­º­¶> ¨¾¬r¦w¥þ³nÅé>ÁͶÕ

>>ÂsÄý©Ò¦³TrendMicroÁͶը¾¬r¦w¥þ³nÅé>

TrendMicroÁͶÕ
TrendMicroÁÍ¶Õ TippingPoint Threat Protection System

«¬¸¹¡GTrendMicroÁÍ¶Õ TippingPoint Threat Protection System


TrendMicroÁͶÕTrendMicroÁÍ¶Õ TippingPoint Threat Protection System


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºTrendMicroÁÍ¶Õ - TrendMicroÁÍ¶Õ TippingPoint Threat Protection System - ¨¾¬r¦w¥þ³nÅé>
³Ì¦nªºTrendMicroÁÍ¶Õ - TrendMicroÁÍ¶Õ TippingPoint Threat Protection System±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Ú¨¾¬r¦w¥þ³nÅé>ÁÍ¶Õ Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óTrendMicroÁͶլÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§TrendMicroÁͶղ£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§TrendMicroÁͶխì¼t°t¥ó


¡@

¡@

¡@


TrendMicroÁͶÕ
TrendMicroÁÍ¶Õ TippingPoint Threat Protection System - ServerBank¸ê°T±ÄÁʺô
TrendMicroÁÍ¶Õ TippingPoint Threat Protection System
¨¾¬r¦w¥þ³nÅé>ÁͶÕ


¡@
²£«~³W®æ

8200TX §Þ³N³W®æ
¥\¯à
8200TX
¬y¶qÀˬd§]¦R¶q
3/5/10/15/20/30/40 Gbps
SSL ¬y¶qÀˬd§]¦R¶q
2Gbps (2K ª÷Æ_ SHA256)
SSL ¨C¬í·s³s½u¶¥¬q
5,000
SSL ¬y¶qÀˬd¦P®É§@·~¶¥¬q
100,000
¥­§¡¬G»Ù¶¡¹j (MTBF)
88,706 ¤p®É ( 25¢J Àô¹Ò)
©µ¿ð
<40 ·L¬í
¦w¥þÀô¹Ò (Security Context)
10,000,000
¦P®É§@·~¶¥¬q
120,000,000
¨C¬í·s³s½u
650,000
¾÷¨­³W®æ
1U
­«¶q
32 ­^½S (³Ì¤j¡A§t I/O ¼Ò²Õ)
29 ­^½S (§tªÅ¥Õ I/O ¼Ò²Õ)
¤Ø¤o (¼ex²`x°ª)
428mm (18.54 ¦T) ¼e x 631mm (24.84 ¦T) ²` x 44mm (1.73 ¦T) °ª
ºÞ²z³s±µ°ð
RJ45 ºÞ²z¥D±±¥x³s±µ°ð (115200 8N1)
RJ45 1GbE (10/100/1000 Mbps) ºÞ²zºô¸ô³s±µ°ð
ºÞ²z¤¶­±
Security Management System(SMS)¡FLocal Security Manager
(LSM)¡F
«ü¥O¦C¤¶­± (CLI)
ºô¸ô³s½u
2 ­Ó I/O ¼Ò²Õ´¡¼Ñ¡A¥i²V´¡¡G
6-Segment 1GE »É½u I/O ¼Ò²Õ
6-Segment 1GE SFP I/O ¼Ò²Õ
4-Segment 10GE SFP+ I/O ¼Ò²Õ
1-Segment 40GE QSFP+ I/O ¼Ò²Õ
4-Segment 1GE »É½uª½³q (Bypass) I/O ¼Ò²Õ
2-Segment 1GE SR/LR ¥úÅÖª½³q (Bypass) I/O ¼Ò²Õ
2-Segment 10GE SR/LR ¥úÅÖª½³q (Bypass) I/O ¼Ò²Õ
¤º«ØÀx¦s
32GB ¤º«Ø CFAST («È¤áµLªk¦Û¦æ§ó´«) / 32GB ¥~³¡1.8 ¦T SSD
¹qÀ£
100 ¦Ü 240 VAC / -40 ¦Ü -60 VDC
¹q¬y (³Ì¤j¡A§t¿Äµ·¹q·½)
12/6 Amps AC¡B24/16 Amps DC
¹q·½¨ÑÀ³¾¹
Âù/³Æ´© 750W ¹q·½¨ÑÀ³¾¹
§@·~·Å«×
32¢XF ¦Ü 104¢XF (0¢XC ¦Ü 40¢XC)
§@·~¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
«D§@·~/Àx¦s·Å«×
-4¢XF ¦Ü 158¢XF (-20¢XC ¦Ü 70¢XC)
«D§@·~/Àx¦s¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
®ü©Þ°ª«×
³Ì°ª 10,000 ­^§` (3,048 ¤½¤Ø)
¦w¥þ»{ÃÒ
UL 60950-1¡BIEC 60950-1¡BEN 60950-1¡BCSA 22.2 60950-1
²Å¦X RoHS ³W½d
¹qºÏ¬Û®e©Ê (EMC)
Class A¡BFCC¡BVCCI¡BKC¡BEN55022¡BCISPR 22¡BEN55024 CISPR 24¡BEN61000-3-
2¡BEN61000-3-3¡BCE ¼Ð»x


