Scale to more than
1,100TB of raw storage capacity.
Consolidate hundreds
of your enterprise-wide applications.
Prioritize critical
workloads for fast response.
Back up application
data in seconds; recover in just minutes using our Snapshot™ and
SnapManager® software.
|
NetApp NetApp FAS6000 Series (FAS6040) - ServerBank¸ê°T±ÄÁʺô FAS6040 Àx¦s³]³Æ/³Æ¥÷¤è®×
¡@
²£«~³W®æ |
Operating
System |
NetApp Data ONTAP®
7.2.4 or later software |
Operating
Systems Supported |
Windows® 2000,
Windows Server 2003, Windows Server 2008,
Windows XP, Linux®, Sun™ Solaris™, AIX, HP-UX,
Mac® OS, VMware, ESX |
Standard
Software Features |
Integrated
automatic RAID manager, including RAID-DP™, Snapshot™,
Fast Boot, telnet, e-mail alerts, NIS, DNS,
SNMP, FilerView®, FlexVol®,FlexShare™,
SSH, Maintenance Center, Network Data Management
Protocol (NDMP) |
File
Service and Other Protocol Support |
NFS V2/V3/V4 over
UDP or TCP, PCNFSD V1/V2 for (PC) NFS client
authentication, Microsoft® CIFS, HTTP 1.0, HTTP
1.1 virtual hosts |
SAN
Protocol Support |
Fibre Channel
Protocol (FCP) (8/4/2/1Gb); fabric-attached and
direct-attached; IP SAN (iSCSI), Fibre Channel
over Ethernet (FCoE) |
Licensed
Software Products |
FlexClone™, FlexCache, MultiStore®, SnapMirror®, SnapRestore®,
SnapDrive®, SnapManager®
for Microsoft Exchange, SnapManager for
Microsoft SQL Server, SnapManager for
Oracle®, Single
Mailbox Recovery, SnapVault®,
SnapMover®, SnapLock®
Compliance, SnapLock Enterprise, SyncMirror®, MetroCluster, NearStore®
Personality Option, CommandCentral™
Storage, Protection
Manager2 ,File
Storage Resource Manager,
SAN Manager, Operations
Manager3,
ApplianceWatch™ for HP Openview, ApplianceWatch
for Tivoli® |
Standard
Hardware Features |
ROHS-compliant,
full-duplex 10/100/1000Base-T Ethernet onboard
console, diagnostic LED/LCD, Remote LAN
Management (RLM) Card standard, redundant
hot-plug cooling fans, redundant hot-plug power
supplies, Compact Flash, 19" rack-mount
enclosure, optional 220 V 42U 19" system cabinet |
Maximum
RAID Group Sizes |
RAID 6 (RAID-DP)
FC ¡V 28 (26 data disks plus 2 parity disks),
SATA ¡V 16 (14 data disks plus 2 parity disks)
RAID 44 FC
¡V 14 (13 data disks plus 1 parity disk), SATA ¡V
7 (6 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror) |
Disk
Shelves Supported (Fibre Channel, SATA) and
Configurations |
DS14, DS14mk2 FC,
DS14mk4 FC, DS14mk2AT
Dual-path
DS4243, MPHA (MultiPath High Availability) |
Disk
Drive Capacities Supported |
FC-91/181/361/721/300GB,
450GB, 600GB
SATA-500GB, 1TB, 2TB
SAS: 300GB, 450GB, 600GB |
1 9/18/36/72GB
drives are supported but not currently shipping.
2 Protection
Manager was previously known as Business Continuance
Option.
3 Operations
Manager was previously known as DataFabric® Manager
(DFM).
4 RAID
6 is the recommended configuration for drives
greater than 144GB. |
|
|
|
Active/Active
Configuration |
Single Controller |
Active/Active
Configuration |
Single Controller |
Max. Raw
Capacity(5), (6) |
1,176TB |
1,176TB |
840TB |
840TB |
Max. Number of
Disk Drives |
1,176 |
1,176 |
840 |
840 |
Max. Number of FC
Loops (dual attach) |
14 |
14 |
10 |
10 |
Max. Drives per FC
Loop |
84 |
Max.
Volume/Aggregate Size |
16TB |
Max. Number of
LUNs per Controller |
2048 |
ECC Memory |
64GB |
32GB |
32GB |
16GB |
Nonvolatile Memory |
4GB |
2GB |
1GB |
512MB |
Onboard GbE Ports |
12 |
6 |
12 |
6 |
Onboard 4Gb
FC Ports (target or initiator)7 |
16 |
8 |
16 |
8 |
5 Max.
capacity is derived based on the type, size, and
number of the drives.
6 Max.
capacity is calculated using Base10 arithmetic
(i.e., 1TB = 1,000,000,000,000 bytes).
7 Autosensing
ports: 1, 2, 4Gb. |
|
|
|
Active/Active
Configuration |
Single
Controller |
Active/Active
Configuration |
Single
Controller |
PCI Express
Expansion Slots |
10 |
5 |
10 |
5 |
PCI-X Expansion
Slots |
6 |
3 |
6 |
3 |
Optional Network Connectivity (max.)
