­º­¶> Àx¦s³]³Æ/³Æ¥÷¤è®×>iSCSI¸Ñ¨M¤è®×>iSCSIºÏºÐ°}¦C

>>ÂsÄý©Ò¦³DELLÀx¦s³]³Æ/³Æ¥÷¤è®×>

DELL
DELL EqualLogic PS6210 Series Arrays

«¬¸¹¡GEqualLogic PS6210 Series Arrays


DELLEqualLogic PS6210 Series Arrays


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºDELL - EqualLogic PS6210 Series Arrays - Àx¦s³]³Æ/³Æ¥÷¤è®×>
³Ì¦nªºDELL - DELL EqualLogic PS6210 Series Arrays±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®×>iSCSI¸Ñ¨M¤è®×>iSCSIºÏºÐ°}¦C Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óDELL¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§DELL²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§DELL­ì¼t°t¥ó


¡@

¡@

¡@


DELL
DELL EqualLogic PS6210 Series Arrays - ServerBank¸ê°T±ÄÁʺô
EqualLogic PS6210 Series Arrays
Àx¦s³]³Æ/³Æ¥÷¤è®×>iSCSI¸Ñ¨M¤è®×>iSCSIºÏºÐ°}¦C


¡@
²£«~³W®æ
¡@
  PS6210E PS6210X PS6210XV PS6210S PS6210XS
Hard Disk Drives  24 hot-pluggable 3.5" 7.2K RPM NL-SAS drives  24 hot-pluggable 2.5" 10K RPM SAS drives 24 hot-pluggable 2.5" 15K RPM SAS drives 24 hot-pluggable 2.5" SSDs 7 hot-pluggable 2.5" SSDs and 17 hot-pluggable 2.5" 10K RPM SAS drives
Drive Capacities
¡@
2TB, 3TB, 4TB, 6TB 600GB, 900GB, and 1.2TB 300GB, 600GB 400GB, 800GB, 1.6TB Combines 400GB or 800GB SSDs and 600GB or 1.2TB 10K RPM SAS drives
Self Encrypting Drives (SED) 4TB 7.2K RPM NL-SAS drives  1.2TB 10K RPM SAS drives  600GB 15K RPM SAS drives   N/A N/A 
System Capacities  Up to 144TB (up to 2.3PB with 16 arrays) Up to 28.8TB (up to 460.8TB with 16 arrays) Up to 14.4TB (up to 230.4TB with 16 arrays) Up to 38.4TB (up to 614.4TB with 16 arrays) Up to 26TB (up to 416TB with 16 arrays)
RAID Support RAID 6, RAID 10 and RAID 50 (for 2 TB drives)* RAID 6, RAID 10 and RAID 50* RAID 6, RAID 10 and RAID 50* RAID 6, RAID 10 and RAID 50* Accelerated RAID 6   
Power AC voltage: 100-240 VAC ¡Ó10% single phase 1080W (max, total), +5V up to 155W; +12V up to 924W;+5Vsb up to 10W

Frequency: 50/60 Hz

Power factor: 0.98 (minimum)

Power supplies: Dual, optional dual 1080W DC-DC
AC voltage: 100-240 VAC ¡Ó10% single phase, 700 W (max, total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W

Frequency: 50/60 Hz

Power factor: 0.98 (minimum)

Power supplies: Dual, optional dual 700W DC-DC
AC voltage: 100-240 VAC ¡Ó10% single phase 700 W (max, total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W

Frequency: 50/60 Hz

Power factor: 0.98 (minimum)

Power supplies: Dual, optional dual 700W DC-DC 
AC voltage: 100-240 VAC ¡Ó10% single phase, 700 W (max, total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W

Frequency: 50/60 Hz

Power factor: 0.98 (minimum)

Power supplies: Dual, optional dual 700W DC-DC
AC voltage: 100-240 VAC ¡Ó10% single phase, 700 W (max, total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W

Frequency: 50/60 Hz

Power factor: 0.98 (minimum)

Power supplies: Dual, optional dual 700W DC-DC   
OS Supported Microsoft Windows Server® including Hyper-V®
VMware® ESX Server™
Red Hat® Enterprise Linux® (RHEL)
SUSE® Enterprise Linux® (SLES)
Oracle® Linux®
Citrix® XenServer®


