ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô >
Àx¦s³]³Æ/³Æ¥÷¤è®×
|
|
|
¡@ |
DELL Dell EqualLogic PS6210 - ServerBank¸ê°T±ÄÁʺô Dell EqualLogic PS6210 Àx¦s³]³Æ/³Æ¥÷¤è®×
¡@
·s¼Wºô¶1
|
PS6210E |
PS6210X |
PS6210XV |
PS6210XV 3.5" |
PS6210S |
PS6210XS |
Hard Disk Drives |
24 hot-pluggable 3.5" 7.2K RPM NL-SAS drives |
24 hot-pluggable 2.5" 10K RPM SAS drives |
24 hot-pluggable 2.5" 15K RPM SAS drives |
24 hot-pluggable 3.5" 15K RPM SAS drives |
24 hot-pluggable 2.5" SSDs |
7 hot-pluggable 2.5" SSDs and 17 hot-pluggable 2.5" 10K
RPM SAS drives |
Drive Capacities
¡@ |
2TB, 3TB, 4TB |
600GB, 900GB, and 1.2TB |
300GB |
600GB |
400GB and 800GB |
Combines 400GB or 800GB SSDs and 600GB or 1.2TB 10K RPM
SAS drives |
Self Encrypting Drives (SED) |
4TB 7.2K RPM NL-SAS drives |
900GB 10K RPM SAS drives |
300GB 15K RPM SAS drives |
600GB 15K RPM SAS drives |
N/A |
N/A |
System Capacities |
Up to 96TB (up to 1.536PB with 16 arrays) |
Up to 28.8TB (up to 460.8TB with 16 arrays) |
Up to 7.2TB (up to 115.2TB with 16 arrays) |
Up to 14.4TB (up to 230.4TB with 16 arrays) |
Up to 19.2TB (up to 307.2TB with 16 arrays) |
Up to 26TB (up to 416TB with 16 arrays) |
RAID Support |
RAID 6, RAID 10 and RAID 50 (for 2 TB drives). |
RAID 6, RAID 10 and RAID 50. |
RAID 6, RAID 10 and RAID 50. |
RAID 6, RAID 10 and RAID 50. |
RAID 6, RAID 10 and RAID 50. |
Accelerated RAID 6 |
Power |
AC voltage: 100-240 VAC ¡Ó10% single phase 1080W (max,
total), +5V up to 155W; +12V up to 924W;+5Vsb up to 10W
Frequency: 50/60 Hz
Power factor: 0.98 (minimum)
Power supplies: Dual, optional dual 1080W DC-DC |
AC voltage: 100-240 VAC ¡Ó10% single phase, 700 W (max,
total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W
Frequency: 50/60 Hz
Power factor: 0.98 (minimum)
Power supplies: Dual, optional dual 700W DC-DC |
AC voltage: 100-240 VAC ¡Ó10% single phase 700 W (max,
total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W
Frequency: 50/60 Hz
Power factor: 0.98 (minimum)
Power supplies: Dual, optional dual 700W DC-DC |
AC voltage: 100-240 VAC ¡Ó10% single phase, 1080W (max,
total), +5V up to 155W; +12V up to 924W;+5Vsb up to 10W
Frequency: 50/60 Hz
Power factor: 0.98 (minimum)
Power supplies: Dual, optional dual 1080W DC-DC |
AC voltage: 100-240 VAC ¡Ó10% single phase, 700 W (max,
total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W
Frequency: 50/60 Hz
Power factor: 0.98 (minimum)
Power supplies: Dual, optional dual 700W DC-DC |
AC voltage: 100-240 VAC ¡Ó10% single phase, 700 W (max,
total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W
Frequency: 50/60 Hz
Power factor: 0.98 (minimum)
Power supplies: Dual, optional dual 700W DC-DC |
OS Supported |
Microsoft Windows Server® including Hyper-V®
VMware® ESX Server™
Red Hat® Enterprise Linux® (RHEL)
SUSE® Enterprise Linux® (SLES)
Oracle® Linux®
