­º­¶> Àx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦C°t¥ó

>>ÂsÄý©Ò¦³DELLÀx¦s³]³Æ/³Æ¥÷¤è®×>

DELL
Dell SC8000

«¬¸¹¡GSC8000


DELLSC8000


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºDELL - SC8000 - Àx¦s³]³Æ/³Æ¥÷¤è®×>
³Ì¦nªºDELL - Dell SC8000±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦C°t¥ó Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óDELL¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§DELL²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§DELL­ì¼t°t¥ó


¡@

¡@

¡@


DELL
Dell SC8000 - ServerBank¸ê°T±ÄÁʺô
SC8000
Àx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦C°t¥ó


¡@
²£«~³W®æ
·s¼Wºô­¶1

§Þ³N¯SÂI

  • ²£«~§@·~¨t²Î
    Storage Center 6.1 ©Î§ó·sª©¥»

    °}¦C²ÕºA
    ¥þ§Ö°{°O¾ÐÅé¡B²V¦X¦¡©ÎµwºÐ°}¦C
    ¦Û°Ê¤À¼h³B²z¤è¦¡
    ¨Ì¾Ú§Y®É¸ê®Æ¨Ï¥Î±¡ªp¶i¦æ­ì«h¦¡¾E²¾¡A¥i¦Û­qªº 512KB-4MB ¤À­¶¤j¤p

    ¦Û°Ê¤À¼h³B²zµ²ºc

    Á`­p³Ì¦h 3 ­Ó¥D­n¶¥¼h (¥H´CÅ鬰°ò¦)¡A³Ì¦h 2 ­Ó©TºAµwºÐ¶¥¼h (¼g¤J»PŪ¨ú±K¶°«¬©TºAµwºÐ)

    ¤À¼h«È»s¤Æ
    ¨Ï¥ÎªÌ©w¸q³]©wÀÉ¡B´£¨Ñ±NºÏºÐ°Ï¡u©T©w¡v¨ì¥ô¦ó¶¥¼hªº¿ï¶µ

    RAID ¤ä´©
    ¤ä´© RAID 0¡B1¡B5¡B6¡BRAID 10 ¤Î RAID 10 DM (ÂùÃè¹³)¡F³æ¤@°}¦C¥i¦s¦b¥ô¦ó RAID ¼h¯Åªº²Õ¦X

    RAID ¤À¼h

    ¦b¦P­Ó¶¥¼h¦Û°ÊÀH»Ý¤À°t¨Ã°ÊºA­«·sµ¥¶q¤À°t¦h­Ó RAID ¼h¯Å¡FµL»Ý¹w¥ý°t¸m RAID ¸s²Õ

    ºë²ÀH»Ý¤À°t

    ©Ò¦³ºÏºÐ°Ï¬Ò¹w³]¬°±Ò¥Îª¬ºA¡A¨Ã¥i·f°t©Ò¦³¥\¯à¥H§¹¾ã®Ä¯à¹B§@

    ºë²§Ö·Ó
    ¶È­­°O¿ýÅܧó¡A§Ö·Ó·|¦Û°Ê¾E²¾¦Ü¦¨¥»¸û§CªºÀx¦s¸Ë¸m

    ´¼¼z«¬­«½Æ¸ê®Æ§R°£1 »PÀ£ÁY¥\¯à

    ¥i©ó©TºAµwºÐ¤Î/©ÎµwºÐ¤À¼hªº¨C­ÓºÏºÐ°Ï´£¨Ñ¥i¿ï¾Ü¿ï¶µ
    ¦P®É´£¨Ñ¶È­­À£ÁY¥\¯àªº¿ï¶µ

