­º­¶> Àx¦s³]³Æ/³Æ¥÷¤è®×

>>ÂsÄý©Ò¦³QNAP«ÂÁp³qÀx¦s³]³Æ/³Æ¥÷¤è®×

QNAP«ÂÁp³q
QNAP«ÂÁp³q¤½¥q¦æ¸¹¤Î¥ø·~¥Î¤á(SS-839 Pro)

«¬¸¹¡GSS-839 Pro


QNAP«ÂÁp³qSS-839 Pro


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQNAP«ÂÁp³q - SS-839 Pro - Àx¦s³]³Æ/³Æ¥÷¤è®×
³Ì¦nªºQNAP«ÂÁp³q - QNAP«ÂÁp³q¤½¥q¦æ¸¹¤Î¥ø·~¥Î¤á(SS-839 Pro)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óQNAP«ÂÁp³q¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§QNAP«ÂÁp³q²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§QNAP«ÂÁp³q­ì¼t°t¥ó


¡@

¡@

¡@

ùþ²¤¶


ùþ²¤¶

«ÂÁp³q SS-839 Pro Turbo NAS¬O·s¤@¥N¨Ï¥Î 2.5 ¦T SATA µwºÐªº¥ø·~¯Å 8-bay¦h¥\¯àNAS¦øªA¾¹¡C¨ã³ÆÀu²§ªº®Ä¯àªí²{¡BÂ×´Iªº¦øªA¾¹¥\¯à¡B·~¬É³»¯Åªº RAID¸ê®Æ«OÅ@¾÷¨î¡B¤º«ØiSCSI (internet Small Computer System Interface)¸Ë¸mªA°È¡BAES 256-bitºÏºÐ¸s²Õ¥[±K«OÅ@¾÷¨î(volume-based encryption)¥H¤Îí©wªºµwºÐ¼ö©â´«³]­pµ¥¥ø·~¤ÎªºÀ³¥Î¡C

 

¸`¯à¤Î¦wÀRªº³]­p
SS-839 Pro ¬O¥Ø«e¥«­±¤W³Ì¤pªº 8-bay NAS¡A¦]¦¹¥i»´©ö¦a°t¸m¦b¿ì¤½«Çªº¥ô¦ó¨¤¸¨¡C¥¦¦³µÛ¬Û·í¦nªº´²¼ö¤Î§C¾¸­µ³]­p¡A¬°¤@¸`¯àªºÀx¦s¸Ë¸m¡C°t³Æ 8 Áû 500 GB µwºÐ¡A³]¬° RAID 5 ªº SS-839 Pro ¯Ó¹q¶q¥u»Ý 34 W¡A¥iÀ°±z¸`¬Ù³\¦hªº¹q¶O¤ä¥X¡C

Àu²§ªº®Ä¯àªí²{»P¥iÂX¥R¡B¥i¤É¯Åªº¶i¶¥ RAID ºÞ²z¥\¯à
SS-839 Pro ·f¸üIntel Atom 1.6GHz CPU¡B2GB DDRII °O¾ÐÅé¡A¨Ã¤ä´©RAID 0/ 1/ 5/ 6/ 5 + hot spare¡ASingle¤ÎJBOD¡C¤ä´©½u¤WRAID®e¶qÂX¥R¤ÎRAID²ÕºA¾E²¾ªº¥\¯à¡C

AES 256-bit ºÏºÐ¸s²Õ¥[±K§Þ³N
°w¹ï·¥¾÷±K¸ê®Æªº°ª«×«O±Kªº»Ý¨D¡ASS-839 Pro¤ä´©AES 256-bit¥[±KºÏºÐ¸s²Õ¥\¯à¡A¨Ï¥ÎªÌ¥²¶·¿é¤J±KÆ_±K½X¤~¯à¶}±ÒºÏ°Ï¥H¦s¨ú¦øªA¾¹ªº¸ê®Æ¡A§Y¨ÏµwºÐ¤£·V¿ò¥¢¡A¥ç¥i¤£¥Î¾á¤ß¾÷±K¸ê®Æ³QÅѨú¡C

°ª¼u©Êªº iSCSI ¸Ñ¨M¤è®×
SS-839 Pro°£¤F¯à·í¤@¥x¦h¥\¯àNAS¦øªA¾¹¥H¥~¡A¤]¬O¤@¥xiSCSI target server, ¦¹¤º«Øªº±j¤j¥\¯à¡A´£¨Ñ¤@­Ó­t¾áªº°_ªºIP-SAN(Àx¦s°Ï°ìºô¸ô)¿ï¾Ü¡A¨Ã¥BµêÀÀªÅ¶¡¤À°t(Thin Provisioning)¯S¦â¡A§óÅý±z¥i¼u©Ê¤À°tiSCSI LUNªºªÅ¶¡¡A±z´N¥i¥H¬Ù¥hºÞ²z¹êÅ骺Àx¦sªÅ¶¡ªº³Â·Ð¡C

¦h¥\¯àªº¦øªA¾¹
SS-839 Pro¤ä´©¸óLinux, Unix, Mac©MWindowsªºÀɮפÀ¨É¡A¨Ã´£¨Ñ§ó¦hªº±M·~À³¥Î¡A¨Ò¦p: PHP MySQL/ SQLiteªººô¯¸¦øªA¾¹¡B¦Lªí¾÷¦øªA¾¹ (³Ì¦h¥i¦P®É¤ä´©¤T¥x)¡BÀɮצøªA¾¹µ¥¥ø·~©Ò»Ýªº¥\¯à¡CSS-839 ProµLºÃ¬O¤@­Ó¿ì¤½«Çºô¸ôªº§¹¬üÀx¦s¸Ñ¨M¤è®×¡C

»´ÃP³]©w¡A§CºûÅ@¦¨¥»
SS-839 Pro«e¤èªº LCDÅã¥Ü¿Ã¹õÅý¨Ï¥ÎªÌµL»Ý¨Ï¥Î¹q¸£¡A´N¥i¥H§Ö³t¡B²«K¦a°µRAID²ÕºAªº³]©w¡C¨Ï¥ÎªÌ¥ç¥iÂÇ¥ÑLCDÅã¥Ü¿Ã¹õ¨Ó¬d¾\¨t²Îªº°ò¥»³]©w¡C¹q·½¶}Ãö¾÷±Æµ{ºÞ²z ÅýITºÞ²z¤H­û¥i¥H¼u©Ê¦a¨Ì·Ó¤W¯Z®É¶¡¨ÓºÞ²zNAS¦øªA¾¹ªº¶}Ãö¾÷®É¶¡¡C´¼¼z«¬ªººô¸ô³ê¿ô (Wake on LAN)¥\¯à¤]¥i¥HÅý¦øªA¾¹ºÞ²zªÌ¦b°Ï°ìºô¸ô¤º¤è«K¦a»·ºÝ³ê¿ôNAS¡C

 

§C«Ø¸m¦¨¥»¤Î°ª¼u©Êªº iSCSI ¸Ñ¨M¤è®×
SS-839 Pro¯à°÷¦P®É¤ä´©NAS¤ÎiSCSI¸Ë¸m¡A´£¨Ñ¤¤¤p¥ø·~¤@­Ó­Ý¨ã§C¦¨¥»°ª¼u©Ê¤Î¦³®Ä²vªºIP-SAN¸Ñ¨M¤è®×¡CiSCSI¸Ë¸m¤ä´©°ª¹F8²Õ¡A¯à°÷§@¬° PC©Î¦øªA¾¹¤§Àx¦sªÅ¶¡ªºÂX¥R¡A¤]¥i¥H·í§@¦øªA¾¹(¦p¡G¸ê®Æ®w¦øªA¾¹¡B¹q¤l¶l¥ó¦øªA¾¹)¤§³Æ¥÷¦ì¸m¡C°w¹ïiSCSI¸Ë¸m³]©w¡ASS-839 Pro§ó´£¨Ñ¡uÀx¦s¸ê·½ÀH»Ý¤À°t¡v(Thin Provisioning)ªº¥\¯à¡C¦øªA¾¹ºÞ²z­û¯à°÷§ó¦³®Ä²vªº¦b«Ø¸miSCSI¸Ë¸mªºªì´Á¤£¨ü¹êÅé¥iÀx¦sªÅ¶¡ªº¼vÅT¡A¹w¥ý°µµêÀÀªº°t¸m¡C

AES 256-bitºÏºÐ¸s²Õ¥[±K§Þ³N
°w¹ï·¥¾÷±K¸ê®Æªº°ª«×«O±Kªº»Ý¨D¡ASS-839 Pro¤ä´©AES 256-bit¥[±KºÏºÐ¸s²Õ¥\¯à¡A¨Ï¥ÎªÌ¥²¶·¿é¤J±KÆ_±K½X¤~¯à¶}±ÒºÏ°Ï¥H¦s¨ú¦øªA¾¹ªº¸ê®Æ¡A§Y¨ÏµwºÐ¤£·V¿ò¥¢¡A¥ç¥i¤£¥Î¾á¤ß¾÷±K¸ê®Æ³QÅѨú¡C

Âù Gigabit ºô¸ôºÝ¤f¤ä´©¦h¶µ³]©w

ºô¸ô®e¿ù (Failover)
ºô¸ô®e¿ù´£¨Ñ¤F¤£¶¡Â_ªººô¸ôªA°È¡A·í¨â­Óºô¸ôºÝ¤f³£³s¤Wºô¸ô®É¡A¤@±øºô¸ô½uµo¥Í¬G»Ù°ÝÃD®É¡A¥t¤@±ø¥i¥HÄ~Äò´£¨Ñºô¸ôªA°È¡C

 

ºô¸ô­t¸ü¥­¿Å (Load-Balancing)
SS-839 Pro¤ä´©Bandwidth aggregation¡A¼W¥[Àɮתº¶Ç¿é³t²v(»Ý­n·f°t¤ä´©802.3ad³]©wªº¤A¤Ó¥æ´«¾¹)¡C

 

Âùºô¸ô IP ³]©w
SS-839 Pro ¥i¥H³]©w¨â­Ó¤£¦Pªº IP¡A¨Ã¦P®ÉªA°È¦b¨â­Ó¤£¦P¤lºô¬qªº¤u§@¸s²Õ¡C

±M·~¯Åªº°ª®Ä¯à¡B°ªÃ­©w©Ê¤Î¨ã¨aÃø¨¾½d¾÷¨îªººô¸ôÀx¦s¦øªA¾¹

¤º«Ø¦¡·L«¬µwºÐ°O¾Ð¥d(DOM)·f¸ü´O¤J¦¡¨¾Å@ªºÂù§@·~¨t²Î
¤£¦P©ó¤@¯ëNAS±N§@·~¨t²Î¦w¸Ë©ó¹êÅéµwºÐ¡ASS-839 Pro©Ò¦³ªº§@·~¨t²Î¥H¤ÎÀ³¥Î³nÅé¬Ò¤w¨Æ¥ý´O¤J¤FDOM¡C¦]¦¹±Ò°ÊSS-839 Pro®É¡A§¹¥þ¤£»Ý­nŪ¨ú¹êÅ骺µwºÐ¡A¦Ó¬OŪ¨ú¤º«ØªºDOM¡AÁקK¦]¬°µwºÐÃa­y©Î¬OÀɮ׿ù»~¦Ó³y¦¨ªºµLªk¶}¾÷²{¶H¡C´O¤J¦b·L«¬µwºÐ°O¾Ð¥dªºÂù§@·~¨t²Î¡A¤] ·|½ü¬y°õ¦æ¶}¾÷µ{§Ç¡A·í¨ä¤¤¤@®M§@·~¨t²Î¥¢®Ä®É¡A¥t¤@®M§@·~¨t²Î·|¦Û°Ê»¼¸É¤W¥B§¹¦¨¶}¾÷°Ê§@¡A¨Ã¥B°õ¦æ­×´_¥t¤@®M§@·~¨t²Îªº°Ê§@¡CÂù­««OÅ@¤§¤U¡AÅý¨t²Î³B ¦b·¥¨ÎªºÃ­©wª¬ºA¡C