8400TX §Þ³N³W®æ
¥\¯à
8400TX
IPS ¬y¶qÀˬd§]¦R¶q
3/5/10/15/20/30/40 Gbps
SSL ¬y¶qÀˬd§]¦R¶q
2Gbps (2K ª÷Æ_ SHA256)
SSL ¬y¶qÀˬd¦P®É³s½u
100,000
SSL ¨C¬í·s³s½u¶¥¬q
5,000
©µ¿ð
<40 ·L¬í
¥­§¡¬G»Ù¶¡¹j (MTBF)
88,706 ¤p®É ( 25¢J Àô¹Ò)
¦w¥þÀô¹Ò (Security Context)
10,000,000
¦P®É§@·~¶¥¬q
120,000,000
¨C¬í³s½u
650,000
¾÷¨­³W®æ
2U
­«¶q
50 ­^½S (³Ì¤j¡A§t I/O ¼Ò²Õ)
41.5 ­^½S (§tªÅ¥Õ I/O ¼Ò²Õ)
¤Ø¤o 1U (¼ex²`x°ª)
428mm (18.54 ¦T) ¼e x 631mm (24.84 ¦T) ²` x 88mm (3.46 ¦T) °ª
ºÞ²z³s±µ°ð
RJ45 ºÞ²z¥D±±¥x³s±µ°ð (115200 8N1)
RJ45 1GbE (10/100/1000 Mbps) ºÞ²zºô¸ô³s±µ°ð
ºÞ²z¤¶­±
Security Management System(SMS)¡FLocal Security Manager (LSM)¡F
«ü¥O¦C¤¶­± (CLI)
ºô¸ô³s½u
4 ­Ó I/O ¼Ò²Õ´¡¼Ñ¡A¥i²V´¡¡G
6-Segment 1GE »É½u I/O ¼Ò²Õ
6-Segment 1GE SFP I/O ¼Ò²Õ
4-Segment 10GE SFP+ I/O ¼Ò²Õ
1-Segment 40GE QSFP+ I/O ¼Ò²Õ
4-Segment 1GE »É½uª½³q (Bypass) I/O ¼Ò²Õ
2-Segment 1GE SR/LR ¥úÅÖª½³q (Bypass) I/O ¼Ò²Õ
2-Segment 10GE SR/LR ¥úÅÖª½³q (Bypass) I/O ¼Ò²Õ
¤º«ØÀx¦s
32GB ¤º«Ø CFAST («È¤áµLªk¦Û¦æ§ó´«) / 32GB ¥~³¡1.8 ¦T SSD
¹qÀ£
100 ¦Ü 240 VAC / -40 ¦Ü -60 VDC
¹q¬y (³Ì¤j¡A§t¿Äµ·¹q·½)
12/6 Amps AC¡B24/16 Amps DC
¹q·½¨ÑÀ³¾¹
Âù/³Æ´© 750W ¹q·½¨ÑÀ³¾¹
§@·~·Å«×
32¢XF ¦Ü 104¢XF (0¢XC ¦Ü 40¢XC)
§@·~¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
«D§@·~/Àx¦s·Å«×
-4¢XF ¦Ü 158¢XF (-20¢XC ¦Ü 70¢XC)
«D§@·~/Àx¦s¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
®ü©Þ°ª«×
³Ì°ª 10,000 ­^§` (3,048 ¤½¤Ø)
¦w¥þ»{ÃÒ
UL 60950-1¡BIEC 60950-1¡B
EN 60950-1¡BCSA 22.2 60950-1
²Å¦X RoHS ³W½d
¹qºÏ¬Û®e©Ê (EMC)
Class A¡BFCC¡BVCCI¡BKC¡BEN55022¡BCISPR 22¡B
EN55024 CISPR 24¡BEN61000-3-2¡B
EN61000-3-3¡BCE ¼Ð»x


T ¨t¦C§Þ³N³W®æ

VIRTUAL THREAT PROTECTION SYSTEM

  • ¥\¯à
TippingPoint Standard Virtual vTPS Appliance
? VMWare ESXi 5.5¡B6.0
? KVM ¡V Redhat Enterprise Linux 6¡B7
ºô¸ôÅX°Êµ{¦¡ VMWare ¡V VMXNet3
? KVM ¡V virtIO
ÅÞ¿è®Ö¤ß¼Æ¶q 3 ©Î 4
°O¾ÐÅé»Ý¨D 8 GB
µwºÐªÅ¶¡»Ý¨D 16GB
µêÀÀ¸Ë¸m³W®æ
®Ä¯à ¤º§t 500Mbps ¬y¶qÀˬd±ÂÅv
IPS ¦P®É³s½u 1,000,000
¨C¬í·s³s½u ³Ì°ª¹F 120K (VMware)
³Ì°ª¹F 60K (KVM)
ºô¬q¼Æ¶q 1
µêÀÀ¤À¬q¼Æ¶q µL­­¨î
ºÞ²z³s±µ°ð ¦³
ºÞ²z³s±µ°ð ¦³


