­º­¶> ¦øªA¾¹Àx¦s¿ïÁÊ«~>ºÏºÐ°}¦C¥dRaidCard>SATA Raid

>>ÂsÄý©Ò¦³Promise³ì¹©¦øªA¾¹Àx¦s¿ïÁÊ«~>

Promise³ì¹©
SATA RAID 0/1/5/10 ºÏºÐ°}¦C¥d

«¬¸¹¡GFastTrakTX4310


Promise³ì¹©FastTrakTX4310


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºPromise³ì¹© - FastTrakTX4310 - ¦øªA¾¹Àx¦s¿ïÁÊ«~>
³Ì¦nªºPromise³ì¹© - SATA RAID 0/1/5/10 ºÏºÐ°}¦C¥d±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Ú¦øªA¾¹Àx¦s¿ïÁÊ«~>ºÏºÐ°}¦C¥dRaidCard>SATA Raid Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óPromise³ì¹©¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§Promise³ì¹©²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§Promise³ì¹©­ì¼t°t¥ó


¡@

¡@

¡@

FastTrak TX4310²£«~¯S¦â¡G

  • 4 °ð Serial ATA 3Gb/s ºÏºÐ°}¦C¥d

  • ¤ä´© RAID 0/1/5/10 ¤Î JBOD

  • ¤ä´© 32-Bit / 66 MHz PCI ¤¶­±

  • ¤ä´© ­ì¥Í©R¥O¦î¦C«ü¥O¶° (Native Command Queuing¡FNCQ)

  • ´£¨Ñ¤j©ó137GB¥H¤WµwºÐ Large LBA ¤ä´©

  • ¤ä´©µwºÐ¹B§@ª¬ªpLEDÅã¥Ü¸Ë¸m

  • ¥i·f°t SuperSwap 1100©MSuperSwap 4100¡A»´ÃP¤É¯Å¬°§ó¥ý¶iªº¤º±µ¦¡Àx¦s¨t²Î

·¥¨ã¸gÀٮįqªº SATA RAID 0/1/5/10 PCI¤¶­±ºÏºÐ°}¦C¥d

4°ð FastTrak TX4310 SATA PCI¤¶­±ºÏºÐ°}¦C¥d¡A¥H·¥¨ã§l¤Þ¤Oªº»ù®æÀu¶Õ¡A¤ä´©°ª¹F¥|­Ó°ª®Ä¯à SATA µwºÐ¡AÅý¨Ï¥ÎªÌ»´ÃP«Ø¸m RAID 0¡B1¡B5¡B10 Àx¦s¨t²Î¡C¥þ²y SATA ¸Ñ¨M¤è®×»â¾É¼t°Ó³ì¹©¸ê°T¡A¥H²Ö¿n¦h¦~ªºÂ×´I¸gÅç©Ò±À¥Xªº FastTrak TX4310 ¡A±NÅý±zºÉ¨É SATA ¦s¨t²Îªº®Ä¯àÀu¶Õ¡C

 

¸gÅçÃÒªº FastTrak RAID ¤ÞÀº

FastTrak TX4310 ¥H³q¹L¥«³õÅçÃÒªº RAID 0/1/5/10 ³nÅé¤ÞÀº¡A¬°±z±a¨Ó§Ö³t¡B°ª®Ä¯à¤S¥i¾aªººÏºÐ°}¦C®e¿ù«OÅ@¡CRAID 0 ´£¨Ñ°ª®e¶q¤Î³Ì¤j®Ä¯à¡FRAID 1 ¨ã³Æ¸ê®Æ«OÅ@¥\¯à¡FRAID 5 ¥i­ÝÅU¸ê®Æ«OÅ@»P®Ä¯à­n¨D¡F¦Ó·f°t¥|ÁûµwºÐªºRAID 10¡A«h¥i¦b«OÅ@¸ê®Æªº¦P®É¡A¶i¤@¨B±j¤Æ®Ä¯à¡C³ì¹©ªº RAID ¤ÞÀº¥ç´£¨Ñ°ª³t±Æ¦C·j´M¾÷¨î(elevator seek)¤Î­t¸ü¥­¿Å³Ì¨Î¤Æ(load balancing)µ¥§Þ³N¨Ó¼W¥[®Ä¯à¡CFastTrak¥ç¤ä´©©ó­I´º¤¤°õ¦æªº³z³q¸ê®Æ(transparent data)´_­ì¤ÎµwºÐ­««Øµ¥¯S©Ê¡A¨ÏºÏºÐ°}¦C¯à«ùÄò¤£¶¡Â_¦a¹B§@¡C