¥ý¶iªºRAIDºÏºÐ°}¦CºÞ²z¤Î¤ä´©¼ö©â´«³]­p
¬°¤F½T«O¸ê®Æªº¦w¥þ©Ê¡ASS-839 Pro´£¨Ñ¥ý¶iªºRAIDºÏºÐ°}¦CºÞ²z¥\¯à¡A¥u­n³z¹L²³æ­¶­±³]©w§Y¥i»´ÃP§¹¦¨³]©w¡A¨ä¤¤¥]¬ARAID 0¡B1¡B5¡B6¡B5 + hot spare¡Bsingle¤ÎJBOD¡CSS-839 Pro¤ä´©¼ö©â´«ªº³]­p¡A´£¨Ñ±z¤£¶¡Â_»P®e©öºûÅ@ªºªA°È¡C»â¥ý·~¬Éªº RAID ºÞ²z³]­p¡A¬Û¤ñ©ó¨ä¥¦«~µPªºNAS¡A¥i¥H®e³\§ó¦h¤@ÁûªºµwºÐ·l·´¡A³o¼Ëªº³]­p¥i¥H±aµ¹¨Ï¥ÎªÌ¤@­Ó§ó¦w¥þªº¸ê®ÆÀx¦sÀô¹Ò¡C

½u¤WRAID®e¶qÂX¥R
RAID®e¶qÂX¥RÅý¨Ï¥ÎªÌ¥i¦b«O¯d©Ò¦³¸ê®Æ¡B¤£°±¾÷ªº±¡ªp¤U¡A¤@¨B¤@¨B¦a¶¶§Qªº¶i¦æRAID®e¶qÂX¥R¡C

 

 

 

½u¤WRAID²ÕºA¾E²¾
½u¤WRAID²ÕºA¾E²¾Åý¨Ï¥ÎªÌ¥i³z¹L²©ö¨BÆJ¡A¦b¤£°±¾÷¥B«O¯d¸ê®Æªºª¬ºA¤U¶i¦æRAIDµ¥¯Å¾E²¾¡C

 

 

³z¹LµêÀÀºÏºÐ ¡A¼u©ÊÂX¥R±zªº NAS ®e¶q
¸g¥Ñ¿W¯Sªº¡u¥~±µµêÀÀºÏºÐ¡v¡AºÞ²zªÌ¯à§ó¼u©Ê¦aÂX¥R NAS ªº®e¶q¡C³z¹L¤º«ØªºiSCSI initiator¥\¯à¨Ó³s±µºô¸ô¤W¨ä¥L iSCSI target¡A¥i±N¨äÅܦ¨¨t²Î¤WªºµêÀÀºÏºÐ¡CQNAP NAS ¥i°µ¬°°ïÅ|¥D¸Ë¸m (stack master) ¡A³s±µ¦h¹F 8 ­ÓµêÀÀºÏºÐ/°ïÅ|¥Ø¼Ð (stack targets)¡C¦]¦¹¡A©Ò¦³ªº NAS ¨Ï¥ÎªÌ¶È»Ý³s½u¦Ü¦¹³æ¤@¤J¤f¡A§Y¥i¨Ï¥Î¦ì©ó¨ä¥¦ºô¸ôÀx¦s¸Ë¸m¤WªºªÅ¶¡¡C

 

¤º«ØiSCSI ¸Ë¸mªA°È
¹ï¤¤¤p¥ø·~¦Ó¨¥¡A°w¹ï²{¦b¨Ï¥Î¤¤ªº¦øªA¾¹¯à°÷¾Ö¦³¤@­Ó²z·Qªº°ª®Ä¯à¤ÎÀx¦sªÅ¶¡ÂX¥R¸Ñ¨M¤è®×¬O¥²­nªº¡CµM¦Ó¡A¥Ø«e¥«­±¤W¤j³¡¤À¬ÛÃö²£«~¡A¤£¬O¤£°÷¦³®Ä²vªºÀ³ ¥Î (¦p¡GDAS¡ADirect Attached Storage) ´N¬O©Ò¶O¤£¸í¤Î¹L©ó½ÆÂø (¦p¡GFiber Channel SAN)¡C«ÂÁp³qªºSS-839 Pro ¯à°÷¦P®É¤ä´©NAS¤ÎiSCSI ¸Ë¸m¡A´£¨Ñ«Ø¸mIP-SAN¤@­Ó§C¦¨¥»¤Î¦³®Ä²vªº¸Ñ¨M¤è®×¡C¦øªA¾¹ºÞ²z­û¯à°÷¨Ï¥Î¤º«ØªºiSCSI ¸Ë¸mªA°È«Ø¥ß³Ì¦h¤K²Õ¸Ë¸m¡C¤£¦PªºiSCSIÅÞ¿è³æ¤¸¼Æ(LUNs: Logical Unit Number) ¯à°÷°µ¬°²{¦³Àx¦sªÅ¶¡ªºÂX¥R©Î¬O²{¦sÀ³¥Î¦øªA¾¹ (¦p¡G¸ê®Æ®w¦øªA¾¹¡B¹q¤l¶l¥ó¦øªA¾¹)ªº³Æ¥÷¦ì¸m¡C

¦¹¥~¡A°w¹ïiSCSI ¸Ë¸m³]©w¡ASS-839 Pro §ó´£¨Ñ¡uÀx¦s¸ê·½ÀH»Ý¤À°t¡v(Thin Provisioning) ªº¥\¯à¡C¦øªA¾¹ºÞ²z­û¯à°÷§ó¦³®Ä²vªº¦b«Ø¸miSCSIÅÞ¿è³æ¤¸¼Æ(LUN)ªºªì´Á¤£¨ü¨ì¹êÅé¥iÀx¦sªÅ¶¡ªº¼vÅT¥ý°µµêÀÀªº°t¸m¡F·í¹êÅéµwºÐªºÀx¦sªÅ¶¡§Ö­n¤£ ¨¬®É¡A¥i¥H³z¹L«ÂÁp³qNAS­ì¦³ªº¡u½u¤WRAID®e¶qÂX¥R¡vªº¥\¯à©Î¬O®Ú¾Ú»Ý¨D½Õ¾ã©Î²¾°£¥Ø«e¥¼¨Ï¥ÎªºÀx¦sªÅ¶¡¨Ó¥[¥HÂX¥R®e¶q¡C

S.M.A.R.T.¤Î¶i¶¥µwºÐª¬ºA±½´y(HHS)
Turbo NAS¤ä´©µwºÐS.M.A.R.T. (Self-Monitoring Analysis and Reporting Technology)¡A¯à°÷ºÊµøµwºÐª¬ºA¡BÀˬd¼ç¦b°ÝÃD¡A¨Ã³z¹LEmail³]©wµo¥Xĵ§i°T®§¡A´£¿ô¨Ï¥ÎªÌ¹w¥ý°µ¦n«OÅ@µwºÐ¸ê®Æªº±¹¬I¡C¦¹¥~¡ANASªº HHS (HDD Health Scanning)§Þ³N¡A¯à°÷Àˬd¨Ã±½´yµwºÐªºª¬ªp¡A¥H¹w¨¾¼ç¦b©Êªº¸ê®Æ·l¥¢¡C

²³æªº RAID ²ÕºA³]©w¤è¦¡

Touch-N-Go LCD§Ö³t¦w¸Ë
±z¥i¥H¨Ï¥Î¤è«KªºLCD¿Ã¹õ§@RAID²ÕºAªº§Ö³t¦w¸Ë¡A¥u»Ý­n¤T­Ó¨BÆJ¡A¨t²Î·|¦Û°Ê®æ¦¡¤ÆµwºÐ¥H¤Î«Ø¥ßRAID²ÕºA¡C

 

¤ä´©Windows, Mac, Linux ¤ÎUnix ¸ó¥­¥xªºÀɮפÀ¨É
Turbo NAS±Mªù³]­p¸ó¥­¥xªº¤ä´©¡A´£¨Ñ¤£¦P§@·~Àô¹Òªº¨Ï¥ÎªÌ¯à°÷»´ÃP¦a¤À¨ÉÀɮ׸ê®Æ¡C

¤ä´©Windows ADªA°È»{ÃÒ
³z¹LWindows AD ªA°Èªº»{ÃҤ䴩¡AÅý¦øªA¾¹ºÞ²zªÌ¥i¥H»´ÃP¦a±qADºô°ì¶×¤J¨Ï¥ÎªÌ±b¤á¸ê®Æ¨ìTurbo NAS¡C¤£¦ý¤j¤j¦a¸`¬Ù¤FºÞ²z­û½Æ»s±b¸¹¤Î¸s²Õªº®É¶¡¡A¨Ï¥ÎªÌ¤]¥i¥HÄ~Äò¨Ï¥Î­ì¦³ªº±b¸¹¥H¤Î±K½X¡C

ºô­¶¦¡Àɮ׺޲z¤¶­±
SS-839 Pro´£¨Ñºô­¶¦¡Àɮ׺޲z¤¶­±¡AÅý±z¥i¥H³z¹LÂsÄý¾¹»´ÃP¦a¤W¶Ç¤U¸ü¤ÎºÞ²z¦øªA¾¹¤ºªºÀɮסC

¸ê®Æ§¨ºÞ²z
ºÞ²zªÌ¥i¦b«Ø¥ß¦øªA¾¹¤§¸ê®Æ§¨®É³]©wÅã¥Ü©ÎÁôÂæ@¨É¸ê®Æ§¨¡A¥[±j¸ê®Æ«OÅ@¡C

¹q·½ºÞ²z

µwºÐ«Ý¾÷³]©w
¨Ï¥ÎªÌ¯à°÷³]©wµwºÐ¦b¯S©w®É¶¡µL¶i¦æ¸ê®Æ¦s¨ú®É§Y¶i¤J«Ý¾÷ªº³]©w¡C

¹q·½¶}Ãö¾÷±Æµ{ºÞ²z
¦¹¥\¯àÅý¨Ï¥ÎªÌ¼u©Ê¤Æ¦a³]©wNASªº¶}Ãö¾÷®É¶¡¡A±z¥i¥H¨Ì·Ó¤u§@®É¶¡¡A³]©w¦b¥ô¦ó®É¶¡§@¦Û°Ê¶}¾÷¡BÃö¾÷©Î¬O­«·s±Ò°Êµ¥¡C

UPS¤£Â_¹q¨t²Î¤ä´©
Turbo NAS¤ä´©USB¤£Â_¹q³]³Æ (usb-hid ups)¡AÅý¨Ï¥ÎªÌ¦b¥¼¹w´ÁªºÂ_¹q®É¡A¯à°÷¤Î®É°µ³B²z¡AÁקK­«­n¸ê®Æªº¿ò¥¢¡C

