­º­¶> Àx¦s³]³Æ/³Æ¥÷¤è®×>iSCSI¸Ñ¨M¤è®×>iSCSIºÏºÐ°}¦C

>>ÂsÄý©Ò¦³NetAppÀx¦s³]³Æ/³Æ¥÷¤è®×>

NetApp
NetApp E2700

«¬¸¹¡GNetApp E2700


NetAppNetApp E2700


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºNetApp - NetApp E2700 - Àx¦s³]³Æ/³Æ¥÷¤è®×>
³Ì¦nªºNetApp - NetApp E2700±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®×>iSCSI¸Ñ¨M¤è®×>iSCSIºÏºÐ°}¦C Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óNetApp¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§NetApp²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§NetApp­ì¼t°t¥ó


¡@

¡@

¡@


NetApp
NetApp E2700 - ServerBank¸ê°T±ÄÁʺô
NetApp E2700
Àx¦s³]³Æ/³Æ¥÷¤è®×>iSCSI¸Ñ¨M¤è®×>iSCSIºÏºÐ°}¦C


¡@
²£«~³W®æ
¡@

E2700 Technical Specifications
All data in this table applies to dual-controller configurations.

E2760 E2724 E2712
Maximum Raw Capacity 480TB
with expansion 1.5PB
43.2TB
with expansion 1.4PB
96TB
with expansion 1.5PB
Maximum Drives* 192 with mixed expansion shelves 
120 SSDs (limit of 25 per 60-drive shelf) 
192 with expansion shelves
120 SSDs
192 with expansion shelves
Form factor 4U60 drives (both 2.5" and 3.5") 2U24 drives (2.5") 2U12 drives (3.5")
Drive Types
  • 2/3/4/6 NL-SAS 7.2K FDE/non-FDE
  • 8TB NL-SAS 7.2k non-FDE
  • 6TB NL-SAS 7.2K FIPS
    ¡@
  • 600/900GB, 1.2/1.8TB SAS 10K FDE/non-FDE
  • 1.8TB SAS 10K FIPS
    ¡@
  • 400/800GB, 1.6/3.2*TB SSD non-FDE
  • 800GB SSD FDE
  • 1.6TB SSD FIPS*
    ¡@
  • 600/900GB, 1.2/1.8TB SAS 10K FDE/non-FDE
  • 1.8TB SAS 10K FIPS
    ¡@
  • 400/800GB, 1.6/3.2*TB SSD non-FDE
  • 800GB SSD FDE
  • 1.6TB SSD FIPS*
    ¡@
  • 2/3/4/6 7.2K NL-SAS FDE/non-FDEE
  • 8TB NL-SAS 7.2k non-FDE
  • 6TB 7.2K NL-SAS FIPS
    ¡@
System Memory 8 or 16GB
Included Host I/O Ports 4 port 12Gb SAS
Optional Host I/O Ports 4 ports or 8 ports 10Gb iSCSI (copper)
4 ports or 8 ports 10Gb iSCSI (optical)
4 ports or 8 ports 16Gb FC
4 ports or 8 ports 12Gb SAS
Expansion Disk Shelves DE6600 (4U60 drives):
  • 2/3/4/6 NL-SAS 7.2K FDE/non-FDE
  • 8TB NL-SAS 7.2k non-FDE
  • 6TB NL-SAS FIPS
    ¡@
  • 600/900GB, 1.2/1.8TB SAS 10K FDE/non-FDE
  • 1.8TB SAS 10K FIPS
    ¡@
  • 400/800GB, 1.6/3.2TB* SSD non-FDE
  • 800GB SSD FDE
  • 1.6TB SSD FIPS*

DE5600 (2U24 drives):

  • 600/900GB, 1.2/1.8 TB SAS 10K FDE/non-FDE
  • 1.8TB SAS 10K FIPS
    ¡@
  • 400/800GB, 1.6/3.2TB* SSD non-FDE
  • 800GB SSD FDE
  • 1.6TB SSD FIPS*

