­º­¶> Àx¦s³]³Æ/³Æ¥÷¤è®×

>>ÂsÄý©Ò¦³QNAP«ÂÁp³qÀx¦s³]³Æ/³Æ¥÷¤è®×

QNAP«ÂÁp³q
TS-410U Turbo NAS

«¬¸¹¡GTS-410U


QNAP«ÂÁp³qTS-410U


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQNAP«ÂÁp³q - TS-410U - Àx¦s³]³Æ/³Æ¥÷¤è®×
³Ì¦nªºQNAP«ÂÁp³q - TS-410U Turbo NAS±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óQNAP«ÂÁp³q¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§QNAP«ÂÁp³q²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§QNAP«ÂÁp³q­ì¼t°t¥ó


¡@

¡@

¡@

¯S¦â:

¡´¥þ·sªº¨Ï¥ÎªÌ¤¶­±

Âù Gigabit ºô¸ôºÝ¤f¤ä´©¦h¶µ³]©w
ºô¸ô®e¿ù (Failover)
ºô¸ô®e¿ù´£¨Ñ¤F¤£¶¡Â_ªººô¸ôªA°È¡A·í¨â­Óºô¸ôºÝ¤f³£³s¤Wºô¸ô®É¡A¤@±øºô¸ô½uµo¥Í¬G»Ù°ÝÃD®É¡A¥t¤@±ø¥i¥HÄ~Äò´£¨Ñºô¸ôªA°È¡C

¡´ºô¸ô­t¸ü¥­¿Å (Load-Balancing)
TS-410U ¤ä´©Bandwidth aggregation¡A¼W¥[Àɮתº¶Ç¿é³t²v(»Ý­n·f°t¤ä´©802.3ad³]©wªº¤A¤Ó¥æ´«¾¹)¡C

¡´Âùºô¸ô IP ³]©w
TS-410U ¥i¥H³]©w¨â­Ó¤£¦Pªº IP¡A¨Ã¦P®ÉªA°È¦b¨â­Ó¤£¦P¤lºô¬qªº¤u§@¸s²Õ¡C

±M·~¯Åªº°ª®Ä¯à¡B°ªÃ­©w©Ê¤Î¨ã¨aÃø¨¾½d¾÷¨îªººô¸ôÀx¦s¦øªA¾¹
¥ý¶iªºRAIDºÏºÐ°}¦CºÞ²z¤Î¤ä´©¼ö©â´«³]­p
¬°¤F½T«O¸ê®Æªº¦w¥þ©Ê¡ATS-410U ´£¨Ñ¥ý¶iªºRAIDºÏºÐ°}¦CºÞ²z¥\¯à¡A¥u­n³z¹L²³æ­¶­±³]©w§Y¥i»´ÃP§¹¦¨³]©w¡A¨ä¤¤¥]¬ARAID 0¡B1¡B5¡B6¡B5 + hot spare¡BSingle¤ÎJBOD¡C¤ä´©¼ö©â´«ªº³]­p¡A´£¨Ñ±z¤£¶¡Â_»P®e©öºûÅ@ªºªA°È¡C»â¥ý·~¬Éªº RAID ºÞ²z³]­p¡A¬Û¤ñ©ó¨ä¥¦«~µPªºNAS¡A¥i¥H®e³\§ó¦h¤@ÁûªºµwºÐ·l·´¡A³o¼Ëªº³]­p¥i¥H±aµ¹¨Ï¥ÎªÌ¤@­Ó§ó¦w¥þªº¸ê®ÆÀx¦sÀô¹Ò¡C

¡´½u¤WRAID®e¶qÂX¥R
RAID®e¶qÂX¥RÅý¨Ï¥ÎªÌ¥i¦b«O¯d©Ò¦³¸ê®Æ¡B¤£°±¾÷ªº±¡ªp¤U¡A¤@¨B¤@¨B¦a¶¶§Qªº¶i¦æRAID®e¶qÂX¥R¡C

¡´½u¤WRAID²ÕºA¾E²¾
½u¤WRAID²ÕºA¾E²¾Åý¨Ï¥ÎªÌ¥i³z¹L²©ö¨BÆJ¡A¦b¤£°±¾÷¥B«O¯d¸ê®Æªºª¬ºA¤U¶i¦æRAIDµ¥¯Å¾E²¾¡C

¡´³z¹LµêÀÀºÏºÐ ¡A¼u©ÊÂX¥R±zªº NAS ®e¶q
¸g¥Ñ¿W¯Sªº¡u¥~±µµêÀÀºÏºÐ¡v¡AºÞ²zªÌ¯à§ó¼u©Ê¦aÂX¥R NAS ªº®e¶q¡C³z¹L¤º«ØªºiSCSI initiator¥\¯à¨Ó³s±µºô¸ô¤W¨ä¥L iSCSI target¡A¥i±N¨äÅܦ¨¨t²Î¤WªºµêÀÀºÏºÐ¡CQNAP NAS ¥i°µ¬°°ïÅ|¥D¸Ë¸m (stack master) ¡A³s±µ¦h¹F 8 ­ÓµêÀÀºÏºÐ/°ïÅ|¥Ø¼Ð (stack targets)¡C¦]¦¹¡A©Ò¦³ªº NAS ¨Ï¥ÎªÌ¶È»Ý³s½u¦Ü¦¹³æ¤@¤J¤f¡A§Y¥i¨Ï¥Î¦ì©ó¨ä¥¦ºô¸ôÀx¦s¸Ë¸m¤WªºªÅ¶¡¡C

¡´«Ø¸m¦¨¥»¤Î°ª¼u©Êªº iSCSI ¸Ñ¨M¤è®×
«ÂÁp³qªºTS-410U¯à°÷¦P®É¤ä´©NAS¤ÎiSCSI ¸Ë¸m¹B§@¡A´£¨Ñ¤¤¤p¥ø·~¤@­Ó­Ý¨ã§C¦¨¥»°ª¼u©Ê¤Î¦³®Ä²vªºIP-SAN¸Ñ¨M¤è®×¡C¦øªA¾¹ºÞ²z­û¯à°÷¨Ï¥Î¤º«ØªºiSCSI ¸Ë¸mªA°È«Ø¥ß³Ì¦h¤K²Õ¸Ë¸m¡C¤£¦PªºiSCSIÅÞ¿è³æ¤¸¼Æ(LUNs ¡GLogical Unit Number) ¯à°÷°µ¬°²{¦³Àx¦sªÅ¶¡ªºÂX¥R©Î¬O²{¦sÀ³¥Î¦øªA¾¹ (¦p¡G¸ê®Æ®w¦øªA¾¹¡B¹q¤l¶l¥ó¦øªA¾¹)ªº³Æ¥÷¦ì¸m¡C

