Lenovo System x 2U ¾÷¬[¦¡¦øªA¾¹¡ySR650¡z |
³W
®æ |
¦øªA¾¹®Æ¸¹ |
7X06A05QCN |
¡@ |
¡@ |
Intel Xeon Silver 4110 8C 2.1GHz
/85W, 1*16GB, Raid 930-16i + 4G Flash, 3.5" SAS/SATA Open Bays(std: 12),
1*750W, 4* GbE, 3Y NBD(5*8) |
´¹¤ù²Õ |
Intel C624 |
¡@ |
¡@ |
¡@ |
°O¾ÐÅé(¤º«Ø) |
¼Ð·Ç°O¾ÐÅé®e¶q¡G16G*1 |
¡@ |
¡@ |
°O¾ÐÅé®e¶q |
³Ì¤j°O¾ÐÅé®e¶q : 1.5 TB(64GB x
24DIMMs, ¶·¿ïÁÊ LP
RDIMM), ³Ì¤j24²ÕDIMM
Socket, ¨CÁûCPU³Ì¦h¥i¨Ï¥Î
12²ÕDIMM |
¡@ |
¡@ |
¤ä´©ECC (error correction
code), SDDC (Chipkill), memory mirroring |
Åã¥Ü´¹¤ù |
¤º«ØMatrox G200eR2 16MB
SDRAM integrated into Xclarity Controller(Max : 1600 x 1200 at 75Hz with
16M Color) |
ºÏºÐ±±¨î¤¶± |
¤º«ØRaid 930 16i,
¤ä´© Raid-0/1/5/50/60,
¼Ð·Ç4G Flash, |
¡@ |
µwºÐÂX¥R¤è¦¡ |
¼Ð·ÇµwºÐ¼Æ¶q : 0(¿ïÁÊ),
¼Ð·Ç¥i¦w¸Ë12Áû
3.5" HDD (³Ì¤j¥i¦w¸Ë14²Õ3.5"µwºÐ),
¶·¿ïÁÊÂX¥R®M¥ó Expansion
Unit (7XH7A06253) |
ºô¸ô¤¶± |
¼Ð·Ç¤º«Ø 4 x 1GbE port(LOM) & 1 x 10/100/1000 Ethernet System Management
port(RJ-45) |
¥úºÐ¾÷ |
µL,
½Ð¿ïÁÊ¥~±µ¦¡¥úºÐ¾÷(7XA7A05926)
USB External DVD-RW) |
¡@ |
I/O ´¡¼Ñ(Slot) |
¼Ð·Ç¥i¥ÎSlot4, Slot 1~3¶·¿ïÁʶR
Riser1(7X06A05QCN¼Ð·Ç¤º«ØRiser1),
Slot 5~6¶·¿ïÁÊ 2nd
CPU¤ÎRiser 2¤~¯à¨Ï¥Î,
Slot 7¶È¨Ñ¤º«Ø¦sÀx¥Î |
¡@ |
LOM card slot |
¡@ |
¡@ |
¡@ |
¡@ |
Slot 1: PCIe 3.0 x16 or PCIe 3.0 x8; full-height, half-length (PCIe x16
slot is double-wide) |
¡@ |
Slot 2: PCIe 3.0 x8; full-height, half-length (not present if the slot 1
is PCIe x16 or slot 3 is ML2 x16) |
¡@ |
Slot 3: PCIe 3.0 x8, or ML2 x8, or ML2 x16; full-height, half-length |
¡@ |
¡@ |
Slot 4: PCIe 3.0 x8; low profile (vertical slot on system planar) |
¡@ |
¡@ |
Slot 5: PCIe 3.0 x16; full-height, half-length |
¡@ |
¡@ |
Slot 6: PCIe 3.0 x16; full-height, half-length |
¡@ |
¡@ |
Slot 7: PCIe 3.0 x8 (dedicated to an internal storage controller) |
¡@ |
I/O ¿é¥X¤J°ð |
Front: 1 x USB 3.0
port/ 1 x USB 2.0 support Xclarity Controller Access/ (¿ïÁÊ)
1 x DB-15 VGA port |
¡@ |
Rear: 2 x USB 3.0 port
/ 1 x VGA port(DB-15)/ (¿ïÁÊ)
1 x DB-9 series port |
¿é¤J¸Ë¸m |
Áä½L(¿ïÁÊ
USB only) / ·Æ¹«(¿ïÁÊ
USB only) |
¡@ |
ÂX¥R¹j¶¡(Bay) |
¼Ð·Ç: 8
¤p(´£¨Ñ
2.5" Hot-Swap HDD Bays*8, ¶·ÁʶRì¼tµwºÐ) |
¡@ |
¥D¾÷«¬ºA |
2U ¾÷¬[¦¡ |
¡@ |
¡@ |
¡@ |
´²¼ö¸Ë¸m |
Five (one processor) or six (two processors) hot-swap system fans with
N+1 redundancy. (¼Ð·Ç 5
²Õ·®°,
²Ä 6
²Õ¶R2nd CPU®ÉÀHCPU¥X³f) |
¹q·½¨ÑÀ³¾¹ |
¼Ð·Ç 1 x 750 W Platinum
Hot-Swap Power Supply (230V/115V), ¤ä´©
Redundant |
ºÞ²z³nÅé |
XClarity Controller (XCC) Standard, Advanced, or Enterprise (Pilot 4
chip), proactive platform alerts, light path diagnostics, |
¡@ |
XClarity Provisioning Manager, XClarity Essentials, XClarity
Administrator, XClarity Energy Manager. |
¤ä´©§@·~¨t²Î |
Microsoft Windows Server 2012 R2 and 2016; Red Hat Enterprise Linux 6
(x64) and 7; SUSE Linux Enterprise Server 11 (x64) and 12; VMware
vSphere (ESXi) 6.0 and 6.5. |
«O©T¤è¦¡ |
3¦~¹s¥ó/¤H¤u/¤u§@¤é¹j¤é¨ì©²ªA°È(NBD
5*8) |
¡@ |