­º­¶> Àx¦s³]³Æ/³Æ¥÷¤è®×

>>ÂsÄý©Ò¦³SunÀx¦s³]³Æ/³Æ¥÷¤è®×

Sun
StorEdge 3511 (500GB * 5, 1 RAID)

«¬¸¹¡GXTA3511R01A1A2500


SunXTA3511R01A1A2500


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºSun - XTA3511R01A1A2500 - Àx¦s³]³Æ/³Æ¥÷¤è®×
³Ì¦nªºSun - StorEdge 3511 (500GB * 5, 1 RAID)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óSun¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§Sun²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§Sun­ì¼t°t¥ó


¡@

¡@

¡@


Sun
StorEdge 3511 (500GB * 5, 1 RAID) - ServerBank¸ê°T±ÄÁʺô
XTA3511R01A1A2500
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ
Standard Interfaces
Host interface 2 Gb Fibre Channel

Drives 3.5 in. low profile

Supported drives Dual-ported 1.5 Gb/s Serial ATA with active-active loops, 250 GB, 500 GB 7200 rpm SATA

Maximum number of host ports Dual RAID controllers: 12x2 Gb Fibre Channel host ports (no expansion); 6x2 Gb Fibre Channel with expansion trays

Maximum cable length 250 m
Tray (12 HDDs) and RAID Array (108 HDDs) Maximum Raw Storage Capacities
250GB 7200rpm HDDs 3TB per 2U tray; expandable to 18TB per RAID array

500GB 7200rpm HDDs 6TB per 2U tray; expandable to 54TB per RAID array
RAID Controller Card
RAID configurations Expansion (no controller); single RAID controller; dual (mirrored) RAID controllers

RAID levels 0, 1, 1+0, 3, 5, 3+0, and 5+0

Max. LUNS Up to 1,024 per RAID array

Max. LUN sizes and max. number of logical drives Firmware 4.11 and below: Max. 2TB LUN size; 8 logical drives max.

Firmware 4.11 and above: Max. 16TB LUN size; 32 logical drives max.


Max. local and/or global hot spares Up to 20 (RAID set and disk quantity dependent) per RAID array

Cache size (read and write) 1GB per controller

Cache battery backup Up to 72 hours

Cache write policy Write Back¡Xdefault; Write Through¡Xuser configurable

Cache selectable block sizes 32K (random file transfer); 128K (sequential file transfer)

Included Management software Sun StorEdge Configuration Service software; Sun StorEdge support Diagnostic Reporter software

Optional supported software Sun StorEdge Enterprise Storage Manager, Sun StorEdge Traffic Manager, Sun Cluster 3, VERITAS NetBackup and VERITAS Volume Manager including DMP, Sun Logical Volume Manager for the Solaris 9 Operating System, Sun Solstice DiskSuite for the Solaris 8 Operating System, Sun StorEdge Resource Management, Sun StorEdge Utilization, and Sun StorEdge Performance Suites
Supported Host Platforms
Supported Host Servers All Sun Enterprise, Netra, and Sun Fire SPARC-based and Sun Fire x86-based servers; x86-based (Intel and AMD) third-party servers; IBM RISC-based servers; HP RISC-based servers

Supported host bus adapters
  • Sun Solaris Operating Systems 8, 9, 10 (SPARC-based): X6727A, X6767A, X6768A, SG-XPCI1FC-QF2, SG-XPCI2FC-QF2, SG-XPCI1FC-JF2, SG-XPCI2FC-JF2
  • Sun Solaris x86 10: X9279A (Sun Fire V20Z and V40z servers)
  • Red Hat Linux, Enterprise Edition, 32b 64b; Novell SuSE Linux Enterprise server 8; Novell SuSE Linux 9: QLA23XX 2Gb FC PCI*
  • MS Windows NT EE 4.0/2000/2003 server/Novell NetWare 5.1, 6.0, 6.5: QLA23XX 2Gb FC PCI*
  • HP-UX 11.0 and 11i: Emulex LP9XXX 2Gb FC PCI* and compatible
  • IBM-AIX 4.3.3 and 5.1L (32 and 64 bit): Emulex LP9XXX 2Gb FC PCI* and compatible
*Note: All non-Sun host bus adapters supported by third-party vendor
Reliability, Availability, Serviceability (RAS)
RAS
  • Non-disruptive controller firmware upgrades using dual RAID controllers via SSCS
  • Hot-swap RAID controllers with battery-backed mirrored 1GB cache, (with dual RAID controllers)
  • Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
  • Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
  • Hot-swap, redundant electrically-isolated redundant cooling fans
  • Local and global hot sparing
Electrical Requirements
Wattage 420W each (Dual Hot-Swap Redundant Power Supplies)

