|
ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô >
ºô¸ô³]³Æ/ÀW¼eºÞ²z
|
|
|
¡@ |
Cisco WS-C2950-24ºô¸ô°ò¦«Ø³]¥æ´«¾¹Switch - ServerBank¸ê°T±ÄÁʺô WS-C2950-24ºô¸ô°ò¦«Ø³]¥æ´«¾¹Switch ºô¸ô³]³Æ/ÀW¼eºÞ²z
¡@
²£«~¦WºÙ
|
WS-C2950-24 |
¯S¦â
|
²£«~¯S¦â´yz
- Cisco Catalyst® 2950
¨t¦C¬O¤@³¡©T©w³s±µ°ð¼Æ¡B½u³t¥æ´«¶Ç¿éªº°ª³t¤A¤Óºô¸ô®à¤W«¬¥æ´«¾¹¡A¥i´£¨Ñ°Ï°ìºô¸ô(LAN) ªºµ´¨Î®Ä¯à»P¥\¯à¡C³o¨Ç¿W¥ß¡B10/100
¦Û°Ê°»´úªº¥æ´«¾¹¡A³z¹L®e©ö¨Ï¥Î¡BÂsÄý¾¹¤¶±ªºCisco ÂO¶°ºÞ²z®M¥ó(Cluster Management Suite,
CMS)»P¾ã¦X¦¡ªºCisco IOS® ³nÅé¶i¦æºÞ²z¡A¥i¼W±jªA°Èªº«~½è(QoS)
»P¦hÂI¸s¼½(Multicast)ªººÞ²z¥\¯à¡CCatalyst 2950 Gigabit-over-copper
ª©¥»·f°t10/100/1000BaseT ¦V¤WÃìµ²³s±µ°ð¡A¥i¬°¤¤¤p«¬¥ø·~»P¥ø·~¤À¤½¥q´£¨Ñ¤@®M²z·Qªº¸Ñ¨M¤è®×¡A¥H¨Ï¥Î²{¦³ªºCAT. 5
»É½u¡A±q²{¦³ªº§Ö³t¤A¤Óºô¸ô(Fast Ethernet)¤É¯Å¬°°ª®Ä¯àªº¡u¶W°ª³t¤A¤Óºô¸ô¬[ºc¡v(Gigabit Ethernet
backbone)¡C
Catalyst 2950 ¨t¦C¥]§tCatalyst 2950T-24,2950-24, 2950-12 »P2950C-24
¥æ´«¾¹¡CCatalyst 2950-24 ¥æ´«¾¹¥i´£¨Ñ24 Ó10/100 ¥æ´«°ð¡FCatalyst 2950-12 «h¦³12
Ó10/100 ¥æ´«°ð¡FCatalyst 2950T-24 «¬¦³24Ó10/100 ¥æ´«°ð»P2 Ó©T©wªº10/100/1000BaseT
¦V¤WÃìµ²³s±µ°ð¡F¦Ü©óCatalyst 2950C-24 «¬«h¦³24 Ó10/100 ¥æ´«°ð»P2Ó©T©w100BaseFX
¦V¤WÃìµ²³s±µ°ð¡C¨C´Ú¥æ´«¾¹³£¥u¦û1Uªº¾÷ÂdªÅ¶¡¡A°t¸m®É§ó¨ã¦³¼u©Ê¡A¥i©ñ¸m¦b®à±©Î¬[³]¦b°t½u½c¤º¡C
¥HÆl½u³t«×¡]wire-speed ¡^®Ä¯à³s±µ²×ºÝ¯¸¥x»P°Ï°ìºô¸ôCatalyst 2950¥æ´«¾¹¨C¬í¥æ´«³t«×¥i¹F8.8Gigabits
(Gbps)¡B³Ì°ª¶Ç°eÀW¼e4.4 Gbps¡A
¥i¦b©Ò¦³³s±µ°ð´£¨Ñ½u³t®Ä¯à¡A¥H³s±µ²×ºÝ¯¸¥x¡B¨Ï¥ÎªÌ»P¥ø·~ªº°Ï°ìºô¸ô¡CCatalyst 2950 ¥æ´«¾¹¤ä´©¨ä¥¦´£¤É®Ä¯àªº¯S©Ê¡A¦pFast
EtherChannel ® »PGigabit EtherChannel §Þ³N¡A¬°Catalyst
¥æ´«¾¹¡B¸ô¥Ñ¾¹»P¦øªA¾¹¶¡¡A´£¨Ñ°ª¹F4-Gbps ªº°ªÀW¼e®Ä¯à¡C
·Q¦b¨Ï¥ÎCAT. 5
»É½u(UTP½u¸ô)¬[ºcªº¤¤«¬¥ø·~¤¤¤É¯Å¦Ü¶W°ª³t(Gigabit)ªº°Ï°ìºô¸ô(LAN)¡A²{¦b¥i¥H¿ï¾Ü¤@¶µ«Ü§l¤Þ¤Hªº¸Ñ¨M¤è®×¡A¨Ï¨äLAN
¯à±q²{¦³ªº¶Ç¿é³t²v¡A¨³³t¤É¯Å¦ÜGigabit ªº¶Ç¿é³t²v¡CCatalyst 2950T-24 ´£¨Ñ¨âÓ©T©wªº10/100/
1000BaseT(¥H»ÉÆl½uºô¸ô¨Ó¬[³]¤§¶W°ª³t¤A¤Óºô¸ô)¦V¤WÃìµ²³s±µ°ð¡AÁÙ¦³24 Ó10/100
¥æ´«°ð¥i¨Ñ®à±²×ºÝ¯¸¥x³s½u¨Ï¥Î¡C¥un¨CÓ°ð¦h´£¼·¤@¨Ç¶O¥Î¡A¤¤«¬¥ø·~²{¦b´N¯à¨Ï¨äLAN
¤É¯Å¬°°ª®Ä¯àªº¶W°ª³t¤A¤Óºô¸ô¡C¦Ó·í³s±µ·s«¬ªºCatalyst 3550-12T¦h¼h¯Å¶W°ª³t¤A¤Óºô¸ô¥æ´«¾¹®É¡ACatalyst
2950T-24 ¥æ´«¾¹´N¯à´£¨Ñ¤@®M¥H»ÉÆl½uºô¸ô¨Ó¬[³]¤§¶W°ª³t¤A¤Óºô¸ô( Gigabit