THREAT PROTECTION SYSTEM §Þ³N³W®æ

  • ¥\¯à
Threat Protection System 440T TPNN0002 Threat Protection System 2200T TPNN0005
IPS ¬y¶qÀˬd§]¦R¶q 500Mps ¥i¤É¯Å¦Ü 1Gbps 1 Gbps ¥i¤É¯Å¦Ü 2 Gbps
SSL ¬y¶qÀˬd µL ¦³
©µ¿ð <100 ·L¬í <100 ·L¬í
¦w¥þÀô¹Ò (Security Context) 750,000 2,500,00
¦P®É§@·~¶¥¬q 7,500,000 10,000,000
¨C¬í·s³s½u 70,000 115,000
¾÷¨­³W®æ 1U 2U
­«¶q 15.28 ­^½S (6.93 ¤½¤ç) 26.26 ­^½S (11.91 ¤½¤ç)
¤Ø¤o (¼ex²`x°ª) 16.78 ­^¦T(¼e) x 17.3 ­^¦T(²`) x 1.72 ­^¦T(°ª)
42.62 ¤½¤À x 45.00 ¤½¤À x 4.40 ¤½¤À
16.77 ­^¦T (¼e) x 18.70 ­^¦T(²`) x 3.46 ­^¦T(°ª)
42.60 ¤½¤À x 47.50 ¤½¤À x 8.80 ¤½¤À
ºÞ²z³s±µ°ð ¤@­ÓÀW¥~ 10/100/1000 RJ-45
¤@­Ó RJ-45 §Ç¦C°ð¥D±±¥x
ºÞ²z¤¶­±¡GSecurity Management System (SMS)¡BLSM HTTPS ºô­¶¤¶­±¡B«ü¥O¦C¡BTippingPoint MIB
ºô¸ô³s½u ¤K­Ó 10/100/1000 RJ-45 ³s±µ°ð¡A¤º«Øª½³q (Bypass)?
¤ä´©
¤@­Ó 10/100/1000 RJ-45 °ª¥i¥Î©Ê³s±µ°ð
¤K­Ó 10/100/1000 RJ-45 ³s±µ°ð¡A¤º«Øª½³q (Bypass) ¤ä´©
8 x 1G SFP
4 x 10G SFP+
¤@­Ó 10/100/1000 RJ-45 °ª¥i¥Î©Ê³s±µ°ð
¤ä´©¥~³¡ ZPHA (SFP/SFP+)
¤º«ØÀx¦s 8 GB ©TºA¥i§ó´« CFast §Ö°{ºÐ
¹qÀ£ 100-240 VAC¡A50-60 Hz
¹q¬y (³Ì¤j¡A§t¿Äµ·¹q·½) 4-2 A 12-6 A
³Ì¤j¹q¤O®ø¯Ó 250W (853 BTU/hr) 493W (1,682 BTU/hr)
¹q·½¨ÑÀ³¾¹ ³æ¤@©T©w¹q·½¨ÑÀ³¾¹ ¥i¼ö©â´«³Æ´©Âù¹q·½¨ÑÀ³¾¹
§@·~·Å«× 32¢XF ¦Ü 104¢XF (0¢XC ¦Ü 40¢XC)
§@·~¬Û¹ï·Ã«× 5% ¦Ü 95% µL¾®µ²
«D§@·~/Àx¦s·Å«× -4¢XF ¦Ü 158¢XF (-20¢XC ¦Ü 70¢XC)
«D§@·~/Àx¦s¬Û¹ï·Ã«× 5% ¦Ü 95% µL¾®µ²
®ü©Þ°ª«× ³Ì°ª 10,000 ­^§` (3,048 ¤½¤Ø)
¦w¥þ»{ÃÒ UL 60950-1¡BIEC 60950-1
EN 60950-1¡BCSA 22.2 60950-1
²Å¦X RoHS ³W½d
¹qºÏ¬Û®e©Ê (EMC) Class A¡BFCC¡BVCCI¡BKC
EN55022¡BCISPR 22¡BEN55024
CISPR 24¡BEN61000-3-2
EN61000-3-3¡BCE ¼Ð»x


