Technical details
PRIMERGY RX100 S8
Base unit RX100 S8 LFF RX100 S8 LFF RX100 S8 SFF RX100 S8 SFF
RX100 S8 SFF 10xSFF
Housing types Rack Rack Rack Rack Rack
Storage drive architecture 3.5-inch SAS/SATA 3.5-inch SAS/SATA
2.5-inch SAS/SATA 2.5-inch SAS/SATA 2.5-inch SAS/SATA
Power supply Standard Hot-plug Standard Hot-plug Hot-plug
Mainboard
Mainboard type D3229
Chipset Intel® C226
Processor quantity and type 1 x Intel® Xeon® processor E3-1200v3
product family / Intel® Core™ i3 processor / Intel® Pentium® processor
Processor Intel® Celeron® processor G1820
(2C/2T, 2.70 GHz, TLC: 2 MB, Turbo: No, 1,333 MHz, 54 W)
Intel® Core™ i3-4330 processor
(2C/4T, 3.50 GHz, TLC: 4 MB, Turbo: No, 1,600 MHz, 54 W)
Intel® Pentium® processor G3420
(2C/2T, 3.20 GHz, TLC: 3 MB, Turbo: No, 1,600 MHz, 54 W)
Intel® Xeon® processor E3-1220v3
(4C/4T, 3.10 GHz, TLC: 8 MB, Turbo: Yes, 1,600 MHz, 80 W)
Intel® Xeon® processor E3-1230Lv3
(4C/8T, 1.80 GHz, TLC: 8 MB, Turbo: Yes, 1,600 MHz, 25 W)
Intel® Xeon® processor E3-1230v3
(4C/8T, 3.30 GHz, TLC: 8 MB, Turbo: Yes, 1,600 MHz, 80 W)
Intel® Xeon® processor E3-1240v3
(4C/8T, 3.40 GHz, TLC: 8 MB, Turbo: Yes, 1,600 MHz, 80 W)
Intel® Xeon® processor E3-1265Lv3
(4C/8T, 2.50 GHz, TLC: 8 MB, Turbo: Yes, 1,600 MHz, 45 W)
Intel® Xeon® processor E3-1270v3
(4C/8T, 3.50 GHz, TLC: 8 MB, Turbo: Yes, 1,600 MHz, 80 W)
Intel® Xeon® processor E3-1280v3
(4C/8T, 3.60 GHz, TLC: 8 MB, Turbo: Yes, 1,600 MHz, 82 W)
Memory slots 4 (2 banks with 2 DIMMs each)
Memory slot type DIMM (DDR3) UDIMM
Memory capacity (min. - max.) 2 GB - 32 GB
Memory protection ECC
Memory notes Dual channel support. For dual channel performance,
a minimum of 2 memory modules have to be ordered. Capacity
per channel has to be the same.
Memory options 2 GB (1 module(s) 2 GB) DDR3, unbuffered, ECC,
1,600 MHz, PC3-12800, DIMM, single rank
4 GB (1 module(s) 4 GB) DDR3, unbuffered, ECC, 1,600 MHz,
PC3-12800, DIMM, dual rank
8 GB (1 module(s) 8 GB) DDR3, unbuffered, ECC, 1,600 MHz,
PC3-12800, DIMM, dual rank
Interfaces
USB 2.0 ports 4 x (2x rear, 2x internal) (10x SFF base unit: 1x
front, 2x rear, 2x internal)
USB 3.0 ports 4 x (2x front, 2x rear) (10x SFF base unit: 2x
rear)
Graphics (15-pin) 1 x VGA (15-pin) / optional 1 x front VGA (not
for 10x 2,5¡¨ HDD base unit)
Serial connection 1 x serial RS-232-C, usable for iRMC S4 or
system or shared
LAN / Ethernet (RJ-45) 2 x Gbit/s Ethernet
Management LAN (RJ45) 1 x dedicated management LAN port for iRMC
S4 (10/100/1000 Mbit/s)
Management LAN traffic can be switched to shared onboard Gbit
LAN port
Onboard or integrated Controller
RAID controller Integrated RAID 0/1 or RAID 5/6 controller
(option)
additional RAID controller options are described under
Components RAID controller
Data Sheet FUJITSU Server PRIMERGY RX100 S8 Mono socket 1U rack
server
Page 4 / 9 www.fujitsu.com/fts
Onboard or integrated Controller
SATA Controller Intel® C226, 1 port used for accessible drive
4 port for internal SATA HDDs with RAID 0, 1, 10 for Windows and
Linux;
LAN Controller Intel® i210 onboard, 2 x 10/100/1000 Mbit/s
Ethernet (TCP/IP acceleration), iSCSI, PXE-Boot and WoL are supported
Remote Management Controller Integrated Remote Management
Controller (iRMC S4, 256 MB attached memory incl. graphics controller)
IPMI 2.0 compatible
Trusted Platform Module (TPM) optional TPM
Onboard or integrated Controller (Base unit specific)
RAID controller 4 port SATA with RAID 0/1/10 for HDDs 4 port
