StoreEasy
1650/1850 |
Tower
Dimensions |
SFF Drives: 3.44 x 17.54 x 26.75 in (8.73 x 44.55 x
67.94 cm)
LFF Drives: 3.44 x 17.54 x 28.75 in (8.73 x 44.55 x 73.02 cm) |
Weight
(approximate) |
Minimum:
(Minimum - 8SFF
chassis with 1xSFF
HDD and 7 HDD
blanks, 1x
processor,
1x power supply
(plus blank), 1x
Flexible Smart
Array, 1x Riser
installed) |
32.6 lb (14.759 kg) |
Maximum:
(Maximum - 12
LFF hard drives
(No rear drives), 2x
processors,
2x power supplies,
1x Flexible Smart
Array, 2x Risers
installed) |
55lb (24.9g) |
Input
Requirements |
Range Line
Voltage |
100 to 120 VAC
200 to 240 VAC |
BTU Rating |
Maximum |
For 800W Power Supply: 3207 BTU/hr (at 100 VAC), 3071
BTU/hr (at 200 VAC), 3112 BTU/hr (at 240 VAC) for China
Only |
Power Supply
Output
(per power
supply) |
Rated Steady-
State Power |
For 1400W Power Supply: 1400W (at 100 VAC), 1400W (at
240 VAC), 1400W (at 240 VAC)
For 800W Power Supply: 800W (at 100 VAC), 800W (at 240
VAC), 800W (at 240 VAC) input for China only
For 500W Power Supply: 500W (at 100 VAC), 500W (at 240
VAC), 500W (at 240 VAC) input for China only |
¡@ |
Maximum Peak
Power |
For 1400W Power Supply: 1400W (at 100 to 127 VAC),
1400W (at 200 to 240 1VAC), 1400W (at 240 VAC) input for
China only
For 800W Power Supply: 800W (at 100 to 127 VAC), 800W
(at 200 to 240 1VAC), 800W (at 240 VAC) input for China
only
For 500W Power Supply: 500W (at 100 to 127 VAC), 500W
(at 200 to 240 VAC), 500W (at 240 VAC) input for China only |
System Inlet
Temperature |
Standard
Operating Support |
10¢X to 35¢XC (50¢X to 95¢XF) at sea level with an altitude derating
of 1.0¢XC per every 305 m (1.8¢XF per every 1000 ft) above sea
level to a maximum of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 20¢XC/hr (36¢XF/hr). The
upper limit and rate of change may be limited by the type and
number of options installed. System performance during
standard operating support may be reduced if operating with a
fan fault or above 30¢XC (86¢XF). |
Extended Ambient
Operating Support |
For approved hardware configurations, the supported system
inlet range is extended to be: 5¢X to 10¢XC (41¢X to 50¢XF) and 35¢X
to 40¢XC (95¢X to 104¢XF) at sea level with an altitude derating of
1.0¢XC per every 175 m (1.8¢XF per every 574 ft) above 900 m
(2953 ft) to a maximum of 3048
m (10,000 ft). The approved hardware configurations for this
system are listed at the URL:
http://www.hp.com/servers/ashrae. |
For approved hardware configurations, the supported system
inlet range is extended to be: 40¢X to 45¢XC (104¢X to 113¢XF) at
sea level with an altitude derating of 1.0¢XC per every 125 m
(1.8¢XF per every 410 ft) above 900 m (2953 ft) to a maximum
of 3048 m (10,000 ft). The approved hardware configurations
for this system are listed at the URL:
http://www.hp.com/servers/ashrae. |
System performance may be reduced if operating in the
extended ambient operating range or with a fan fault.
NOTE: Supports A3 extended ambient. |
Relative
Humidity |
Non-operating |
-30¢X to 60¢XC (-22¢X to 140¢XF). Maximum rate of change is
20¢XC/hr(36¢XF/hr). |
Operating |
Minimum to be the higher (more moisture) of -12¢XC (10.4¢XF)
dew point or 8% relative humidity. Maximum to be the lower
(less moisture) of24¢XC (75.2¢XF) dew point or 90% relative
humidity. |
(non-condensing) |
Non-operating |
5% to 95% relative humidity (Rh), 38.7¢XC (101.7¢XF) maximum
wet bulb temperature, non-condensing. |
Altitude |
Operating |
3048 m (10,000 ft). This value may be limited by the type and
number of options installed. Maximum allowable altitude change
rate is 457 m/min (1500 ft/min). |
Non-operating |
9144 m (30,000 ft). Maximum allowable altitude change rate is
457 m/min (1500 ft/min). |
Acoustic Noise |
Listed are the declared A-Weighted sound power levels (LWAd)
and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the
product is operating in a 23¢XC ambient environment. Noise emissions were
measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance
with ISO 9296 (ECMA 109). |
Idle |
L WAd |
4.0 B Entry LFF
4.1 B Entry
4.2 B Base
5.7 B Base LFF
4.3 B Perf |
L pAm |
23 dBA Entry LFF
24 dBA Entry
24 dBA Base
39 dBA Base LFF
25 dBA Perf |
Operating |
L WAd |
4.3 B Entry LFF
4.6 B Entry
4.8 B Base
5.9 B Base LFF
5.6 B Perf |
L pAm |
25 dBA Entry LFF
29 dBA Entry
30 dBA Base
31 dBA Base LFF
39 dBA Perf |
Emissions
Classification
(EMC) |
FCC Rating |
Class A |
Normative
Standards |
CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003;
CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3;
EN 60950-1; IEC 60950-1 |