2200T THREAT PROTECTION SYSTEM SSL ¥\¯à

  • ¥\¯à
2200T
IPS ¬y¶qÀˬd§]¦R¶q
1 Gbps / 2 Gbps
IPS + SSL §]¦R¶q
500Mbps + 500Mbps (1 Gbps ±ÂÅv) ©Î
1.5Gbps + 500Mbps ( 2Gbps ±ÂÅv)
SSL ¨C¬í·s³s½u 2,000
SSL ¦P®É§@·~¶¥¬q
70,000
¥­§¡¬G»Ù¶¡¹j (MTBF)
34,837 ¤p®É ( 25¢J Àô¹Ò)
©µ¿ð
<100 ·L¬í
¦w¥þÀô¹Ò (Security Context) 2,500,000
¦P®É§@·~¶¥¬q
10,000,000
¨C¬í·s³s½u
115,000
¾÷¨­³W®æ
2U
­«¶q
26.26 ¤½¤ç (11.91 ­^½S)
¤Ø¤o (¼ex²`x°ª)
16.77 ­^¦T x 18.7 ­^¦T x 3.46 ­^¦T
42.60 ¤½¤À x 47.50 ¤½¤À x 8.80 ¤½¤À
ºÞ²z³s±µ°ð
¤@­ÓÀW¥~ 10/100/1000 RJ-45
¤@­Ó RJ-45 §Ç¦C°ð¥D±±¥x
ºÞ²z¤¶­±
Security Management System(SMS)¡FLocal Security Manager (LSM)¡F
«ü¥O¦C¤¶­± (CLI)
ºô¸ô³s½u
¤K­Ó 10/100/1000 RJ-45 ³s±µ°ð¡A¤º«Øª½³q (Bypass) ¤ä´©¡B
¤K­Ó 1G SFP¡B¥|­Ó 10G SFP+¡B¤ä´©¥~³¡ ZPHA (SFP/SFP+)
¤º«ØÀx¦s
8 GB ©TºA¥i§ó´« CFast §Ö°{ºÐ
¹qÀ£
110-240 VAC¡A50-60 Hz
¹q¬y (³Ì¤j¡A§t¿Äµ·¹q·½)
12-6 A
¹q¤O®ø¯Ó
493W (1,682 BTU/hr)
¹q·½¨ÑÀ³¾¹
¥i¼ö©â´«³Æ´©Âù¹q·½¨ÑÀ³¾¹
§@·~·Å«×
32¢XF ¦Ü 104¢XF (0¢XC ¦Ü 40¢XC)
§@·~¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
«D§@·~/Àx¦s
·Å«×
-4¢XF ¦Ü 158¢XF (-20¢XC ¦Ü 70¢XC)
«D§@·~/Àx¦s
¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
®ü©Þ°ª«×
³Ì°ª 10,000 ­^§` (3,048 ¤½¤Ø)
¦w¥þ»{ÃÒ
UL 60950-1¡BIEC 60950-1¡BEN 60950-1¡BCSA 22.2 60950-1
²Å¦X RoHS ³W½d
¹qºÏ¬Û®e©Ê (EMC)
Class A¡BFCC¡BVCCI¡BKC¡BEN55022¡BCISPR 22¡BEN55024
CISPR 24¡BEN61000-3-2¡BEN61000-3-3¡BCE ¼Ð»x


TPS440T §Þ³N³W®æ

  • ¥\¯à
440T
IPS ¬y¶qÀˬd§]¦R¶q
250 Mbps / 500 Mbps / 1Gbps
©µ¿ð
<100 ·L¬í
¦w¥þÀô¹Ò (Security Context)
750,000
¦P®É§@·~¶¥¬q
1,000,000
¥­§¡¬G»Ù¶¡¹j (MTBF)
39,694 ¤p®É ( 25¢J Àô¹Ò)
¨C¬í·s³s½u
70,000
¾÷¨­³W®æ
1U
­«¶q
15.28 ­^½S (6.93 ¤½¤ç)
¤Ø¤o (¼ex²`x°ª)
16.78 ­^¦T (¼e) x 17.72 ­^¦T (²`) x 1.73 ­^¦T (°ª)
42.62 ¤½¤À x 45.00 ¤½¤À x 4.40 ¤½¤À
ºÞ²z³s±µ°ð
¤@­ÓÀW¥~(out-of-band) 10/100/1000 RJ-45¡B¤@­Ó RJ-45 §Ç¦C°ð¥D±±¥x
ºÞ²z¤¶­±¡GSecurity Management System (SMS)¡BLSM HTTPS ºô­¶
¤¶­±¡B«ü¥O¦C
ºÞ²z¤¶­±
Security Management System (SMS)¡BLSM HTTPS ºô­¶¤¶­±¡B
«ü¥O¦C
ºô¸ô³s½u
¤K­Ó 10/100/1000 RJ-45 ³s±µ°ð¡A¤º«Øª½³q (Bypass) ¤ä´©
¤@­Ó 10/100/1000 RJ-45 °ª¥i¥Î©Ê³s±µ°ð
¤º«ØÀx¦s
8 GB ©TºA¥i§ó´« CFast §Ö°{ºÐ
¹qÀ£
100-240 VAC
¹q¬y (³Ì¤j¡A§t¿Äµ·¹q·½)
4-2 A
³Ì¤j¹q¤O®ø¯Ó
250W (853 BTU/hr)
¹q·½¨ÑÀ³¾¹
³æ¤@©T©w¹q·½¨ÑÀ³¾¹
§@·~·Å«×
32¢XF ¦Ü 104¢XF (0¢XC ¦Ü 40¢XC)
§@·~¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
«D§@·~/Àx¦s
·Å«×
-4¢XF ¦Ü 158¢XF (-20¢XC ¦Ü 70¢XC)
«D§@·~/Àx¦s
¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
¦w¥þ»{ÃÒ
UL 60950-1¡BIEC 60950-1¡BEN 60950-1¡BCSA 22.2 60950-1
²Å¦X RoHS ³W½d
¹qºÏ¬Û®e©Ê (EMC)
Class A¡BFCC¡BVCCI¡BKC¡BEN55022¡BCISPR 22¡BEN55024
CISPR 24¡BEN61000-3-2¡BEN61000-3-3¡BCE ¼Ð»x

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºTrendMicroÁÍ¶Õ - TrendMicroÁÍ¶Õ TippingPoint Threat Protection System - ¨¾¬r¦w¥þ³nÅé> ,³Ì¦nªºTrendMicroÁÍ¶Õ - TrendMicroÁÍ¶Õ TippingPoint Threat Protection System±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 ¨¾¤õÀð
 ¨¾¬r
 ¬¡°ÊºÊ±±
 ÁͶÕ
 ÁɪùÅK§J
 McAfee
 SOPHOS
 NOD32
 ¥d¤Ú´µ°ò
 Panda
 eTrust
 ¦¿¥Á
 bullguard
 BitDefender
 G DATA
 IP-Scan
 Norman
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > ¨¾¬r¦w¥þ³nÅé>ÁͶÕ