DE1600 (2U24 drives):

  • 2/3/4/6 NL-SAS 7.2K FDE/non-FDE
  • 8TB NL-SAS 7.2k non-FDE
  • 6TB NL-SAS 7.2K FIPS
    ¡@
Operating System & System Management SANtricity OS 8.25
SANtricity Storage Manager 11.25
High Availability Features Dual active controller with automated I/O path failover
Dynamic Disk Pools and traditional RAID levels 0, 1, 3, 5, 6, and 10
Redundant, hot-swappable storage controllers, disk drives, power supplies and fans
Automatic DDP or RAID rebuild following a drive failure
Mirrored data cache with battery backup and de-stage to flash
SANtricity proactive drive health monitoring
Greater than 99.999% availability (with appropriate configuration and service plans)
Host Operating Systems Microsoft® Windows® Server, Red Hat Enterprise Linux®, Novell SUSE Linux Enterprise Server, Apple® Mac® OS, Oracle® Solaris, HP-UX, CentOS Linux, Oracle Enterprise Linux, IBM AIX, VMware® ESX™
Software Features Standard
  • SANtricity Mirroring
  • SANtricity Volume Copy
  • SANtricity Snapshot
  • SANtricity SSD Cache
  • SANtricity Thin Provisioning
  • Dynamic Disk Pools

Optional Software Features

  • SANtricity drive encryption
System Capabilities Data assurance (T10-PI standard)
Dynamic volume expansion
Dynamic capacity expansion
Dynamic RAID-level migration
Dynamic segment size migration
System Event Monitor
Proactive drive heath monitoring
AutoSupport
Online SANtricity OS upgrades & drive firmware upgrades
VMware vSphere® Storage APIs ¡V Array Integration (VAAI)
Microsoft Offloaded Data Transfer (ODX)
Application Plug-ins*** SANtricity Plug-in for Oracle Enterprise Manager
SANtricity Management Pack for Microsoft System Center Operations Manager (SCOM)
SANtricity Plug-in for Microsoft SQL Server™ Management Studio (SSMS)
SANtricity Plug-in for VMware vCenter®
SANtricity VASA Provider
SANtricity Storage Replication Adapter for VMware vCenter Site Recovery Manager
SANtricity Performance App for Splunk® Enterprise
SANtricity Module for Puppet
SANtricity Module for Chef
SANtricity Plug-in for Nagios
¡@
Open Management OpenStack Swift on E-Series Storage
¡@

NetApp Cinder Driver
¡@

SANtricity Web Services Proxy (REST and SYMbol Web) 

SANtricity SMI-S Provider
¡@

SANtricity PowerShell Toolkit

System Maximums Hosts: 256 
Volumes: 512 
Snapshot copies: 512 
Mirrors: 32
* Expected availability mid-2016
** All models are capable of reaching 192 disk drives when configured with intermixed drive shelves.
*** No-charge download from my support.netapp.com

¡@
Energy StarES_logo.png title:
  • All ENERGY STAR certified systems are dual power/cooling/controllers, FDE or non-FDE drives of any capacity, with any host interface option
  • NetApp E-Series E2712 up to 24 HDD drives w/DE1600 shelf
  • NetApp E-Series E2724 up to 48 HDD drives w/DE5600 shelf
  • NetApp E-Series E2760 up to 120 HDD drives w/DE6600 shelf

¡@
Dimensions and
Weight
E2760 System Shelf
DE6600 Disk Shelf
E2724 System Shelf
DE5600 Disk Shelf
E2712 System Shelf
DE1600 Disk Shelf
Height 7.0" (17.78 cm) 3.47" (8.81 cm) 3.4" (8.64 cm)
Width 19" (48.26 cm) 19" (48.26 cm) 19" (48.26 cm)
Depth 32.5" (82.55 cm) 19.6" (49.78 cm) 21.75" (55.25 cm)
Weight (max) 232 lb (105.2 kg) 57.32 lb (26 kg) 59.52 lb (27 kg)