¡@
For a complete list of supported OS versions including software initiators, NICs/CNAs & HBAs, please see the Dell Storage Compatibility Matrix: http://en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/20438558.
¡@
Physical
¡@
Height: 4U / 175 mm (6.87 inches)
Width: 446 mm (17.57 inches)
Depth: 580 mm (22.83 inches)
Weight: 47.1 kg (103.8 lb)**
Height: 2U / 87 mm (3.42 inches)
Width: 446 mm (17.57 inches)
Depth: 546 mm (21.50 inches)
Weight: 26.4 kg (58.3 lb)**
Height: 2U / 87 mm (3.42 inches)
Width: 446 mm (17.57 inches)
Depth: 546 mm (21.50 inches)
Weight: 26.4 kg (58.3 lb)**
Height: 2U / 87 mm (3.42 inches)
Width: 446 mm (17.57 inches)
Depth: 546 mm (21.50 inches)
Weight: 26.4 kg (58.3 lb)**
Height: 2U / 87 mm (3.42 inches)
Width: 446 mm (17.57 inches)
Depth: 546 mm (21.50 inches)
Weight: 26.4 kg (58.3 lb)**
Packaged physical: Length: 905 mm (35.63 inches) Width: 607 mm (23.88 inches) Depth: 521 mm (20.50 inches)
Packaged weight: 66.0 kg (145 lbs)**
Packaged physical: Length: 851 mm (33.50 inches) Width: 616 mm (24.25 inches) Depth: 508 mm (20.00 inches)
Packaged weight: 36.0 kg (79.3 lbs)**
Packaged physical: Length: 851 mm (33.50 inches) Width: 616 mm (24.25 inches) Depth: 508 mm (20.00 inches)
Packaged weight: 36.0 kg (79.3 lbs)**
Packaged physical: Length: 851 mm (33.50 inches) Width: 616 mm (24.25 inches) Depth: 508 mm (20.00 inches)
Packaged weight: 36.0 kg (79.3 lbs)**
Packaged physical: Length: 851 mm (33.50 inches) Width: 616 mm (24.25 inches) Depth: 508 mm (20.00 inches)
Packaged weight: 36.0 kg (79.3 lbs)**

¡@


The following specifications apply to all EqualLogic PS6210 series models:

Storage Controllers: Dual controllers with 16GB non-volatile memory per controller

Network Interfaces: Management network: One 100BASE-TX per controller

Interface ports: Two 10GBASE-T with RJ45 and two 10GbE SFP+ for fibre or twin-ax copper cabling

Volumes: Up to 1,024

Snapshots: 512 per volume/up to 10,000 total per group

Volume connections per PS series pool/group: Up to 1024/4096

Host Protocol: Any standards-compliant iSCSI initiator

TCP Network Support: IPv4, IPv6 compliant. USGv6 certified.

Expansion Option: Can be combined with other PS Series arrays in the same SAN group online; maximum of 16 total arrays per group that can support a maximum of 384 drives and up to 1.536PB with the PS6210 Series. With multigenerational capabilities, you can support up to 10 cross-generation types of controllers with multiple network configurations and drive types in a new or existing PS Series SAN resource pool, all managed by a single interface. Maximum number of drives and capacity varies based on configuration model and drive types. Additionally, PS and SC Series offer common management and cross-platform replication capabilities between arrays, providing PS Series customers the flexibility to add SC Series arrays to their environment, if and when they choose.1

Reliability:
Redundant hot-swappable controllers with vertical port sharing
Hot-swappable disks and power supplies

Enclosure Monitoring System:
Automatic spare configuration and utilization
SMART
Automatic bad block replacement
Auto-Stat Disk Monitoring System (ADMS) to monitor health of data on disk drives

Management Interfaces:
Dell Storage Manager (DSM): Allows you to perform day-to-day tasks across SC and PS Series arrays from a single management interface1
Group Manager (GUI & CLI)
SAN Headquarters multi-group performance and event monitoring tool
Virtual Storage Manager vCenter plugin
Serial console
Ability to configure a separate management network
SNMP, telnet, SSH, HTTP, Web (SSL)
Host scripting, including Windows PowerShell
Multi-administrator support

Security:

CHAP authentication
Access control for iSCSI as well as new Access Control Policies
Access control for management interfaces including Active Directory, LDAP, or RADIUS support