¡´S.M.A.R.T.¤Î¶i¶¥µwºÐª¬ºA±½´y(HHS)
Turbo NAS¤ä´©µwºÐS.M.A.R.T. (Self-Monitoring Analysis and Reporting Technology)¡A¯à°÷ºÊµøµwºÐª¬ºA¡BÀˬd¼ç¦b°ÝÃD¡A¨Ã³z¹LEmail³]©wµo¥Xĵ§i°T®§¡A´£¿ô¨Ï¥ÎªÌ¹w¥ý°µ¦n«OÅ@µwºÐ¸ê®Æªº±¹¬I¡C¦¹¥~¡ANASªº HHS (HDD Health Scanning)§Þ³N¡A¯à°÷Àˬd¨Ã±½´yµwºÐªºª¬ªp¡A¥H¹w¨¾¼ç¦b©Êªº¸ê®Æ·l¥¢¡C

§¹¾ãªº³Æ¥÷¤è®×

QNAP ¿W®a³Æ¥÷³nÅé - NetBak Replicator
QNAP´£¨Ñªº¿W®a³Æ¥÷³nÅé ¡V NetBak Replicator¡AÅý¨Ï¥ÎªÌ»´ÃP¦a³Æ¥÷Windows¹q¸£¤ºªº¸ê®Æ¦ÜTurbo NAS¡A³nÅé¤ä´©§Y®É³Æ¥÷¡B¸ê®Æ¦P¨B¤Î±Æµ{³Æ¥÷µ¥¥\¯à¡C

¡´¬Û®e²Ä¤T¤è³Æ¥÷³nÅé
QNAP NAS¬Û®e©ó¥«­±¤W¥D¬yªº³Æ¥÷³nÅé¡A¨Ò¦pAcronis True Image, CA BrightStor ARCserve Backup, EMC Retrospect, Symantec Backup Exec¤Î LaCie Silverkeeperµ¥¡C

¡´Rsync»·ºÝ³Æ¥÷
¦bTurbo NAS¸Ì­±ªº¸ê®Æ¥i¥H»·ºÝ³Æ¥÷¨ìQNAPªºNAS¨t¦C²£«~¸Ì­±¡A©Î¬OÂÇ¥ÑRsync³Æ¥÷¸ê®Æ¨ì¤ä´©Rsyncªº¦øªA¾¹¡C

¡´USB³æÁä¦Û°Ê³Æ¥÷
Turbo NASªº§Ö³t«þ¨©Áä¥i¥H³]©w¬°±Ò°Ê¥ß§Y½Æ»s¥~±µUSB¸Ë¸mªº¸ê®Æ¨ìNAS¡A©Î¬O½Æ»sNASªº¯S©w¸ê®Æ§¨¨ì¥~±µUSB¸Ë¸m(³æÁä¦Û°Ê³Æ¥÷¥\¯à¥u¦³¨Ï¥ÎNAS«e¤èªºUSB °ð¤~¥i¥H±Ò°Ê)¡C

¥ø·~°ª®Ä¯àªººÞ²z

¤ä´©Windows, Mac, Linux ¤ÎUnix ¸ó¥­¥xªºÀɮפÀ¨É
Turbo NAS±Mªù³]­p¸ó¥­¥xªº¤ä´©¡A´£¨Ñ¤£¦P§@·~Àô¹Òªº¨Ï¥ÎªÌ¯à°÷»´ÃP¦a¤À¨ÉÀɮ׸ê®Æ¡C

¡´¤ä´©Windows ADªA°È»{ÃÒ
³z¹LWindows AD ªA°Èªº»{ÃҤ䴩¡AÅý¦øªA¾¹ºÞ²zªÌ¥i¥H»´ÃP¦a±qADºô°ì¶×¤J¨Ï¥ÎªÌ±b¤á¸ê®Æ¨ìTurbo NAS¡C¤£¦ý¤j¤j¦a¸`¬Ù¤FºÞ²z­û½Æ»s±b¸¹¤Î¸s²Õªº®É¶¡¡A¨Ï¥ÎªÌ¤]¥i¥HÄ~Äò¨Ï¥Î­ì¦³ªº±b¸¹¥H¤Î±K½X¡C

¡´ºô­¶¦¡Àɮ׺޲z¤¶­±
TS-410U ´£¨Ñºô­¶¦¡Àɮ׺޲z¤¶­±¡AÅý±z¥i¥H³z¹LÂsÄý¾¹»´ÃP¦a¤W¶Ç¤U¸ü¤ÎºÞ²z¦øªA¾¹¤ºªºÀɮסC

¡´»´ÃP¦a§@¨Ï¥ÎªÌ±b¸¹¥H¤Î¸ê®Æ§¨ºÞ²z
NAS¤ä´©§å¦¸«Ø¥ß¨Ï¥ÎªÌ¥H¤Î¹ïÀ³ªº¨Ï¥ÎªÌ±M¥ÎÀɮק¨¡A¹ï©ó¦øªA¾¹ºÞ²zªÌ¨Ó»¡¡A³o¬O¸`¬Ù®É¶¡ªº¤@¤jºÖ­µ¡C¦b¦w¥þªº¦Ò¶q¤U¡A¦øªA¾¹ºÞ²zªÌ¥i¥H¦b Windowsªººô¸ôÀô¹Ò§@ÁôÂéάO¶}±Ò¤À¨ÉÀɮק¨ªº³]©w¡C