 

¤ä´© SATA 3Gb/s

FastTrak TX4310 ºÏºÐ°}¦C¥d¤ä´© SATA 3Gb/s µwºÐ¡A²Å¦X Serial ATA II ¨Ã¤U¦V¬Û®e SATA 1.0a ³W®æ¡A¤ä´©­ì¥Í©R¥O¦î¦C«ü¥O¶°(Natvie Command Queuing;NCQ)»PµwºÐ¹B§@ª¬ªp LED Åã¥Ü¸Ë¸m¡C­ì¥Í©R¥O¦î¦C«ü¥O¶°(Natvie Command Queuing;NCQ)¯àÁo©ú¦a±N¸ê®Æ­n¨D­«·s±Æ§Ç¡AÅý¸ê®Æ¥i¥H¤ñ­ì¥ý¥¼±Æ§Ç«e§ó§Öªº³Q¦s¨ú¡A¶i¦Ó´£ª@I/O®Ä¯à¡C

 

¥ý¶iªºHBA¯S©Ê

±Älow-profile³]­pªºFastTrak TX4300¨ã³Æ¦h¶µ¥ý¶iªº¥D¾÷¶×¬y±Æ¤¶­±¥d¯S©Ê¡G66MHz PCI ¶×¬y±Æ¤¶­±¤ä´©°ª¹F 266MB/sec ªºÀþ¶¡¸ê®Æ¶Ç¿é³t²v¡F°w¹ï 137GB ¥H¤WµwºÐ´£¨Ñ large LBA ¤ä´©¡A¦¹¥~¡A¨ä·f¸üªº BIOS ¥i¦Û°Ê¿ëÃѨó]©wµwºÐºØÃþ¡C


Promise³ì¹©
SATA RAID 0/1/5/10 ºÏºÐ°}¦C¥d - ServerBank¸ê°T±ÄÁʺô
FastTrakTX4310
¦øªA¾¹Àx¦s¿ïÁÊ«~>ºÏºÐ°}¦C¥dRaidCard>SATA Raid


¡@
²£«~³W®æ

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºPromise³ì¹© - FastTrakTX4310 - ¦øªA¾¹Àx¦s¿ïÁÊ«~> ,³Ì¦nªºPromise³ì¹© - SATA RAID 0/1/5/10 ºÏºÐ°}¦C¥d±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 ·Ç¨t²ÎBarebone
 Adapter
 smart array ±±¨î¾¹
 Server Board
 WorkStation Board
 smart array °t¥ó
 raid cable
 CPU
 Xeon 3.4G
 Xeon 2.8G
 Xeon 3.6G
 Xeon 5130(2.0G)
 XEON 5140(2.33G)
 Xeon 5110(1.6G)
 Xeon 5120(1.83G)
 Xeon 5050 (3.0G)
 Xeon 5160 (3.0G)
 DualCore 2.0
 DualCore 2.2
 Xeon 5060(3.2G)
 Xeon MP
 Xeon 64
 DualCore 1.8
 Xeon 5150(2.66G)
 DualCore 2.4
 DualCore 2.6
 DualCore 2.8
 XEON 5080(3.73G)
 ¥|®Ö¤ß
 Opteron DC 1.8G 2210
 Opteron DC 2.0G 2212
 Opteron DC 2.2G 2214
 Opteron DC 2.4G 2216
 Opteron DC 2.6G 2218
 Opteron DC 2.8G 2220
 Opteron DC 2.0G 8212
 Opteron DC 2.2G 8214
 Opteron DC 2.6G 8218
 Opteron DC 2.8G 8220
 PD 3.0G
 P4 3.2G
 Single core 250 2.4g
 Single core 252 2.6g
 Single core 254 2.8g
 Single core 150 2.4g
 Single core 152 2.6g
 Single core 154 2.8g
 P4 3.06G
 P4 2.8G
 Woodcrest 5130
 Woodcrest 5140
 Woodcrest 5160
 PD 3.4G
 PD 3.2G
 Xeon 3.06G
 Xeon 2.4G
 AMD¬[ºc
 Xeon 3.2G
 E6300
 E6400
 E6600
 E6700
 Itanium 2
 RAM°O¾ÐÅé
 PC2100 | DDR266
 ECC
 ECC Register
 £¸¯ë
 PC2700 | DDR333
 ECC
 ECC Register
 £¸¯ë
 PC3200 | DDR400
 ECC
 ECC Register
 £¸¯ë
 PC4200 | DDR2 533
 ECC
 ECC Register
 £¸¯ë
 PC1600
 ¤@¯ë
 ECC Register
 ECC
 FB-DIMM
 Kingston ¦øªA¾¹°O¾ÐÅé
 PC2-5300 | DDR2
 ECC
 ECC Register
 £¸¯ë
 HardDisk
 SATA«D¼ö©â
 SATA¼ö©â
 SCSI«D¼ö©â
 SCSI¼ö©â
 SATA¢º«D¼ö©â
 SATA¢º¼ö©â
 IDE
 SAS
 ºÏºÐ°}¦C¥dRaidCard
 SCSI Raid
 SATA Raid
 SATA¢º Raid
 SAS Raid
 ºô¸ô¥d
 Åã¥Üø¹Ï¥d
 ­·®°Fan
 ¹q·½¨ÑÀ³¾¹Power
 °Æ¼t°O¾ÐÅé
 °Æ¼tµw¿Ò
 °Æ¼t SCSI card
 °Æ¼t Raid card
 ±Æ½u
 Âà¾÷¬[®M¥ó
 ¹q¸£¾÷½c
 §@·~¨t²Î
 ¦w¸Ë
 ºûÅ@
 ¨ä¥L¿ïÁÊ°t¥ó
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > ¦øªA¾¹Àx¦s¿ïÁÊ«~>ºÏºÐ°}¦C¥dRaidCard>SATA Raid