¡@

¡@
E2760 system shelf E2724 system shelf E2712 system shelf
Typical Maximum Typical Maximum Typical Maximum
KVA 1.009 1.219 0.482 0.632 0.361 0.516
Watts 999 1206 477 626 358 511
BTU 3408 4117 1628 2134 1220 1744

¡@
DE6600 disk shelf DE5600 disk shelf DE1600 disk shelf
Typical Maximum Typical Maximum Typical Maximum
KVA 0.815 1.024 0.296 0.446 0.175 0.325
Watts 806 1014 293 442 174 322
BTU 2752 3460 1001 1507 593 1099

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºNetApp - NetApp E2700 - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºNetApp - NetApp E2700±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 NASºô¸ôÀx¦sÀɮצøªA¾¹
 ServerBank±ÀÂ˾÷ºØ
 ®à¤W«¬
 ¾÷¬[¦¡
 ª½¥ß¦¡
 ºÏºÐ°}¦C°t¥ó
 ¦Û°Ê¥úºÐ«þ¨©¾÷
 ¥~±µ¦¡µwºÐ
 ºÏ±a¾÷
 SDLT
 DLT
 LTO 1/2/3/4
 Ultrium I
 Ultrium II
 SAIT
 AIT
 AIT Turbo
 DAT
 DDS
 ºÏ±a´«±a¾÷Autoloader
 iSCSI¸Ñ¨M¤è®×
 iSCSIºÏºÐ°}¦C
 iSCSI¾ô±µ¾¹
 ºÏºÐ°}¦CRAID
 ServerBank±ÀÂ˾÷ºØ
 iSCSI
 iSCSI to SAS
 SATA
 SCSI-to-SCSI
 SCSI-to-IDE
 SCSI-to-SATA
 Fibre-to-SCSI
 Fibre-to-IDE
 Fibre-to-SATA
 Fibre-to-Fibre
 Fibre to SAS
 USB-to-IDE
 SATA-to-SATA
 SATA-to-IDE
 SAS
 IDE-to-IDE
 1394-to-IDE
 JBOD
 ºÏºÐ°}¦CÂd
 1394B-to-SATAII
 1394B-to PATA
 °ïÅ|¦¡Àx¦s¥~±µ²°
 SAS-to-SATA
 SAS-to-SAS
 SCSI-to-SAS
 PCIE
 USB
 IDE
 SAN¸Ñ¨M¤è®×
 ¥úÅÖ³q¹D¥æ´«¾¹
 ¥úÅÖ³q¹D¤¶­±¥d
 SAN Storage
 SAN Software
 ¥úÅÖ³q¹D¾ô±µ¾¹
 ¾É¦V¾¹director
 ¥úÅÖ¼Ò²Õ
 Àx¦sºÞ²z³nÅé
 ºÏ±aÂd
 ºÏ±a
 ¦Û°Ê´«¤ù¥úºÐ
 ÂÅ¥ú¥úºÐÂd
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > Àx¦s³]³Æ/³Æ¥÷¤è®×>iSCSI¸Ñ¨M¤è®×>iSCSIºÏºÐ°}¦C


NetAppNetApp E2700

NetApp E2700


¼tµP¡GNetApp      >>ÂsÄýNetApp¥þ³¡²£«~
«¬¸¹¡GNetApp E2700



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºNetApp - NetApp E2700 - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºNetApp - NetApp E2700±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®×>iSCSI¸Ñ¨M¤è®×>iSCSIºÏºÐ°}¦C Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óNetApp¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§NetApp²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§NetApp­ì¼t°t¥ó


¡@

¡@

¡@


NetApp
NetApp E2700 - ServerBank¸ê°T±ÄÁʺô
NetApp E2700
Àx¦s³]³Æ/³Æ¥÷¤è®×>iSCSI¸Ñ¨M¤è®×>iSCSIºÏºÐ°}¦C


¡@
²£«~³W®æ
¡@

E2700 Technical Specifications
All data in this table applies to dual-controller configurations.