Áo©úªº¹q·½ºÞ²z

¡´µwºÐ«Ý¾÷³]©w
¨Ï¥ÎªÌ¯à°÷³]©wµwºÐ¦b¯S©w®É¶¡µL¶i¦æ¸ê®Æ¦s¨ú®É§Y¶i¤J«Ý¾÷ªº³]©w¡C

¡´¹q·½¶}Ãö¾÷±Æµ{ºÞ²z
¦¹¥\¯àÅý¨Ï¥ÎªÌ¼u©Ê¤Æ¦a³]©wNASªº¶}Ãö¾÷®É¶¡¡A±z¥i¥H¨Ì·Ó¤u§@®É¶¡¡A³]©w¦b¥ô¦ó®É¶¡§@¦Û°Ê¶}¾÷¡BÃö¾÷©Î¬O­«·s±Ò°Êµ¥¡C

¡´UPS¤£Â_¹q¨t²Î¤ä´©
Turbo NAS¤ä´©USB¤£Â_¹q³]³Æ (usb-hid ups)¡AÅý¨Ï¥ÎªÌ¦b¥¼¹w´ÁªºÂ_¹q®É¡A¯à°÷¤Î®É°µ³B²z¡AÁקK­«­n¸ê®Æªº¿ò¥¢¡C¦P®É¤]¤ä´©·í¥«¹qµo¥Í²§±`®É¨t²Î¶i¤J«Ý¾÷¼Ò¦¡ªº®É¶¡¡C·í¥«¹q«ì´_¨Ñ¹q®É¡A¨t²Î ¥i¥H¦Û°Ê¦^´_¨ìÂ_¹q«eªºª¬ºAÄ~Äò¨Ï¥Î¡C

¡´¤ä´©AC¹q·½¦^´_®É¡A¨t²Î¹q·½³B²z¤è¦¡³]©w
TS-410U ¤ä´©¥«¹qÂ_¹q«á¹q·½«ì´_®É¨t²Îªº³B²z¤è¦¡¡C§A¥i¥H³]©w¦^´_¦Ü«e¤@¦¸ªº¶}¾÷©ÎÃö¾÷ª¬ºA¡C

¦w¥þ¸ê®ÆÀx¦s¡B¦s¨ú¤Î¤À¨É

IP¦ì§}¹LÂoºÞ²z¡GºÞ²zªÌ¥i¥H¤¹³\©Î¬O©Úµ´¯S©wªºIP¦ì§}³s±µ¨ìTurbo NAS¡C
SSL ¦w¥þ©ÊºÞ²z (HTTPS)¡GºÞ²zªÌ¥i¥H³z¹Lºô­¶¦w¥þ¦a¦s¨ú¤ÎºÞ²z¸ê®Æ¡C
³z¹LSSH (Secure Shell)¡A»·ºÝµn¤JTurbo NAS¡C
¥[±K FTP¡G³z¹LSSL/ TLS (explicit) ¥[±K¨Ó¤À¨É¤Î¶Ç¿é±zªº¸ê®Æ¡C ¨Ã¥B¤ä´©FTP³Q°Ê¼Ò¦¡¤ÎÀW¼eºÞ²z¡C
´¼¼z«¬FTPºÞ²z¡GºÞ²zªÌ¥i©Ò¦³FTP³s½u¤Î­Ó§O±b¸¹ªº³s½u¤W­­¡C
¥[±K²§¦a³Æ´©¡GTurbo NASªº¸ê®Æ¥i¥H³z¹Lºô¸ô¥[±K³Æ¥÷¨ì¨ä¥LªºQNAP NAS¨t¦C²£«~¡C
FTP¼g¤J(Write-only)Åv­­³]©w¡G¦øªA¾¹ºÞ²z­û¥i¥H°w¹ï¨Ï¥ÎªÌ°µ¶È¦³³z¹LFTP¤W¶Ç¸ê®Æ¨ìNAS¦ýµLªk½s¿è©Î¬O¤U¸ü¸ê®ÆªºÅv­­³]©w¡C
¡´ºô¸ô¦Û°ÊIP³s½u¹LÂo
¬°¨¾½dNAS¾D¨ü¨ìºô¸ô´c·N¤J«I¡A¦øªA¾¹ºÞ²z­û¯à°÷«Ø¸m¤¹³\¡B©Úµ´©Î¬O¦Û°Ê«ÊÂê³z¹LSSH/ Telnet/ HTTP(S)/ FTP/ samba/ AFPªº¦Û°Ê³s½u¹LÂo¾÷¨î¡A§ó¥[±j¤Æºô¸ôªº¦w¥þ¨¾Å@¡C

¥\¯à±j¤jªº¨t²ÎºÞ²z¤u¨ã

¡´´¼¼z«¬­·®°
­·®°ªºÂà³t¯à°÷®Ú¾Ú¥Ø«eªº¨t²Î·Å«×¦Û°Ê¦a°µ½Õ¾ã¡CºÞ²zªÌ¦P®É¯à°÷³z¹L¤â°Ê©w¸q°ªÂà¤Î§CÂ઺³]©w¡C

¡´§Y®ÉSMS/ Emailĵ°T³qª¾
¦øªA¾¹ºÞ²z­û¥i¥H³z¹LSMTP¤ÎSMSC(Short Message Service Center)ªº³]©w¡A¥ß§Y±µ¦¬§Y®ÉEmail¤Î²°T³qª¾¡AÀH®ÉÀH¦a»´ÃP´x´¤NASªº³Ì·sª¬ºA¡C

¡´SNMP (²³æºô¸ôºÞ²z¨óij)
²³æºô¸ôºÞ²z¨óij (SNMP) ¯à°÷¤ä´©ºô¸ôºÞ²z¨t²Î¡A¥Î¥HºÊ´ú³s±µ¨ìºô¸ô¤Wªº³]³Æ¡]¨Ò¦p¡GNAS¡^¡C±z¥i¥H³]©w SNMP trap ¨Ó´£¨Ñĵ¥Ü¡A³Ì¦h¥i³]©w¤T²Õ SNMP trap ¦ì§}¡C¦¹¥~¡A±z¤]¥i¥H¦b SNMP ³]©w¤¤¡A¦Û¦æ©w¸q¨t²Î¨Æ¥ó°O¿ý¤§µ¥¯Å¡C