Oracle® Solaris™
IBM® AIX®
HP-UX
Mac OS® X
Citrix® XenServer™
Novell® NetWare®
¡@
|
Physical
¡@ |
Height: 4U / 175 mm (6.87 inches)
Width: 446 mm (17.57 inches)
Depth: 580 mm (22.83 inches)
Weight: 47.1 kg (103.8 lb)** |
Height: 2U / 87 mm (3.42 inches)
Width: 446 mm (17.57 inches)
Depth: 546 mm (21.50 inches)
Weight: 26.4 kg (58.3 lb)** |
Height: 2U / 87 mm (3.42 inches)
Width: 446 mm (17.57 inches)
Depth: 546 mm (21.50 inches)
Weight: 26.4 kg (58.3 lb)** |
Height: 4U / 175 mm (6.87 inches)
Width: 446 mm (17.57 inches)
Depth: 580 mm (22.83 inches)
Weight: 47.1 kg (103.8 lb)** |
Height: 2U / 87 mm (3.42 inches)
Width: 446 mm (17.57 inches)
Depth: 546 mm (21.50 inches)
Weight: 26.4 kg (58.3 lb)** |
Height: 2U / 87 mm (3.42 inches)
Width: 446 mm (17.57 inches)
Depth: 546 mm (21.50 inches)
Weight: 26.4 kg (58.3 lb)** |
Packaged physical: Length: 905 mm (35.63 inches) Width:
607 mm (23.88 inches) Depth: 521 mm (20.50 inches)
Packaged weight: 66.0 kg (145 lbs)** |
Packaged physical: Length: 851 mm (33.50 inches) Width:
616 mm (24.25 inches) Depth: 508 mm (20.00 inches)
Packaged weight: 36.0 kg (79.3 lbs)** |
Packaged physical: Length: 851 mm (33.50 inches) Width:
616 mm (24.25 inches) Depth: 508 mm (20.00 inches)
Packaged weight: 36.0 kg (79.3 lbs)** |
Packaged physical: Length: 905 mm (35.63 inches) Width:
607 mm (23.88 inches) Depth: 521 mm (20.50 inches)
Packaged weight: 66.0 kg (145 lbs)** |
Packaged physical: Length: 851 mm (33.50 inches) Width:
616 mm (24.25 inches) Depth: 508 mm (20.00 inches)
Packaged weight: 36.0 kg (79.3 lbs)** |
Packaged physical: Length: 851 mm (33.50 inches) Width:
616 mm (24.25 inches) Depth: 508 mm (20.00 inches)
Packaged weight: 36.0 kg (79.3 lbs)** |
The following specifications apply to all EqualLogic PS6210 series
models:
Storage Controllers: Dual
controllers with 16GB non-volatile memory per controller
Network Interfaces: Management
network: One 100BASE-TX per controller
Interface ports: Two 10GBASE-T with RJ45 and two 10GbE SFP+ for
fibre or twin-ax copper cabling
Volumes: Up to
1,024
Snapshots: 512
per volume/up to 10,000 total per group
Volume connections per PS series pool/group: Up
to 1024/4096
Host Protocol: Any
standards-compliant iSCSI initiator
TCP Network Support: IPv4,
IPv6 core support
Expansion Option: Can
be combined with other EqualLogic PS Series arrays in the same SAN
group online; maximum of 16 total arrays per group that can support
a maximum of 384 drives and up to 1.536PB with the PS6210 Series.
With multigenerational capabilities, you can support up to 10
cross-generation types of controllers with multiple network
configurations and drive types in a new or existing EqualLogic SAN
resource pool, all managed by a single interface. Maximum number of
drives and capacity varies based on configuration model and drive
types.