E2760 E2724 E2712
Maximum Raw Capacity 480TB
with expansion 1.5PB
43.2TB
with expansion 1.4PB
96TB
with expansion 1.5PB
Maximum Drives* 192 with mixed expansion shelves 
120 SSDs (limit of 25 per 60-drive shelf) 
192 with expansion shelves
120 SSDs
192 with expansion shelves
Form factor 4U60 drives (both 2.5" and 3.5") 2U24 drives (2.5") 2U12 drives (3.5")
Drive Types
  • 2/3/4/6 NL-SAS 7.2K FDE/non-FDE
  • 8TB NL-SAS 7.2k non-FDE
  • 6TB NL-SAS 7.2K FIPS
    ¡@
  • 600/900GB, 1.2/1.8TB SAS 10K FDE/non-FDE
  • 1.8TB SAS 10K FIPS
    ¡@
  • 400/800GB, 1.6/3.2*TB SSD non-FDE
  • 800GB SSD FDE
  • 1.6TB SSD FIPS*
    ¡@
  • 600/900GB, 1.2/1.8TB SAS 10K FDE/non-FDE
  • 1.8TB SAS 10K FIPS
    ¡@
  • 400/800GB, 1.6/3.2*TB SSD non-FDE
  • 800GB SSD FDE
  • 1.6TB SSD FIPS*
    ¡@
  • 2/3/4/6 7.2K NL-SAS FDE/non-FDEE
  • 8TB NL-SAS 7.2k non-FDE
  • 6TB 7.2K NL-SAS FIPS
    ¡@
System Memory 8 or 16GB
Included Host I/O Ports 4 port 12Gb SAS
Optional Host I/O Ports 4 ports or 8 ports 10Gb iSCSI (copper)
4 ports or 8 ports 10Gb iSCSI (optical)
4 ports or 8 ports 16Gb FC
4 ports or 8 ports 12Gb SAS
Expansion Disk Shelves DE6600 (4U60 drives):
  • 2/3/4/6 NL-SAS 7.2K FDE/non-FDE
  • 8TB NL-SAS 7.2k non-FDE
  • 6TB NL-SAS FIPS
    ¡@
  • 600/900GB, 1.2/1.8TB SAS 10K FDE/non-FDE
  • 1.8TB SAS 10K FIPS
    ¡@
  • 400/800GB, 1.6/3.2TB* SSD non-FDE
  • 800GB SSD FDE
  • 1.6TB SSD FIPS*

DE5600 (2U24 drives):

  • 600/900GB, 1.2/1.8 TB SAS 10K FDE/non-FDE
  • 1.8TB SAS 10K FIPS
    ¡@
  • 400/800GB, 1.6/3.2TB* SSD non-FDE
  • 800GB SSD FDE
  • 1.6TB SSD FIPS*

DE1600 (2U24 drives):

  • 2/3/4/6 NL-SAS 7.2K FDE/non-FDE
  • 8TB NL-SAS 7.2k non-FDE
  • 6TB NL-SAS 7.2K FIPS
    ¡@
Operating System & System Management SANtricity OS 8.25
SANtricity Storage Manager 11.25
High Availability Features Dual active controller with automated I/O path failover
Dynamic Disk Pools and traditional RAID levels 0, 1, 3, 5, 6, and 10
Redundant, hot-swappable storage controllers, disk drives, power supplies and fans
Automatic DDP or RAID rebuild following a drive failure
Mirrored data cache with battery backup and de-stage to flash
SANtricity proactive drive health monitoring
Greater than 99.999% availability (with appropriate configuration and service plans)
Host Operating Systems Microsoft® Windows® Server, Red Hat Enterprise Linux®, Novell SUSE Linux Enterprise Server, Apple® Mac® OS, Oracle® Solaris, HP-UX, CentOS Linux, Oracle Enterprise Linux, IBM AIX, VMware® ESX™
Software Features Standard
  • SANtricity Mirroring
  • SANtricity Volume Copy
  • SANtricity Snapshot
  • SANtricity SSD Cache
  • SANtricity Thin Provisioning
  • Dynamic Disk Pools