¡´¤ä´©SSL (Secure Sockets Layer)¦w¥þ¾ÌÃÒ
ºÞ²zªÌ¯à°÷¤W¶Ç¸g»{¥iªº¦w¥þ¾ÌÃÒ¤ÎX.509PEM®æ¦¡ªºRSA¨p¤Hª÷Æ_Åý¨Ï¥ÎªÌ¯à°÷³z¹LSSLµn¤J¨Ó¦s¨úNASªº¸ê®Æ¡C

¡´¤ä´©¨t²Î¤é»x(Syslog)¦øªA¾¹³]©w
³z¹L¦¹³]©w¡A©Ò¦³NASªº¨Æ¥ó°O¿ý¤Î³s½u¬ö¿ý¯à°÷³QÀx¦s¨ì»·ºÝ¨t²Î¤é»x(Syslog)¦øªA¾¹¤¤¡C

¡´ºô¸ô¸ê·½¦^¦¬µ©
¦bNASºô¸ô¸ê®Æ§¨ùاR°£ªºÀÉ®×±N·|³Q²¾¨ì¯S©wªº¸ê·½¦^¦¬¸ê®Æ§¨¡C³z¹L³o¼Ë¥\¯à¡A±z¥i¥HÀH®É¦^¦s±z¤£¤p¤ß§R°£ªºÀɮסC

¡´¹d²ÓÃû¿òªº¨Æ¥óºÞ²z¨t²Î
Turbo NASªº©Ò¦³³s½u°O¿ý¡A¥]¬Asamba¡BFTP¡BAFP¡BHTTP¡BHTTPS¡BTelnet¤ÎSSH¡A¥H¤Î³z¹Lºô¸ôªA°Èµn¤J¨t²Îªº½u¤W¨Ï¥ÎªÌ³s½u¸ê°Tµ¥¡AÅýºÞ²zªÌ¯à°÷®e©öºÞ²z¨Ã´x´¤©Ò¦³ªº¸Ô²Óª¬ªp¡C

¡´¸ÔºÉªº¨t²Î¸ê°T
¦øªA¾¹ºÞ²z­û¯à°÷³z¹LºÞ²zªÌ¨Ï¥Î­¶­±´x´¤¸ÔºÉªº¨t²Î¸ê°T¡A¨Ò¦p¡GCPU¨Ï¥Î²v¡B©Ò¦³°O¾ÐÅé¤Î¥i¨Ï¥ÎªºªÅ¶¡¡Bµo°e±µ¦¬¤Î¿ù»~ªº«Ê¥]¼Æ¡B¨t²Î¶}¾÷¡BCPU·Å«×¡B¨t²Î·Å«×¡BµwºÐ·Å«×¤Î¨t²Î­·®°ªºÂà³tµ¥¡C

¡´°ªµwÅéÂX¥R©Ê
TS-410U¤ä´©4­ÓUSB 2.0°ð¤Î 2 ­Ó eSATA °ð¡A±z¥i¥H³s±µ¥~±µÀx¦s¸Ë¸m¦ÜTurbo NAS³Æ¥÷¸ê®Æ©ÎÂX¥R¨t²ÎªºÀx¦s®e¶q¡C
¡@


QNAP«ÂÁp³q
TS-410U Turbo NAS - ServerBank¸ê°T±ÄÁʺô
TS-410U
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ
Hardware Spec.
CPU Marvell 6281 800MHz
DRAM 512MB DDRII RAM
Flash Memory 16MB
HDD 4 x 3.5" or 2.5¡¨ SATA I/II HDD
NOTE:
  1. The system is shipped without HDD.
  2. For the HDD compatibility list, please visit http://www.qnap.com/pro_compatibility.asp
HDD Tray 4 x hot-swappable and lockable tray
LAN Port 2 x Gigabit RJ-45 Ethernet port
LED Indicators USB, Status, HDD 1, HDD 2, HDD 3, HDD 4, LAN
USB 4 x USB 2.0 port (Front: 1; Back: 3)
Supports USB printer, disk, pen drive, USB hub, and USB UPS, etc.
eSATA 2 x eSATA port (Back)
Buttons System: Power button, USB one-touch-backup button, reset button
Alarm Buzzer System warning
Form Factor Rackmount
Dimensions 44(H) x 439(W) x 483(D) mm
1.73(H) x 16.97(W) x 19.02(D) inch
Weight Net weight: 6.7 Kg (14.77 lbs)
Gross weight: 11.06 Kg (24.38 lbs)
Sound Level (dB) W/o HDD installed: 33 dB
Stand by: 33.2 dB
In operation: 35.1dB
(Background: 25.5 dB)
Power Consumption (W) Sleep mode: 14W
In operation: 28W
(with 4 x 500GB HDD installed)
Temperature 0~40˚C/ 32~104¢XF
Humidity 0~95% R.H.
Power Supply Input: 100-240V AC, 50/60Hz, Output: 250W
Fan 3 x quiet cooling fan (4 cm, 12V DC)