Notification Methods: SAN Headquarters alerting, including Dell SupportAssist,SNMP traps, e-mail, syslog

Environmental Operating Conditions:
Temperature range: 5¢X to 40¢XC (41¢X to 104¢XF)
Storage temperature: ¡V40¢X to 65¢XC (¡V40¢X to 149¢XF)
Altitude: For altitudes above 2950 feet, the maximum operating temperature is derated 1ºF/550 ft.
Operating Relative humidity: 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour
Operational shock: Half-sine shock 31G +/- 5% with a pulse duration of 2.6ms +/- 10% in operational orientations only
Operating Vibration: 0.26 Grms (5 to 350 Hz) for 5 minutes in operational orientations
Acoustics Category 4: <=7.2 bels at 23C +/- 2C
Air Quality: Airborne contaminant level of G1 or lower as defined by ISA-S71.04-1985

Rack Support: ReadyRails™ II static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded-hole racks

Regulatory information:

Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

¡@

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºDELL - EqualLogic PS6210 Series Arrays - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºDELL - DELL EqualLogic PS6210 Series Arrays±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 NASºô¸ôÀx¦sÀɮצøªA¾¹
 ServerBank±ÀÂ˾÷ºØ
 ®à¤W«¬
 ¾÷¬[¦¡
 ª½¥ß¦¡
 ºÏºÐ°}¦C°t¥ó
 ¦Û°Ê¥úºÐ«þ¨©¾÷
 ¥~±µ¦¡µwºÐ
 ºÏ±a¾÷
 SDLT
 DLT
 LTO 1/2/3/4
 Ultrium I
 Ultrium II
 SAIT
 AIT
 AIT Turbo
 DAT
 DDS
 ºÏ±a´«±a¾÷Autoloader
 iSCSI¸Ñ¨M¤è®×
 iSCSIºÏºÐ°}¦C
 iSCSI¾ô±µ¾¹
 ºÏºÐ°}¦CRAID
 ServerBank±ÀÂ˾÷ºØ
 iSCSI
 iSCSI to SAS
 SATA
 SCSI-to-SCSI
 SCSI-to-IDE
 SCSI-to-SATA
 Fibre-to-SCSI
 Fibre-to-IDE
 Fibre-to-SATA
 Fibre-to-Fibre
 Fibre to SAS
 USB-to-IDE
 SATA-to-SATA
 SATA-to-IDE
 SAS
 IDE-to-IDE
 1394-to-IDE
 JBOD
 ºÏºÐ°}¦CÂd
 1394B-to-SATAII
 1394B-to PATA
 °ïÅ|¦¡Àx¦s¥~±µ²°
 SAS-to-SATA
 SAS-to-SAS
 SCSI-to-SAS
 PCIE
 USB
 IDE
 SAN¸Ñ¨M¤è®×
 ¥úÅÖ³q¹D¥æ´«¾¹
 ¥úÅÖ³q¹D¤¶­±¥d
 SAN Storage
 SAN Software
 ¥úÅÖ³q¹D¾ô±µ¾¹
 ¾É¦V¾¹director
 ¥úÅÖ¼Ò²Õ
 Àx¦sºÞ²z³nÅé
 ºÏ±aÂd
 ºÏ±a
 ¦Û°Ê´«¤ù¥úºÐ
 ÂÅ¥ú¥úºÐÂd
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > Àx¦s³]³Æ/³Æ¥÷¤è®×>iSCSI¸Ñ¨M¤è®×>iSCSIºÏºÐ°}¦C


DELLEqualLogic PS6210 Series Arrays

DELL EqualLogic PS6210 Series Arrays


¼tµP¡GDELL      >>ÂsÄýDELL¥þ³¡²£«~
«¬¸¹¡GEqualLogic PS6210 Series Arrays



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºDELL - EqualLogic PS6210 Series Arrays - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºDELL - DELL EqualLogic PS6210 Series Arrays±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®×>iSCSI¸Ñ¨M¤è®×>iSCSIºÏºÐ°}¦C Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óDELL¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§DELL²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§DELL­ì¼t°t¥ó


¡@

¡@

¡@


DELL
DELL EqualLogic PS6210 Series Arrays - ServerBank¸ê°T±ÄÁʺô
EqualLogic PS6210 Series Arrays
Àx¦s³]³Æ/³Æ¥÷¤è®×>iSCSI¸Ñ¨M¤è®×>iSCSIºÏºÐ°}¦C