Reliability:
Redundant hot-swappable controllers with vertical port
sharing
Hot-swappable disks and power supplies
Enclosure Monitoring System:
Automatic spare configuration and utilization
SMART
Automatic bad block replacement
Auto-Stat Disk Monitoring System (ADMS) to monitor health of data on
disk drives
Management Interfaces:
Group Manager (GUI & CLI)
SAN Headquarters multi-group performance and event monitoring tool
Virtual Storage Manager vCenter plugin
Serial console
Ability to configure a separate management network
SNMP, telnet, SSH, HTTP, Web (SSL)
Host scripting, including Windows PowerShell
Multi-administrator support
Security:
CHAP authentication
Access control for iSCSI as well as new Access Control Policies
Access control for management interfaces including Active Directory,
LDAP, or RADIUS support
Notification Methods: SAN
Headquarters alerting, including Dell SupportAssist,SNMP traps,
e-mail, syslog
Environmental Operating Conditions:
Temperature range: 5¢X to 40¢XC (41¢X to 104¢XF)
Storage temperature: ¡V40¢X to 65¢XC (¡V40¢X to 149¢XF)
Altitude: For altitudes above 2950 feet, the maximum operating
temperature is derated 1ºF/550 ft.
Operating Relative humidity: 20% to 80% (noncondensing) with a
maximum humidity gradation of 10% per hour
Operational shock: Half-sine shock 31G +/- 5% with a pulse duration
of 2.6ms +/- 10% in operational orientations only
Operating Vibration: 0.26 Grms (5 to 350 Hz) for 5 minutes in
operational orientations
Acoustics Category 4: <=7.2 bels at 23C +/- 2C
Air Quality: Airborne contaminant level of G1 or lower as defined by
ISA-S71.04-1985
Rack Support: ReadyRails™
II static rails for tool-less mounting in 4-post racks with square
or unthreaded round holes or tooled mounting in 4-post threaded-hole
racks
Regulatory information:
Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment
¡@
ENERGY STAR®
¡@
The Dell PS6210 series arrays have earned the ENERGY
STAR Data Center Storage designation. Click
Here to
learn more about the ENERGY STAR Storage 1.0
designation. |
|
* RAID 5 is also available for non-production data, but is generally
not recommended; RAID 50 is similarly not recommended for production
data on drives larger than 2TB.
** Actual unit & packaged weights will vary slightly by on drive
type and packaging, and over time.
|
¡D¥»¤å¥óªº¸ê°TY¦³×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ùY¦³»~¡A¥Hì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨äì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C
º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á!
ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶WÈÀu´fªºDELL - Dell EqualLogic PS6210 - Àx¦s³]³Æ/³Æ¥÷¤è®×
,³Ì¦nªºDELL - Dell EqualLogic PS6210±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
|
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§ÚÌ·|¬°±z¦Vì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú̳£¥i¼u©Ê°t¦X±zªº»Ýn³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G
1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901 |
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»¶ÁʶR¸ß»ù§ÚÌ·|¥ß§Y»P±zÁpô! |
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw |
|
¥I´Ú¤è¦¡¡G¦p«È¤á¬°º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C |
¶Ç¯uq³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨qÁʵ{§Ç¡A§ÚÌ·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{q³æ¡C |
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú̦¬¨ì±zq³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C |
°e³f¤è¦¡¡G(1) ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C |
°e³f½d³ò¡G¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±zt¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C |
°â«áªA°È¡GY²£«~¥»¨·å²«©Î¹B°e¹Lµ{¾ÉP·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C |
«O©T¬Fµ¦¡G ¹ê»Ú¥Hì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C |
¤O±ô¸ê°T ServerBank Inc. ²¤¶
¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G
»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶Û¡B¥xÆWªFªÛ¡B¥xÆW^¸â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B
¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B
ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B
¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B
Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B
¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B
´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B¸ºÐ¼s¼½¡B·¼é°Û¤ù¡B®É³ø©P¥Z¡B
±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B
²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡Bì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°
¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B
ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B
¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B
¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤±]±¶¹B¡B¥xÆW´¼¼z¥d¡B
¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½^¡B¿ßÀYÆN
©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B
x¤è¡G ªÅx¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B
|
|
|
|
|
|
|
¡@ |
|