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQNAP«ÂÁp³q - TS-410U - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºQNAP«ÂÁp³q - TS-410U Turbo NAS±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 NASºô¸ôÀx¦sÀɮצøªA¾¹
 ServerBank±ÀÂ˾÷ºØ
 ®à¤W«¬
 ¾÷¬[¦¡
 ª½¥ß¦¡
 ºÏºÐ°}¦C°t¥ó
 ¦Û°Ê¥úºÐ«þ¨©¾÷
 ¥~±µ¦¡µwºÐ
 ºÏ±a¾÷
 SDLT
 DLT
 LTO 1/2/3/4
 Ultrium I
 Ultrium II
 SAIT
 AIT
 AIT Turbo
 DAT
 DDS
 ºÏ±a´«±a¾÷Autoloader
 iSCSI¸Ñ¨M¤è®×
 iSCSIºÏºÐ°}¦C
 iSCSI¾ô±µ¾¹
 ºÏºÐ°}¦CRAID
 ServerBank±ÀÂ˾÷ºØ
 iSCSI
 iSCSI to SAS
 SATA
 SCSI-to-SCSI
 SCSI-to-IDE
 SCSI-to-SATA
 Fibre-to-SCSI
 Fibre-to-IDE
 Fibre-to-SATA
 Fibre-to-Fibre
 Fibre to SAS
 USB-to-IDE
 SATA-to-SATA
 SATA-to-IDE
 SAS
 IDE-to-IDE
 1394-to-IDE
 JBOD
 ºÏºÐ°}¦CÂd
 1394B-to-SATAII
 1394B-to PATA
 °ïÅ|¦¡Àx¦s¥~±µ²°
 SAS-to-SATA
 SAS-to-SAS
 SCSI-to-SAS
 PCIE
 USB
 IDE
 SAN¸Ñ¨M¤è®×
 ¥úÅÖ³q¹D¥æ´«¾¹
 ¥úÅÖ³q¹D¤¶­±¥d
 SAN Storage
 SAN Software
 ¥úÅÖ³q¹D¾ô±µ¾¹
 ¾É¦V¾¹director
 ¥úÅÖ¼Ò²Õ
 Àx¦sºÞ²z³nÅé
 ºÏ±aÂd
 ºÏ±a
 ¦Û°Ê´«¤ù¥úºÐ
 ÂÅ¥ú¥úºÐÂd
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > Àx¦s³]³Æ/³Æ¥÷¤è®×


QNAP«ÂÁp³qTS-410U

TS-410U Turbo NAS


¼tµP¡GQNAP«ÂÁp³q      >>ÂsÄýQNAP«ÂÁp³q¥þ³¡²£«~
«¬¸¹¡GTS-410U



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQNAP«ÂÁp³q - TS-410U - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºQNAP«ÂÁp³q - TS-410U Turbo NAS±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óQNAP«ÂÁp³q¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§QNAP«ÂÁp³q²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§QNAP«ÂÁp³q­ì¼t°t¥ó


¡@

¡@

¡@

¯S¦â:

¡´¥þ·sªº¨Ï¥ÎªÌ¤¶­±

Âù Gigabit ºô¸ôºÝ¤f¤ä´©¦h¶µ³]©w
ºô¸ô®e¿ù (Failover)
ºô¸ô®e¿ù´£¨Ñ¤F¤£¶¡Â_ªººô¸ôªA°È¡A·í¨â­Óºô¸ôºÝ¤f³£³s¤Wºô¸ô®É¡A¤@±øºô¸ô½uµo¥Í¬G»Ù°ÝÃD®É¡A¥t¤@±ø¥i¥HÄ~Äò´£¨Ñºô¸ôªA°È¡C

¡´ºô¸ô­t¸ü¥­¿Å (Load-Balancing)
TS-410U ¤ä´©Bandwidth aggregation¡A¼W¥[Àɮתº¶Ç¿é³t²v(»Ý­n·f°t¤ä´©802.3ad³]©wªº¤A¤Ó¥æ´«¾¹)¡C

¡´Âùºô¸ô IP ³]©w
TS-410U ¥i¥H³]©w¨â­Ó¤£¦Pªº IP¡A¨Ã¦P®ÉªA°È¦b¨â­Ó¤£¦P¤lºô¬qªº¤u§@¸s²Õ¡C

±M·~¯Åªº°ª®Ä¯à¡B°ªÃ­©w©Ê¤Î¨ã¨aÃø¨¾½d¾÷¨îªººô¸ôÀx¦s¦øªA¾¹
¥ý¶iªºRAIDºÏºÐ°}¦CºÞ²z¤Î¤ä´©¼ö©â´«³]­p
¬°¤F½T«O¸ê®Æªº¦w¥þ©Ê¡ATS-410U ´£¨Ñ¥ý¶iªºRAIDºÏºÐ°}¦CºÞ²z¥\¯à¡A¥u­n³z¹L²³æ­¶­±³]©w§Y¥i»´ÃP§¹¦¨³]©w¡A¨ä¤¤¥]¬ARAID 0¡B1¡B5¡B6¡B5 + hot spare¡BSingle¤ÎJBOD¡C¤ä´©¼ö©â´«ªº³]­p¡A´£¨Ñ±z¤£¶¡Â_»P®e©öºûÅ@ªºªA°È¡C»â¥ý·~¬Éªº RAID ºÞ²z³]­p¡A¬Û¤ñ©ó¨ä¥¦«~µPªºNAS¡A¥i¥H®e³\§ó¦h¤@ÁûªºµwºÐ·l·´¡A³o¼Ëªº³]­p¥i¥H±aµ¹¨Ï¥ÎªÌ¤@­Ó§ó¦w¥þªº¸ê®ÆÀx¦sÀô¹Ò¡C

¡´½u¤WRAID®e¶qÂX¥R
RAID®e¶qÂX¥RÅý¨Ï¥ÎªÌ¥i¦b«O¯d©Ò¦³¸ê®Æ¡B¤£°±¾÷ªº±¡ªp¤U¡A¤@¨B¤@¨B¦a¶¶§Qªº¶i¦æRAID®e¶qÂX¥R¡C

¡´½u¤WRAID²ÕºA¾E²¾
½u¤WRAID²ÕºA¾E²¾Åý¨Ï¥ÎªÌ¥i³z¹L²©ö¨BÆJ¡A¦b¤£°±¾÷¥B«O¯d¸ê®Æªºª¬ºA¤U¶i¦æRAIDµ¥¯Å¾E²¾¡C

¡´³z¹LµêÀÀºÏºÐ ¡A¼u©ÊÂX¥R±zªº NAS ®e¶q
¸g¥Ñ¿W¯Sªº¡u¥~±µµêÀÀºÏºÐ¡v¡AºÞ²zªÌ¯à§ó¼u©Ê¦aÂX¥R NAS ªº®e¶q¡C³z¹L¤º«ØªºiSCSI initiator¥\¯à¨Ó³s±µºô¸ô¤W¨ä¥L iSCSI target¡A¥i±N¨äÅܦ¨¨t²Î¤WªºµêÀÀºÏºÐ¡CQNAP NAS ¥i°µ¬°°ïÅ|¥D¸Ë¸m (stack master) ¡A³s±µ¦h¹F 8 ­ÓµêÀÀºÏºÐ/°ïÅ|¥Ø¼Ð (stack targets)¡C¦]¦¹¡A©Ò¦³ªº NAS ¨Ï¥ÎªÌ¶È»Ý³s½u¦Ü¦¹³æ¤@¤J¤f¡A§Y¥i¨Ï¥Î¦ì©ó¨ä¥¦ºô¸ôÀx¦s¸Ë¸m¤WªºªÅ¶¡¡C