    ¼Ð·Ç½Æ»s
    ¥i³z¹L FC ©Î iSCSI ¶i¦æ¦P¨B/«D¦P¨B½Æ»s

    ¦h°}¦C¨t²Î¦P·ù
    Live Migrate (ÀHªþ¦b°ò¦²£«~¤¤) ¥i¦b°}¦C¤§¶¡¶i¦æ¥D¾÷³q³z¸ê®Æ²¾°Ê§@·~2
    Volume Advisor ·|«ùÄòºÊ±±¦P·ù¡AµM«á¨Ì¾Ú«È»s¤Æ®e¶q©Î®Ä¯à­t¸ü¥­¿Å­ì«h¡A´£¨Ñ³Ì¨Îªº¸ê®Æ¦ì¸m«Øij
    Dell Storage Manager ¯à´£¨Ñ¸ê®Æ¤¤¤ß¼h¯ÅªºÆ[ÂI»P±±¨î¥\¯à3

    ¯à»P PS ¨t¦C°}¦C¨Ã¦s3

    ¥iÂù¦V½Æ»s
    ³z¹L³æ¤@¤¶­±ºÞ²z¤é±`¨Æ°È
    ºë²¶×¤J¡G±q PS ¨t¦C°}¦C¾E²¾¸ê®Æ®É¡A¥i¸`¬ÙªÅ¶¡¤S¤£·|¤¤Â_§@·~¶i¦æ

    ·~°È³sÄò©Ê

    Live Volume ¦Û°Ê®e¿ù²¾Âà¡B¦Û°Ê­×´_
    VMware Metro Stretch Cluster ¤ä´©
    Microsoft® Azure Site Recovery

    À³¥Îµ{¦¡¸ê®Æ«OÅ@
    ¦b Oracle¡BMicrosoft ©Î VMware Àô¹Ò¤¤¡AÁÙ­ì°}¦C¸Ìªº¥D¾÷ºÝ¸ê®Æ

    ¶¢¸m¸ê®Æ¥[±K
    ±Ä¥Î©TºAµwºÐ©Î¤@¯ëµwºÐ®æ¦¡ªº¦Û§Ú¥[±KµwºÐ (SED)
    ±Ä¥Î AES-256 §Þ³Nªº¥þºÏºÐ¥[±K (FCE)
    ºÏºÐ¾÷³q¹L FIPS 140-2 Level 2 »{ÃÒ
    ´£¨Ñª÷Æ_ºÞ²z¦øªA¾¹ (KMS) ¿ï¶µ¡A¥H§Q¶i¦æ FIPS 140-2 Level 1¡B2 »P 3 »{ÃÒ

    ¤ä´©¥~³¡ª÷Æ_ºÞ²zµ{¦¡

    Gemalto ªº SafeNet KeySecure k460¡BSafeNet KeySecure k250¡BSafeNet KeySecure k150v
    Thales EMS 200
    ¡@

ºÞ²z

  • ºÞ²z¤¶­±
    Dell Storage Manager («e¨­¬° Enterprise Manager)
    ¥i³z¹L³æ¤@¤¶­±¶i¦æ¦h°}¦C¡B¦h¯¸¥x»P¸ó¥­¥xºÞ²z4

    ¤u§@­t²üºÞ²z
    QoS1
    VVOLs1

    «ü¥OÀɽs¼g¤ä´©
    SMI-S
    Microsoft PowerShell API
    RESTful API

    ¥D¾÷§@·~¨t²Î¤ä´©

    Microsoft® Windows Server®¡BOracle® Solaris¡BHP®-UX¡BOracle Linux¡BIBM® AIX®¡BNovell® NetWare¡BSLES¡BApple¡BHPTru64¡BVMware®¡BCitrix® XenServer®¡BRedHat®

    ¨ó¤O¼t°ÓÀ³¥Îµ{¦¡¾ã¦X
    VMware¡BOracle¡BMicrosoft¡BIBM¡BOpenStack¡BSymantec¡BCommvault¡BFoglight¡BDocker (½Ð°Ñ¾\ SC ¨t¦CºÞ²z³W®æªí¤F¸Ñ¸Ô±¡)

    »{ÃÒ
    VMware Metro Stretch Clusters
    VMware SRM
    IBM VIOS Recognized

    ³ø§i/ĵ¥Ü
    ¤ä´©¨ó§U (­P¹q©²¤W)¡B»·ºÝ¶EÂ_»P®Ä¯àºÊ±±¡B¦Û°Ê¤Æĵ¥Ü¡B³ø§i»P³qª¾¡B¨Ì³¡ªù¤ÀÅu¶O¥Î