TrendMicroÁͶÕTrendMicroÁÍ¶Õ TippingPoint Threat Protection System

TrendMicroÁÍ¶Õ TippingPoint Threat Protection System


¼tµP¡GTrendMicroÁÍ¶Õ      >>ÂsÄýTrendMicroÁͶեþ³¡²£«~
«¬¸¹¡GTrendMicroÁÍ¶Õ TippingPoint Threat Protection System



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºTrendMicroÁÍ¶Õ - TrendMicroÁÍ¶Õ TippingPoint Threat Protection System - ¨¾¬r¦w¥þ³nÅé> ,³Ì¦nªºTrendMicroÁÍ¶Õ - TrendMicroÁÍ¶Õ TippingPoint Threat Protection System±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Ú¨¾¬r¦w¥þ³nÅé>ÁÍ¶Õ Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óTrendMicroÁͶլÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§TrendMicroÁͶղ£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§TrendMicroÁͶխì¼t°t¥ó


¡@

¡@

¡@


TrendMicroÁͶÕ
TrendMicroÁÍ¶Õ TippingPoint Threat Protection System - ServerBank¸ê°T±ÄÁʺô
TrendMicroÁÍ¶Õ TippingPoint Threat Protection System
¨¾¬r¦w¥þ³nÅé>ÁͶÕ


¡@
²£«~³W®æ

8200TX §Þ³N³W®æ
¥\¯à
8200TX
¬y¶qÀˬd§]¦R¶q
3/5/10/15/20/30/40 Gbps
SSL ¬y¶qÀˬd§]¦R¶q
2Gbps (2K ª÷Æ_ SHA256)
SSL ¨C¬í·s³s½u¶¥¬q
5,000
SSL ¬y¶qÀˬd¦P®É§@·~¶¥¬q
100,000
¥­§¡¬G»Ù¶¡¹j (MTBF)
88,706 ¤p®É ( 25¢J Àô¹Ò)
©µ¿ð
<40 ·L¬í
¦w¥þÀô¹Ò (Security Context)
10,000,000
¦P®É§@·~¶¥¬q
120,000,000
¨C¬í·s³s½u
650,000
¾÷¨­³W®æ
1U
­«¶q
32 ­^½S (³Ì¤j¡A§t I/O ¼Ò²Õ)
29 ­^½S (§tªÅ¥Õ I/O ¼Ò²Õ)
¤Ø¤o (¼ex²`x°ª)
428mm (18.54 ¦T) ¼e x 631mm (24.84 ¦T) ²` x 44mm (1.73 ¦T) °ª
ºÞ²z³s±µ°ð
RJ45 ºÞ²z¥D±±¥x³s±µ°ð (115200 8N1)
RJ45 1GbE (10/100/1000 Mbps) ºÞ²zºô¸ô³s±µ°ð
ºÞ²z¤¶­±
Security Management System(SMS)¡FLocal Security Manager
(LSM)¡F
«ü¥O¦C¤¶­± (CLI)
ºô¸ô³s½u
2 ­Ó I/O ¼Ò²Õ´¡¼Ñ¡A¥i²V´¡¡G
6-Segment 1GE »É½u I/O ¼Ò²Õ
6-Segment 1GE SFP I/O ¼Ò²Õ
4-Segment 10GE SFP+ I/O ¼Ò²Õ
1-Segment 40GE QSFP+ I/O ¼Ò²Õ
4-Segment 1GE »É½uª½³q (Bypass) I/O ¼Ò²Õ
2-Segment 1GE SR/LR ¥úÅÖª½³q (Bypass) I/O ¼Ò²Õ
2-Segment 10GE SR/LR ¥úÅÖª½³q (Bypass) I/O ¼Ò²Õ
¤º«ØÀx¦s
32GB ¤º«Ø CFAST («È¤áµLªk¦Û¦æ§ó´«) / 32GB ¥~³¡1.8 ¦T SSD
¹qÀ£
100 ¦Ü 240 VAC / -40 ¦Ü -60 VDC
¹q¬y (³Ì¤j¡A§t¿Äµ·¹q·½)
12/6 Amps AC¡B24/16 Amps DC
¹q·½¨ÑÀ³¾¹
Âù/³Æ´© 750W ¹q·½¨ÑÀ³¾¹
§@·~·Å«×
32¢XF ¦Ü 104¢XF (0¢XC ¦Ü 40¢XC)
§@·~¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
«D§@·~/Àx¦s·Å«×
-4¢XF ¦Ü 158¢XF (-20¢XC ¦Ü 70¢XC)
«D§@·~/Àx¦s¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
®ü©Þ°ª«×
³Ì°ª 10,000 ­^§` (3,048 ¤½¤Ø)
¦w¥þ»{ÃÒ
UL 60950-1¡BIEC 60950-1¡BEN 60950-1¡BCSA 22.2 60950-1
²Å¦X RoHS ³W½d
¹qºÏ¬Û®e©Ê (EMC)
Class A¡BFCC¡BVCCI¡BKC¡BEN55022¡BCISPR 22¡BEN55024 CISPR 24¡BEN61000-3-
2¡BEN61000-3-3¡BCE ¼Ð»x