Quad GbE TOE (copper) Cards
Quad GbE (copper) Cards
Single 10GbE TOE (fiber) 10GBASE-SR Cards
Dual 10GbE TOE (fiber) 10GBASE-SR Cards
Dual GbE (copper or fiber) Cards
Dual iSCSI (copper or fiber) Adapters |
10
10
4
10
10
6 |
5
5
2
5
5
3 |
10
10
4
10
10
6 |
5
5
2
5
5
3 |
Dual 4Gb FC
Initiator Adapters (max.) |
10 |
5 |
10 |
5 |
Quad 4Gb FC
Initiator Adapters (max.) |
10 |
5 |
10 |
5 |
Dual 4Gb FC
Target (SAN) Adapters (max.) |
8 |
4 |
8 |
4 |
Dual
10GbE FCoE (copper or fiber) Target (SAN) Adapter
(max)1 |
8 |
4 |
8 |
4 |
Dual FC, LVD
SCSI Tape Adapters (max.) |
6 |
3 |
6 |
3 |
4port SAS HBA |
¡@ |
¡@ |
¡@ |
¡@ |
Performance
Acceleration Module (PAM) |
10 |
5 |
8 |
4 |
Performance Acceleration Module II (PAM II) 512MB1 |
8 |
4 |
4 |
2 |
1Requires Data ONTAP 7.3.2
¡@ |
|
AC Power/Current
(line voltage for standalone systems dependent on
local power distribution; system cabinets are 200 to
240 V only) |
100 to 120VAC, 11.2A
(typical)
200 to 240VAC, 5.8A (typical)
19.4A (max.) @ 100VAC
9.6A (max.) @ 200VAC |
100 to 120VAC, 5.6A
(typical)
200 to 240VAC, 2.9A (typical)
9.7A (max.) @ 100VAC
4.8A (max.) @ 200VAC |
Thermal Rating |
3740 Btu/hr, 1096W
(typical) |
1870 Btu/hr, 548W
(typical) |
Weight |
242 lb (109.6 kg) |
121 lb (54.8 kg) |
Height |
20.8" (52.8 cm), fits
into 12U space |
10.3" (26.2 cm), fits
into 6U space |
Width |
19" IEC
rack-compliant (17.53", 44.53 cm) |
Depth |
23.5" (59.7 cm),
29.05" (73.8 cm) with cable management bracket |
Operating
Temperature, Altitude, and Relative Humidity |
10¢X C to 40¢X C (50¢X F
to 104¢X F); at </= 3,000 m (at </= 10,000)
elevation; 20% to 80% relative humidity,
noncondensing (28¢X C wet bulb temperature) |
Nonoperating
Temperature and Relative Humidity |
-40¢X C to 65¢X C (-40¢X
F to 149¢X F); 10% to 95% relative humidity,
noncondensing, in original container |
Operating Acoustic
Noise |
56.5 dBA sound
pressure (LpA) @ normal operating conditions (at
22¢XC and at sea level) |
Min. Cabinet
Clearances |
1.85" (4.7 cm) for
bezel, 3" (7.6 cm) for cable radius |
Min. Service
Clearances |
25" (63.5 cm) from
front of cabinet; 40" (76 cm) from rear of cabinet |
|
|
Disk Drive Storage
Shelf |
DiskShelf14
family¡XDS14, DS14mk4 FC, and DS14mk2AT; each w/14
low-profile slots for FC and SATA disk drives |
Disk Drive Storage
Shelf Interface |
PCI-based Fibre
Channel-Arbitrated Loop (FC-AL) |
DiskShelf14
Interface |
Dual, redundant
electronically switched hub (ESH4) modules or dual,
redundant ATA modules |
Power
Supply/Cooling Fans |
Dual, redundant,
hot-pluggable, integrated power supply/fan
assemblies (220V/110V) |
AC Power/Max.
