó5«×~40«×(¤£¾Þ§@®É¬°Äá¤ó¹s¤U40«×~Äá¤ó60«×)

¬Û¹ï·Ã«× ³Ì°ª95%

¾_°Ê

ÀH¾÷¡A0.21 grms¡A5¦Ü500 Hz¡AX¡BY¡BZ¶b

¤Ø¤o(°ªx¼ex²`)

8.8 x 44.4 x 56.1¤½¤À(3.5 x 17.5 x 22.1¦T)

­«¶q

*°²³]¨CÁûµwºÐ­«¶q= 0.5¤½¤ç

²b­«(¥u­­¨t²Î)¡GµLµwºÐ®É26¤½¤ç(57½S)¡A¦w¸Ë12ÁûµwºÐ®É 32¤½¤ç(71½S)**

¤ò­«(§t¯È½c)¡G¤£§tµwºÐ®É29¤½¤ç(64½S)

¦w¥þ©Ê CE¡BFCC Class A¡BVCCI¡BC-Tick¡BcUL¡BTUV¡BCB¡BBSMI

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºPromise³ì¹© - VTE310fS - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºPromise³ì¹© - Promise³ì¹©FC SAN (4Gb¥úÅÖ³q¹DRAID)(VTE310fS)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@