¡@
²£«~³W®æ
¡@
  PS6210E PS6210X PS6210XV PS6210S PS6210XS
Hard Disk Drives  24 hot-pluggable 3.5" 7.2K RPM NL-SAS drives  24 hot-pluggable 2.5" 10K RPM SAS drives 24 hot-pluggable 2.5" 15K RPM SAS drives 24 hot-pluggable 2.5" SSDs 7 hot-pluggable 2.5" SSDs and 17 hot-pluggable 2.5" 10K RPM SAS drives
Drive Capacities
¡@
2TB, 3TB, 4TB, 6TB 600GB, 900GB, and 1.2TB 300GB, 600GB 400GB, 800GB, 1.6TB Combines 400GB or 800GB SSDs and 600GB or 1.2TB 10K RPM SAS drives
Self Encrypting Drives (SED) 4TB 7.2K RPM NL-SAS drives  1.2TB 10K RPM SAS drives  600GB 15K RPM SAS drives   N/A N/A 
System Capacities  Up to 144TB (up to 2.3PB with 16 arrays) Up to 28.8TB (up to 460.8TB with 16 arrays) Up to 14.4TB (up to 230.4TB with 16 arrays) Up to 38.4TB (up to 614.4TB with 16 arrays) Up to 26TB (up to 416TB with 16 arrays)
RAID Support RAID 6, RAID 10 and RAID 50 (for 2 TB drives)* RAID 6, RAID 10 and RAID 50* RAID 6, RAID 10 and RAID 50* RAID 6, RAID 10 and RAID 50* Accelerated RAID 6   
Power AC voltage: 100-240 VAC ¡Ó10% single phase 1080W (max, total), +5V up to 155W; +12V up to 924W;+5Vsb up to 10W

Frequency: 50/60 Hz

Power factor: 0.98 (minimum)

Power supplies: Dual, optional dual 1080W DC-DC
AC voltage: 100-240 VAC ¡Ó10% single phase, 700 W (max, total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W

Frequency: 50/60 Hz

Power factor: 0.98 (minimum)

Power supplies: Dual, optional dual 700W DC-DC
AC voltage: 100-240 VAC ¡Ó10% single phase 700 W (max, total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W

Frequency: 50/60 Hz

Power factor: 0.98 (minimum)

Power supplies: Dual, optional dual 700W DC-DC 
AC voltage: 100-240 VAC ¡Ó10% single phase, 700 W (max, total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W

Frequency: 50/60 Hz

Power factor: 0.98 (minimum)

Power supplies: Dual, optional dual 700W DC-DC
AC voltage: 100-240 VAC ¡Ó10% single phase, 700 W (max, total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W

Frequency: 50/60 Hz

Power factor: 0.98 (minimum)

Power supplies: Dual, optional dual 700W DC-DC   
OS Supported Microsoft Windows Server® including Hyper-V®
VMware® ESX Server™
Red Hat® Enterprise Linux® (RHEL)
SUSE® Enterprise Linux® (SLES)
Oracle® Linux®
Citrix® XenServer®


¡@
For a complete list of supported OS versions including software initiators, NICs/CNAs & HBAs, please see the Dell Storage Compatibility Matrix: http://en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/20438558.
¡@
Physical
¡@
Height: 4U / 175 mm (6.87 inches)
Width: 446 mm (17.57 inches)
Depth: 580 mm (22.83 inches)
Weight: 47.1 kg (103.8 lb)**
Height: 2U / 87 mm (3.42 inches)
Width: 446 mm (17.57 inches)
Depth: 546 mm (21.50 inches)
Weight: 26.4 kg (58.3 lb)**
Height: 2U / 87 mm (3.42 inches)
Width: 446 mm (17.57 inches)
Depth: 546 mm (21.50 inches)
Weight: 26.4 kg (58.3 lb)**
Height: 2U / 87 mm (3.42 inches)
Width: 446 mm (17.57 inches)
Depth: 546 mm (21.50 inches)
Weight: 26.4 kg (58.3 lb)**
Height: 2U / 87 mm (3.42 inches)
Width: 446 mm (17.57 inches)
Depth: 546 mm (21.50 inches)
Weight: 26.4 kg (58.3 lb)**
Packaged physical: Length: 905 mm (35.63 inches) Width: 607 mm (23.88 inches) Depth: 521 mm (20.50 inches)
Packaged weight: 66.0 kg (145 lbs)**
Packaged physical: Length: 851 mm (33.50 inches) Width: 616 mm (24.25 inches) Depth: 508 mm (20.00 inches)
Packaged weight: 36.0 kg (79.3 lbs)**
Packaged physical: Length: 851 mm (33.50 inches) Width: 616 mm (24.25 inches) Depth: 508 mm (20.00 inches)
Packaged weight: 36.0 kg (79.3 lbs)**
Packaged physical: Length: 851 mm (33.50 inches) Width: 616 mm (24.25 inches) Depth: 508 mm (20.00 inches)
Packaged weight: 36.0 kg (79.3 lbs)**
Packaged physical: Length: 851 mm (33.50 inches) Width: 616 mm (24.25 inches) Depth: 508 mm (20.00 inches)
Packaged weight: 36.0 kg (79.3 lbs)**