Current |
100 to 120VAC/4.52A;
200 to 240VAC/2.23A |
Thermal Rating |
1,538 Btu/hr (fully
loaded shelf) |
Operating Acoustic
Noise |
49 dBA sound pressure
(LpA) @ normal operating conditions (at 22¢XC and at
sea level) |
Dimensions
(height/width/depth) |
3 EIA U (5.25", 13.3
cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20"
(50.85 cm) |
Weight |
77 lb (35 kg) fully
loaded |
|
|
Disk Drive Types
and Capacities Supported |
SAS 15,000 RPM:
300GB, 450GB, 600GB
SATA 7,200 RPM: 500GB, 1TB, 2 TB
All shelves have 24 bays for 3.5¡¨ low-profile SAS or
SATA disk drives |
Disk Enclosure to
Controller Interface |
Serial Attached SCSI
(SAS) operating at 3Gb, requires PCIe SAS Host Bus
Adapter card or available embedded SAS port |
Disk Enclosure
Configurations |
Dual IOM3
(Input/Output Module) Controller modules |
Power
Supply/Cooling Fans |
Dual (SATA) or
quadruple (SAS), redundant, hot-pluggable,
integrated power supply/fan assemblies |
Operating
Temperature Range |
41¢XF to 104¢XF - (5¢XC
to 40¢XC) |
Nonoperating
Temperature Range |
34¢XF to 122¢XF - (1¢XC
to 50¢XC) |
Relative Humidity |
20 to 80%
noncondensing |
Operating Acoustic
Noise |
6.6B LwA @ 20¢XC |
Input power
frequency, Hz (AC) |
50 to 60 |
Dimensions
(height/width/depth) |
4 EIA U (7¡¨, 17.8
cm)/19¡¨ IEC rack-compliant (19¡¨, 48.3 cm)/24¡¨ (61
cm) |
Clearance
Dimensions (front-cooling/rear-cooling and
maintenance/front-maintenance) |
6¡¨ (15.3cm)/12¡¨
(30.5cm)/25¡¨ (55.9cm) |
Weight |
110 lb (49.9 kg)
fully loaded, 53.7 lbs (24.4 kb) without disk drives |
|
|
Vendor |
Model |
Brocade |
Silkworm 2400/2800 (TapeSAN
only) |
Brocade |
Silkworm
3200/3250/3800/3850/3900/4100/12000/24000/200E/5000/48000 |
McData |
ES 3016/3032,
Intrepid 6064/6140/ED-5000, Sphereon
3216/3232/4300/4400/4500/4700 |
Cisco |
MDS
9120/9140/9216/9506/9509/9513/9020/9124/9222i/9134 |
Qlogic |
5600/5602 |
FC = Fibre Channel;
LVD = Low Voltage Differential. |
|
|
Includes 2
Sets of Dual 16A, Zero U Power Distribution Units (PDUs)
or 1
Set of 24A Zero U PDUs |
Accommodates 1
controller and 12 disk shelves or 2 controllers and
10 disk shelves or 14 disk shelves
1 controller and 10 disk shelves or 2 controllers
and 6-8 disk shelves or 11-14 disk shelves only |
AC Power |
200 to 240VAC |
Current |
32A total-2 redundant
sets of dual 16A cables with NEMA L6-20 or IEC 309
connectors or Australia AS/NZ53123-20; 24A total-2
redundant cables with NEMA L6-30 or IEC 309
connectors |
Dimensions
(height/width/depth) |
78.75" (200 cm)/23.6"
(60 cm)/37.4" (95 cm) |
Min. Clearances |
48" (122 cm) front
and rear |
Shipping Height |
90.6" (230 cm) |
Weight (empty) |
275 lb (125 kg) |
|
|
Safety/Emissions/Immunity |
Safety: EN 60950, CE,
CSA 60950, UL 60950, CB IEC60950-1 (all national
deviations), EN60825-1, IRAM, GOST-R, BSMI
Emissions/Immunity: FCC Part 15 Class A, ICES-03,
CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN55024,
EN61000-3-2, EN61000-3-3, CoC (South Africa), BSMI |
|
¡D¥»¤å¥óªº¸ê°TY¦³×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ùY¦³»~¡A¥Hì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨äì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C
º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á!
ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶WÈÀu´fªºNetApp - FAS6040 - Àx¦s³]³Æ/³Æ¥÷¤è®×
,³Ì¦nªºNetApp - NetApp FAS6000 Series (FAS6040)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
|
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§ÚÌ·|¬°±z¦Vì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú̳£¥i¼u©Ê°t¦X±zªº»Ýn³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G
1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901 |
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»¶ÁʶR¸ß»ù§ÚÌ·|¥ß§Y»P±zÁpô! |
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw |
|
¥I´Ú¤è¦¡¡G¦p«È¤á¬°º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C |
¶Ç¯uq³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨qÁʵ{§Ç¡A§ÚÌ·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{q³æ¡C |
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú̦¬¨ì±zq³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C |
°e³f¤è¦¡¡G(1) ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C |
°e³f½d³ò¡G¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±zt¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C |
°â«áªA°È¡GY²£«~¥»¨·å²«©Î¹B°e¹Lµ{¾ÉP·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C |
«O©T¬Fµ¦¡G ¹ê»Ú¥Hì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C |
¤O±ô¸ê°T ServerBank Inc. ²¤¶
¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G
»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶Û¡B¥xÆWªFªÛ¡B¥xÆW^¸â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B
¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B
ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B
¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B
Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B
¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B
´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B¸ºÐ¼s¼½¡B·¼é°Û¤ù¡B®É³ø©P¥Z¡B
±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B
²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡Bì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°
¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B
ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B
¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B
¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤±]±¶¹B¡B¥xÆW´¼¼z¥d¡B
¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½^¡B¿ßÀYÆN
©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B
x¤è¡G ªÅx¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B
|
|
|
|
|
|
|