ÂX¥R©Ê

  • Àx¦s®e¶q¡G¨C­ÓÂù±±¨î¾¹¨t²Î¥iÂX¥R¦Ü 960 ­ÓºÏºÐ¾÷ (­ì©l®e¶q¥i¹F 3PB)¡F¦P·ù¨t²Î¥iÂX¥R¦Ü§ó¤jªº®e¶q5
    °O¾ÐÅé¡G¨C­ÓÂù±±¨î¾¹¨t²Îªº§Ö¨ú°O¾ÐÅéÁ`¦@¥iÂX¥R¦Ü 128GB¡F¦P·ù¨t²Î¥iÂX¥R¦Ü§ó¤jªº§Ö¨ú°O¾ÐÅé®e¶q5
    2.5¡¨ ºÏºÐ¾÷¡G¨C­Ó SC220 ÂX¥R¾÷Âd¥iÂX¥R¦Ü 24 ­ÓºÏºÐ¾÷
    3.5¡¨ ºÏºÐ¾÷¡G¨C­Ó SC200 ÂX¥R¾÷Âd¥iÂX¥R¦Ü 12 ­ÓºÏºÐ¾÷¡F¨C­Ó SC280 ÂX¥R¾÷Âd¥iÂX¥R¦Ü 84 ­ÓºÏºÐ¾÷
    ¡@

³B²z¾¹

  • ¨C­Ó±±¨î¾¹¨âÁû 2.5GHz 6 ®Ö¤ß Intel™ ³B²z¾¹

³s½u¯à¤O

  • ­Ó§OÂù±±¨î¾¹¨t²Î¡F¦h­Ó¨t²Î¥i¦¨¬°¦P·ùÃö«Y5

    «eºÝ³s½u¯à¤O
    ¥úÅÖ³q¹D (4Gb¡B8Gb¡B16Gb)¡BiSCSI (1Gb¡B10Gb)¡BFCoE (10Gb)
    ¦P¨B¤¶­±¤ä´©

    «eºÝ³s±µ°ð³Ì¤j¼Æ¶q
    ¨C­Ó±±¨î¾¹ 16 ­Ó (¥úÅÖ³q¹D)¡B10 ­Ó (1Gb iSCSI)¡B10 ­Ó (10Gb iSCSI)¡B10 ­Ó (FCoE)¡C³Æµù¡GSC8000 ±±¨î¾¹³Ì¦h¥i¤ä´© 16 ­Ó FC «eºÝ³s±µ°ð¡A¥H¤Î 4 ³s±µ°ð§C¸G«¬ SAS «áºÝ IO ¿ï¶µ¡C

    «áºÝ³s½u¯à¤O
    SAS (6Gb ¤Î 3Gb)¡B¥úÅÖ³q¹D (2Gb¡B4Gb¡B8Gb)

    «áºÝ³s±µ°ð³Ì¤j¼Æ¶q
    ¨C­Ó±±¨î¾¹ 16 ­Ó (¥úÅÖ³q¹D)¡B20 ­Ó (SAS)¡Fª`·N¡GSATA ³s±µ°ð¡BFC ¤Î SATA ¾÷Âd¨Ã¥¼³s±µ¦Ü FC8 IO ¥d¡C

    ¥úÅÖ³q¹D¤Î SATA ÂX¥R¾÷Âd³z¹L¥úÅÖ³q¹D IO ÂX¥R¥d³s±µ¦Ü SC8000
    ¡@

Àx¦s

  • ºÏºÐ¾÷¤¶­±
    SAS »P NL-SAS ºÏºÐ¾÷¡C¤]¥i¥H¦V¤U¬Û®e²{¦³ªº Compellent ¥úÅÖ³q¹D¤Î SATA ºÏºÐ¾÷¡C
    ¬Û¦P¨t²Î¤¤¥i¥H²V¦X¤£¦PªººÏºÐ¾÷Ãþ«¬¡B¶Ç¿é³t²v¤Î±ÛÂà³t«×