¤ä´©AC¹q·½¦^´_®É¡A¨t²Î¹q·½³B²z¤è¦¡³]©w
Turbo NAS¤ä´©¥«¹qÂ_¹q«á¹q·½«ì´_®É¨t²Îªº³B²z¤è¦¡¡C±z¥i¥H³]©w¦^´_¦Ü«e¤@¦¸ªº¶}¾÷©ÎÃö¾÷ª¬ºA¡C

QNAP ¿W®a³Æ¥÷³nÅé - NetBak Replicator
QNAP´£¨Ñªº¿W®a³Æ¥÷³nÅé ¡V NetBak Replicator¡AÅý¨Ï¥ÎªÌ»´ÃP¦a³Æ¥÷Windows¹q¸£¤ºªº¸ê®Æ¦ÜTurbo NAS¡A³nÅé¤ä´©§Y®É³Æ¥÷¡B¸ê®Æ¦P¨B¤Î±Æµ{³Æ¥÷µ¥¥\¯à¡C

¬Û®e²Ä¤T¤è³Æ¥÷³nÅé
QNAP NAS¬Û®e©ó¥«­±¤W¥D¬yªº³Æ¥÷³nÅé¡A¨Ò¦pAcronis True Image, CA BrightStor ARCserve Backup, EMC Retrospect, Symantec Backup Exec¤Î LaCie Silverkeeperµ¥¡C

Rsync»·ºÝ³Æ¥÷
¦bTurbo NAS¸Ì­±ªº¸ê®Æ¥i¥H»·ºÝ³Æ¥÷¨ìQNAPªºNAS¨t¦C²£«~¸Ì­±¡A©Î¬OÂÇ¥ÑRsync ³Æ¥÷¸ê®Æ¨ì¤ä´©Rsyncªº¦øªA¾¹¡C

USB³æÁä¦Û°Ê³Æ¥÷
Turbo NASªº§Ö³t«þ¨©Áä¥i¥H³]©w¬°±Ò°Ê¥ß§Y½Æ»s¥~±µUSB¸Ë¸mªº¸ê®Æ¨ìNAS¡A©Î¬O½Æ»sNASªº¯S©w¸ê®Æ§¨¨ì¥~±µUSB¸Ë¸m(³æÁä¦Û°Ê³Æ¥÷¥\¯à¥u¦³¨Ï¥ÎNAS«e¤èªºUSB port¤~¥i¥H±Ò°Ê)¡C

 

¦w¥þ¸ê®ÆÀx¦s¡B¦s¨ú¤Î¤À¨É

  • IP¦ì§}¹LÂoºÞ²z¡GºÞ²zªÌ¥i¥H¤¹³\©Î¬O©Úµ´¯S©wªºIP¦ì§}³s±µ¨ìTurbo NAS¡C
  • SSL ¦w¥þ©ÊºÞ²z (HTTPS)¡GºÞ²zªÌ¥i¥H³z¹Lºô­¶¦w¥þ¦a¦s¨ú¤ÎºÞ²z¸ê®Æ¡C
  • ³z¹LSSH (Secure Shell)¡A»·ºÝµn¤JTurbo NAS¡C
  • ¥[±K FTP¡G³z¹LSSL/ TLS (explicit) ¥[±K¨Ó¤À¨É¤Î¶Ç¿é±zªº¸ê®Æ¡C ¨Ã¥B¤ä´©FTP³Q°Ê¼Ò¦¡¤ÎÀW¼eºÞ²z¡C
  • ´¼¼z«¬FTPºÞ²z¡GºÞ²zªÌ¥i©Ò¦³FTP³s½u¤Î­Ó§O±b¸¹ªº³s½u¤W­­¡C
  • ¥[±K²§¦a³Æ´©¡GTurbo NASªº¸ê®Æ¥i¥H³z¹Lºô¸ô¥[±K³Æ¥÷¨ì¨ä¥LªºQNAP NAS¨t¦C²£«~¡C
  • FTP¼g¤J(Write-only)Åv­­³]©w¡G¦øªA¾¹ºÞ²z­û¥i¥H°w¹ï¨Ï¥ÎªÌ°µ¶È¦³³z¹LFTP¤W¶Ç¸ê®Æ¨ìNAS¦ýµLªk½s¿è©Î¬O¤U¸ü¸ê®ÆªºÅv­­³]©w¡C

ºô¸ô¦Û°ÊIP³s½u¹LÂo
¬°¨¾½dNAS¾D¨ü¨ìºô¸ô´c·N¤J«I¡A¦øªA¾¹ºÞ²z­û¯à°÷«Ø¸m¤¹³\¡B©Úµ´©Î¬O¦Û°Ê«ÊÂê³z¹LSSH/ Telnet/ HTTP(S)/ FTP/ samba/ AFPªº¦Û°Ê³s½u¹LÂo¾÷¨î¡A§ó¥[±j¤Æºô¸ôªº¦w¥þ¨¾Å@¡C

¥\¯à±j¤jªº¨t²ÎºÞ²z¤u¨ã

»·ºÝ³ê¿ô (Wake on LAN)
¨Ï¥ÎªÌ¯à°÷¥Î»·ºÝ»»±±ªº¤è¦¡³ê¿ô¦b°Ï°ìºô¸ô¤ºªºNAS¡C

´¼¼z«¬­·®°
­·®°ªºÂà³t¯à°÷®Ú¾Ú¥Ø«eªº¨t²Î·Å«×¦Û°Ê¦a°µ½Õ¾ã¡CºÞ²zªÌ¦P®É¯à°÷³z¹L¤â°Ê©w¸q°ªÂà¤Î§CÂ઺³]©w¡C

§Y®ÉSMS & Emailĵ°T³qª¾
¦øªA¾¹ºÞ²z­û¥i¥H³z¹LSMTP¤ÎSMSC(Short Message Service Center)ªº³]©w¡A¥ß§Y±µ¦¬§Y®ÉEmail¤Î²°T³qª¾¡AÀH®ÉÀH¦a»´ÃP´x´¤NASªº³Ì·sª¬ºA¡C

¤ä´©SSL (Secure Sockets Layer)¦w¥þ¾ÌÃÒ
ºÞ²zªÌ¯à°÷¤W¶Ç¸g»{¥iªº¦w¥þ¾ÌÃÒ¤ÎX.509PEM®æ¦¡ªºRSA¨p¤Hª÷Æ_Åý¨Ï¥ÎªÌ¯à°÷³z¹LSSLµn¤J¨Ó¦s¨úNASªº¸ê®Æ¡C

¤ä´©¨t²Î¤é»x(Syslog)¦øªA¾¹³]©w
³z¹L¦¹³]©w¡A©Ò¦³NASªº¨Æ¥ó°O¿ý¤Î³s½u¬ö¿ý¯à°÷³QÀx¦s¨ì»·ºÝ¨t²Î¤é»x(Syslog)¦øªA¾¹¤¤¡C

ºô¸ô¸ê·½¦^¦¬µ©
¦bNASºô¸ô¸ê®Æ§¨ùاR°£ªºÀÉ®×±N·|³Q²¾¨ì¯S©wªº¸ê·½¦^¦¬¸ê®Æ§¨¡C³z¹L³o¼Ë¥\¯à¡A±z¥i¥HÀH®É¦^¦s±z¤£¤p¤ß§R°£ªºÀɮסC

¹d²ÓÃû¿òªº¨Æ¥óºÞ²z¨t²Î
Turbo NASªº©Ò¦³³s½u°O¿ý¡A¥]¬Asamba¡BFTP¡BAFP¡BHTTP¡BHTTPS¡BTelnet¡BiSCSI¤ÎSSH¡A¥H¤Î³z¹Lºô¸ôªA°Èµn¤J¨t²Îªº½u¤W¨Ï¥ÎªÌ³s½u¸ê°Tµ¥¡AÅýºÞ²zªÌ¯à°÷®e©öºÞ²z¨Ã´x´¤©Ò¦³ªº¸Ô²Óª¬ªp¡C

¸ÔºÉªº¨t²Î¸ê°T
¦øªA¾¹ºÞ²z­û¯à°÷³z¹LºÞ²zªÌ¨Ï¥Î­¶­±´x´¤¸ÔºÉªº¨t²Î¸ê°T¡A¨Ò¦p¡GCPU¨Ï¥Î²v¡B©Ò¦³°O¾ÐÅé¤Î¥i¨Ï¥ÎªºªÅ¶¡¡Bµo°e±µ¦¬¤Î¿ù»~ªº«Ê¥]¼Æ¡B¨t²Î¶}¾÷¡BCPU·Å«×¡B¨t²Î·Å«×¡BµwºÐ·Å«×¤Î¨t²Î­·®°ªºÂà³tµ¥¡C

¦w¥þºÊ±±¤¤¤ß
Turbo NASªº¦w¥þºÊ±±¤¤¤ß(Surveillance Station)ª½±µ±ÂÅv¥i¦P®É·f°t4¤äºô¸ôÄá¼v¾÷(IP Camera)¡AÅý±z¯à°÷³z¹Lºô»Úºô¸ô³]©w¤Î°µ»·ºÝºÞ²z¡A¨ä¤¤¥]§t§Y®ÉºÊ±±¿ý¼v(real-time monitoring recording)¡B³z¹LIEÂsÄý¾¹Æ[¬Ý§Y®É¼v¹³(Live View)¡A¼½©ñ(Playback)¤Î¨Æ¥ó°O¿ý(Log)µ¥¡C¥t¥~¡A¦w¥þºÊ±±¤¤¤ß¥ç¦³¶K¤ß³]­pªº¶i¶¥¿ý¼v¥\¯à³]©w¥]§t³sÄò¿ý¼v(Continuous recording)¡B¦ì²¾°»´ú¿ý¼v (Motion-detection recording)¤Î±Æµ{¿ý¼v(Schedule recording)µ¥¡A±z¥i¥H®Ú¾Ú¤£¦P®É¬qªº»Ý¨D¡A¿ï¾Ü±ý°õ¦æªº¼Ò¦¡¡A¦b¹F¨ì¦w¥þºÊ±±»Ý¨Dªº¦P®É¡A¥ç¯à°÷­ÝÅUTurbo NAS®Ä¯à¡B¸`¬ÙµwºÐÀx¦sªÅ¶¡¤Î¹F¨ìÀô«O¸`¯àµ¥¦h­«®ÄªG¡C³z¹L¦w¥þºÊ±±¤¤¤ß¡A©Ò¦³ªº¿ý¼vÀÉ®×±N¥HAVIÀɮ׮榡Àx¦s¡A¨Ã¤ä´©®É¶¡ÂW(Time Stamp)¡A±z¥i¥H«Ü®e©ö¦a·j´MÀÉ®×¥Bª½±µ¨Ï¥ÎWindows Media Player¼½©ñ¡C