8400TX §Þ³N³W®æ
¥\¯à
8400TX
IPS ¬y¶qÀˬd§]¦R¶q
3/5/10/15/20/30/40 Gbps
SSL ¬y¶qÀˬd§]¦R¶q
2Gbps (2K ª÷Æ_ SHA256)
SSL ¬y¶qÀˬd¦P®É³s½u
100,000
SSL ¨C¬í·s³s½u¶¥¬q
5,000
©µ¿ð
<40 ·L¬í
¥­§¡¬G»Ù¶¡¹j (MTBF)
88,706 ¤p®É ( 25¢J Àô¹Ò)
¦w¥þÀô¹Ò (Security Context)
10,000,000
¦P®É§@·~¶¥¬q
120,000,000
¨C¬í³s½u
650,000
¾÷¨­³W®æ
2U
­«¶q
50 ­^½S (³Ì¤j¡A§t I/O ¼Ò²Õ)
41.5 ­^½S (§tªÅ¥Õ I/O ¼Ò²Õ)
¤Ø¤o 1U (¼ex²`x°ª)
428mm (18.54 ¦T) ¼e x 631mm (24.84 ¦T) ²` x 88mm (3.46 ¦T) °ª
ºÞ²z³s±µ°ð
RJ45 ºÞ²z¥D±±¥x³s±µ°ð (115200 8N1)
RJ45 1GbE (10/100/1000 Mbps) ºÞ²zºô¸ô³s±µ°ð
ºÞ²z¤¶­±
Security Management System(SMS)¡FLocal Security Manager (LSM)¡F
«ü¥O¦C¤¶­± (CLI)
ºô¸ô³s½u
4 ­Ó I/O ¼Ò²Õ´¡¼Ñ¡A¥i²V´¡¡G
6-Segment 1GE »É½u I/O ¼Ò²Õ
6-Segment 1GE SFP I/O ¼Ò²Õ
4-Segment 10GE SFP+ I/O ¼Ò²Õ
1-Segment 40GE QSFP+ I/O ¼Ò²Õ
4-Segment 1GE »É½uª½³q (Bypass) I/O ¼Ò²Õ
2-Segment 1GE SR/LR ¥úÅÖª½³q (Bypass) I/O ¼Ò²Õ
2-Segment 10GE SR/LR ¥úÅÖª½³q (Bypass) I/O ¼Ò²Õ
¤º«ØÀx¦s
32GB ¤º«Ø CFAST («È¤áµLªk¦Û¦æ§ó´«) / 32GB ¥~³¡1.8 ¦T SSD
¹qÀ£
100 ¦Ü 240 VAC / -40 ¦Ü -60 VDC
¹q¬y (³Ì¤j¡A§t¿Äµ·¹q·½)
12/6 Amps AC¡B24/16 Amps DC
¹q·½¨ÑÀ³¾¹
Âù/³Æ´© 750W ¹q·½¨ÑÀ³¾¹
§@·~·Å«×
32¢XF ¦Ü 104¢XF (0¢XC ¦Ü 40¢XC)
§@·~¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
«D§@·~/Àx¦s·Å«×
-4¢XF ¦Ü 158¢XF (-20¢XC ¦Ü 70¢XC)
«D§@·~/Àx¦s¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
®ü©Þ°ª«×
³Ì°ª 10,000 ­^§` (3,048 ¤½¤Ø)
¦w¥þ»{ÃÒ
UL 60950-1¡BIEC 60950-1¡B
EN 60950-1¡BCSA 22.2 60950-1
²Å¦X RoHS ³W½d
¹qºÏ¬Û®e©Ê (EMC)
Class A¡BFCC¡BVCCI¡BKC¡BEN55022¡BCISPR 22¡B
EN55024 CISPR 24¡BEN61000-3-2¡B
EN61000-3-3¡BCE ¼Ð»x


T ¨t¦C§Þ³N³W®æ

VIRTUAL THREAT PROTECTION SYSTEM

  • ¥\¯à
TippingPoint Standard Virtual vTPS Appliance
? VMWare ESXi 5.5¡B6.0
? KVM ¡V Redhat Enterprise Linux 6¡B7
ºô¸ôÅX°Êµ{¦¡ VMWare ¡V VMXNet3
? KVM ¡V virtIO
ÅÞ¿è®Ö¤ß¼Æ¶q 3 ©Î 4
°O¾ÐÅé»Ý¨D 8 GB
µwºÐªÅ¶¡»Ý¨D 16GB
µêÀÀ¸Ë¸m³W®æ
®Ä¯à ¤º§t 500Mbps ¬y¶qÀˬd±ÂÅv
IPS ¦P®É³s½u 1,000,000
¨C¬í·s³s½u ³Ì°ª¹F 120K (VMware)
³Ì°ª¹F 60K (KVM)
ºô¬q¼Æ¶q 1
µêÀÀ¤À¬q¼Æ¶q µL­­¨î
ºÞ²z³s±µ°ð ¦³
ºÞ²z³s±µ°ð ¦³