¡@


The following specifications apply to all EqualLogic PS6210 series models:

Storage Controllers: Dual controllers with 16GB non-volatile memory per controller

Network Interfaces: Management network: One 100BASE-TX per controller

Interface ports: Two 10GBASE-T with RJ45 and two 10GbE SFP+ for fibre or twin-ax copper cabling

Volumes: Up to 1,024

Snapshots: 512 per volume/up to 10,000 total per group

Volume connections per PS series pool/group: Up to 1024/4096

Host Protocol: Any standards-compliant iSCSI initiator

TCP Network Support: IPv4, IPv6 compliant. USGv6 certified.

Expansion Option: Can be combined with other PS Series arrays in the same SAN group online; maximum of 16 total arrays per group that can support a maximum of 384 drives and up to 1.536PB with the PS6210 Series. With multigenerational capabilities, you can support up to 10 cross-generation types of controllers with multiple network configurations and drive types in a new or existing PS Series SAN resource pool, all managed by a single interface. Maximum number of drives and capacity varies based on configuration model and drive types. Additionally, PS and SC Series offer common management and cross-platform replication capabilities between arrays, providing PS Series customers the flexibility to add SC Series arrays to their environment, if and when they choose.1

Reliability:
Redundant hot-swappable controllers with vertical port sharing
Hot-swappable disks and power supplies

Enclosure Monitoring System:
Automatic spare configuration and utilization
SMART
Automatic bad block replacement
Auto-Stat Disk Monitoring System (ADMS) to monitor health of data on disk drives

Management Interfaces:
Dell Storage Manager (DSM): Allows you to perform day-to-day tasks across SC and PS Series arrays from a single management interface1
Group Manager (GUI & CLI)
SAN Headquarters multi-group performance and event monitoring tool
Virtual Storage Manager vCenter plugin
Serial console
Ability to configure a separate management network
SNMP, telnet, SSH, HTTP, Web (SSL)
Host scripting, including Windows PowerShell
Multi-administrator support

Security:

CHAP authentication
Access control for iSCSI as well as new Access Control Policies
Access control for management interfaces including Active Directory, LDAP, or RADIUS support

Notification Methods: SAN Headquarters alerting, including Dell SupportAssist,SNMP traps, e-mail, syslog

Environmental Operating Conditions:
Temperature range: 5¢X to 40¢XC (41¢X to 104¢XF)
Storage temperature: ¡V40¢X to 65¢XC (¡V40¢X to 149¢XF)
Altitude: For altitudes above 2950 feet, the maximum operating temperature is derated 1ºF/550 ft.
Operating Relative humidity: 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour
Operational shock: Half-sine shock 31G +/- 5% with a pulse duration of 2.6ms +/- 10% in operational orientations only
Operating Vibration: 0.26 Grms (5 to 350 Hz) for 5 minutes in operational orientations
Acoustics Category 4: <=7.2 bels at 23C +/- 2C
Air Quality: Airborne contaminant level of G1 or lower as defined by ISA-S71.04-1985

Rack Support: ReadyRails™ II static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded-hole racks

Regulatory information:

Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

¡@

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºDELL - EqualLogic PS6210 Series Arrays - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºDELL - DELL EqualLogic PS6210 Series Arrays±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@