¤ä´©³Ì¼sªxºô¸ôÄá¼v¾÷«~µPªººô¸ô¦w¥þºÊ±±¤è®×
¦w¥þºÊ±±¤¤¤ß¤ä´©¥«­±¤W¦h´Ú«~µPªººô¸ôÄá¼v¾÷¨Ã³q¹L¹êÅç«ÇÄY®æªº¬Û®e©Ê»P«H¿à©Ê´ú¸Õ¡A¥]¬A¤FAXIS¡BD-Link¡BIPUX¡BLevelOne¡B Linksys¡BPanasonic ¤ÎVIVOTEKµ¥¡C·f°t¯S©w«¬¸¹ªºÄá¼v¾÷¡A¨Ï¥ÎªÌ¥ç¯à°÷³z¹Lºô­¶°õ¦æÂù¦V¼v­µºÊ±±¿ý¼v(Two-way video & audio)¡A´¼¼z«¬PTZ¾Þ§@(Pan, Tilt, Zoom)¨Ó±±¨îºÊ±±ªº¤è¦ì¡C

³nÅéÂX¥R¤Îºô¯¸ºÞ²z

ºô­¶¦øªA¾¹
Turbo NAS¤ä´©MySQL¤ÎSQLite¡A¤º«ØphpMyAdmin¤ÎJoomla!¡A±z¥i¥H»´ÃP¦a¬[³]ÄÝ©ó­Ó¤H¤Æªº¤¬°Ê¦¡ºô­¶¡C³z¹L¥i½s¿èªºphp.ini ¤ä´©¡AÅý±z¦b³]©w®É¥i¥H§K¥h¶Ç²Î¦w¸ËWindows-based¦øªA¾¹ªº³Â·Ð¡C±z¤]¥i¥H¦Û¦æ¶}µo©Î¬O¦w¸Ë¤U¸üopen-sourceªºÀ³¥Î¡A¹³¬O¬[³]Áʪ« ºô¯¸¡B½×¾Â¡Bblogµ¥¡C

MySQL¦øªA¾¹
Turbo NAS¬O±z³Ì¸gÀÙ¹ê´fªº¸ê®Æ®w¦øªA¾¹ªº¿ï¾Ü¡C¥¦¥i¥HÀ³¥Î¬°¤@¥x»·ºÝºô­¶¦øªA¾¹ªº¸ê®Æ®w¦øªA¾¹©Î§@¬°ÃB¥~ªº³Æ¥÷¸ê®Æ®w¡C

¤º«Ø¤ä´©°ÊºAºô°ì¦WºÙ¨t²Î (DDNS: Dynamic Domain Name Server)
Turbo NAS¤ä´©DDNS¡A±z¥i¥H³z¹LDDNSªA°Èªº¨ÑÀ³°Ó¡Aµù¥U¯S©wªººô°ì¦WºÙ¡A¨Ã±N¨ä«ü©w¨ìTurbo NAS¡AÅý±z³z¹Lºô°ì¦WºÙ³s½u¦Ü¨t²Î¡A¤£»Ý°O¤U¤¾ªøªºIP¦ì§}¡C

³z¹LQPKG¥­¥xÂX¥RTurbo NAS·sÀ³¥Î
QNAP¿W®aªºQPKG¥­¥xÅý¨Ï¥ÎªÌ¤£¥Î¸g¥ÑÁcÂøªºµ{§Ç¡A«K¯à°÷³z¹L²³æªº¤U¸ü»P¦w¸Ë¡A¨É¨ü¨Ó¦Û¥þ²yªÀ¸s©Ò¶}µoªº¬ÛÃö³nÅé®M¥ó¨ÓÂX¥RTurbo NASªºÀ³¥Î¡C

 


QNAP«ÂÁp³q
QNAP«ÂÁp³q¤½¥q¦æ¸¹¤Î¥ø·~¥Î¤á(SS-839 Pro) - ServerBank¸ê°T±ÄÁʺô
SS-839 Pro
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ
Hardware Spec
Hardware Spec.
CPU Intel Atom Processor 1.6 GHz
DRAM 2GB DDRII RAM
Flash Memory 128MB DOM
HDD 8 x 2.5" SATA I/II HDD, ( the standard system is shipped without HDD)
HDD Tray 8 x hot-swappable and lockable tray
LAN Port 2 x Gigabit RJ-45 Ethernet port
LED Indicators Status, LAN, USB, eSATA, HDD 1-8
USB 5 x USB 2.0 port (front: 1; back: 4)
Supports USB printer, disk, pen drive, USB hub, and USB UPS, etc.
eSATA 2 x eSATA port (back)
Buttons System: Power button, one touch copy button, reset button
LCD panel Mono-LCD display with backlight and buttons for configuration
Alarm Buzzer System warning
Form Factor Tower
Dimensions 177(H) x 180(W) x 235(D) mm
6.97(H) x 7.09(W) x 9.25(D) inch
Weight Net weight: 3.92kg/ 8.64 lb
Gross weight: 5kg/ 11.0 lb
Sound Level (dB) W/o HDD installed: 35 dB
Stand by: 34.7 dB
In operation: 35.8 dB
(Background: 24.9 dB)
Power Consumption (W) Sleep mode: 25W
In operation: 34W
(with 8 x 500GB HDD installed)
Temperature 0~40˚C/ 32~104¢XF
Humidity 0~95% R.H.
Power Supply Input: 100-240V AC, 50/60Hz, Output: 220W
Secure Design K-lock security slot for theft prevention
VGA Reserved
Fan 1 x quiet cooling fan (9 cm, 12V DC)
Software Spec.
Powerful All-in-one server
File Server File sharing across Windows/ Mac/ Linux/ Unix and centralized management
FTP Server Supports data access from remote location via FTP (max. 256 concurrent connections)
FTP with SSL/ TLS (explicit) mode
FXP supported
FTP bandwidth control and connection control
Passive FTP port range control
Backup Server QNAP client-side backup software-NetBak Replicator supports instant, schedule, and auto-sync backup
3rd party backup software support: Acronis True Image, CA Brightstor ARCserve Backup, EMC Retrospect, Symantec Backup Exec, LaCie Silverkeeper
Printer Server Network printer sharing via USB (Windows & Mac)
Supports all-in-one printer (max. 3 sets)
Remote Replication Block-level remote replication supports instant, schedule backup management; supports synchronization mode
Web Server Built-in phpMyAdmin, Joomla!, editable php.ini, SQLite and MySQL
My SQL Server Supports MySQL database server
UPnP Media Server Supports UPnP/ DLNA multimedia technology; the video, music, and photos on the NAS can be played by digital media players over the local network
Internet radio (built-in TwonkyMedia)
Media playing with PS3, Xbox360, PSP game consoles
iTunes Server iTunes server for music sharing
Smart playlist for iTunes software
Multimedia Station Image slide show and rotation (+90¢X, -90¢X)
Display photo details: dates, exposure time, aperture, etc.
Automatic thumbnail generation for easy browsing
Photo album access authority management
Multimedia files (video and audio) local playing
Automatic file categorization
Download Station PC-less BitTorrent/ FTP/ HTTP download
QNAP remote download control software:
QGet (Windows & Mac), allows you to control the download tasks of multiple Turbo NAS on one PC via LAN/ WAN
BitTorrent download supports TCP/ UDP, DHT
BT schedule download
BT download (up to 500 tasks)
Download configuration (current seed number, configurable port range, bandwidth control, download percentage, UPnP NAT port forwarding for BitTorrent download)
Download status list management (download percentage)
Supports access from Mac by Mozilla Firefox
Surveillance Station Supports 4 IP cameras (optional purchase) for network surveillance
Software Specifications
Operating System Linux-embedded system
Networking TCP/IP, DHCP Client, DHCP Server, CIFS/SMB, AFP, NFS, HTTP, HTTPS, FTP, DDNS, NTP
Multi-IP setting
Gigabit Jumbo Frame
Port Trunking
- Balance-rr (Round-Robin)
- Active Backup
- Balance XOR
- Broadcast
- IEEE 802.3ad
- Balance-tlb (Adaptive Transmit Load Balancing)
- Balance-alb (Adaptive Load Balancing)
Network Service Discovery (UPnP & Bonjour)
File System EXT3 (Internal/ external HDD)
EXT4 (Internal/ external HDD)
FAT (External HDD)
NTFS (External HDD)
Supported Operating Systems Microsoft Windows 98/ ME/ NT/ 2000/ XP/ 2003/ Vista
Mac OS X
Linux
Unix
Disk Management Single disk, RAID 0, RAID 1, RAID 5, RAID 5 + hot spare, RAID 6, and JBOD (Linear Disk Volume)
Multiple RAID
Online RAID Capacity Expansion
Online RAID Level Migration
Disk usage status management
Check disk (Check Linux file system)
HDD S.M.A.R.T.
Bad blocks scan
PC-less RAID setup via LCD panel for the first time installation (Touch-N-Go)
AES 256-bit volume-based encryption
Built-in iSCSI target service
RAID Recovery
Virtual Disk
User Management User quota management (per user)
Windows AD
User account management (max. 4,096 users)
User group management (max. 512 groups)
Batch creating users
File System Management Network share management (max. 512 shares)
Network volume status management
Share folder level ACL support
Hide share folder on Windows network
Unicode support
Journaling file system
Web File Manager
System Tools E-mail alert (SMTP authentication)
SMS alert
HDD standby mode
Disk usage alert
Automatic power on after power loss
QPKG add-on firmware supported
System firmware upgrade
Back up, restore, reset system settings
Smart fan setting
Configurable management port
Policy-based unauthorized IP blocking
Secure remote login by SSH connection
Remote login by Telnet connection
USB, SNMP UPS support
Wake on LAN
Schedule power on/ off (max. 15 settings)
Network recycle bin
Import SSL certificate
SNMP
Real-time System Resource Monitor
LCD RAID configuration for the first time setup
When the system is ready, users can check or configure the IP settings, physical disk info, volume info, system info, shut down or reboot the NAS, etc.
Event Logs Complete system logs (file level): system events management, connection logs, current connection of on-line users
Multilingual Support English, Traditional Chinese, Simplified Chinese, Japanese, Korean, French, German, Italian, Spanish, Russian, Swedish, Norwegian, Finnish, Danish, and Polish
Backup Management PC-client backup software-NetBak Replicator: Instant/ Schedule/ Auto-sync backup
Remote replication supports Rsync
Encrypted remote replication
USB one touch copy backup
Data backup to external storage devices
Multi-browser support Internet Explorer 7 & 8
Safari 3 & 4
Firefox 3
Google Chrome

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQNAP«ÂÁp³q - SS-839 Pro - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºQNAP«ÂÁp³q - QNAP«ÂÁp³q¤½¥q¦æ¸¹¤Î¥ø·~¥Î¤á(SS-839 Pro)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 NASºô¸ôÀx¦sÀɮצøªA¾¹
 ServerBank±ÀÂ˾÷ºØ
 ®à¤W«¬
 ¾÷¬[¦¡
 ª½¥ß¦¡
 ºÏºÐ°}¦C°t¥ó
 ¦Û°Ê¥úºÐ«þ¨©¾÷
 ¥~±µ¦¡µwºÐ
 ºÏ±a¾÷
 SDLT
 DLT
 LTO 1/2/3/4
 Ultrium I
 Ultrium II
 SAIT
 AIT
 AIT Turbo
 DAT
 DDS
 ºÏ±a´«±a¾÷Autoloader
 iSCSI¸Ñ¨M¤è®×
 iSCSIºÏºÐ°}¦C
 iSCSI¾ô±µ¾¹
 ºÏºÐ°}¦CRAID
 ServerBank±ÀÂ˾÷ºØ
 iSCSI
 iSCSI to SAS
 SATA
 SCSI-to-SCSI
 SCSI-to-IDE
 SCSI-to-SATA
 Fibre-to-SCSI
 Fibre-to-IDE
 Fibre-to-SATA
 Fibre-to-Fibre
 Fibre to SAS
 USB-to-IDE
 SATA-to-SATA
 SATA-to-IDE
 SAS
 IDE-to-IDE
 1394-to-IDE
 JBOD
 ºÏºÐ°}¦CÂd
 1394B-to-SATAII
 1394B-to PATA
 °ïÅ|¦¡Àx¦s¥~±µ²°
 SAS-to-SATA
 SAS-to-SAS
 SCSI-to-SAS
 PCIE
 USB
 IDE
 SAN¸Ñ¨M¤è®×
 ¥úÅÖ³q¹D¥æ´«¾¹
 ¥úÅÖ³q¹D¤¶­±¥d
 SAN Storage
 SAN Software
 ¥úÅÖ³q¹D¾ô±µ¾¹
 ¾É¦V¾¹director
 ¥úÅÖ¼Ò²Õ
 Àx¦sºÞ²z³nÅé
 ºÏ±aÂd
 ºÏ±a
 ¦Û°Ê´«¤ù¥úºÐ
 ÂÅ¥ú¥úºÐÂd
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > Àx¦s³]³Æ/³Æ¥÷¤è®×


