StoreEasy
1450 |
¡@ |
¡@ |
Dimensions
(H x W x D) |
4 LFF - 1.7 x 17.1 x 23.9 inches (4.29 x 43.46 x 60.76 cm) |
Weight
(approximate) |
Maximum:
(all hard drives,
power supplies, and
processors Installed) |
33.04 Ib (15kg) |
Minimum:
(one hard drive,
power supply, and
processor installed) |
22.03 lb (10kg) |
100 to 240 VAC |
Input
Requirements
or Standard 460W
SU, see power
pecifications tables
or detail on 460W,
50W and 1200W
ower supplies) |
Rated Input Current |
For 550W Power Supply:
6.7 A (at 100 VAC)
3.3 A (at 100 VAC) |
Rated Input
Frequency |
47 to 63 Hz |
Rated Input Power |
For 550 W Power Supply:
< 670 W (at 100 VAC),
< 660 W (at 200 VAC), |
BTU Rating |
Maximum |
For 550 W Power Supply:
2201 BTU/hr (at 100 VAC),
2153 BTU/hr (at 200 VAC) |
Power
Specifications |
To review typical system power ratings use the Power
Advisor which is available via
the online tool located at URL: http://www.hp.com/go/proliant-energy-efficient
or http://www.hp.com/go/hppoweradvisor - Click on the system of
interest.
Example: DL160 Gen9- Follow the instructions of the next screens. |
Power Supply
Output |
Rated Steady-
State Power |
For 550 W Power Supply:
550 W (at 100 VAC),
550 W (at 200 VAC), |
Maximum Peak
Power |
For 550 W Power Supply:
550 W (at 100 VAC),
550 W (at 200 VAC), |
System Inlet
Temperature |
Standard
Operating Support |
10¢X to 35¢XC (50¢X to 95¢XF) at sea level with an altitude derating
of 1.0¢XC per every 305 m (1.8¢XF per every 1000 ft) above sea
level to a maximum of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 20¢XC/hr (36¢XF/hr). The
upper limit and rate of change may be limited by the type and
number of options installed. System performance during
standard operating support may be reduced if operating with a
fan fault or above 30¢XC (86¢XF). |
Extended Ambient
Operating Support |
For approved hardware configurations, the supported system
inlet range is extended to be: 5¢X to 10¢XC (41¢X to 50¢XF) and 35¢X
to 40¢XC (95¢X to 104¢XF) at sea level with an altitude derating of
1.0¢XC per every 175 m (1.8¢XF per every 574 ft) above 900 m
(2953 ft) to a maximum of 3050 m (10,000 ft). The approved
hardware configurations for this system are listed at the URL:
http://www.hp.com/servers/ashrae. |
For approved hardware configurations, the supported system
inlet range is extended to be: 40¢X to 45¢XC (104¢X to 113¢XF) at
sea level with an altitude derating of 1.0¢XC per every 125 m
(1.8¢XF per every 410 ft) above 900 m (2953 ft) to a maximum
of 3050 m (10,000 ft). The approved hardware configurations
for this system are listed at the URL:
http://www.hp.com/servers/ashrae. |
System performance may be reduced if operating in the
extended ambient operating range or with a fan fault.
NOTE: Supports A3 and A4 extended ambient. |
Relative
Humidity |
Non-operating |
-30¢X to 60¢XC (-22¢X to 140¢XF). Maximum rate of change is
20¢XC/hr (36¢XF/hr). |
Operating |
Minimum to be the higher (more moisture) of -12¢XC (10.4¢XF)
dew point or 8% relative humidity. Maximum to be the lower
(less moisture) of 24¢XC (75.2¢XF) dew point or 90% relative
humidity. |
(non-condensing) |
Non-operating |
5% to 95% relative humidity (Rh), 38.7¢XC (101.7¢XF) maximum
wet bulb temperature, non-condensing. |
Altitude |
Operating |
3048 m (10,000 ft). This value may be limited by the type and
number of options installed. Maximum allowable altitude change
rate is 457 m/min (1500 ft/min). |
Non-operating |
9144 m (30,000 ft). Maximum allowable altitude change rate is
457 m/min (1500 ft/min). |
Acoustic Noise |
Listed are the declared A-Weighted sound power levels (LWAd)
and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the
product is operating in a 23¢XC ambient environment. Noise emissions were
measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance
with ISO 9296 (ECMA 109). |
Idle |
L WAd |
Entry 5.1 B
Base 5.2 B
Performance 5.0 B |
L pAm |
Entry 34.2 dBA
Base 35.9 dBA
Performance 34.9 dBA |
Operating |
L WAd |
Entry 5.3 B
Base 5.3 B
Performance 5.6 B |
L pAm |
Entry 36.3 dBA
Base 36.2 dBA
Performance 39.7 dBA |
Emissions
Classification
(EMC) |
FCC Rating |
Class A |
Normative
Standards |
CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003;
CNS13438; GB9254; K22; K24; EN 61000-3-2; EN 61000-3-3;
EN 60950-1; IEC 60950-1 |