¡´«Ø¸m¦¨¥»¤Î°ª¼u©Êªº iSCSI ¸Ñ¨M¤è®×
«ÂÁp³qªºTS-410U¯à°÷¦P®É¤ä´©NAS¤ÎiSCSI ¸Ë¸m¹B§@¡A´£¨Ñ¤¤¤p¥ø·~¤@­Ó­Ý¨ã§C¦¨¥»°ª¼u©Ê¤Î¦³®Ä²vªºIP-SAN¸Ñ¨M¤è®×¡C¦øªA¾¹ºÞ²z­û¯à°÷¨Ï¥Î¤º«ØªºiSCSI ¸Ë¸mªA°È«Ø¥ß³Ì¦h¤K²Õ¸Ë¸m¡C¤£¦PªºiSCSIÅÞ¿è³æ¤¸¼Æ(LUNs ¡GLogical Unit Number) ¯à°÷°µ¬°²{¦³Àx¦sªÅ¶¡ªºÂX¥R©Î¬O²{¦sÀ³¥Î¦øªA¾¹ (¦p¡G¸ê®Æ®w¦øªA¾¹¡B¹q¤l¶l¥ó¦øªA¾¹)ªº³Æ¥÷¦ì¸m¡C

¡´S.M.A.R.T.¤Î¶i¶¥µwºÐª¬ºA±½´y(HHS)
Turbo NAS¤ä´©µwºÐS.M.A.R.T. (Self-Monitoring Analysis and Reporting Technology)¡A¯à°÷ºÊµøµwºÐª¬ºA¡BÀˬd¼ç¦b°ÝÃD¡A¨Ã³z¹LEmail³]©wµo¥Xĵ§i°T®§¡A´£¿ô¨Ï¥ÎªÌ¹w¥ý°µ¦n«OÅ@µwºÐ¸ê®Æªº±¹¬I¡C¦¹¥~¡ANASªº HHS (HDD Health Scanning)§Þ³N¡A¯à°÷Àˬd¨Ã±½´yµwºÐªºª¬ªp¡A¥H¹w¨¾¼ç¦b©Êªº¸ê®Æ·l¥¢¡C

§¹¾ãªº³Æ¥÷¤è®×

QNAP ¿W®a³Æ¥÷³nÅé - NetBak Replicator
QNAP´£¨Ñªº¿W®a³Æ¥÷³nÅé ¡V NetBak Replicator¡AÅý¨Ï¥ÎªÌ»´ÃP¦a³Æ¥÷Windows¹q¸£¤ºªº¸ê®Æ¦ÜTurbo NAS¡A³nÅé¤ä´©§Y®É³Æ¥÷¡B¸ê®Æ¦P¨B¤Î±Æµ{³Æ¥÷µ¥¥\¯à¡C

¡´¬Û®e²Ä¤T¤è³Æ¥÷³nÅé
QNAP NAS¬Û®e©ó¥«­±¤W¥D¬yªº³Æ¥÷³nÅé¡A¨Ò¦pAcronis True Image, CA BrightStor ARCserve Backup, EMC Retrospect, Symantec Backup Exec¤Î LaCie Silverkeeperµ¥¡C

¡´Rsync»·ºÝ³Æ¥÷
¦bTurbo NAS¸Ì­±ªº¸ê®Æ¥i¥H»·ºÝ³Æ¥÷¨ìQNAPªºNAS¨t¦C²£«~¸Ì­±¡A©Î¬OÂÇ¥ÑRsync³Æ¥÷¸ê®Æ¨ì¤ä´©Rsyncªº¦øªA¾¹¡C

¡´USB³æÁä¦Û°Ê³Æ¥÷
Turbo NASªº§Ö³t«þ¨©Áä¥i¥H³]©w¬°±Ò°Ê¥ß§Y½Æ»s¥~±µUSB¸Ë¸mªº¸ê®Æ¨ìNAS¡A©Î¬O½Æ»sNASªº¯S©w¸ê®Æ§¨¨ì¥~±µUSB¸Ë¸m(³æÁä¦Û°Ê³Æ¥÷¥\¯à¥u¦³¨Ï¥ÎNAS«e¤èªºUSB °ð¤~¥i¥H±Ò°Ê)¡C

¥ø·~°ª®Ä¯àªººÞ²z

¤ä´©Windows, Mac, Linux ¤ÎUnix ¸ó¥­¥xªºÀɮפÀ¨É
Turbo NAS±Mªù³]­p¸ó¥­¥xªº¤ä´©¡A´£¨Ñ¤£¦P§@·~Àô¹Òªº¨Ï¥ÎªÌ¯à°÷»´ÃP¦a¤À¨ÉÀɮ׸ê®Æ¡C

¡´¤ä´©Windows ADªA°È»{ÃÒ
³z¹LWindows AD ªA°Èªº»{ÃҤ䴩¡AÅý¦øªA¾¹ºÞ²zªÌ¥i¥H»´ÃP¦a±qADºô°ì¶×¤J¨Ï¥ÎªÌ±b¤á¸ê®Æ¨ìTurbo NAS¡C¤£¦ý¤j¤j¦a¸`¬Ù¤FºÞ²z­û½Æ»s±b¸¹¤Î¸s²Õªº®É¶¡¡A¨Ï¥ÎªÌ¤]¥i¥HÄ~Äò¨Ï¥Î­ì¦³ªº±b¸¹¥H¤Î±K½X¡C

¡´ºô­¶¦¡Àɮ׺޲z¤¶­±
TS-410U ´£¨Ñºô­¶¦¡Àɮ׺޲z¤¶­±¡AÅý±z¥i¥H³z¹LÂsÄý¾¹»´ÃP¦a¤W¶Ç¤U¸ü¤ÎºÞ²z¦øªA¾¹¤ºªºÀɮסC