AC Voltage 100 to 240 VAC, single phase

AC Power requirement 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)

AC Current per input 100 to 240 VAC, 50 to 60 Hz, 5.0¡V7.1A

DC Voltage ¡V48 or ¡V60 VDC, 18A

DC Power requirement ¡V36 to ¡V75 VDC

DC Current per input ¡V48 or ¡V60 VDC, 18A
Environment
Temperature
  • Operating: 5¢XC to 40¢XC (41¢XF to 104¢XF)
  • Nonoperating: ¡V40¢XC to 65¢XC (¡V40¢XF to 149¢XF)

Humidity (non-condensing)
  • Operating: 10% to 90% relative to 38¢XC
  • Nonoperating: 0% to 90% relative to 27¢XC

Altitude
  • Operating: ¡V30m to 3048m(¡V100 to 10,000 ft.)
  • Nonoperating: ¡V30m to 12,192m(¡V100 to 40,000 ft.)

Shock
  • Operating: 5.0 G, 11-ms, half-sine
  • Nonoperating: 15.0 G, 11-ms, half-sine

Vibration
  • Operating: 0.2 G, 5¡V500 Hz, swept-sine
  • Nonoperating: 1.0 G, 5¡V500 Hz, swept-sine

Noise *
  • Operating: LWAD = 6.6 bels
  • Nonoperating: LWAD = 6.6 bels
*LWAD (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23¢XC.
Regulations - Meets or exceeds the following requirements:
Safety UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003

Emissions VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark

Harmonics IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001

Immunity CSIPR 24 EN 55024

Ruggedized NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386

Restriction of Hazardous Substances Expanion trays compliant under spare parts exemption only.
Dimensions and Weight
Dimensions (Height, Width, Depth) H: 8.8 cm (3.5 in.; 2U); W: 44.7 cm (17.6 in.); D: 54.5 cm (21.5 in.)

Weight (Fully Populated) 26.8 kg (59.1 lb.)
Warranty
Two year Sun two-year standard warranty, (1st year on site, 2nd year return to depot)

Service upgrades SunSpectrum service upgrades are available

¡@


¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºSun - XTA3511R01A1A2500 - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºSun - StorEdge 3511 (500GB * 5, 1 RAID)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 NASºô¸ôÀx¦sÀɮצøªA¾¹
 ServerBank±ÀÂ˾÷ºØ
 ®à¤W«¬
 ¾÷¬[¦¡
 ª½¥ß¦¡
 ºÏºÐ°}¦C°t¥ó
 ¦Û°Ê¥úºÐ«þ¨©¾÷
 ¥~±µ¦¡µwºÐ
 ºÏ±a¾÷
 SDLT
 DLT
 LTO 1/2/3/4
 Ultrium I
 Ultrium II
 SAIT
 AIT
 AIT Turbo
 DAT
 DDS
 ºÏ±a´«±a¾÷Autoloader
 iSCSI¸Ñ¨M¤è®×
 iSCSIºÏºÐ°}¦C
 iSCSI¾ô±µ¾¹
 ºÏºÐ°}¦CRAID
 ServerBank±ÀÂ˾÷ºØ
 iSCSI
 iSCSI to SAS
 SATA
 SCSI-to-SCSI
 SCSI-to-IDE
 SCSI-to-SATA
 Fibre-to-SCSI
 Fibre-to-IDE
 Fibre-to-SATA
 Fibre-to-Fibre
 Fibre to SAS
 USB-to-IDE
 SATA-to-SATA
 SATA-to-IDE
 SAS
 IDE-to-IDE
 1394-to-IDE
 JBOD
 ºÏºÐ°}¦CÂd
 1394B-to-SATAII
 1394B-to PATA
 °ïÅ|¦¡Àx¦s¥~±µ²°
 SAS-to-SATA
 SAS-to-SAS
 SCSI-to-SAS
 PCIE
 USB
 IDE
 SAN¸Ñ¨M¤è®×
 ¥úÅÖ³q¹D¥æ´«¾¹
 ¥úÅÖ³q¹D¤¶­±¥d
 SAN Storage
 SAN Software
 ¥úÅÖ³q¹D¾ô±µ¾¹
 ¾É¦V¾¹director
 ¥úÅÖ¼Ò²Õ
 Àx¦sºÞ²z³nÅé
 ºÏ±aÂd
 ºÏ±a
 ¦Û°Ê´«¤ù¥úºÐ
 ÂÅ¥ú¥úºÐÂd
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > Àx¦s³]³Æ/³Æ¥÷¤è®×