-Ethernet-over-copper)ªº¾ã¦X¦¡¸Ñ¨M¤è®×¡A¹ï©ó¤w¤£¦A¾A¥Î즳¤§°ª³t¤A¤Óºô¥D·Fªº¤¤«¬¥ø·~¦Ó¨¥¡A«D±`¾A¦X¡C
- Quality of Service(QoS)
Catalyst 2950 ¨t¦C´£¨ÑÀu¨}ªº°Ï°ìºô¸ôºÝ(VAN-edge)
QoS¡A¬O¥Í²£¦PÃþ²£«~ªº¦P·~Ì©ÒµLªk¤ñÀÀªº¡C©Ò¦³Catalyst 2950 ¥æ´«¾¹¬Ò¥i¤ä´©¨âºØ¼Ò¦¡ªº¤ÀÃþ¡A¤@ºØ¼Ò¦¡¬O¥HIEEE
802.1p ¼Ð·Ç¬°°ò¦¡A¦b¤J¤fÂI´£¨ÑªA°Èµ¥¯Å(class-of-service,
CoS)È¡A¨Ã¤À°t«Ê¥]µ¹¾A·íªº¦î¦C¡F¦Ó¦b²Ä¤GºØ¼Ò¦¡¤¤¡A«Ê¥]·|®Ú¾Úºô¸ôºÞ²zû¹w¥ý¤À°tµ¹¤J¤fÂIªº¹w³]CoS
È¡A¶i¦æ«·s¤ÀÃþ¡C·í¦¬¨ì¨S¦³CoS Ȫº°T®Ø(¦p¨S¦³¼Ð°Oªº°T®Ø)®É¡ACatalyst 2950
¥æ´«¾¹´N·|®Ú¾Úºô¸ôºÞ²zû¹w¥ý¤À°tµ¹¨CӰ𪺹w³]CoS È¥[¥H¤ÀÃþ¡C
¤@¥¹°T®Ø§Q¥Î¤Wz¨ä¤¤¤@ºØ¼Ò¦¡¶i¦æ¤ÀÃþ©Î«·s¤ÀÃþ«á¡A´N·|³Q¤À°t¦Ü¾A·íªº¥X¤f¦î¦C¡CCatalyst 2950
¥æ´«¾¹¥i¤ä´©¥|Ó¥X¤f¦î¦C¡AÅýºô¸ôºÞ²zû¯à§ó²M·¡¤F¸ÑLAN ¬y¶q¤£¦P¤§À³¥Îµ{¦¡ªº«ü¬£Àu¥ýÅv¡CÄY®æªºÀu¥ýÅv±Æ§Ç(Priority
Scheduling)°t¸m¯à½T«O¦p»yµµ¥¹ï®É¶¡±Ó·P«×¸û°ªªºÀ³¥Îµ{¦¡¡A¦Ó¯à¥Ã»·¥H³Ì¨³³tªº¸ô®|¬ï³z¥æ´«¾¹µ²ºc¡CÅv«´`Àô(Weighted
Round Robin, WRR)±Æ§Ç¬O¥t¤@¶µ«nªº´£¤É¥\¯à¡A¨ä¥i½T©wÀu¥ýÅv¸û§Cªº¬y¶q¯à¨ü¨ìª`·N¡A¤£¥]§tºô¸ôºÞ²z¤H©ÒºÞ²zªºÀu¥ýÅv³]©w¡C
³o¨Ç¯S¦â¯àÅýºô¸ôºÞ²zû¹ï³B²z«n¥ô°È(missioncritical)ªº¬y¶q¡B®É¶¡±Ó·P«×¸û°ªªº¬y¶qµ¹¤©Àu¥ýÅv¡A¦pERP (Oracle,
SAP µ¥µ¥)¡B»yµ(ºô¸ô¹q¸Ü¬y¶q)¡A
¨Ã¯àÝÅU¹ï®É¶¡±Ó·P«×¸û§C(time-sensitive)ªºÀ³¥Îµ{¦¡¦pFTP ©Îe-mail (SMTP)
ªº¹q¸£»²§U³]p»P¹q¸£»²§U»s³y(CAD/CAM)µ¥¡C
- ³z¹LIGMP Snooping ¶i¦æ¦hÂI¸s¼½ºÞ²z
ºô»Úºô¸ô¸s²ÕºÞ²z¨ó©w(Internet Group Management Protocol,
IGMP)ªº¼ÒÀÀ(Snooping)¥\¯à¡A¯àÅý¥æ´«¾¹¡u²âÅ¥¡v¥D¾÷»P¸ô¥Ñ¾¹¶¡ªºIGMP ¹ï¸Ü¡C·í¥æ´«¾¹Å¥
¨ì¥D¾÷¶Ç°e¹L¨ÓªºIGMP¡An¨D¥[¤J¯S©wªº¦hÂI¸s¼½¸s²Õ®É¡A¥æ´«¾¹´N·|±N¸Ó¥D¾÷°ðªº¸¹½X¥[¤J¸Ó¸s²Õªº¸s²Õ¥Øªº¦ì§}(Group
Destination Address, GDA)¦W³æ¡C¦Ó¥B¡A·í¥æ´«¾¹Å¥¨ì¥D¾÷¶Ç°eªºIGMP
Â÷¶}n¨D®É¡A¥¦´N·|±N¸Ó¥D¾÷°ðªº¸¹½X±q¤º®e¥i´M§}°O¾ÐÅé(Content Addressable Memory, CAM)ªí¶µ¤¤²¾°£¡C
ÂǵۦbµwÅ餤¤ä´©IGMP Snooping ¡A¨Ã³z¹LCiscoÂO¶°ºÞ²z®M¥ó(CMS)°t¸mIGMP Snooping¡ACatalyst
2950 ¥æ´«¾¹´N¯à´£¨Ñ¨ô¶Vªº®Ä¯à¡A¨Ã¨ÏLAN ¤W¦hÂI¼½°eÀ³¥Îµ{¦¡ªººÞ²z§@·~Åܱo§ó®e©ö¡C
- Cisco ÂO¶°ºÞ²z®M¥ó
(Cluster Management Suite)
Cisco ÂO¶°ºÞ²z®M¥ó(CMS)¬O¤@®M¥HÂsÄý¾¹¤¶±ºÞ²zªº(Web-based)³nÅé¡A¤º«Ø©óCatalyst 2950
¡B3550-12T ¡B3500 XL ¡B2900 XL ¡B»P1900 ¥æ´«¾¹¤¤¡C³z
¹LCisco ¥æ´«¾¹ÂO¶°§Þ³N¡A¨Ï¥ÎªÌ¥i¥H³æ¤@IP ¦ì§}¡A¥Î¥ô¦ó¼Ð·Ç¦¡ªººô¸ôÂsÄý¾¹¨Ó¦s¨úCMS ¡A¨ÃºÞ²z¦h¹F16
¥x¬Û¤¬³s±µªºCatalyst 2950, 3550-12T, 3500 XL, 2900 XL, »P1900