¡´»´ÃP¦a§@¨Ï¥ÎªÌ±b¸¹¥H¤Î¸ê®Æ§¨ºÞ²z
NAS¤ä´©§å¦¸«Ø¥ß¨Ï¥ÎªÌ¥H¤Î¹ïÀ³ªº¨Ï¥ÎªÌ±M¥ÎÀɮק¨¡A¹ï©ó¦øªA¾¹ºÞ²zªÌ¨Ó»¡¡A³o¬O¸`¬Ù®É¶¡ªº¤@¤jºÖ­µ¡C¦b¦w¥þªº¦Ò¶q¤U¡A¦øªA¾¹ºÞ²zªÌ¥i¥H¦b Windowsªººô¸ôÀô¹Ò§@ÁôÂéάO¶}±Ò¤À¨ÉÀɮק¨ªº³]©w¡C

Áo©úªº¹q·½ºÞ²z

¡´µwºÐ«Ý¾÷³]©w
¨Ï¥ÎªÌ¯à°÷³]©wµwºÐ¦b¯S©w®É¶¡µL¶i¦æ¸ê®Æ¦s¨ú®É§Y¶i¤J«Ý¾÷ªº³]©w¡C

¡´¹q·½¶}Ãö¾÷±Æµ{ºÞ²z
¦¹¥\¯àÅý¨Ï¥ÎªÌ¼u©Ê¤Æ¦a³]©wNASªº¶}Ãö¾÷®É¶¡¡A±z¥i¥H¨Ì·Ó¤u§@®É¶¡¡A³]©w¦b¥ô¦ó®É¶¡§@¦Û°Ê¶}¾÷¡BÃö¾÷©Î¬O­«·s±Ò°Êµ¥¡C

¡´UPS¤£Â_¹q¨t²Î¤ä´©
Turbo NAS¤ä´©USB¤£Â_¹q³]³Æ (usb-hid ups)¡AÅý¨Ï¥ÎªÌ¦b¥¼¹w´ÁªºÂ_¹q®É¡A¯à°÷¤Î®É°µ³B²z¡AÁקK­«­n¸ê®Æªº¿ò¥¢¡C¦P®É¤]¤ä´©·í¥«¹qµo¥Í²§±`®É¨t²Î¶i¤J«Ý¾÷¼Ò¦¡ªº®É¶¡¡C·í¥«¹q«ì´_¨Ñ¹q®É¡A¨t²Î ¥i¥H¦Û°Ê¦^´_¨ìÂ_¹q«eªºª¬ºAÄ~Äò¨Ï¥Î¡C

¡´¤ä´©AC¹q·½¦^´_®É¡A¨t²Î¹q·½³B²z¤è¦¡³]©w
TS-410U ¤ä´©¥«¹qÂ_¹q«á¹q·½«ì´_®É¨t²Îªº³B²z¤è¦¡¡C§A¥i¥H³]©w¦^´_¦Ü«e¤@¦¸ªº¶}¾÷©ÎÃö¾÷ª¬ºA¡C

¦w¥þ¸ê®ÆÀx¦s¡B¦s¨ú¤Î¤À¨É

IP¦ì§}¹LÂoºÞ²z¡GºÞ²zªÌ¥i¥H¤¹³\©Î¬O©Úµ´¯S©wªºIP¦ì§}³s±µ¨ìTurbo NAS¡C
SSL ¦w¥þ©ÊºÞ²z (HTTPS)¡GºÞ²zªÌ¥i¥H³z¹Lºô­¶¦w¥þ¦a¦s¨ú¤ÎºÞ²z¸ê®Æ¡C
³z¹LSSH (Secure Shell)¡A»·ºÝµn¤JTurbo NAS¡C
¥[±K FTP¡G³z¹LSSL/ TLS (explicit) ¥[±K¨Ó¤À¨É¤Î¶Ç¿é±zªº¸ê®Æ¡C ¨Ã¥B¤ä´©FTP³Q°Ê¼Ò¦¡¤ÎÀW¼eºÞ²z¡C
´¼¼z«¬FTPºÞ²z¡GºÞ²zªÌ¥i©Ò¦³FTP³s½u¤Î­Ó§O±b¸¹ªº³s½u¤W­­¡C
¥[±K²§¦a³Æ´©¡GTurbo NASªº¸ê®Æ¥i¥H³z¹Lºô¸ô¥[±K³Æ¥÷¨ì¨ä¥LªºQNAP NAS¨t¦C²£«~¡C
FTP¼g¤J(Write-only)Åv­­³]©w¡G¦øªA¾¹ºÞ²z­û¥i¥H°w¹ï¨Ï¥ÎªÌ°µ¶È¦³³z¹LFTP¤W¶Ç¸ê®Æ¨ìNAS¦ýµLªk½s¿è©Î¬O¤U¸ü¸ê®ÆªºÅv­­³]©w¡C
¡´ºô¸ô¦Û°ÊIP³s½u¹LÂo
¬°¨¾½dNAS¾D¨ü¨ìºô¸ô´c·N¤J«I¡A¦øªA¾¹ºÞ²z­û¯à°÷«Ø¸m¤¹³\¡B©Úµ´©Î¬O¦Û°Ê«ÊÂê³z¹LSSH/ Telnet/ HTTP(S)/ FTP/ samba/ AFPªº¦Û°Ê³s½u¹LÂo¾÷¨î¡A§ó¥[±j¤Æºô¸ôªº¦w¥þ¨¾Å@¡C

¥\¯à±j¤jªº¨t²ÎºÞ²z¤u¨ã

¡´´¼¼z«¬­·®°
­·®°ªºÂà³t¯à°÷®Ú¾Ú¥Ø«eªº¨t²Î·Å«×¦Û°Ê¦a°µ½Õ¾ã¡CºÞ²zªÌ¦P®É¯à°÷³z¹L¤â°Ê©w¸q°ªÂà¤Î§CÂ઺³]©w¡C