QNAP«ÂÁp³qSS-839 Pro

QNAP«ÂÁp³q¤½¥q¦æ¸¹¤Î¥ø·~¥Î¤á(SS-839 Pro)


¼tµP¡GQNAP«ÂÁp³q      >>ÂsÄýQNAP«ÂÁp³q¥þ³¡²£«~
«¬¸¹¡GSS-839 Pro



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQNAP«ÂÁp³q - SS-839 Pro - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºQNAP«ÂÁp³q - QNAP«ÂÁp³q¤½¥q¦æ¸¹¤Î¥ø·~¥Î¤á(SS-839 Pro)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óQNAP«ÂÁp³q¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§QNAP«ÂÁp³q²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§QNAP«ÂÁp³q­ì¼t°t¥ó


¡@

¡@

¡@

ùþ²¤¶


ùþ²¤¶

«ÂÁp³q SS-839 Pro Turbo NAS¬O·s¤@¥N¨Ï¥Î 2.5 ¦T SATA µwºÐªº¥ø·~¯Å 8-bay¦h¥\¯àNAS¦øªA¾¹¡C¨ã³ÆÀu²§ªº®Ä¯àªí²{¡BÂ×´Iªº¦øªA¾¹¥\¯à¡B·~¬É³»¯Åªº RAID¸ê®Æ«OÅ@¾÷¨î¡B¤º«ØiSCSI (internet Small Computer System Interface)¸Ë¸mªA°È¡BAES 256-bitºÏºÐ¸s²Õ¥[±K«OÅ@¾÷¨î(volume-based encryption)¥H¤Îí©wªºµwºÐ¼ö©â´«³]­pµ¥¥ø·~¤ÎªºÀ³¥Î¡C

 

¸`¯à¤Î¦wÀRªº³]­p
SS-839 Pro ¬O¥Ø«e¥«­±¤W³Ì¤pªº 8-bay NAS¡A¦]¦¹¥i»´©ö¦a°t¸m¦b¿ì¤½«Çªº¥ô¦ó¨¤¸¨¡C¥¦¦³µÛ¬Û·í¦nªº´²¼ö¤Î§C¾¸­µ³]­p¡A¬°¤@¸`¯àªºÀx¦s¸Ë¸m¡C°t³Æ 8 Áû 500 GB µwºÐ¡A³]¬° RAID 5 ªº SS-839 Pro ¯Ó¹q¶q¥u»Ý 34 W¡A¥iÀ°±z¸`¬Ù³\¦hªº¹q¶O¤ä¥X¡C

Àu²§ªº®Ä¯àªí²{»P¥iÂX¥R¡B¥i¤É¯Åªº¶i¶¥ RAID ºÞ²z¥\¯à
SS-839 Pro ·f¸üIntel Atom 1.6GHz CPU¡B2GB DDRII °O¾ÐÅé¡A¨Ã¤ä´©RAID 0/ 1/ 5/ 6/ 5 + hot spare¡ASingle¤ÎJBOD¡C¤ä´©½u¤WRAID®e¶qÂX¥R¤ÎRAID²ÕºA¾E²¾ªº¥\¯à¡C

AES 256-bit ºÏºÐ¸s²Õ¥[±K§Þ³N
°w¹ï·¥¾÷±K¸ê®Æªº°ª«×«O±Kªº»Ý¨D¡ASS-839 Pro¤ä´©AES 256-bit¥[±KºÏºÐ¸s²Õ¥\¯à¡A¨Ï¥ÎªÌ¥²¶·¿é¤J±KÆ_±K½X¤~¯à¶}±ÒºÏ°Ï¥H¦s¨ú¦øªA¾¹ªº¸ê®Æ¡A§Y¨ÏµwºÐ¤£·V¿ò¥¢¡A¥ç¥i¤£¥Î¾á¤ß¾÷±K¸ê®Æ³QÅѨú¡C

°ª¼u©Êªº iSCSI ¸Ñ¨M¤è®×
SS-839 Pro°£¤F¯à·í¤@¥x¦h¥\¯àNAS¦øªA¾¹¥H¥~¡A¤]¬O¤@¥xiSCSI target server, ¦¹¤º«Øªº±j¤j¥\¯à¡A´£¨Ñ¤@­Ó­t¾áªº°_ªºIP-SAN(Àx¦s°Ï°ìºô¸ô)¿ï¾Ü¡A¨Ã¥BµêÀÀªÅ¶¡¤À°t(Thin Provisioning)¯S¦â¡A§óÅý±z¥i¼u©Ê¤À°tiSCSI LUNªºªÅ¶¡¡A±z´N¥i¥H¬Ù¥hºÞ²z¹êÅ骺Àx¦sªÅ¶¡ªº³Â·Ð¡C

¦h¥\¯àªº¦øªA¾¹
SS-839 Pro¤ä´©¸óLinux, Unix, Mac©MWindowsªºÀɮפÀ¨É¡A¨Ã´£¨Ñ§ó¦hªº±M·~À³¥Î¡A¨Ò¦p: PHP MySQL/ SQLiteªººô¯¸¦øªA¾¹¡B¦Lªí¾÷¦øªA¾¹ (³Ì¦h¥i¦P®É¤ä´©¤T¥x)¡BÀɮצøªA¾¹µ¥¥ø·~©Ò»Ýªº¥\¯à¡CSS-839 ProµLºÃ¬O¤@­Ó¿ì¤½«Çºô¸ôªº§¹¬üÀx¦s¸Ñ¨M¤è®×¡C

»´ÃP³]©w¡A§CºûÅ@¦¨¥»
SS-839 Pro«e¤èªº LCDÅã¥Ü¿Ã¹õÅý¨Ï¥ÎªÌµL»Ý¨Ï¥Î¹q¸£¡A´N¥i¥H§Ö³t¡B²«K¦a°µRAID²ÕºAªº³]©w¡C¨Ï¥ÎªÌ¥ç¥iÂÇ¥ÑLCDÅã¥Ü¿Ã¹õ¨Ó¬d¾\¨t²Îªº°ò¥»³]©w¡C¹q·½¶}Ãö¾÷±Æµ{ºÞ²z ÅýITºÞ²z¤H­û¥i¥H¼u©Ê¦a¨Ì·Ó¤W¯Z®É¶¡¨ÓºÞ²zNAS¦øªA¾¹ªº¶}Ãö¾÷®É¶¡¡C´¼¼z«¬ªººô¸ô³ê¿ô (Wake on LAN)¥\¯à¤]¥i¥HÅý¦øªA¾¹ºÞ²zªÌ¦b°Ï°ìºô¸ô¤º¤è«K¦a»·ºÝ³ê¿ôNAS¡C

 

§C«Ø¸m¦¨¥»¤Î°ª¼u©Êªº iSCSI ¸Ñ¨M¤è®×
SS-839 Pro¯à°÷¦P®É¤ä´©NAS¤ÎiSCSI¸Ë¸m¡A´£¨Ñ¤¤¤p¥ø·~¤@­Ó­Ý¨ã§C¦¨¥»°ª¼u©Ê¤Î¦³®Ä²vªºIP-SAN¸Ñ¨M¤è®×¡CiSCSI¸Ë¸m¤ä´©°ª¹F8²Õ¡A¯à°÷§@¬° PC©Î¦øªA¾¹¤§Àx¦sªÅ¶¡ªºÂX¥R¡A¤]¥i¥H·í§@¦øªA¾¹(¦p¡G¸ê®Æ®w¦øªA¾¹¡B¹q¤l¶l¥ó¦øªA¾¹)¤§³Æ¥÷¦ì¸m¡C°w¹ïiSCSI¸Ë¸m³]©w¡ASS-839 Pro§ó´£¨Ñ¡uÀx¦s¸ê·½ÀH»Ý¤À°t¡v(Thin Provisioning)ªº¥\¯à¡C¦øªA¾¹ºÞ²z­û¯à°÷§ó¦³®Ä²vªº¦b«Ø¸miSCSI¸Ë¸mªºªì´Á¤£¨ü¹êÅé¥iÀx¦sªÅ¶¡ªº¼vÅT¡A¹w¥ý°µµêÀÀªº°t¸m¡C

AES 256-bitºÏºÐ¸s²Õ¥[±K§Þ³N
°w¹ï·¥¾÷±K¸ê®Æªº°ª«×«O±Kªº»Ý¨D¡ASS-839 Pro¤ä´©AES 256-bit¥[±KºÏºÐ¸s²Õ¥\¯à¡A¨Ï¥ÎªÌ¥²¶·¿é¤J±KÆ_±K½X¤~¯à¶}±ÒºÏ°Ï¥H¦s¨ú¦øªA¾¹ªº¸ê®Æ¡A§Y¨ÏµwºÐ¤£·V¿ò¥¢¡A¥ç¥i¤£¥Î¾á¤ß¾÷±K¸ê®Æ³QÅѨú¡C

Âù Gigabit ºô¸ôºÝ¤f¤ä´©¦h¶µ³]©w

ºô¸ô®e¿ù (Failover)
ºô¸ô®e¿ù´£¨Ñ¤F¤£¶¡Â_ªººô¸ôªA°È¡A·í¨â­Óºô¸ôºÝ¤f³£³s¤Wºô¸ô®É¡A¤@±øºô¸ô½uµo¥Í¬G»Ù°ÝÃD®É¡A¥t¤@±ø¥i¥HÄ~Äò´£¨Ñºô¸ôªA°È¡C

 

ºô¸ô­t¸ü¥­¿Å (Load-Balancing)
SS-839 Pro¤ä´©Bandwidth aggregation¡A¼W¥[Àɮתº¶Ç¿é³t²v(»Ý­n·f°t¤ä´©802.3ad³]©wªº¤A¤Ó¥æ´«¾¹)¡C

 

Âùºô¸ô IP ³]©w
SS-839 Pro ¥i¥H³]©w¨â­Ó¤£¦Pªº IP¡A¨Ã¦P®ÉªA°È¦b¨â­Ó¤£¦P¤lºô¬qªº¤u§@¸s²Õ¡C