¥æ´«¾¹¡A¦Ó¤£ºÞ¨ä¹ê»Úªº¦a²z¦ì¸m¬O§_¬Û¾F¡CCMS ´£¨Ñ¤@Ó¾ã¦X©Ò¦³Cisco
ºô¸ô§@·~¨t²Î(IOS)¥\¯à»P¶´ÅéºÞ²zªººÞ²z¤¶±¡A¨Ã¥i´£¨ÑºÞ²zû¤@Ó±j¤jªº¹Ï§Î¨Ï¥ÎªÌ¤¶±(GUI)¤u¨ã¡A¥H»´©öºÊ±±¨ÃºÞ²z¨äLAN ¡CCMS
¥i¤ä´©¼sªxªº¼Ð·Ç
¦¡³s½u¿ï¶µ»P²ÕºA³]©w¡A¶Ç»¼¥iÂX¥Rªº®Ä¯à¡A¥H²Å¦XÅU«È»Ý¨D¡CCatalyst 2950
¥æ´«¾¹ªº¥æ´«¾¹ÂO¶°³s½u¿ï¶µ¡A¥]¬A¡G¤A¤Óºô¸ô¡B°ª³t¤A¤Óºô¸ô¡BFast EtherChannel ¡BGigabit Ethernet
(1000BaseT) »PGigabit EtherChannel ³s½u¡C¦]¬°¦¹§Þ³N¨Ã¤£¨ü©ó±M¦³ªº°ïÅ|¼Ò²Õ©Î°ïÅ|Æl½u¡A©Ò¥HCMS
¥iÂX¥R¶Ç²Îªº
ÂO¶°ºô°ì¡A¨Ï¨ä¤£¨ü³æ¤@°t½u½cªº¨î¡A¨ÃÅý¨Ï¥ÎªÌ²V¦X»P°t¹ï¥æ¤¬ªº³s½u¡A¥H¦]À³¯S®íªººÞ²z¡B®Ä¯à»P¦¨¥»»Ý¨D¡C
Catalyst 2950 ¥æ´«¾¹¥i°t¸m¬°Cisco ¥æ´«¾¹ÂO¶°¤ºªº±±ºÝ¥æ´«¾¹(command switch)
©Î³Q±±ºÝ¥æ´«¾¹(member switch)¡C±±ºÝ¥æ´«¾¹¥i§@¬°³æ¤@ºô¸ô¦ì§}ªº
ºÞ²zÂI¡A¨Ãµo§G©Ò¦³ºô¸ôºÞ²zû¤U¹FªººÞ²z«ü¥Üµ¹¨ä¥¦¤¬¬Û³s±µªº³Q±±ºÝ¥æ´«¾¹¡C¡C±±ºÝ¥æ´«¾¹¥iÂO¶°°ª¹F15
³¡ÃB¥~¤¬¬Û³s±µªº³Q±±ºÝ¥æ´«¾¹¡A¦Ó¤£ºÞ¤¬¬Û³s½u¨Ï¥Îªº¹êÅé¡CCMS
¤]¥iÅýºô¸ôºÞ²zû«ü©w¤@³¡«Ý©R¥Î©Î³Æ´©¥Îªº±±ºÝ¥æ´«¾¹¡A¦b¥Dn±±ºÝ¥æ´«¾¹¬G»Ù®É¡A±µºÞµo§G«ü¥Oªº¤u§@¡C
- ³z¹L¾ã¦X¦¡ªºCisco IOS ¥\¯à¡A´£¤É¦w¥þ©Ê»PºÞ²z©Ê¡ACisco Catalyst 2950
¨t¦C¥æ´«¾¹¨ã¦³´X¶µ¨ô¶Vªº¯S©Ê¡A¥i¼W¥[ºô¸ôªº®Ä¯à¡B¥iºÞ²z©Ê»P¦w¥þ©Ê¡Cºô¸ôºÞ²zû¥i¦b¨C³¡¥æ´«¾¹°t¸m°ª¹F64
²ÕµêÀÀ°Ï°ìºô¸ô(VLAN)¡A°õ¦æ¸û°ªµ¥¯Åªº¸ê®Æ¦w¥þ©Ê¡A¨Ã´£¤ÉLAN®Ä¯à¡C¦¹¥i½T«O¸ê®Æ«Ê¥]¥u·|³Q¶Ç°e¨ì¯S©wVLAN
¤ºªº¯¸¥x¡A¦bºô¸ô¦h²Õ°ð¤§¶¡«Ø¥ß¤@¹DµêÀÀªº¨¾¤õÀð¡A¨Ã´î¤Ö¼s¼½¶Ç¿é¡C§Q¥Î¼Ð·Ç¦¡ªº802.1Q VLAN ·F½u
(trunking)¬[ºc¡A§Y¥i±q¥ô¦ó°ð«Ø¥ßVLAN ·F½u¡C¨CÓVLAN§¡¦³Ó§OªºSpanning Tree
(PVST+)ªº§Þ³N¯àÅý¨Ï¥ÎªÌ°õ¦æ³Æ´©ªº¤WÃì¡A¦P®ÉÁÙ¯à¤À°t¸ó¦h«³s½uªº¬y¶qt²ü¡C¦Ó°õ¦æ¼Ð·Çªº¤À´²¾ð¨ó©w(Spanning Tree
Protocol, STP)¥\¯à®É«oµLªk¹F¦¨¦¹¶µ¥\¯à¡CCisco Uplink Fast§Þ³N¯à¥ß§Y¶Ç¿é¦Ü²Ä¤G¤WÃì¡A¤ñ¶Ç²Îªº30 ¦Ü60
¬íºô¸ô¦^´_®É¶¡§ó¨Î¡C³o¤]¬O°õ¦æSTP¥t¤@¶µ´£¤É¥\¯à¡C
- ¦³¤FCatalyst 2950
¥æ´«¾¹¡Aºô¸ôºÞ²zû´N¯à°õ¦æ°ª¶¥ªº³s±µ°ð»P±±¨î¥x¤§¦w¥þ©Ê¡C¥HMAC¦ì§}¬°°ò¦(address-based)ªº°ð¦w¥þ©Ê¡A¯à¹w¨¾¥¼±ÂÅvªº¯¸¥x¦s¨ú¥æ´«¾¹¡A¨Ã¥i«Ø¥ßÀR¤î»P°ÊºAªº¦ì§}¨î¡A¨ÏºÞ²zû§ó¯à±±¨îºô¸ôªº¦s¨ú¡C¥æ´«¾¹±±¨î¥x¤Wªº¦h¼h(Multilevel)¦s¨ú¦w¥þ©Ê¡A¯à¹w¨¾¥¼±ÂÅvªº¨Ï¥ÎªÌ¦s¨ú©ÎÅܧó¥æ´«¾¹ªº²ÕºA³]©w¡C²×ºÝ¦s¨ú±±¨î¾¹¦s¨ú±±¨î¨t²Î(TACACS+)ªºÅçÃÒ¡A¯à¶°¤¤¨ó½Õ¤j¶qºô¸ô¸Ë¸m
ªº¦s¨ú±±¨î¡C
¥Dn¥\¯à¤ÎÀuÂI
²£«~¯S©Ê
- ¨ô¶Vªº®Ä¯à
- ´£¨Ñ©Ò¦³°ð½u³t¡BµLªý¶ëªº®Ä¯à¡A¥]¬A¶W°ª³tGigabit °ð