SATA with RAID 0/1/10 for HDDs
SATA Controller 4-port SATA 6Gb with RAID 0, 1, 10 4-port SATA
3GB with RAID 0, 1, 10
SATA controller type notes for hot-plug SATA hard disks for
hot-plug SATA hard disks
Slots
PCI-Express 3.0 x8 2 x Low profile Length 175mm; PCIe slot#1 =
dedicated Modular RAID slot
PCI-Express 2.0 x4 (mech. x8) 1 x Low profile
Slot Notes Optional support of 1x full height PCIe Gen3 x8 card,
instead of 1x PCIe Gen2 x4 and 1x PCIe Gen3 x8
Drive bays
Storage drive bays 4/8 x 2.5-inch hot-plug SAS/SATA or 4x
3.5-inch hot-plug SAS/SATA or 10 x 2.5-inch hot-plug SAS/SATA as soon as
released
Accessible drive bays 1 x 5.25/0.4-inch for CD-RW/DVD
Notes accessible drives Following limitations applies to 10x
2.5-inch HDD base unit: No CD-RW/DVD, 1x USB 2.0 at the front, no front VGA
Drive bays (Base unit specific)
Storage drive bays Max. 4x 3.5-inch Max. 8x 2.5-inch Max. 10x
2.5-inch
Number of fans 4
Fan notes 4 fans in combination with standard power supply or 5
fans in combination with hot-plug PSU base unit for 1+4
redundancy.
Number of fans 4 5 4 5
Fan configuration 4 standard fan 5 redundant fan 4 standard fan
5 redundant fan
Fan notes non redundant / non hotplug
redundant / non hot-plug non redundant / non hotplug
redundant / non hot-plug
Operating panel
Operating buttons On/off switch
NMI button
Reset button
Status LEDs System status (orange)
Identification (blue)
Hard disks access (green)
Power (green)
At system rear side:
System status (orange)
Identification (blue)
LAN connection (green)
LAN speed (green / yellow)
BIOS
BIOS features ROM based setup utility
Recovery BIOS
BIOS settings save and restore
Local BIOS update from USB device
Online update tools for main Windows and Linux versions
Local and remote update via ServerView Update Manager
Remote PXE boot support
Remote iSCSI boot support
Data Sheet FUJITSU Server PRIMERGY RX100 S8 Mono socket 1U rack
server
Page 5 / 9 www.fujitsu.com/fts
Operating Systems and Virtualization Software
Certified or supported operating
systems and virtualization software
VMware vSphere™ 5.1 Embedded
Microsoft® Hyper-V Server 2012 R2
Microsoft® Windows Server® 2012 R2 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Essentials
Microsoft® Windows Server® 2012 R2 Foundation
Microsoft® Windows Storage Server 2012 R2 Standard
Microsoft® Hyper-V Server 2012
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Essentials
Microsoft® Windows Server® 2012 Foundation
Microsoft® Windows Storage Server 2012 Standard
Microsoft® Hyper-V™ Server 2008 R2
Microsoft® Windows Server® 2008 R2 Datacenter
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Foundation
Microsoft® Windows® Web Server 2008 R2
Microsoft® Windows® Small Business Server 2011 Premium Add-On
Microsoft® Windows® Small Business Server Standard 2011
VMware vSphere™ 5.5 Embedded
VMware vSphere™ 5.5
VMware vSphere™ 5.1
SUSE® Linux Enterprise Server 12
SUSE® Linux Enterprise Server 11
Red Hat® Enterprise Linux 7
Red Hat® Enterprise Linux 6
Red Hat® Enterprise Linux 5
Operating system release link http://docs.ts.fujitsu.com/dl.aspx?id=d4ebd846-aa0c-478b-8f58-4cfbf3230473
Operating system notes VMware ESX hints:
- SATA RAID is not supported
- Storing virtual machines locally requires a SAS RAID
Controller
- Onboard GbE is supported on one of the two ports
Support of other Linux derivatives on demand
Red Hat® certification starting with version 5.8 / 6.4.