Promise³ì¹©FastTrakTX4310

SATA RAID 0/1/5/10 ºÏºÐ°}¦C¥d


¼tµP¡GPromise³ì¹©      >>ÂsÄýPromise³ì¹©¥þ³¡²£«~
«¬¸¹¡GFastTrakTX4310



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºPromise³ì¹© - FastTrakTX4310 - ¦øªA¾¹Àx¦s¿ïÁÊ«~> ,³Ì¦nªºPromise³ì¹© - SATA RAID 0/1/5/10 ºÏºÐ°}¦C¥d±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Ú¦øªA¾¹Àx¦s¿ïÁÊ«~>ºÏºÐ°}¦C¥dRaidCard>SATA Raid Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óPromise³ì¹©¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§Promise³ì¹©²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§Promise³ì¹©­ì¼t°t¥ó


¡@

¡@

¡@

FastTrak TX4310²£«~¯S¦â¡G

  • 4 °ð Serial ATA 3Gb/s ºÏºÐ°}¦C¥d

  • ¤ä´© RAID 0/1/5/10 ¤Î JBOD

  • ¤ä´© 32-Bit / 66 MHz PCI ¤¶­±

  • ¤ä´© ­ì¥Í©R¥O¦î¦C«ü¥O¶° (Native Command Queuing¡FNCQ)

  • ´£¨Ñ¤j©ó137GB¥H¤WµwºÐ Large LBA ¤ä´©

  • ¤ä´©µwºÐ¹B§@ª¬ªpLEDÅã¥Ü¸Ë¸m

  • ¥i·f°t SuperSwap 1100©MSuperSwap 4100¡A»´ÃP¤É¯Å¬°§ó¥ý¶iªº¤º±µ¦¡Àx¦s¨t²Î

·¥¨ã¸gÀٮįqªº SATA RAID 0/1/5/10 PCI¤¶­±ºÏºÐ°}¦C¥d

4°ð FastTrak TX4310 SATA PCI¤¶­±ºÏºÐ°}¦C¥d¡A¥H·¥¨ã§l¤Þ¤Oªº»ù®æÀu¶Õ¡A¤ä´©°ª¹F¥|­Ó°ª®Ä¯à SATA µwºÐ¡AÅý¨Ï¥ÎªÌ»´ÃP«Ø¸m RAID 0¡B1¡B5¡B10 Àx¦s¨t²Î¡C¥þ²y SATA ¸Ñ¨M¤è®×»â¾É¼t°Ó³ì¹©¸ê°T¡A¥H²Ö¿n¦h¦~ªºÂ×´I¸gÅç©Ò±À¥Xªº FastTrak TX4310 ¡A±NÅý±zºÉ¨É SATA ¦s¨t²Îªº®Ä¯àÀu¶Õ¡C