- 8.8-Gbps ¥æ´«µ²ºc»P¨C¬í³Ì¦h¶Ç¿é6.6Mpps «Ê¥]ªº³t«×¡A½T«O³Ì¤jªº¿é¥X¶q- §Y¨Ï³ÌµÛ«®Ä¯àªºÀ³¥Îµ{¦¡¥ç¦P¡C
- 12 Ó©Î24 Ó10BaseT/100BaseTx ¦Û°Ê·P´ú°ð¡A¦U¥i¶Ç»¼¦h¹F200 Mbps
ªºÀW¼eµ¹Ó§O¥Î¤á¡B¦øªA¾¹©Î¤u§@¸s²Õ¡A¥H¤ä´©³ÌµÛ«ÀW¼eªºÀ³¥Îµ{¦¡¡C
- Catalyst 2950T-24
¾Ö¦³¨âÓ¤º«Øªº¶W°ª³t¤A¤Óºô¸ô°ð(1000BaseT)¡A¥i¦b¶W°ª³t¤A¤Óºô¸ô¥D·F¡B¶W°ª³t¤A¤Óºô¸ô¦øªA¾¹©Î¥æ´«¾¹¤§¶¡¡A¶Ç»¼¦h¹F4
Gbpsªº»E¶°ÀW¼e(µ½¥Î²{¦³ªºCat. 5 »ÉÆl½u¬[ºc)¡A³Ì»·¶ZÂ÷¥i¹F¤@¦Ê¤½¤Ø¡C
- Catalyst 2950C-24 ¥æ´«¾¹¦³¨âÓ¦h«¼Ò¦¡
(100BaseFX) ¥úÅÖ¤WÃì(fiber uplinks)¡A¥i¶Ç»¼¦h¹F200 Mbps ªºÀW¼e¡A³Ì»·¶ZÂ÷¥i¹F¤G¤½¨½¡C
- 8 MB ¦@¨É°O¾ÐÅé¬[ºc¯à½T«O¾Ö¦³³Ì°ªªº¿é¥X¶q¡A¦]¬°¥¦ªº³]p¯à±Æ°£head-of-line
ªý¶ë¡B¨Ï«Ê¥]·l¥¢´î¨ì³Ì§C¡A¦b¸s¼½»P¼s¼½¬y¶q¼sªxªºÀô¹Ò¤¤¡A¯à¶Ç»¼¸û¨Îªº¾ãÅé®Ä¯à¡C
- ¤º«Ø16 MBªºDRAM¤Î8 MB§Ö°{°O¾ÐÅé(Flash)¡A¯à¦b¥¼¨Ó¶i¦æ¤É¯Å¨Ï«È¤á§ë¸ê±o¨ì³Ì¤jªº«O»Ù¡C
- ³z¹LFast EtherChannel »PGigabit EtherChannel
ÀW¼e»E¶°ªº§Þ³N¡A¯à´£¤É®e¿ù²v¡A¨Ã´£¨Ñ¥æ´«¾¹¶¡¦h¹F4 Gbps ªº»E¶°ÀW¼eµ¹¸ô¥Ñ¾¹»PÓ§O¦øªA¾¹¡C
- ¨CÓ°ð¤W¬Ò¦³¥H802.1Q ¼Ð·Ç¬°°ò¦ªºVLANtrunking¡F¨C³¡¥æ´«¾÷¤W¦@¥i³]©w64 ²ÕVLAN
¡A¨Ã¥i¦P®É°õ¦æ64 ²ÕSpanning Tree (PVST+)¡C
- Âǵ۵wÅé¤ä´©IGMP snooping ¥i´£¨ÑÀu¶Vªº¦hÂI¸s¼½ºÞ²z¥\¯à¡C
- QoS
- ®Ú¾Úºô¸ôºÞ²z¤H¤À¬£µ¹¨CÓ°ðªº802.1p CoS ȩιw³]CoS Ȥ§°T®Øªº«·s¤ÀÃþ¤ä´©
- µwÅé¤W¨CÓ¥X¤f¦³¥|Ó¦î¦C
- WRR ¦î¦Cºtºâªk¡A½T«OÀu¥ýÅv¸û§Cªº¦î¦C¤]¥i¥H±o¨ì¶Ç¿éªº«~½è
- ÄY®æªºÀu¥ýÅv±Æ§Ç²ÕºA¡A½T«O¹ï®É¶¡±Ó·P«×¸û°ªªºÀ³¥Îµ{¦¡¡A¦Ó¯à¥Ã»·¥H³Ì¨³³tªº¸ô®|¬ï³z¥æ´«¾¹µ²ºc¡C
- ®e©ö¨Ï¥Î¥B®e©ö°t¸m
- Cisco CMS ¯àÅýºô¸ôºÞ²zû³z¹L³æ¤@ªºIP ¦ì§}¡A¨Ï¥Î¥ô¦ó¼Ð·Çªººô¶ÂsÄý¾¹¨ÓºÞ²z¦h¹F16
³¡¤¬¬Û³s±µªºCatalyst 2950, 3550-12T, 3500 XL, 2900 XL, ©M1900
¥æ´«¾¹¡A¦Ó¤£ºÞ¥æ´«¾¹ªº¦ì¸m- ¤]´N¬O»¡¡A¥æ´«¾¹¨Ã¤£¤@©wn¹êÅé°t¸m¦b¬Û¦Pªº°t½u½c¤º¡C
- §¹¾ãªº¬Û®e¯à¤O¡A½T«O¨C¤@³¡Catalyst 3500 XL,Catalyst 2900 XL©ÎCatalyst 1900
¥æ´«¾¹¡A³£¯à¥H¨Ï¥ÎCisco CMS ªºCatalyst 2950 ¥[¥HºÞ²z¡C
- ÂO¶°³nÅé¤É¯Å¯S¦â¡A¯àÅý¨Ï¥ÎªÌ¦Û°Ê¤É¯ÅCatalyst 3550-12T, Catalyst 2950, Catalyst
3500 XL »PCatalyst 2900 XL ¥æ´«¾¹¸s²Õ©Ò¨Ï¥Îªº¨t²Î³nÅé¡C
- ¦Û°Ê°»´ú¨CӰ𪺳t«×¤Î³s±µ³]©w¡A¨Ã¦Û°Ê³]©w°ðªº²ÕºA¬°10, 100 ©Î1000 Mbps ¡A¨Ï²V¦X10,
100,»P1000BaseT Àô¹Ò¤¤ªº¥æ´«¾¹°t¸m§ó®e©ö¡C
- ¦Û°Ê¨ó°Ó©Ò¦³°ð¡A¥H¦Û°Ê¿ï¾Ü¥bÂù¤u©Î¥þÂù¤u¶Ç¿é¼Ò¦¡¡A¨ÏÀW¼e¯à³Ì¦³®Ä¦a§Q¥Î¡C
- §Ö¨ú°O¾ÐÅ餺Àx¦sªº¹w³]²ÕºA³]©w¡A½T©w¥æ´«¾¹¯à°÷§Ö³t³s±µ©óºô¸ô¡A¨Ã¯à¦b¨Ï¥ÎªÌ¤zÂZµ{«×³Ì§Cªº±¡ªp¤U³q¹L¬y¶q¡C