THREAT PROTECTION SYSTEM §Þ³N³W®æ

  • ¥\¯à
Threat Protection System 440T TPNN0002 Threat Protection System 2200T TPNN0005
IPS ¬y¶qÀˬd§]¦R¶q 500Mps ¥i¤É¯Å¦Ü 1Gbps 1 Gbps ¥i¤É¯Å¦Ü 2 Gbps
SSL ¬y¶qÀˬd µL ¦³
©µ¿ð <100 ·L¬í <100 ·L¬í
¦w¥þÀô¹Ò (Security Context) 750,000 2,500,00
¦P®É§@·~¶¥¬q 7,500,000 10,000,000
¨C¬í·s³s½u 70,000 115,000
¾÷¨­³W®æ 1U 2U
­«¶q 15.28 ­^½S (6.93 ¤½¤ç) 26.26 ­^½S (11.91 ¤½¤ç)
¤Ø¤o (¼ex²`x°ª) 16.78 ­^¦T(¼e) x 17.3 ­^¦T(²`) x 1.72 ­^¦T(°ª)
42.62 ¤½¤À x 45.00 ¤½¤À x 4.40 ¤½¤À
16.77 ­^¦T (¼e) x 18.70 ­^¦T(²`) x 3.46 ­^¦T(°ª)
42.60 ¤½¤À x 47.50 ¤½¤À x 8.80 ¤½¤À
ºÞ²z³s±µ°ð ¤@­ÓÀW¥~ 10/100/1000 RJ-45
¤@­Ó RJ-45 §Ç¦C°ð¥D±±¥x
ºÞ²z¤¶­±¡GSecurity Management System (SMS)¡BLSM HTTPS ºô­¶¤¶­±¡B«ü¥O¦C¡BTippingPoint MIB
ºô¸ô³s½u ¤K­Ó 10/100/1000 RJ-45 ³s±µ°ð¡A¤º«Øª½³q (Bypass)?
¤ä´©
¤@­Ó 10/100/1000 RJ-45 °ª¥i¥Î©Ê³s±µ°ð
¤K­Ó 10/100/1000 RJ-45 ³s±µ°ð¡A¤º«Øª½³q (Bypass) ¤ä´©
8 x 1G SFP
4 x 10G SFP+
¤@­Ó 10/100/1000 RJ-45 °ª¥i¥Î©Ê³s±µ°ð
¤ä´©¥~³¡ ZPHA (SFP/SFP+)
¤º«ØÀx¦s 8 GB ©TºA¥i§ó´« CFast §Ö°{ºÐ
¹qÀ£ 100-240 VAC¡A50-60 Hz
¹q¬y (³Ì¤j¡A§t¿Äµ·¹q·½) 4-2 A 12-6 A
³Ì¤j¹q¤O®ø¯Ó 250W (853 BTU/hr) 493W (1,682 BTU/hr)
¹q·½¨ÑÀ³¾¹ ³æ¤@©T©w¹q·½¨ÑÀ³¾¹ ¥i¼ö©â´«³Æ´©Âù¹q·½¨ÑÀ³¾¹
§@·~·Å«× 32¢XF ¦Ü 104¢XF (0¢XC ¦Ü 40¢XC)
§@·~¬Û¹ï·Ã«× 5% ¦Ü 95% µL¾®µ²
«D§@·~/Àx¦s·Å«× -4¢XF ¦Ü 158¢XF (-20¢XC ¦Ü 70¢XC)
«D§@·~/Àx¦s¬Û¹ï·Ã«× 5% ¦Ü 95% µL¾®µ²
®ü©Þ°ª«× ³Ì°ª 10,000 ­^§` (3,048 ¤½¤Ø)
¦w¥þ»{ÃÒ UL 60950-1¡BIEC 60950-1
EN 60950-1¡BCSA 22.2 60950-1
²Å¦X RoHS ³W½d
¹qºÏ¬Û®e©Ê (EMC) Class A¡BFCC¡BVCCI¡BKC
EN55022¡BCISPR 22¡BEN55024
CISPR 24¡BEN61000-3-2
EN61000-3-3¡BCE ¼Ð»x