¾÷½c

  • Àx¦s±±¨î¾¹
    ¾÷¬[¤j¤p¡G2U
    °ª«×¡G87.3 ¤½Âç (3.44 ¦T)
    ¼e«×¡G482.4 ¤½Âç (18.98 ¦T)¡A§t¾÷¬[ªù­¬
    444 ¤½Âç (17.08 ¦T)¡A¤£§t¾÷¬[ªù­¬
    ²`«×¡G755.8 ¤½Âç (29.75 ¦T)¡A§t¥~®Ø
    ­«¶q¡G19.73 ¤½¤ç (43.5 ½S)

    ¾÷¬[¤ä´©
    ReadyRails™ II ©T©w¦¡¾É­y¤£»Ý¨Ï¥Î¤u¨ã¡A§Y¥i±¾¸ü©ó¤è¤Õ©ÎµLÁ³¯¾¶ê¤Õªº 4 ¬W¦¡¾÷¬[¡A©Î¥i¨Ï¥Î¤u¨ã±¾¸ü©ó 4 ¬W¦¡Á³¯¾¤Õ¾÷¬[
    ¡@

Àô¹Ò§@·~ª¬ªp

  • SC8000 ±±¨î¾¹¡G
    ¹q·½¡GÂù³Æ´© 80 Plus® ¥Õª÷¯Å»{ÃÒ 750W ¹q·½¨ÑÀ³¾¹
    ³Ì¤j¯Ó¹q¶q¡G425W

    ´²¼ö (³Ì¤j­È)¡G¨C¤p®É 1,450 BTU

    §@·~·Å«×¡GµØ¤ó 50 ¦Ü 95 «× (Äá¤ó 10 ¦Ü 35 «×)
    «D§@·~·Å«×¡GµØ¤ó -40 ¦Ü 149 «× (Äá¤ó -40 ¦Ü 65 «×)
    §@·~Àã«×½d³ò (µL§N¾®)¡G§@·~¤¤¡A20% ¦Ü 80%
    «D§@·~Àã«× (µL§N¾®)¡G5% ¦Ü 95%
    ¶i®ð¤fÃþ«¬¡GNEMA 5-15/CS22.2¡Bn¢X42
    ¡@

±Æ©ñ/¦w¥þ

  • ±±¨î¾¹
    FCC Class A¡FEN55022 Class A¡FEN 61000-3-2/-3-3¡FCISPR 22 Class A¡FEN55024/CISPR 24¡F(EN 61000-4-2¡BEN 61000-4-3¡BEN 61000-4-4¡BEN 61000-4-5¡BEN 61000-4-6¡BEN 61000-4-8¡BEN 61000-4-11)¡FEN60950/IEC 60950 UL »{ÃÒ (¬ü°ê)¡BCUL »{ÃÒ (¥[®³¤j)¡BTUV »{ÃÒ (¼w°ê)¡BCE ¼Ð°O (¼Ú¬w)