- ¾ã¦X¦¡ªºCisco IOS ¥æ´«¾¹¸Ñ¨M¤è®×
- ³z¹LFast EtherChannel »PGigabit EtherChannel
§Þ³NÀW¼e»E¶°¡A¯à´£¤É®e¿ù²v¡A¨Ã¬°¥æ´«¾¹¡B¸ô¥Ñ¾¹»PÓ§O¦øªA¾¹¤§¶¡¡A´£¨Ñ°ª¹F4 Gbps ªºÀW¼e¡C
- ¨CӰ𪺼s¼½·¼É±±¨î(broadcast storm
control)¡A¯à¨¾¤î¿ù»~ªº²×ºÝ¯¸¥x¥H¼s¼½·¼É¡A´î·l¾ãÅé¨t²Îªº®Ä¯à¡C
- «ü¥O¦C¾Þ§@¤¶±(Command line interface,
CLI)¤ä´©¥i´£¨Ñ¨Ï¥ÎªÌ¤¶±»P«ü¥O¶°¡A¾A¥Î©ó©Ò¦³Catalyst¥æ´«¾¹»PCisco ¸ô¥Ñ¾¹¡C
- Cisco Discovery Protocol (CDP)
¯àÅýCiscoWorksºô¸ôºÞ²z¯¸¥x¦Û°Êµo²{ºô¸ô©Ý¾ë¤ºªº¥æ´«¾¹¡C
- Àu¶Vªº¥iºÞ²z¯à¤O
- Cisco CMS ¯àÅýºô¸ôºÞ²zû³z¹L³æ¤@ªºIP ¦ì§}¡A¨Ï¥Î¥ô¦ó¼Ð·Çªººô¶ÂsÄý¾¹¨ÓºÞ²z¦h¹F16
³¡¤¬¬Û³s±µªºCatalyst 2950, 3550-12T, 3500 XL, 2900 XL ©M1900
¥æ´«¾¹¡A¦Ó¤£ºÞ¥æ´«¾¹ªº¦ì¸m¤]´N¬O»¡¡A¥æ´«¾¹¨Ã¤£¤@©wn¹êÅé°t¸m¦b¬Û¦P°t½u½c¤º¡C
- ¥æ´«¾¹ÂO¶°³nÅé¤É¯Å¡A¯àÅýºô¸ôºÞ²zû³z¹L¨Ï¥Î®e©öªºCisco CMS ¤¶±©Î³æ¤@CLI
«ü¥O¡A¨Ï³Ì¦h16³¡¤¬¬Û³s±µªº¥æ´«¾¹¨t²Î³nÅé¤É¯Å¡C
- ²©öºô¸ôºÞ²z¨ó©w(Simple Network Management Protocol, SNMP)»PTelnet
¤¶±¤ä´©¡A¥i´£¤É¼sªxªºÀW¤º(in-band)ºÞ²z¡A¥BCLI-based
ªººÞ²z±±¨î¥x¥i´£¤É¸Ô²ÓªºÀW¥~(out-of-band)ºÞ²z¡C
- ³z¹L¨C¤@°ð»P¨C¤@¥æ´«¾¹¤WªºCiscoWorks Windowsºô¸ôºÞ²z³nÅé¡A¥i´£¨Ñ¤@¦@¥ÎªººÞ²z¤¶±¡A¥HºÞ²zCisco
¸ô¥Ñ¾¹¡B¥æ´«¾¹»P¶°½u¾¹¡C
- ¤º«Øªº»·µ{ºÊ±±(Remote Monitoring, RMON)³nÅé¥N²zµ{¦¡¡A¥i¤ä´©¥|ÓRMON
¸s²Õ(¾ú¥v¡B²Îp¡Bĵ¥Ü»P¨Æ¥ó)¥H«P¶i¬y¶qºÞ²z¡BºÊ±±»P¤ÀªR®Ä¯à¡C
- ¥æ´«¾¹°ð¤ÀªR(Switch Port Analyzing, SPAN)°ð¡A¥iºÊ´ú³æ¤@ºô¸ô¤ÀªR¾¹©ÎRMON probe
ªº³æ¤@°ðªº¬y¶q¡C
- ¦Û°Ê²ÕºA³]©w¥\¯à¡A¯à¸g¥Ñ¶}¾÷¦øªA¾¹(boot server)¦Û°Ê¤Æ²ÕºAºô¸ô¤ºªº¦h¥x¥æ´«¾¹¡A²¤Æºô¸ô¤º°t¸m¥æ´«¾¹ªº§@·~¡C
- ºô°ì¦WºÙªA°È(Domain Name Services, DNS)¥i´£¨ÑIP ¦ì§}¸ÑªR»P¨Ï¥ÎªÌ©w¸qªº¸Ë¸m¦WºÙ¡C
- Trivial File Transfer Protocol(TFTP) ¥iÂǵ۱q¤¤¥¡¦ì¸m¤U¸ü¤É¯ÅªººÞ²z³nÅé¦Ó°§C¦¨¥»¡C
- Network Time
Protocol(NTP)¡A¯à´£¨Ñ¥¿½T¥B¤@Pªº®É¶¡ÂW°O(timestamp)µ¹©Ò¦³¥ø·~¤º³¡ºô¸ôªº¥æ´«¾¹¡C
- Spanning Tree Root Guard(STRG)¡A¥i¹w¨¾¤£¦bºô¸ôºÞ²zû±±¨î¤UªºÃä½t¸Ë¸mÅܦ¨STP
®Ú¸`ÂI¡]root nodes¡^¡C
- ¨C°ð³£¦³¦h¥\¯àLED Åã¥Ü¡A¥i´£¨Ñ°ðªºª¬ºA¡B¥b¤u/ ¥þÂù¤u¡B¥H¤Î10BaseT/100BaseTX/1000BaseT
µ¥«ü¥Ü¡A¨Ã¦³§C¶¥¥æ´«¼h¦¸¡]switchlevel¡^ª¬ºALED Åã¥Ü¡A´£¨Ñ¨t²Î¡BRPS
»PÀW¼e§Q¥Îµ¥ª¬ºA¡A¥H§Î¦¨¤@¼sªx¥B«K§QªºµøıºÞ²z¨t²Î¡C
- ¦w¥þ©Ê»P³Æ´©¥\¯à
- IEEE 802.1x ¤ä´©(¦³p¹º¦a¤ä´©¥¼¨Óªº³nÅé)¡C
- Cisco Uplink Fast
§Þ³N¡A½T«O¯à§Ö³t°õ¦æ¥¢±Ñ±µºÞ´_쪺¥\¯à(³q±`¦b¤T¬í¤º´N¯à°õ¦æ)¡A¥H´£¤É¾ãÅéºô¸ôªºÃ©w©Ê»P¥i¾a©Ê¡C