2200T THREAT PROTECTION SYSTEM SSL ¥\¯à

  • ¥\¯à
2200T
IPS ¬y¶qÀˬd§]¦R¶q
1 Gbps / 2 Gbps
IPS + SSL §]¦R¶q
500Mbps + 500Mbps (1 Gbps ±ÂÅv) ©Î
1.5Gbps + 500Mbps ( 2Gbps ±ÂÅv)
SSL ¨C¬í·s³s½u 2,000
SSL ¦P®É§@·~¶¥¬q
70,000
¥­§¡¬G»Ù¶¡¹j (MTBF)
34,837 ¤p®É ( 25¢J Àô¹Ò)
©µ¿ð
<100 ·L¬í
¦w¥þÀô¹Ò (Security Context) 2,500,000
¦P®É§@·~¶¥¬q
10,000,000
¨C¬í·s³s½u
115,000
¾÷¨­³W®æ
2U
­«¶q
26.26 ¤½¤ç (11.91 ­^½S)
¤Ø¤o (¼ex²`x°ª)
16.77 ­^¦T x 18.7 ­^¦T x 3.46 ­^¦T
42.60 ¤½¤À x 47.50 ¤½¤À x 8.80 ¤½¤À
ºÞ²z³s±µ°ð
¤@­ÓÀW¥~ 10/100/1000 RJ-45
¤@­Ó RJ-45 §Ç¦C°ð¥D±±¥x
ºÞ²z¤¶­±
Security Management System(SMS)¡FLocal Security Manager (LSM)¡F
«ü¥O¦C¤¶­± (CLI)
ºô¸ô³s½u
¤K­Ó 10/100/1000 RJ-45 ³s±µ°ð¡A¤º«Øª½³q (Bypass) ¤ä´©¡B
¤K­Ó 1G SFP¡B¥|­Ó 10G SFP+¡B¤ä´©¥~³¡ ZPHA (SFP/SFP+)
¤º«ØÀx¦s
8 GB ©TºA¥i§ó´« CFast §Ö°{ºÐ
¹qÀ£
110-240 VAC¡A50-60 Hz
¹q¬y (³Ì¤j¡A§t¿Äµ·¹q·½)
12-6 A
¹q¤O®ø¯Ó
493W (1,682 BTU/hr)
¹q·½¨ÑÀ³¾¹
¥i¼ö©â´«³Æ´©Âù¹q·½¨ÑÀ³¾¹
§@·~·Å«×
32¢XF ¦Ü 104¢XF (0¢XC ¦Ü 40¢XC)
§@·~¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
«D§@·~/Àx¦s
·Å«×
-4¢XF ¦Ü 158¢XF (-20¢XC ¦Ü 70¢XC)
«D§@·~/Àx¦s
¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
®ü©Þ°ª«×
³Ì°ª 10,000 ­^§` (3,048 ¤½¤Ø)
¦w¥þ»{ÃÒ
UL 60950-1¡BIEC 60950-1¡BEN 60950-1¡BCSA 22.2 60950-1
²Å¦X RoHS ³W½d
¹qºÏ¬Û®e©Ê (EMC)
Class A¡BFCC¡BVCCI¡BKC¡BEN55022¡BCISPR 22¡BEN55024
CISPR 24¡BEN61000-3-2¡BEN61000-3-3¡BCE ¼Ð»x


TPS440T §Þ³N³W®æ

  • ¥\¯à
440T
IPS ¬y¶qÀˬd§]¦R¶q
250 Mbps / 500 Mbps / 1Gbps
©µ¿ð
<100 ·L¬í
¦w¥þÀô¹Ò (Security Context)
750,000
¦P®É§@·~¶¥¬q
1,000,000
¥­§¡¬G»Ù¶¡¹j (MTBF)
39,694 ¤p®É ( 25¢J Àô¹Ò)
¨C¬í·s³s½u
70,000
¾÷¨­³W®æ
1U
­«¶q
15.28 ­^½S (6.93 ¤½¤ç)
¤Ø¤o (¼ex²`x°ª)
16.78 ­^¦T (¼e) x 17.72 ­^¦T (²`) x 1.73 ­^¦T (°ª)
42.62 ¤½¤À x 45.00 ¤½¤À x 4.40 ¤½¤À
ºÞ²z³s±µ°ð
¤@­ÓÀW¥~(out-of-band) 10/100/1000 RJ-45¡B¤@­Ó RJ-45 §Ç¦C°ð¥D±±¥x
ºÞ²z¤¶­±¡GSecurity Management System (SMS)¡BLSM HTTPS ºô­¶
¤¶­±¡B«ü¥O¦C
ºÞ²z¤¶­±
Security Management System (SMS)¡BLSM HTTPS ºô­¶¤¶­±¡B
«ü¥O¦C
ºô¸ô³s½u
¤K­Ó 10/100/1000 RJ-45 ³s±µ°ð¡A¤º«Øª½³q (Bypass) ¤ä´©
¤@­Ó 10/100/1000 RJ-45 °ª¥i¥Î©Ê³s±µ°ð
¤º«ØÀx¦s
8 GB ©TºA¥i§ó´« CFast §Ö°{ºÐ
¹qÀ£
100-240 VAC
¹q¬y (³Ì¤j¡A§t¿Äµ·¹q·½)
4-2 A
³Ì¤j¹q¤O®ø¯Ó
250W (853 BTU/hr)
¹q·½¨ÑÀ³¾¹
³æ¤@©T©w¹q·½¨ÑÀ³¾¹
§@·~·Å«×
32¢XF ¦Ü 104¢XF (0¢XC ¦Ü 40¢XC)
§@·~¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
«D§@·~/Àx¦s
·Å«×
-4¢XF ¦Ü 158¢XF (-20¢XC ¦Ü 70¢XC)
«D§@·~/Àx¦s
¬Û¹ï·Ã«×
5% ¦Ü 95% µL¾®µ²
¦w¥þ»{ÃÒ
UL 60950-1¡BIEC 60950-1¡BEN 60950-1¡BCSA 22.2 60950-1
²Å¦X RoHS ³W½d
¹qºÏ¬Û®e©Ê (EMC)
Class A¡BFCC¡BVCCI¡BKC¡BEN55022¡BCISPR 22¡BEN55024
CISPR 24¡BEN61000-3-2¡BEN61000-3-3¡BCE ¼Ð»x

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºTrendMicroÁÍ¶Õ - TrendMicroÁÍ¶Õ TippingPoint Threat Protection System - ¨¾¬r¦w¥þ³nÅé> ,³Ì¦nªºTrendMicroÁÍ¶Õ - TrendMicroÁÍ¶Õ TippingPoint Threat Protection System±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@