Server Management
Standard
Option ServerView Suite - Maintain
iRMC Advanced Pack incl. Advanced Video Redirection (AVR), video
capturing and Virtual Media
ServerView Suite - Dynamize
Virtual-IO Manager (VIOM)
ServerView Suite - Integrate
Integration pack for Fujitsu ManageNow® solution
Server Management notes Regarding dependencies for ServerView
Suite software products see dedicated product data sheets.
Dimensions / Weight
Rack (W x D x H) 482.6 mm (Bezel) / 435.4 mm (Body) x 572 x 42.8
mm
Height Unit Rack 1 U
Mounting Cable depth rack 200 mm cable depth
Weight up to 13 kg
Weight notes Actual weight may vary depending on configuration
Rack integration kit Rack integration kit as option
Data Sheet FUJITSU Server PRIMERGY RX100 S8 Mono socket 1U rack
server
Page 6 / 9 www.fujitsu.com/fts
Environmental
Operating ambient temperature 5 - 40 ¢XC
Operating temperature note Cool-Safe© Advanced Thermal Design
(above 35 ¢XC or below 10 ¢XC) depending on configuration. For detailed
information see relevant system configurator.
Operating relative humidity 10 - 85 % (non condensing)
Operating environment FTS 04230 ¡V Guideline for Data Center
(installation specification)
Operating environment Link http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Sound pressure (LpAm) 24 / 34 dB(A) (min / max idle), 28.5 / 34
db(A) (min / max operating)
Sound power (LWAd; 1B = 10dB) 3.7 / 5.1 B (min / max idle), 4.2
/ 5.5 B (min / max operating)
Noise notes Noise emissions and operation modes depend on system
configuration.
Electrical values
Power supply configuration 1x standard power supply or1x
hot-plug power supply or 2x hot plug power supplies for redundancy
Max. output of single power supply 450 W
Standard power supply output 300 W (92% efficiency)
Hot-plug power supply output 450W (94% efficiency)
Hot-plug power supply redundancy Yes
Rated voltage range 100 V - 127 V / 200 V - 240 V
Rated frequency range 50 Hz - 60 Hz
Rated current max. 4.0 A
Rated current in basic configuration 1.8 A / 0.8 A (100V / 240V)
Active power (max. configuration) 197 W
Active power note To estimate the power consumption of different
configurations use the Power Calculator of the System Architect: http://
configurator.ts.fujitsu.com/public/
Apparent power (max. configuration) 199 VA
Heat emission 709.2 kJ/h (672.2 BTU/h)
Compliance
Global CB
RoHS (Restriction of hazardous substances)
WEEE (Waste electrical and electronical equipment)
Germany GS
Europe CE Class A *
USA/Canada CSAc/us
ULc/us
FCC Class A
Japan VCCI
Russia GOST
South Korea KC
China CCC
Australia/New Zealand C-Tick
Taiwan BSMI
Compliance link http://globalsp.ts.fujitsu.com/sites/certificates
Compliance notes There is general compliance with the safety
requirements of all European countries and North America. National
approvals required in order to satisfy statutory regulations or
for other reasons can be applied for on request.
* Warning:
This is a class A product. In a domestic environment this
product may cause radio interference in which case the user
may be required to take adequate measures.