±M·~¯Åªº°ª®Ä¯à¡B°ªÃ­©w©Ê¤Î¨ã¨aÃø¨¾½d¾÷¨îªººô¸ôÀx¦s¦øªA¾¹

¤º«Ø¦¡·L«¬µwºÐ°O¾Ð¥d(DOM)·f¸ü´O¤J¦¡¨¾Å@ªºÂù§@·~¨t²Î
¤£¦P©ó¤@¯ëNAS±N§@·~¨t²Î¦w¸Ë©ó¹êÅéµwºÐ¡ASS-839 Pro©Ò¦³ªº§@·~¨t²Î¥H¤ÎÀ³¥Î³nÅé¬Ò¤w¨Æ¥ý´O¤J¤FDOM¡C¦]¦¹±Ò°ÊSS-839 Pro®É¡A§¹¥þ¤£»Ý­nŪ¨ú¹êÅ骺µwºÐ¡A¦Ó¬OŪ¨ú¤º«ØªºDOM¡AÁקK¦]¬°µwºÐÃa­y©Î¬OÀɮ׿ù»~¦Ó³y¦¨ªºµLªk¶}¾÷²{¶H¡C´O¤J¦b·L«¬µwºÐ°O¾Ð¥dªºÂù§@·~¨t²Î¡A¤] ·|½ü¬y°õ¦æ¶}¾÷µ{§Ç¡A·í¨ä¤¤¤@®M§@·~¨t²Î¥¢®Ä®É¡A¥t¤@®M§@·~¨t²Î·|¦Û°Ê»¼¸É¤W¥B§¹¦¨¶}¾÷°Ê§@¡A¨Ã¥B°õ¦æ­×´_¥t¤@®M§@·~¨t²Îªº°Ê§@¡CÂù­««OÅ@¤§¤U¡AÅý¨t²Î³B ¦b·¥¨ÎªºÃ­©wª¬ºA¡C

¥ý¶iªºRAIDºÏºÐ°}¦CºÞ²z¤Î¤ä´©¼ö©â´«³]­p
¬°¤F½T«O¸ê®Æªº¦w¥þ©Ê¡ASS-839 Pro´£¨Ñ¥ý¶iªºRAIDºÏºÐ°}¦CºÞ²z¥\¯à¡A¥u­n³z¹L²³æ­¶­±³]©w§Y¥i»´ÃP§¹¦¨³]©w¡A¨ä¤¤¥]¬ARAID 0¡B1¡B5¡B6¡B5 + hot spare¡Bsingle¤ÎJBOD¡CSS-839 Pro¤ä´©¼ö©â´«ªº³]­p¡A´£¨Ñ±z¤£¶¡Â_»P®e©öºûÅ@ªºªA°È¡C»â¥ý·~¬Éªº RAID ºÞ²z³]­p¡A¬Û¤ñ©ó¨ä¥¦«~µPªºNAS¡A¥i¥H®e³\§ó¦h¤@ÁûªºµwºÐ·l·´¡A³o¼Ëªº³]­p¥i¥H±aµ¹¨Ï¥ÎªÌ¤@­Ó§ó¦w¥þªº¸ê®ÆÀx¦sÀô¹Ò¡C

½u¤WRAID®e¶qÂX¥R
RAID®e¶qÂX¥RÅý¨Ï¥ÎªÌ¥i¦b«O¯d©Ò¦³¸ê®Æ¡B¤£°±¾÷ªº±¡ªp¤U¡A¤@¨B¤@¨B¦a¶¶§Qªº¶i¦æRAID®e¶qÂX¥R¡C

 

 

 

½u¤WRAID²ÕºA¾E²¾
½u¤WRAID²ÕºA¾E²¾Åý¨Ï¥ÎªÌ¥i³z¹L²©ö¨BÆJ¡A¦b¤£°±¾÷¥B«O¯d¸ê®Æªºª¬ºA¤U¶i¦æRAIDµ¥¯Å¾E²¾¡C

 

 

³z¹LµêÀÀºÏºÐ ¡A¼u©ÊÂX¥R±zªº NAS ®e¶q
¸g¥Ñ¿W¯Sªº¡u¥~±µµêÀÀºÏºÐ¡v¡AºÞ²zªÌ¯à§ó¼u©Ê¦aÂX¥R NAS ªº®e¶q¡C³z¹L¤º«ØªºiSCSI initiator¥\¯à¨Ó³s±µºô¸ô¤W¨ä¥L iSCSI target¡A¥i±N¨äÅܦ¨¨t²Î¤WªºµêÀÀºÏºÐ¡CQNAP NAS ¥i°µ¬°°ïÅ|¥D¸Ë¸m (stack master) ¡A³s±µ¦h¹F 8 ­ÓµêÀÀºÏºÐ/°ïÅ|¥Ø¼Ð (stack targets)¡C¦]¦¹¡A©Ò¦³ªº NAS ¨Ï¥ÎªÌ¶È»Ý³s½u¦Ü¦¹³æ¤@¤J¤f¡A§Y¥i¨Ï¥Î¦ì©ó¨ä¥¦ºô¸ôÀx¦s¸Ë¸m¤WªºªÅ¶¡¡C

 

¤º«ØiSCSI ¸Ë¸mªA°È
¹ï¤¤¤p¥ø·~¦Ó¨¥¡A°w¹ï²{¦b¨Ï¥Î¤¤ªº¦øªA¾¹¯à°÷¾Ö¦³¤@­Ó²z·Qªº°ª®Ä¯à¤ÎÀx¦sªÅ¶¡ÂX¥R¸Ñ¨M¤è®×¬O¥²­nªº¡CµM¦Ó¡A¥Ø«e¥«­±¤W¤j³¡¤À¬ÛÃö²£«~¡A¤£¬O¤£°÷¦³®Ä²vªºÀ³ ¥Î (¦p¡GDAS¡ADirect Attached Storage) ´N¬O©Ò¶O¤£¸í¤Î¹L©ó½ÆÂø (¦p¡GFiber Channel SAN)¡C«ÂÁp³qªºSS-839 Pro ¯à°÷¦P®É¤ä´©NAS¤ÎiSCSI ¸Ë¸m¡A´£¨Ñ«Ø¸mIP-SAN¤@­Ó§C¦¨¥»¤Î¦³®Ä²vªº¸Ñ¨M¤è®×¡C¦øªA¾¹ºÞ²z­û¯à°÷¨Ï¥Î¤º«ØªºiSCSI ¸Ë¸mªA°È«Ø¥ß³Ì¦h¤K²Õ¸Ë¸m¡C¤£¦PªºiSCSIÅÞ¿è³æ¤¸¼Æ(LUNs: Logical Unit Number) ¯à°÷°µ¬°²{¦³Àx¦sªÅ¶¡ªºÂX¥R©Î¬O²{¦sÀ³¥Î¦øªA¾¹ (¦p¡G¸ê®Æ®w¦øªA¾¹¡B¹q¤l¶l¥ó¦øªA¾¹)ªº³Æ¥÷¦ì¸m¡C

¦¹¥~¡A°w¹ïiSCSI ¸Ë¸m³]©w¡ASS-839 Pro §ó´£¨Ñ¡uÀx¦s¸ê·½ÀH»Ý¤À°t¡v(Thin Provisioning) ªº¥\¯à¡C¦øªA¾¹ºÞ²z­û¯à°÷§ó¦³®Ä²vªº¦b«Ø¸miSCSIÅÞ¿è³æ¤¸¼Æ(LUN)ªºªì´Á¤£¨ü¨ì¹êÅé¥iÀx¦sªÅ¶¡ªº¼vÅT¥ý°µµêÀÀªº°t¸m¡F·í¹êÅéµwºÐªºÀx¦sªÅ¶¡§Ö­n¤£ ¨¬®É¡A¥i¥H³z¹L«ÂÁp³qNAS­ì¦³ªº¡u½u¤WRAID®e¶qÂX¥R¡vªº¥\¯à©Î¬O®Ú¾Ú»Ý¨D½Õ¾ã©Î²¾°£¥Ø«e¥¼¨Ï¥ÎªºÀx¦sªÅ¶¡¨Ó¥[¥HÂX¥R®e¶q¡C

S.M.A.R.T.¤Î¶i¶¥µwºÐª¬ºA±½´y(HHS)
Turbo NAS¤ä´©µwºÐS.M.A.R.T. (Self-Monitoring Analysis and Reporting Technology)¡A¯à°÷ºÊµøµwºÐª¬ºA¡BÀˬd¼ç¦b°ÝÃD¡A¨Ã³z¹LEmail³]©wµo¥Xĵ§i°T®§¡A´£¿ô¨Ï¥ÎªÌ¹w¥ý°µ¦n«OÅ@µwºÐ¸ê®Æªº±¹¬I¡C¦¹¥~¡ANASªº HHS (HDD Health Scanning)§Þ³N¡A¯à°÷Àˬd¨Ã±½´yµwºÐªºª¬ªp¡A¥H¹w¨¾¼ç¦b©Êªº¸ê®Æ·l¥¢¡C

²³æªº RAID ²ÕºA³]©w¤è¦¡

Touch-N-Go LCD§Ö³t¦w¸Ë
±z¥i¥H¨Ï¥Î¤è«KªºLCD¿Ã¹õ§@RAID²ÕºAªº§Ö³t¦w¸Ë¡A¥u»Ý­n¤T­Ó¨BÆJ¡A¨t²Î·|¦Û°Ê®æ¦¡¤ÆµwºÐ¥H¤Î«Ø¥ßRAID²ÕºA¡C

 

¤ä´©Windows, Mac, Linux ¤ÎUnix ¸ó¥­¥xªºÀɮפÀ¨É
Turbo NAS±Mªù³]­p¸ó¥­¥xªº¤ä´©¡A´£¨Ñ¤£¦P§@·~Àô¹Òªº¨Ï¥ÎªÌ¯à°÷»´ÃP¦a¤À¨ÉÀɮ׸ê®Æ¡C

¤ä´©Windows ADªA°È»{ÃÒ
³z¹LWindows AD ªA°Èªº»{ÃҤ䴩¡AÅý¦øªA¾¹ºÞ²zªÌ¥i¥H»´ÃP¦a±qADºô°ì¶×¤J¨Ï¥ÎªÌ±b¤á¸ê®Æ¨ìTurbo NAS¡C¤£¦ý¤j¤j¦a¸`¬Ù¤FºÞ²z­û½Æ»s±b¸¹¤Î¸s²Õªº®É¶¡¡A¨Ï¥ÎªÌ¤]¥i¥HÄ~Äò¨Ï¥Î­ì¦³ªº±b¸¹¥H¤Î±K½X¡C

ºô­¶¦¡Àɮ׺޲z¤¶­±
SS-839 Pro´£¨Ñºô­¶¦¡Àɮ׺޲z¤¶­±¡AÅý±z¥i¥H³z¹LÂsÄý¾¹»´ÃP¦a¤W¶Ç¤U¸ü¤ÎºÞ²z¦øªA¾¹¤ºªºÀɮסC