- Private VLAN Edge
¯à´£¨Ñ¤@¥æ´«¾¹¤W¡A¦U°ð¤§¶¡ªº¦w¥þ©Ê»P¿W¥ß©Ê¡A½T«O»yµ¬y¶q¯à°÷ª½±µ±q¿é¤JÂI¡A³z¹LµêÀÀ¸ô®|¶Ç°e¨ì»E¶°¸Ë¸m¡A¦Ó¤£·|³Q°e¨ì¤£¦Pªº°ð¡C
- MAC-based Filter ½T«O³s±µ°ð¦w¥þ©Ê¡A¥i¹w¨¾¥¼±ÂÅvªº¯¸¥x¦s¨ú¥æ´«¾¹¡C
- ¨Ï¥ÎªÌ¥i¿ï§}¦¡ªº¾Ç²ß¼Ò¦¡¡A¥i²¤Æ²ÕºAªº³]©w¨Ã´£¤É¦w¥þ©Ê¡C
¡¹ IEEE 802.1D STP ¥i´£¨Ñ³Æ´©¥D·F³s½u»PµL°j¸ôºô¸ôªº¤ä´©¡A²¤Æºô¸ôªº²ÕºA³]©w¨Ã§ïµ½®e¿ù²v¡C
- ¤ä´©Cisco Redundant Power System 300 (RPS
300)¡A³Ì¦h¥i´£¨Ñ¤»¶µºô¸ô¤¸¥ó³Æ´©ªº¤º³¡¹q¤O¡A¥H§ïµ½®e¿ù²v»Pºô¸ô³s½u²v(uptime)¡C
- ±±¨î¥x¦s¨úªº¦h¼h¦w¥þ©Ê¡A¥i¹w¨¾¥¼±ÂÅvªº¨Ï¥ÎªÌÅܧó¥æ´«¾¹²ÕºAªº³]©w¡C
- ¤ä´©TACACS+ ÅçÃÒ¡A¯à¶°¤¤±±¨î¥æ´«¾¹¡A¨Ã¨î¥¼±ÂÅvªº¨Ï¥ÎªÌÅܧó¥æ´«¾¹²ÕºAªº³]©w¡C
|
³W®æ
|
- ®Ä¯à
- 8.8-Gbps IªO¥æ´«¼eÀW(switching fabric)
- ¥H64- ¦ì¤¸«Ê¥]ªº¶Ç°e³t²v¦Ó¨¥¡G
¡X Catalyst 2950-12¡G1.8 Mpps ½u³t¶Ç°e³t²v
¡X Catalyst 2950-24¡G3.6 Mpps ½u³t¶Ç°e³t²v
¡X Catalyst 2950T-24¡G6.6 Mpps ½u³t¶Ç°e³t²v
¡X Catalyst 2950C-24¡G3.9 Mpps ½u³t¶Ç°e³t²v
- ³Ì¤j¶Ç°eÀW¼e4.4-Gbps
- ©Ò¦³°ð¦@¨É8 MB «Ê¥]½w½Ä¾¹°O¾ÐÅé¬[ºc
- 16 MB DRAM »P8 MB §Ö°{°O¾ÐÅé
- ³Ì¤j¶Ç°eÀW¼e4.4-Gbps
- 8,000 ²ÕMAC ¦ì§}
- ºÞ²z
- SNMP Management Information Base (MIB) II,SNMP MIB
extensions, Bridging MIB (RFC 1493)
- ¼Ð·Ç
- IEEE 802.1x ¤ä´©(¦³p¹º¦a¤ä´©¥¼¨Óªº³nÅé)
- IEEE 802.3x Full duplex 10BaseT, 100BaseTX, »P
1000BaseT °ð
- IEEE 802.1D Spanning Tree Protocol
- IEEE 802.1p CoS
- IEEE 802.1Q VLAN
- IEEE 802.3ab 1000BaseT ³W®æ
- IEEE 802.3u 100BaseTX ³W®æ
- IEEE 802.3 10BaseT ³W®æ
- Y2K
- Y2K compliant±µÀY»P±µ½u
- 10BaseT °ð¡GRJ-45 ±µÀY¡A¨â²ÕCat. 3, 4, ©Î5 ¥¼¥]ÂÐÂùµ±½u(UTP)Æl½u
- 100BaseTX °ð¡GRJ-45 ±µÀY¡A¨â²ÕCat. 5 UTPÆl½u
- 1000BaseT °ð¡GRJ-45 ±µÀY¡A¨â²ÕCat. 5 UTPÆl½u
- 100BaseFX °ð¡GMT-RJ ±µÀY¡A 10/125 ©Î62.5/125·L¦Ì¦h¼Ò¥úÅÖ(micron
multi-mode fiber-optic)
- ºÞ²z±±¨î¥x°ð¡G8-pin RJ-45 ±µÀY¡ARJ-45-to-RJ-45rollover Æl½u»PRJ-45-to-DB9
°t±µ¾¹¡A¥Î©ó³s±µPC¡C²×ºÝ³s½u®É¡A¨Ï¥ÎRJ-45-to-DB25 ³±©ÊDTE°t±µ¾¹(¥iÓ§O¦VCisco qÁÊ¡C¹s¥ó½s¸¹¡G
ACSDSBUSYN=)
- MT-RJ ©µªøÆl½u(Patch Cables)(Æl½uÃþ«¬, Cisco ¹s¥ó½s¸¹)
- 1-¦Ì, MT-RJ-to-SC ¦h¼ÒÆl½u, CAB-MTRJ-SC-MM-1M
- 3-¦Ì, MT-RJ-to-SC ¦h¼ÒÆl½u, CAB-MTRJ-SC-MM-3M
- 5-¦Ì, MT-RJ-to-SC ¦h¼ÒÆl½u, CAB-MTRJ-SC-MM-5M
- 1-¦Ì, MT-RJ-to-ST ¦h¼ÒÆl½u, CAB-MTRJ-ST-MM-1M