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºDELL - SC8000 - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºDELL - Dell SC8000±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 NASºô¸ôÀx¦sÀɮצøªA¾¹
 ServerBank±ÀÂ˾÷ºØ
 ®à¤W«¬
 ¾÷¬[¦¡
 ª½¥ß¦¡
 ºÏºÐ°}¦C°t¥ó
 ¦Û°Ê¥úºÐ«þ¨©¾÷
 ¥~±µ¦¡µwºÐ
 ºÏ±a¾÷
 SDLT
 DLT
 LTO 1/2/3/4
 Ultrium I
 Ultrium II
 SAIT
 AIT
 AIT Turbo
 DAT
 DDS
 ºÏ±a´«±a¾÷Autoloader
 iSCSI¸Ñ¨M¤è®×
 iSCSIºÏºÐ°}¦C
 iSCSI¾ô±µ¾¹
 ºÏºÐ°}¦CRAID
 ServerBank±ÀÂ˾÷ºØ
 iSCSI
 iSCSI to SAS
 SATA
 SCSI-to-SCSI
 SCSI-to-IDE
 SCSI-to-SATA
 Fibre-to-SCSI
 Fibre-to-IDE
 Fibre-to-SATA
 Fibre-to-Fibre
 Fibre to SAS
 USB-to-IDE
 SATA-to-SATA
 SATA-to-IDE
 SAS
 IDE-to-IDE
 1394-to-IDE
 JBOD
 ºÏºÐ°}¦CÂd
 1394B-to-SATAII
 1394B-to PATA
 °ïÅ|¦¡Àx¦s¥~±µ²°
 SAS-to-SATA
 SAS-to-SAS
 SCSI-to-SAS
 PCIE
 USB
 IDE
 SAN¸Ñ¨M¤è®×
 ¥úÅÖ³q¹D¥æ´«¾¹
 ¥úÅÖ³q¹D¤¶­±¥d
 SAN Storage
 SAN Software
 ¥úÅÖ³q¹D¾ô±µ¾¹
 ¾É¦V¾¹director
 ¥úÅÖ¼Ò²Õ
 Àx¦sºÞ²z³nÅé
 ºÏ±aÂd
 ºÏ±a
 ¦Û°Ê´«¤ù¥úºÐ
 ÂÅ¥ú¥úºÐÂd
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > Àx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦C°t¥ó


DELLSC8000

Dell SC8000


¼tµP¡GDELL      >>ÂsÄýDELL¥þ³¡²£«~
«¬¸¹¡GSC8000



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºDELL - SC8000 - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºDELL - Dell SC8000±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦C°t¥ó Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óDELL¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§DELL²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§DELL­ì¼t°t¥ó


¡@

¡@

¡@


DELL
Dell SC8000 - ServerBank¸ê°T±ÄÁʺô
SC8000
Àx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦C°t¥ó


¡@
²£«~³W®æ
·s¼Wºô­¶1

§Þ³N¯SÂI

  • ²£«~§@·~¨t²Î
    Storage Center 6.1 ©Î§ó·sª©¥»

    °}¦C²ÕºA
    ¥þ§Ö°{°O¾ÐÅé¡B²V¦X¦¡©ÎµwºÐ°}¦C
    ¦Û°Ê¤À¼h³B²z¤è¦¡
    ¨Ì¾Ú§Y®É¸ê®Æ¨Ï¥Î±¡ªp¶i¦æ­ì«h¦¡¾E²¾¡A¥i¦Û­qªº 512KB-4MB ¤À­¶¤j¤p

    ¦Û°Ê¤À¼h³B²zµ²ºc

    Á`­p³Ì¦h 3 ­Ó¥D­n¶¥¼h (¥H´CÅ鬰°ò¦)¡A³Ì¦h 2 ­Ó©TºAµwºÐ¶¥¼h (¼g¤J»PŪ¨ú±K¶°«¬©TºAµwºÐ)

    ¤À¼h«È»s¤Æ
    ¨Ï¥ÎªÌ©w¸q³]©wÀÉ¡B´£¨Ñ±NºÏºÐ°Ï¡u©T©w¡v¨ì¥ô¦ó¶¥¼hªº¿ï¶µ

    RAID ¤ä´©
    ¤ä´© RAID 0¡B1¡B5¡B6¡BRAID 10 ¤Î RAID 10 DM (ÂùÃè¹³)¡F³æ¤@°}¦C¥i¦s¦b¥ô¦ó RAID ¼h¯Åªº²Õ¦X