¸ê®Æ§¨ºÞ²z
ºÞ²zªÌ¥i¦b«Ø¥ß¦øªA¾¹¤§¸ê®Æ§¨®É³]©wÅã¥Ü©ÎÁôÂæ@¨É¸ê®Æ§¨¡A¥[±j¸ê®Æ«OÅ@¡C

¹q·½ºÞ²z

µwºÐ«Ý¾÷³]©w
¨Ï¥ÎªÌ¯à°÷³]©wµwºÐ¦b¯S©w®É¶¡µL¶i¦æ¸ê®Æ¦s¨ú®É§Y¶i¤J«Ý¾÷ªº³]©w¡C

¹q·½¶}Ãö¾÷±Æµ{ºÞ²z
¦¹¥\¯àÅý¨Ï¥ÎªÌ¼u©Ê¤Æ¦a³]©wNASªº¶}Ãö¾÷®É¶¡¡A±z¥i¥H¨Ì·Ó¤u§@®É¶¡¡A³]©w¦b¥ô¦ó®É¶¡§@¦Û°Ê¶}¾÷¡BÃö¾÷©Î¬O­«·s±Ò°Êµ¥¡C

UPS¤£Â_¹q¨t²Î¤ä´©
Turbo NAS¤ä´©USB¤£Â_¹q³]³Æ (usb-hid ups)¡AÅý¨Ï¥ÎªÌ¦b¥¼¹w´ÁªºÂ_¹q®É¡A¯à°÷¤Î®É°µ³B²z¡AÁקK­«­n¸ê®Æªº¿ò¥¢¡C

¤ä´©AC¹q·½¦^´_®É¡A¨t²Î¹q·½³B²z¤è¦¡³]©w
Turbo NAS¤ä´©¥«¹qÂ_¹q«á¹q·½«ì´_®É¨t²Îªº³B²z¤è¦¡¡C±z¥i¥H³]©w¦^´_¦Ü«e¤@¦¸ªº¶}¾÷©ÎÃö¾÷ª¬ºA¡C

QNAP ¿W®a³Æ¥÷³nÅé - NetBak Replicator
QNAP´£¨Ñªº¿W®a³Æ¥÷³nÅé ¡V NetBak Replicator¡AÅý¨Ï¥ÎªÌ»´ÃP¦a³Æ¥÷Windows¹q¸£¤ºªº¸ê®Æ¦ÜTurbo NAS¡A³nÅé¤ä´©§Y®É³Æ¥÷¡B¸ê®Æ¦P¨B¤Î±Æµ{³Æ¥÷µ¥¥\¯à¡C

¬Û®e²Ä¤T¤è³Æ¥÷³nÅé
QNAP NAS¬Û®e©ó¥«­±¤W¥D¬yªº³Æ¥÷³nÅé¡A¨Ò¦pAcronis True Image, CA BrightStor ARCserve Backup, EMC Retrospect, Symantec Backup Exec¤Î LaCie Silverkeeperµ¥¡C

Rsync»·ºÝ³Æ¥÷
¦bTurbo NAS¸Ì­±ªº¸ê®Æ¥i¥H»·ºÝ³Æ¥÷¨ìQNAPªºNAS¨t¦C²£«~¸Ì­±¡A©Î¬OÂÇ¥ÑRsync ³Æ¥÷¸ê®Æ¨ì¤ä´©Rsyncªº¦øªA¾¹¡C

USB³æÁä¦Û°Ê³Æ¥÷
Turbo NASªº§Ö³t«þ¨©Áä¥i¥H³]©w¬°±Ò°Ê¥ß§Y½Æ»s¥~±µUSB¸Ë¸mªº¸ê®Æ¨ìNAS¡A©Î¬O½Æ»sNASªº¯S©w¸ê®Æ§¨¨ì¥~±µUSB¸Ë¸m(³æÁä¦Û°Ê³Æ¥÷¥\¯à¥u¦³¨Ï¥ÎNAS«e¤èªºUSB port¤~¥i¥H±Ò°Ê)¡C

 

¦w¥þ¸ê®ÆÀx¦s¡B¦s¨ú¤Î¤À¨É

  • IP¦ì§}¹LÂoºÞ²z¡GºÞ²zªÌ¥i¥H¤¹³\©Î¬O©Úµ´¯S©wªºIP¦ì§}³s±µ¨ìTurbo NAS¡C
  • SSL ¦w¥þ©ÊºÞ²z (HTTPS)¡GºÞ²zªÌ¥i¥H³z¹Lºô­¶¦w¥þ¦a¦s¨ú¤ÎºÞ²z¸ê®Æ¡C
  • ³z¹LSSH (Secure Shell)¡A»·ºÝµn¤JTurbo NAS¡C
  • ¥[±K FTP¡G³z¹LSSL/ TLS (explicit) ¥[±K¨Ó¤À¨É¤Î¶Ç¿é±zªº¸ê®Æ¡C ¨Ã¥B¤ä´©FTP³Q°Ê¼Ò¦¡¤ÎÀW¼eºÞ²z¡C
  • ´¼¼z«¬FTPºÞ²z¡GºÞ²zªÌ¥i©Ò¦³FTP³s½u¤Î­Ó§O±b¸¹ªº³s½u¤W­­¡C
  • ¥[±K²§¦a³Æ´©¡GTurbo NASªº¸ê®Æ¥i¥H³z¹Lºô¸ô¥[±K³Æ¥÷¨ì¨ä¥LªºQNAP NAS¨t¦C²£«~¡C
  • FTP¼g¤J(Write-only)Åv­­³]©w¡G¦øªA¾¹ºÞ²z­û¥i¥H°w¹ï¨Ï¥ÎªÌ°µ¶È¦³³z¹LFTP¤W¶Ç¸ê®Æ¨ìNAS¦ýµLªk½s¿è©Î¬O¤U¸ü¸ê®ÆªºÅv­­³]©w¡C

ºô¸ô¦Û°ÊIP³s½u¹LÂo
¬°¨¾½dNAS¾D¨ü¨ìºô¸ô´c·N¤J«I¡A¦øªA¾¹ºÞ²z­û¯à°÷«Ø¸m¤¹³\¡B©Úµ´©Î¬O¦Û°Ê«ÊÂê³z¹LSSH/ Telnet/ HTTP(S)/ FTP/ samba/ AFPªº¦Û°Ê³s½u¹LÂo¾÷¨î¡A§ó¥[±j¤Æºô¸ôªº¦w¥þ¨¾Å@¡C

¥\¯à±j¤jªº¨t²ÎºÞ²z¤u¨ã

»·ºÝ³ê¿ô (Wake on LAN)
¨Ï¥ÎªÌ¯à°÷¥Î»·ºÝ»»±±ªº¤è¦¡³ê¿ô¦b°Ï°ìºô¸ô¤ºªºNAS¡C

´¼¼z«¬­·®°
­·®°ªºÂà³t¯à°÷®Ú¾Ú¥Ø«eªº¨t²Î·Å«×¦Û°Ê¦a°µ½Õ¾ã¡CºÞ²zªÌ¦P®É¯à°÷³z¹L¤â°Ê©w¸q°ªÂà¤Î§CÂ઺³]©w¡C

§Y®ÉSMS & Emailĵ°T³qª¾
¦øªA¾¹ºÞ²z­û¥i¥H³z¹LSMTP¤ÎSMSC(Short Message Service Center)ªº³]©w¡A¥ß§Y±µ¦¬§Y®ÉEmail¤Î²°T³qª¾¡AÀH®ÉÀH¦a»´ÃP´x´¤NASªº³Ì·sª¬ºA¡C

¤ä´©SSL (Secure Sockets Layer)¦w¥þ¾ÌÃÒ
ºÞ²zªÌ¯à°÷¤W¶Ç¸g»{¥iªº¦w¥þ¾ÌÃÒ¤ÎX.509PEM®æ¦¡ªºRSA¨p¤Hª÷Æ_Åý¨Ï¥ÎªÌ¯à°÷³z¹LSSLµn¤J¨Ó¦s¨úNASªº¸ê®Æ¡C

¤ä´©¨t²Î¤é»x(Syslog)¦øªA¾¹³]©w
³z¹L¦¹³]©w¡A©Ò¦³NASªº¨Æ¥ó°O¿ý¤Î³s½u¬ö¿ý¯à°÷³QÀx¦s¨ì»·ºÝ¨t²Î¤é»x(Syslog)¦øªA¾¹¤¤¡C

ºô¸ô¸ê·½¦^¦¬µ©
¦bNASºô¸ô¸ê®Æ§¨ùاR°£ªºÀÉ®×±N·|³Q²¾¨ì¯S©wªº¸ê·½¦^¦¬¸ê®Æ§¨¡C³z¹L³o¼Ë¥\¯à¡A±z¥i¥HÀH®É¦^¦s±z¤£¤p¤ß§R°£ªºÀɮסC

¹d²ÓÃû¿òªº¨Æ¥óºÞ²z¨t²Î
Turbo NASªº©Ò¦³³s½u°O¿ý¡A¥]¬Asamba¡BFTP¡BAFP¡BHTTP¡BHTTPS¡BTelnet¡BiSCSI¤ÎSSH¡A¥H¤Î³z¹Lºô¸ôªA°Èµn¤J¨t²Îªº½u¤W¨Ï¥ÎªÌ³s½u¸ê°Tµ¥¡AÅýºÞ²zªÌ¯à°÷®e©öºÞ²z¨Ã´x´¤©Ò¦³ªº¸Ô²Óª¬ªp¡C

¸ÔºÉªº¨t²Î¸ê°T
¦øªA¾¹ºÞ²z­û¯à°÷³z¹LºÞ²zªÌ¨Ï¥Î­¶­±´x´¤¸ÔºÉªº¨t²Î¸ê°T¡A¨Ò¦p¡GCPU¨Ï¥Î²v¡B©Ò¦³°O¾ÐÅé¤Î¥i¨Ï¥ÎªºªÅ¶¡¡Bµo°e±µ¦¬¤Î¿ù»~ªº«Ê¥]¼Æ¡B¨t²Î¶}¾÷¡BCPU·Å«×¡B¨t²Î·Å«×¡BµwºÐ·Å«×¤Î¨t²Î­·®°ªºÂà³tµ¥¡C

¦w¥þºÊ±±¤¤¤ß
Turbo NASªº¦w¥þºÊ±±¤¤¤ß(Surveillance Station)ª½±µ±ÂÅv¥i¦P®É·f°t4¤äºô¸ôÄá¼v¾÷(IP Camera)¡AÅý±z¯à°÷³z¹Lºô»Úºô¸ô³]©w¤Î°µ»·ºÝºÞ²z¡A¨ä¤¤¥]§t§Y®ÉºÊ±±¿ý¼v(real-time monitoring recording)¡B³z¹LIEÂsÄý¾¹Æ[¬Ý§Y®É¼v¹³(Live View)¡A¼½©ñ(Playback)¤Î¨Æ¥ó°O¿ý(Log)µ¥¡C¥t¥~¡A¦w¥þºÊ±±¤¤¤ß¥ç¦³¶K¤ß³]­pªº¶i¶¥¿ý¼v¥\¯à³]©w¥]§t³sÄò¿ý¼v(Continuous recording)¡B¦ì²¾°»´ú¿ý¼v (Motion-detection recording)¤Î±Æµ{¿ý¼v(Schedule recording)µ¥¡A±z¥i¥H®Ú¾Ú¤£¦P®É¬qªº»Ý¨D¡A¿ï¾Ü±ý°õ¦æªº¼Ò¦¡¡A¦b¹F¨ì¦w¥þºÊ±±»Ý¨Dªº¦P®É¡A¥ç¯à°÷­ÝÅUTurbo NAS®Ä¯à¡B¸`¬ÙµwºÐÀx¦sªÅ¶¡¤Î¹F¨ìÀô«O¸`¯àµ¥¦h­«®ÄªG¡C³z¹L¦w¥þºÊ±±¤¤¤ß¡A©Ò¦³ªº¿ý¼vÀÉ®×±N¥HAVIÀɮ׮榡Àx¦s¡A¨Ã¤ä´©®É¶¡ÂW(Time Stamp)¡A±z¥i¥H«Ü®e©ö¦a·j´MÀÉ®×¥Bª½±µ¨Ï¥ÎWindows Media Player¼½©ñ¡C