- 3-¦Ì, MT-RJ-to-ST ¦h¼ÒÆl½u, CAB-MTRJ-ST-MM-3M
- 5-¦Ì, MT-RJ-to-ST ¦h¼ÒÆl½u, CAB-MTRJ-ST-MM-5M
- ¹q·½½u±µÀY
- ±z¥i¨Ï¥Î¤º³¡¹q·½¨ÑÀ³¾¹©ÎCisco RPS 300 ´£¨Ñ¥æ´«¾¹©Ò»Ý¹q·½¡C¹q·½½u±µÀY¦ì©ó¥æ´«¾¹I±¡C
- ¤º³¡¹q·½¨ÑÀ³¾¹±µÀY
- ¤º³¡¹q·½¨ÑÀ³¾¹¬O¦Û°Ê½d³ò(autoranging)²Õ¥ó
- ¤ä´©100 ¦Ü240 VAC ªº¿é¤J¹qÀ£
- ¨Ï¥Î°t³ÆªºAC ¹q·½½u³s±µAC ±µÀY»PAC ´¡®y
- Cisco RPS ±µÀY
- ³s±µ©Ò¿ï°t¡B¿é¤J¥æ¬y¹qªºCisco RPS 300 ¡A¨Ã¿é¥Xª½¬y¹qµ¹¥æ´«¾¹
- 300 ¥Ë³Æ´©¹q¤O¨t²Î¡A¥i¥H¤ä´©¤»³¡¥~±µªººô¸ô¸Ë¸m¡A¤@¦¸¯à´£¨Ñ¹q¤Oµ¹¤@³¡¹q¤O¬G»Ùªº¸Ë¸m
- ¦Û°Ê·P´ú¤º³¡¹q·½¨ÑÀ³¾¹¬G»Ùªº³s±µ¸Ë¸m¡A¨Ã´£¨Ñ¹q¤Oµ¹¬G»Ùªº¸Ë¸m¡A¹w¨¾ºô¸ô¬y¶qªº·l¥¢
- ·í¥æ´«¾¹ªº¤º³¡¨Ñ¹q³Q×´_©Î§ó·s¡ARPS 300·|¦Û°Ê°±¤î¨Ñ¹qµ¹¸Ó¸Ë¸m
- ¶È¥Î¨Ó³s±µCisco RPS 300 («¬¸¹PWR300-ACRPS-N1) ¦ÜRPS ´¡®y
- «ü¥Ü¾¹
- ¨CÓ°ðªºLED ª¬ºA«ü¥Ü¾¹¡G«ü¥Ü³s½uªº§¹¾ã¡B¬G
»Ù¡B¬¡°Ê¡B³t«×»P¥þÂù¤u
- ¨t²Îª¬ºALED «ü¥Ü¾¹¡G«ü¥Ü¨t²Î¡BRPS »PÀW¼e§Q¥Î²v
- ¤Ø¤o»P«¶q(°ªx ¼ex ²`)
- ¤Ø¤o¡G1.72 x 17.5 x 9.52 ¦T(4.36 x 44.45 x 24.18 ¤½¤À)
- °ª«×¡G¤@¾÷½c³æ¦ì(RU) (1.72 ¦T/4.36 ¤½¤À)
- «¶q¡G6.5 ½S(3.0 ¤½¤ç)
- ¥§¡¬G»Ù¶¡¹j®É¶¡(MTBF) ¹w´ú®É¼Æ
¡@
¹s¥ó½s¸¹MTBF ¹w´ú(¤p®É) |
MTBF¹w´ú(¤p®É) |
WS-C2950T-24 297,144 |
297,144 |
WS-C2950-24 268,292 |
268,292 |
WS-C2950C-24 268,292 |
268,292 |
WS-C2950-12 318,440 |
318,440 |
¡@ |
¨t²Î»Ý¨D
|
- Àô¹Òªº±ø¥ó
- §@·~·Å«×¡G23¢K∼ 113 ¢K (-5¢J∼ 45 ¢J)
- Àx¦s·Å«×¡G-13¢K∼ 158¢K (-25¢J∼ 70¢J)
- §@·~¬Û¹ïÀã«×¡G10 ~ 95% («D§N¾®)
- §@·~°ª«×¡G§C©ó10,000 §`(3,000 ¤½¤Ø)
- Àx¦s°ª«×¡G§C©ó15,000 §`(4,500 ¤½¤Ø)
- ¹q¤O»Ý¨D
- ¯Ó¹q¶q¡G30W(³Ì¤j)¡A¨C¤p®É102 BTUs
- ¥æ¬y¿é¤J¹qÀ£/ÀW²v¡G100∼127 ©Î200∼240 VAC(auto-ranging), 50 ∼ 60 Hz
- ª½¬y¿é¤J¹qÀ£¡G+12V @ 4.5A
|
³sµ²
|
|
|
¡D¥»¤å¥óªº¸ê°TY¦³×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ùY¦³»~¡A¥Hì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨äì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C
º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á!
ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶WÈÀu´fªºCisco - WS-C2950-24ºô¸ô°ò¦«Ø³]¥æ´«¾¹Switch - ºô¸ô³]³Æ/ÀW¼eºÞ²z
,³Ì¦nªºCisco - WS-C2950-24ºô¸ô°ò¦«Ø³]¥æ´«¾¹Switch±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
|
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§ÚÌ·|¬°±z¦Vì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú̳£¥i¼u©Ê°t¦X±zªº»Ýn³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G