    RAID ¤À¼h

    ¦b¦P­Ó¶¥¼h¦Û°ÊÀH»Ý¤À°t¨Ã°ÊºA­«·sµ¥¶q¤À°t¦h­Ó RAID ¼h¯Å¡FµL»Ý¹w¥ý°t¸m RAID ¸s²Õ

    ºë²ÀH»Ý¤À°t

    ©Ò¦³ºÏºÐ°Ï¬Ò¹w³]¬°±Ò¥Îª¬ºA¡A¨Ã¥i·f°t©Ò¦³¥\¯à¥H§¹¾ã®Ä¯à¹B§@

    ºë²§Ö·Ó
    ¶È­­°O¿ýÅܧó¡A§Ö·Ó·|¦Û°Ê¾E²¾¦Ü¦¨¥»¸û§CªºÀx¦s¸Ë¸m

    ´¼¼z«¬­«½Æ¸ê®Æ§R°£1 »PÀ£ÁY¥\¯à

    ¥i©ó©TºAµwºÐ¤Î/©ÎµwºÐ¤À¼hªº¨C­ÓºÏºÐ°Ï´£¨Ñ¥i¿ï¾Ü¿ï¶µ
    ¦P®É´£¨Ñ¶È­­À£ÁY¥\¯àªº¿ï¶µ

    ¼Ð·Ç½Æ»s
    ¥i³z¹L FC ©Î iSCSI ¶i¦æ¦P¨B/«D¦P¨B½Æ»s

    ¦h°}¦C¨t²Î¦P·ù
    Live Migrate (ÀHªþ¦b°ò¦²£«~¤¤) ¥i¦b°}¦C¤§¶¡¶i¦æ¥D¾÷³q³z¸ê®Æ²¾°Ê§@·~2
    Volume Advisor ·|«ùÄòºÊ±±¦P·ù¡AµM«á¨Ì¾Ú«È»s¤Æ®e¶q©Î®Ä¯à­t¸ü¥­¿Å­ì«h¡A´£¨Ñ³Ì¨Îªº¸ê®Æ¦ì¸m«Øij
    Dell Storage Manager ¯à´£¨Ñ¸ê®Æ¤¤¤ß¼h¯ÅªºÆ[ÂI»P±±¨î¥\¯à3

    ¯à»P PS ¨t¦C°}¦C¨Ã¦s3

    ¥iÂù¦V½Æ»s
    ³z¹L³æ¤@¤¶­±ºÞ²z¤é±`¨Æ°È
    ºë²¶×¤J¡G±q PS ¨t¦C°}¦C¾E²¾¸ê®Æ®É¡A¥i¸`¬ÙªÅ¶¡¤S¤£·|¤¤Â_§@·~¶i¦æ

    ·~°È³sÄò©Ê

    Live Volume ¦Û°Ê®e¿ù²¾Âà¡B¦Û°Ê­×´_
    VMware Metro Stretch Cluster ¤ä´©
    Microsoft® Azure Site Recovery

    À³¥Îµ{¦¡¸ê®Æ«OÅ@
    ¦b Oracle¡BMicrosoft ©Î VMware Àô¹Ò¤¤¡AÁÙ­ì°}¦C¸Ìªº¥D¾÷ºÝ¸ê®Æ

    ¶¢¸m¸ê®Æ¥[±K
    ±Ä¥Î©TºAµwºÐ©Î¤@¯ëµwºÐ®æ¦¡ªº¦Û§Ú¥[±KµwºÐ (SED)
    ±Ä¥Î AES-256 §Þ³Nªº¥þºÏºÐ¥[±K (FCE)
    ºÏºÐ¾÷³q¹L FIPS 140-2 Level 2 »{ÃÒ
    ´£¨Ñª÷Æ_ºÞ²z¦øªA¾¹ (KMS) ¿ï¶µ¡A¥H§Q¶i¦æ FIPS 140-2 Level 1¡B2 »P 3 »{ÃÒ

    ¤ä´©¥~³¡ª÷Æ_ºÞ²zµ{¦¡

    Gemalto ªº SafeNet KeySecure k460¡BSafeNet KeySecure k250¡BSafeNet KeySecure k150v
    Thales EMS 200
    ¡@

ºÞ²z

  • ºÞ²z¤¶­±
    Dell Storage Manager («e¨­¬° Enterprise Manager)
    ¥i³z¹L³æ¤@¤¶­±¶i¦æ¦h°}¦C¡B¦h¯¸¥x»P¸ó¥­¥xºÞ²z4