Optional Software Features

  • SANtricity drive encryption
System Capabilities Data assurance (T10-PI standard)
Dynamic volume expansion
Dynamic capacity expansion
Dynamic RAID-level migration
Dynamic segment size migration
System Event Monitor
Proactive drive heath monitoring
AutoSupport
Online SANtricity OS upgrades & drive firmware upgrades
VMware vSphere® Storage APIs ¡V Array Integration (VAAI)
Microsoft Offloaded Data Transfer (ODX)
Application Plug-ins*** SANtricity Plug-in for Oracle Enterprise Manager
SANtricity Management Pack for Microsoft System Center Operations Manager (SCOM)
SANtricity Plug-in for Microsoft SQL Server™ Management Studio (SSMS)
SANtricity Plug-in for VMware vCenter®
SANtricity VASA Provider
SANtricity Storage Replication Adapter for VMware vCenter Site Recovery Manager
SANtricity Performance App for Splunk® Enterprise
SANtricity Module for Puppet
SANtricity Module for Chef
SANtricity Plug-in for Nagios
¡@
Open Management OpenStack Swift on E-Series Storage
¡@

NetApp Cinder Driver
¡@

SANtricity Web Services Proxy (REST and SYMbol Web) 

SANtricity SMI-S Provider
¡@

SANtricity PowerShell Toolkit

System Maximums Hosts: 256 
Volumes: 512 
Snapshot copies: 512 
Mirrors: 32
* Expected availability mid-2016
** All models are capable of reaching 192 disk drives when configured with intermixed drive shelves.
*** No-charge download from my support.netapp.com

¡@
Energy StarES_logo.png title:
  • All ENERGY STAR certified systems are dual power/cooling/controllers, FDE or non-FDE drives of any capacity, with any host interface option
  • NetApp E-Series E2712 up to 24 HDD drives w/DE1600 shelf
  • NetApp E-Series E2724 up to 48 HDD drives w/DE5600 shelf
  • NetApp E-Series E2760 up to 120 HDD drives w/DE6600 shelf

¡@
Dimensions and
Weight
E2760 System Shelf
DE6600 Disk Shelf
E2724 System Shelf
DE5600 Disk Shelf
E2712 System Shelf
DE1600 Disk Shelf
Height 7.0" (17.78 cm) 3.47" (8.81 cm) 3.4" (8.64 cm)
Width 19" (48.26 cm) 19" (48.26 cm) 19" (48.26 cm)
Depth 32.5" (82.55 cm) 19.6" (49.78 cm) 21.75" (55.25 cm)
Weight (max) 232 lb (105.2 kg) 57.32 lb (26 kg) 59.52 lb (27 kg)

¡@

¡@
E2760 system shelf E2724 system shelf E2712 system shelf
Typical Maximum Typical Maximum Typical Maximum
KVA 1.009 1.219 0.482 0.632 0.361 0.516
Watts 999 1206 477 626 358 511
BTU 3408 4117 1628 2134 1220 1744

¡@
DE6600 disk shelf DE5600 disk shelf DE1600 disk shelf
Typical Maximum Typical Maximum Typical Maximum
KVA 0.815 1.024 0.296 0.446 0.175 0.325
Watts 806 1014 293 442 174 322
BTU 2752 3460 1001 1507 593 1099

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºNetApp - NetApp E2700 - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºNetApp - NetApp E2700±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@