 

¸gÅçÃÒªº FastTrak RAID ¤ÞÀº

FastTrak TX4310 ¥H³q¹L¥«³õÅçÃÒªº RAID 0/1/5/10 ³nÅé¤ÞÀº¡A¬°±z±a¨Ó§Ö³t¡B°ª®Ä¯à¤S¥i¾aªººÏºÐ°}¦C®e¿ù«OÅ@¡CRAID 0 ´£¨Ñ°ª®e¶q¤Î³Ì¤j®Ä¯à¡FRAID 1 ¨ã³Æ¸ê®Æ«OÅ@¥\¯à¡FRAID 5 ¥i­ÝÅU¸ê®Æ«OÅ@»P®Ä¯à­n¨D¡F¦Ó·f°t¥|ÁûµwºÐªºRAID 10¡A«h¥i¦b«OÅ@¸ê®Æªº¦P®É¡A¶i¤@¨B±j¤Æ®Ä¯à¡C³ì¹©ªº RAID ¤ÞÀº¥ç´£¨Ñ°ª³t±Æ¦C·j´M¾÷¨î(elevator seek)¤Î­t¸ü¥­¿Å³Ì¨Î¤Æ(load balancing)µ¥§Þ³N¨Ó¼W¥[®Ä¯à¡CFastTrak¥ç¤ä´©©ó­I´º¤¤°õ¦æªº³z³q¸ê®Æ(transparent data)´_­ì¤ÎµwºÐ­««Øµ¥¯S©Ê¡A¨ÏºÏºÐ°}¦C¯à«ùÄò¤£¶¡Â_¦a¹B§@¡C

 

¤ä´© SATA 3Gb/s

FastTrak TX4310 ºÏºÐ°}¦C¥d¤ä´© SATA 3Gb/s µwºÐ¡A²Å¦X Serial ATA II ¨Ã¤U¦V¬Û®e SATA 1.0a ³W®æ¡A¤ä´©­ì¥Í©R¥O¦î¦C«ü¥O¶°(Natvie Command Queuing;NCQ)»PµwºÐ¹B§@ª¬ªp LED Åã¥Ü¸Ë¸m¡C­ì¥Í©R¥O¦î¦C«ü¥O¶°(Natvie Command Queuing;NCQ)¯àÁo©ú¦a±N¸ê®Æ­n¨D­«·s±Æ§Ç¡AÅý¸ê®Æ¥i¥H¤ñ­ì¥ý¥¼±Æ§Ç«e§ó§Öªº³Q¦s¨ú¡A¶i¦Ó´£ª@I/O®Ä¯à¡C

 

¥ý¶iªºHBA¯S©Ê

±Älow-profile³]­pªºFastTrak TX4300¨ã³Æ¦h¶µ¥ý¶iªº¥D¾÷¶×¬y±Æ¤¶­±¥d¯S©Ê¡G66MHz PCI ¶×¬y±Æ¤¶­±¤ä´©°ª¹F 266MB/sec ªºÀþ¶¡¸ê®Æ¶Ç¿é³t²v¡F°w¹ï 137GB ¥H¤WµwºÐ´£¨Ñ large LBA ¤ä´©¡A¦¹¥~¡A¨ä·f¸üªº BIOS ¥i¦Û°Ê¿ëÃѨó]©wµwºÐºØÃþ¡C


Promise³ì¹©
SATA RAID 0/1/5/10 ºÏºÐ°}¦C¥d - ServerBank¸ê°T±ÄÁʺô
FastTrakTX4310
¦øªA¾¹Àx¦s¿ïÁÊ«~>ºÏºÐ°}¦C¥dRaidCard>SATA Raid


¡@
²£«~³W®æ

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºPromise³ì¹© - FastTrakTX4310 - ¦øªA¾¹Àx¦s¿ïÁÊ«~> ,³Ì¦nªºPromise³ì¹© - SATA RAID 0/1/5/10 ºÏºÐ°}¦C¥d±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@