    ¤u§@­t²üºÞ²z
    QoS1
    VVOLs1

    «ü¥OÀɽs¼g¤ä´©
    SMI-S
    Microsoft PowerShell API
    RESTful API

    ¥D¾÷§@·~¨t²Î¤ä´©

    Microsoft® Windows Server®¡BOracle® Solaris¡BHP®-UX¡BOracle Linux¡BIBM® AIX®¡BNovell® NetWare¡BSLES¡BApple¡BHPTru64¡BVMware®¡BCitrix® XenServer®¡BRedHat®

    ¨ó¤O¼t°ÓÀ³¥Îµ{¦¡¾ã¦X
    VMware¡BOracle¡BMicrosoft¡BIBM¡BOpenStack¡BSymantec¡BCommvault¡BFoglight¡BDocker (½Ð°Ñ¾\ SC ¨t¦CºÞ²z³W®æªí¤F¸Ñ¸Ô±¡)

    »{ÃÒ
    VMware Metro Stretch Clusters
    VMware SRM
    IBM VIOS Recognized

    ³ø§i/ĵ¥Ü
    ¤ä´©¨ó§U (­P¹q©²¤W)¡B»·ºÝ¶EÂ_»P®Ä¯àºÊ±±¡B¦Û°Ê¤Æĵ¥Ü¡B³ø§i»P³qª¾¡B¨Ì³¡ªù¤ÀÅu¶O¥Î

ÂX¥R©Ê

  • Àx¦s®e¶q¡G¨C­ÓÂù±±¨î¾¹¨t²Î¥iÂX¥R¦Ü 960 ­ÓºÏºÐ¾÷ (­ì©l®e¶q¥i¹F 3PB)¡F¦P·ù¨t²Î¥iÂX¥R¦Ü§ó¤jªº®e¶q5
    °O¾ÐÅé¡G¨C­ÓÂù±±¨î¾¹¨t²Îªº§Ö¨ú°O¾ÐÅéÁ`¦@¥iÂX¥R¦Ü 128GB¡F¦P·ù¨t²Î¥iÂX¥R¦Ü§ó¤jªº§Ö¨ú°O¾ÐÅé®e¶q5
    2.5¡¨ ºÏºÐ¾÷¡G¨C­Ó SC220 ÂX¥R¾÷Âd¥iÂX¥R¦Ü 24 ­ÓºÏºÐ¾÷
    3.5¡¨ ºÏºÐ¾÷¡G¨C­Ó SC200 ÂX¥R¾÷Âd¥iÂX¥R¦Ü 12 ­ÓºÏºÐ¾÷¡F¨C­Ó SC280 ÂX¥R¾÷Âd¥iÂX¥R¦Ü 84 ­ÓºÏºÐ¾÷
    ¡@

³B²z¾¹

  • ¨C­Ó±±¨î¾¹¨âÁû 2.5GHz 6 ®Ö¤ß Intel™ ³B²z¾¹

³s½u¯à¤O

  • ­Ó§OÂù±±¨î¾¹¨t²Î¡F¦h­Ó¨t²Î¥i¦¨¬°¦P·ùÃö«Y5

    «eºÝ³s½u¯à¤O
    ¥úÅÖ³q¹D (4Gb¡B8Gb¡B16Gb)¡BiSCSI (1Gb¡B10Gb)¡BFCoE (10Gb)
    ¦P¨B¤¶­±¤ä´©

    «eºÝ³s±µ°ð³Ì¤j¼Æ¶q
    ¨C­Ó±±¨î¾¹ 16 ­Ó (¥úÅÖ³q¹D)¡B10 ­Ó (1Gb iSCSI)¡B10 ­Ó (10Gb iSCSI)¡B10 ­Ó (FCoE)¡C³Æµù¡GSC8000 ±±¨î¾¹³Ì¦h¥i¤ä´© 16 ­Ó FC «eºÝ³s±µ°ð¡A¥H¤Î 4 ³s±µ°ð§C¸G«¬ SAS «áºÝ IO ¿ï¶µ¡C

    «áºÝ³s½u¯à¤O
    SAS (6Gb ¤Î 3Gb)¡B¥úÅÖ³q¹D (2Gb¡B4Gb¡B8Gb)