1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901 |
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»¶ÁʶR¸ß»ù§ÚÌ·|¥ß§Y»P±zÁpô! |
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw |
|
¥I´Ú¤è¦¡¡G¦p«È¤á¬°º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C |
¶Ç¯uq³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨qÁʵ{§Ç¡A§ÚÌ·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{q³æ¡C |
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú̦¬¨ì±zq³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C |
°e³f¤è¦¡¡G(1) ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C |
°e³f½d³ò¡G¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±zt¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C |
°â«áªA°È¡GY²£«~¥»¨·å²«©Î¹B°e¹Lµ{¾ÉP·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C |
«O©T¬Fµ¦¡G ¹ê»Ú¥Hì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C |
¤O±ô¸ê°T ServerBank Inc. ²¤¶
¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G
»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶Û¡B¥xÆWªFªÛ¡B¥xÆW^¸â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B
¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B
ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B
¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B
Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B
¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B
´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B¸ºÐ¼s¼½¡B·¼é°Û¤ù¡B®É³ø©P¥Z¡B
±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B
²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡Bì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°
¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B
ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B
¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B
¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤±]±¶¹B¡B¥xÆW´¼¼z¥d¡B
¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½^¡B¿ßÀYÆN
©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B
x¤è¡G ªÅx¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B
|
|
|
|
|
|
|
¡@ |
|