¤ä´©³Ì¼sªxºô¸ôÄá¼v¾÷«~µPªººô¸ô¦w¥þºÊ±±¤è®×
¦w¥þºÊ±±¤¤¤ß¤ä´©¥«­±¤W¦h´Ú«~µPªººô¸ôÄá¼v¾÷¨Ã³q¹L¹êÅç«ÇÄY®æªº¬Û®e©Ê»P«H¿à©Ê´ú¸Õ¡A¥]¬A¤FAXIS¡BD-Link¡BIPUX¡BLevelOne¡B Linksys¡BPanasonic ¤ÎVIVOTEKµ¥¡C·f°t¯S©w«¬¸¹ªºÄá¼v¾÷¡A¨Ï¥ÎªÌ¥ç¯à°÷³z¹Lºô­¶°õ¦æÂù¦V¼v­µºÊ±±¿ý¼v(Two-way video & audio)¡A´¼¼z«¬PTZ¾Þ§@(Pan, Tilt, Zoom)¨Ó±±¨îºÊ±±ªº¤è¦ì¡C

³nÅéÂX¥R¤Îºô¯¸ºÞ²z

ºô­¶¦øªA¾¹
Turbo NAS¤ä´©MySQL¤ÎSQLite¡A¤º«ØphpMyAdmin¤ÎJoomla!¡A±z¥i¥H»´ÃP¦a¬[³]ÄÝ©ó­Ó¤H¤Æªº¤¬°Ê¦¡ºô­¶¡C³z¹L¥i½s¿èªºphp.ini ¤ä´©¡AÅý±z¦b³]©w®É¥i¥H§K¥h¶Ç²Î¦w¸ËWindows-based¦øªA¾¹ªº³Â·Ð¡C±z¤]¥i¥H¦Û¦æ¶}µo©Î¬O¦w¸Ë¤U¸üopen-sourceªºÀ³¥Î¡A¹³¬O¬[³]Áʪ« ºô¯¸¡B½×¾Â¡Bblogµ¥¡C

MySQL¦øªA¾¹
Turbo NAS¬O±z³Ì¸gÀÙ¹ê´fªº¸ê®Æ®w¦øªA¾¹ªº¿ï¾Ü¡C¥¦¥i¥HÀ³¥Î¬°¤@¥x»·ºÝºô­¶¦øªA¾¹ªº¸ê®Æ®w¦øªA¾¹©Î§@¬°ÃB¥~ªº³Æ¥÷¸ê®Æ®w¡C

¤º«Ø¤ä´©°ÊºAºô°ì¦WºÙ¨t²Î (DDNS: Dynamic Domain Name Server)
Turbo NAS¤ä´©DDNS¡A±z¥i¥H³z¹LDDNSªA°Èªº¨ÑÀ³°Ó¡Aµù¥U¯S©wªººô°ì¦WºÙ¡A¨Ã±N¨ä«ü©w¨ìTurbo NAS¡AÅý±z³z¹Lºô°ì¦WºÙ³s½u¦Ü¨t²Î¡A¤£»Ý°O¤U¤¾ªøªºIP¦ì§}¡C

³z¹LQPKG¥­¥xÂX¥RTurbo NAS·sÀ³¥Î
QNAP¿W®aªºQPKG¥­¥xÅý¨Ï¥ÎªÌ¤£¥Î¸g¥ÑÁcÂøªºµ{§Ç¡A«K¯à°÷³z¹L²³æªº¤U¸ü»P¦w¸Ë¡A¨É¨ü¨Ó¦Û¥þ²yªÀ¸s©Ò¶}µoªº¬ÛÃö³nÅé®M¥ó¨ÓÂX¥RTurbo NASªºÀ³¥Î¡C

 


QNAP«ÂÁp³q
QNAP«ÂÁp³q¤½¥q¦æ¸¹¤Î¥ø·~¥Î¤á(SS-839 Pro) - ServerBank¸ê°T±ÄÁʺô
SS-839 Pro
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ
Hardware Spec
Hardware Spec.
CPU Intel Atom Processor 1.6 GHz
DRAM 2GB DDRII RAM
Flash Memory 128MB DOM
HDD 8 x 2.5" SATA I/II HDD, ( the standard system is shipped without HDD)
HDD Tray 8 x hot-swappable and lockable tray
LAN Port 2 x Gigabit RJ-45 Ethernet port
LED Indicators Status, LAN, USB, eSATA, HDD 1-8
USB 5 x USB 2.0 port (front: 1; back: 4)
Supports USB printer, disk, pen drive, USB hub, and USB UPS, etc.
eSATA 2 x eSATA port (back)
Buttons System: Power button, one touch copy button, reset button
LCD panel Mono-LCD display with backlight and buttons for configuration
Alarm Buzzer System warning
Form Factor Tower
Dimensions 177(H) x 180(W) x 235(D) mm
6.97(H) x 7.09(W) x 9.25(D) inch
Weight Net weight: 3.92kg/ 8.64 lb
Gross weight: 5kg/ 11.0 lb
Sound Level (dB) W/o HDD installed: 35 dB
Stand by: 34.7 dB
In operation: 35.8 dB
(Background: 24.9 dB)
Power Consumption (W) Sleep mode: 25W
In operation: 34W
(with 8 x 500GB HDD installed)
Temperature 0~40˚C/ 32~104¢XF
Humidity 0~95% R.H.
Power Supply Input: 100-240V AC, 50/60Hz, Output: 220W
Secure Design K-lock security slot for theft prevention
VGA Reserved
Fan 1 x quiet cooling fan (9 cm, 12V DC)
Software Spec.
Powerful All-in-one server
File Server File sharing across Windows/ Mac/ Linux/ Unix and centralized management
FTP Server Supports data access from remote location via FTP (max. 256 concurrent connections)
FTP with SSL/ TLS (explicit) mode
FXP supported
FTP bandwidth control and connection control
Passive FTP port range control
Backup Server QNAP client-side backup software-NetBak Replicator supports instant, schedule, and auto-sync backup
3rd party backup software support: Acronis True Image, CA Brightstor ARCserve Backup, EMC Retrospect, Symantec Backup Exec, LaCie Silverkeeper
Printer Server Network printer sharing via USB (Windows & Mac)
Supports all-in-one printer (max. 3 sets)
Remote Replication Block-level remote replication supports instant, schedule backup management; supports synchronization mode
Web Server Built-in phpMyAdmin, Joomla!, editable php.ini, SQLite and MySQL
My SQL Server Supports MySQL database server
UPnP Media Server Supports UPnP/ DLNA multimedia technology; the video, music, and photos on the NAS can be played by digital media players over the local network
Internet radio (built-in TwonkyMedia)
Media playing with PS3, Xbox360, PSP game consoles
iTunes Server iTunes server for music sharing
Smart playlist for iTunes software
Multimedia Station Image slide show and rotation (+90¢X, -90¢X)
Display photo details: dates, exposure time, aperture, etc.
Automatic thumbnail generation for easy browsing
Photo album access authority management
Multimedia files (video and audio) local playing
Automatic file categorization
Download Station PC-less BitTorrent/ FTP/ HTTP download
QNAP remote download control software:
QGet (Windows & Mac), allows you to control the download tasks of multiple Turbo NAS on one PC via LAN/ WAN
BitTorrent download supports TCP/ UDP, DHT
BT schedule download
BT download (up to 500 tasks)
Download configuration (current seed number, configurable port range, bandwidth control, download percentage, UPnP NAT port forwarding for BitTorrent download)
Download status list management (download percentage)
Supports access from Mac by Mozilla Firefox
Surveillance Station Supports 4 IP cameras (optional purchase) for network surveillance
Software Specifications
Operating System Linux-embedded system
Networking TCP/IP, DHCP Client, DHCP Server, CIFS/SMB, AFP, NFS, HTTP, HTTPS, FTP, DDNS, NTP
Multi-IP setting
Gigabit Jumbo Frame
Port Trunking
- Balance-rr (Round-Robin)
- Active Backup
- Balance XOR
- Broadcast
- IEEE 802.3ad
- Balance-tlb (Adaptive Transmit Load Balancing)
- Balance-alb (Adaptive Load Balancing)
Network Service Discovery (UPnP & Bonjour)
File System EXT3 (Internal/ external HDD)
EXT4 (Internal/ external HDD)
FAT (External HDD)
NTFS (External HDD)
Supported Operating Systems Microsoft Windows 98/ ME/ NT/ 2000/ XP/ 2003/ Vista
Mac OS X
Linux
Unix
Disk Management Single disk, RAID 0, RAID 1, RAID 5, RAID 5 + hot spare, RAID 6, and JBOD (Linear Disk Volume)
Multiple RAID
Online RAID Capacity Expansion
Online RAID Level Migration
Disk usage status management
Check disk (Check Linux file system)
HDD S.M.A.R.T.
Bad blocks scan
PC-less RAID setup via LCD panel for the first time installation (Touch-N-Go)
AES 256-bit volume-based encryption
Built-in iSCSI target service
RAID Recovery
Virtual Disk
User Management User quota management (per user)
Windows AD
User account management (max. 4,096 users)
User group management (max. 512 groups)
Batch creating users
File System Management Network share management (max. 512 shares)
Network volume status management
Share folder level ACL support
Hide share folder on Windows network
Unicode support
Journaling file system
Web File Manager
System Tools E-mail alert (SMTP authentication)
SMS alert
HDD standby mode
Disk usage alert
Automatic power on after power loss
QPKG add-on firmware supported
System firmware upgrade
Back up, restore, reset system settings
Smart fan setting
Configurable management port
Policy-based unauthorized IP blocking
Secure remote login by SSH connection
Remote login by Telnet connection
USB, SNMP UPS support
Wake on LAN
Schedule power on/ off (max. 15 settings)
Network recycle bin
Import SSL certificate
SNMP
Real-time System Resource Monitor
LCD RAID configuration for the first time setup
When the system is ready, users can check or configure the IP settings, physical disk info, volume info, system info, shut down or reboot the NAS, etc.
Event Logs Complete system logs (file level): system events management, connection logs, current connection of on-line users
Multilingual Support English, Traditional Chinese, Simplified Chinese, Japanese, Korean, French, German, Italian, Spanish, Russian, Swedish, Norwegian, Finnish, Danish, and Polish
Backup Management PC-client backup software-NetBak Replicator: Instant/ Schedule/ Auto-sync backup
Remote replication supports Rsync
Encrypted remote replication
USB one touch copy backup
Data backup to external storage devices
Multi-browser support Internet Explorer 7 & 8
Safari 3 & 4
Firefox 3
Google Chrome

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQNAP«ÂÁp³q - SS-839 Pro - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºQNAP«ÂÁp³q - QNAP«ÂÁp³q¤½¥q¦æ¸¹¤Î¥ø·~¥Î¤á(SS-839 Pro)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@