    «áºÝ³s±µ°ð³Ì¤j¼Æ¶q
    ¨C­Ó±±¨î¾¹ 16 ­Ó (¥úÅÖ³q¹D)¡B20 ­Ó (SAS)¡Fª`·N¡GSATA ³s±µ°ð¡BFC ¤Î SATA ¾÷Âd¨Ã¥¼³s±µ¦Ü FC8 IO ¥d¡C

    ¥úÅÖ³q¹D¤Î SATA ÂX¥R¾÷Âd³z¹L¥úÅÖ³q¹D IO ÂX¥R¥d³s±µ¦Ü SC8000
    ¡@

Àx¦s

  • ºÏºÐ¾÷¤¶­±
    SAS »P NL-SAS ºÏºÐ¾÷¡C¤]¥i¥H¦V¤U¬Û®e²{¦³ªº Compellent ¥úÅÖ³q¹D¤Î SATA ºÏºÐ¾÷¡C
    ¬Û¦P¨t²Î¤¤¥i¥H²V¦X¤£¦PªººÏºÐ¾÷Ãþ«¬¡B¶Ç¿é³t²v¤Î±ÛÂà³t«×

¾÷½c

  • Àx¦s±±¨î¾¹
    ¾÷¬[¤j¤p¡G2U
    °ª«×¡G87.3 ¤½Âç (3.44 ¦T)
    ¼e«×¡G482.4 ¤½Âç (18.98 ¦T)¡A§t¾÷¬[ªù­¬
    444 ¤½Âç (17.08 ¦T)¡A¤£§t¾÷¬[ªù­¬
    ²`«×¡G755.8 ¤½Âç (29.75 ¦T)¡A§t¥~®Ø
    ­«¶q¡G19.73 ¤½¤ç (43.5 ½S)

    ¾÷¬[¤ä´©
    ReadyRails™ II ©T©w¦¡¾É­y¤£»Ý¨Ï¥Î¤u¨ã¡A§Y¥i±¾¸ü©ó¤è¤Õ©ÎµLÁ³¯¾¶ê¤Õªº 4 ¬W¦¡¾÷¬[¡A©Î¥i¨Ï¥Î¤u¨ã±¾¸ü©ó 4 ¬W¦¡Á³¯¾¤Õ¾÷¬[
    ¡@

Àô¹Ò§@·~ª¬ªp

  • SC8000 ±±¨î¾¹¡G
    ¹q·½¡GÂù³Æ´© 80 Plus® ¥Õª÷¯Å»{ÃÒ 750W ¹q·½¨ÑÀ³¾¹
    ³Ì¤j¯Ó¹q¶q¡G425W

    ´²¼ö (³Ì¤j­È)¡G¨C¤p®É 1,450 BTU

    §@·~·Å«×¡GµØ¤ó 50 ¦Ü 95 «× (Äá¤ó 10 ¦Ü 35 «×)
    «D§@·~·Å«×¡GµØ¤ó -40 ¦Ü 149 «× (Äá¤ó -40 ¦Ü 65 «×)
    §@·~Àã«×½d³ò (µL§N¾®)¡G§@·~¤¤¡A20% ¦Ü 80%
    «D§@·~Àã«× (µL§N¾®)¡G5% ¦Ü 95%
    ¶i®ð¤fÃþ«¬¡GNEMA 5-15/CS22.2¡Bn¢X42
    ¡@

±Æ©ñ/¦w¥þ

  • ±±¨î¾¹
    FCC Class A¡FEN55022 Class A¡FEN 61000-3-2/-3-3¡FCISPR 22 Class A¡FEN55024/CISPR 24¡F(EN 61000-4-2¡BEN 61000-4-3¡BEN 61000-4-4¡BEN 61000-4-5¡BEN 61000-4-6¡BEN 61000-4-8¡BEN 61000-4-11)¡FEN60950/IEC 60950 UL »{ÃÒ (¬ü°ê)¡BCUL »{ÃÒ (¥[®³¤j)¡BTUV »{ÃÒ (¼w°ê)¡BCE ¼Ð°O (¼Ú¬w)

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºDELL - SC8000 - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºDELL - Dell SC8000±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@