¡´§Y®ÉSMS/ Emailĵ°T³qª¾
¦øªA¾¹ºÞ²z­û¥i¥H³z¹LSMTP¤ÎSMSC(Short Message Service Center)ªº³]©w¡A¥ß§Y±µ¦¬§Y®ÉEmail¤Î²°T³qª¾¡AÀH®ÉÀH¦a»´ÃP´x´¤NASªº³Ì·sª¬ºA¡C

¡´SNMP (²³æºô¸ôºÞ²z¨óij)
²³æºô¸ôºÞ²z¨óij (SNMP) ¯à°÷¤ä´©ºô¸ôºÞ²z¨t²Î¡A¥Î¥HºÊ´ú³s±µ¨ìºô¸ô¤Wªº³]³Æ¡]¨Ò¦p¡GNAS¡^¡C±z¥i¥H³]©w SNMP trap ¨Ó´£¨Ñĵ¥Ü¡A³Ì¦h¥i³]©w¤T²Õ SNMP trap ¦ì§}¡C¦¹¥~¡A±z¤]¥i¥H¦b SNMP ³]©w¤¤¡A¦Û¦æ©w¸q¨t²Î¨Æ¥ó°O¿ý¤§µ¥¯Å¡C

¡´¤ä´©SSL (Secure Sockets Layer)¦w¥þ¾ÌÃÒ
ºÞ²zªÌ¯à°÷¤W¶Ç¸g»{¥iªº¦w¥þ¾ÌÃÒ¤ÎX.509PEM®æ¦¡ªºRSA¨p¤Hª÷Æ_Åý¨Ï¥ÎªÌ¯à°÷³z¹LSSLµn¤J¨Ó¦s¨úNASªº¸ê®Æ¡C

¡´¤ä´©¨t²Î¤é»x(Syslog)¦øªA¾¹³]©w
³z¹L¦¹³]©w¡A©Ò¦³NASªº¨Æ¥ó°O¿ý¤Î³s½u¬ö¿ý¯à°÷³QÀx¦s¨ì»·ºÝ¨t²Î¤é»x(Syslog)¦øªA¾¹¤¤¡C

¡´ºô¸ô¸ê·½¦^¦¬µ©
¦bNASºô¸ô¸ê®Æ§¨ùاR°£ªºÀÉ®×±N·|³Q²¾¨ì¯S©wªº¸ê·½¦^¦¬¸ê®Æ§¨¡C³z¹L³o¼Ë¥\¯à¡A±z¥i¥HÀH®É¦^¦s±z¤£¤p¤ß§R°£ªºÀɮסC

¡´¹d²ÓÃû¿òªº¨Æ¥óºÞ²z¨t²Î
Turbo NASªº©Ò¦³³s½u°O¿ý¡A¥]¬Asamba¡BFTP¡BAFP¡BHTTP¡BHTTPS¡BTelnet¤ÎSSH¡A¥H¤Î³z¹Lºô¸ôªA°Èµn¤J¨t²Îªº½u¤W¨Ï¥ÎªÌ³s½u¸ê°Tµ¥¡AÅýºÞ²zªÌ¯à°÷®e©öºÞ²z¨Ã´x´¤©Ò¦³ªº¸Ô²Óª¬ªp¡C

¡´¸ÔºÉªº¨t²Î¸ê°T
¦øªA¾¹ºÞ²z­û¯à°÷³z¹LºÞ²zªÌ¨Ï¥Î­¶­±´x´¤¸ÔºÉªº¨t²Î¸ê°T¡A¨Ò¦p¡GCPU¨Ï¥Î²v¡B©Ò¦³°O¾ÐÅé¤Î¥i¨Ï¥ÎªºªÅ¶¡¡Bµo°e±µ¦¬¤Î¿ù»~ªº«Ê¥]¼Æ¡B¨t²Î¶}¾÷¡BCPU·Å«×¡B¨t²Î·Å«×¡BµwºÐ·Å«×¤Î¨t²Î­·®°ªºÂà³tµ¥¡C

¡´°ªµwÅéÂX¥R©Ê
TS-410U¤ä´©4­ÓUSB 2.0°ð¤Î 2 ­Ó eSATA °ð¡A±z¥i¥H³s±µ¥~±µÀx¦s¸Ë¸m¦ÜTurbo NAS³Æ¥÷¸ê®Æ©ÎÂX¥R¨t²ÎªºÀx¦s®e¶q¡C
¡@


QNAP«ÂÁp³q
TS-410U Turbo NAS - ServerBank¸ê°T±ÄÁʺô
TS-410U
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ
Hardware Spec.
CPU Marvell 6281 800MHz
DRAM 512MB DDRII RAM
Flash Memory 16MB
HDD 4 x 3.5" or 2.5¡¨ SATA I/II HDD
NOTE:
  1. The system is shipped without HDD.
  2. For the HDD compatibility list, please visit http://www.qnap.com/pro_compatibility.asp
HDD Tray 4 x hot-swappable and lockable tray
LAN Port 2 x Gigabit RJ-45 Ethernet port
LED Indicators USB, Status, HDD 1, HDD 2, HDD 3, HDD 4, LAN
USB 4 x USB 2.0 port (Front: 1; Back: 3)
Supports USB printer, disk, pen drive, USB hub, and USB UPS, etc.
eSATA 2 x eSATA port (Back)
Buttons System: Power button, USB one-touch-backup button, reset button
Alarm Buzzer System warning
Form Factor Rackmount
Dimensions 44(H) x 439(W) x 483(D) mm
1.73(H) x 16.97(W) x 19.02(D) inch
Weight Net weight: 6.7 Kg (14.77 lbs)
Gross weight: 11.06 Kg (24.38 lbs)
Sound Level (dB) W/o HDD installed: 33 dB
Stand by: 33.2 dB
In operation: 35.1dB
(Background: 25.5 dB)
Power Consumption (W) Sleep mode: 14W
In operation: 28W
(with 4 x 500GB HDD installed)
Temperature 0~40˚C/ 32~104¢XF
Humidity 0~95% R.H.
Power Supply Input: 100-240V AC, 50/60Hz, Output: 250W
Fan 3 x quiet cooling fan (4 cm, 12V DC)

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQNAP«ÂÁp³q - TS-410U - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºQNAP«ÂÁp³q - TS-410U Turbo NAS±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@