SunXTA3511R01A1A2500

StorEdge 3511 (500GB * 5, 1 RAID)


¼tµP¡GSun      >>ÂsÄýSun¥þ³¡²£«~
«¬¸¹¡GXTA3511R01A1A2500



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºSun - XTA3511R01A1A2500 - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºSun - StorEdge 3511 (500GB * 5, 1 RAID)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óSun¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§Sun²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§Sun­ì¼t°t¥ó


¡@

¡@

¡@


Sun
StorEdge 3511 (500GB * 5, 1 RAID) - ServerBank¸ê°T±ÄÁʺô
XTA3511R01A1A2500
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ
Standard Interfaces
Host interface 2 Gb Fibre Channel

Drives 3.5 in. low profile

Supported drives Dual-ported 1.5 Gb/s Serial ATA with active-active loops, 250 GB, 500 GB 7200 rpm SATA

Maximum number of host ports Dual RAID controllers: 12x2 Gb Fibre Channel host ports (no expansion); 6x2 Gb Fibre Channel with expansion trays

Maximum cable length 250 m
Tray (12 HDDs) and RAID Array (108 HDDs) Maximum Raw Storage Capacities
250GB 7200rpm HDDs 3TB per 2U tray; expandable to 18TB per RAID array

500GB 7200rpm HDDs 6TB per 2U tray; expandable to 54TB per RAID array
RAID Controller Card
RAID configurations Expansion (no controller); single RAID controller; dual (mirrored) RAID controllers

RAID levels 0, 1, 1+0, 3, 5, 3+0, and 5+0

Max. LUNS Up to 1,024 per RAID array

Max. LUN sizes and max. number of logical drives Firmware 4.11 and below: Max. 2TB LUN size; 8 logical drives max.

Firmware 4.11 and above: Max. 16TB LUN size; 32 logical drives max.


Max. local and/or global hot spares Up to 20 (RAID set and disk quantity dependent) per RAID array

Cache size (read and write) 1GB per controller

Cache battery backup Up to 72 hours

Cache write policy Write Back¡Xdefault; Write Through¡Xuser configurable

Cache selectable block sizes 32K (random file transfer); 128K (sequential file transfer)

Included Management software Sun StorEdge Configuration Service software; Sun StorEdge support Diagnostic Reporter software

Optional supported software Sun StorEdge Enterprise Storage Manager, Sun StorEdge Traffic Manager, Sun Cluster 3, VERITAS NetBackup and VERITAS Volume Manager including DMP, Sun Logical Volume Manager for the Solaris 9 Operating System, Sun Solstice DiskSuite for the Solaris 8 Operating System, Sun StorEdge Resource Management, Sun StorEdge Utilization, and Sun StorEdge Performance Suites
Supported Host Platforms
Supported Host Servers All Sun Enterprise, Netra, and Sun Fire SPARC-based and Sun Fire x86-based servers; x86-based (Intel and AMD) third-party servers; IBM RISC-based servers; HP RISC-based servers

Supported host bus adapters
  • Sun Solaris Operating Systems 8, 9, 10 (SPARC-based): X6727A, X6767A, X6768A, SG-XPCI1FC-QF2, SG-XPCI2FC-QF2, SG-XPCI1FC-JF2, SG-XPCI2FC-JF2
  • Sun Solaris x86 10: X9279A (Sun Fire V20Z and V40z servers)
  • Red Hat Linux, Enterprise Edition, 32b 64b; Novell SuSE Linux Enterprise server 8; Novell SuSE Linux 9: QLA23XX 2Gb FC PCI*
  • MS Windows NT EE 4.0/2000/2003 server/Novell NetWare 5.1, 6.0, 6.5: QLA23XX 2Gb FC PCI*
  • HP-UX 11.0 and 11i: Emulex LP9XXX 2Gb FC PCI* and compatible
  • IBM-AIX 4.3.3 and 5.1L (32 and 64 bit): Emulex LP9XXX 2Gb FC PCI* and compatible
*Note: All non-Sun host bus adapters supported by third-party vendor
Reliability, Availability, Serviceability (RAS)
RAS
  • Non-disruptive controller firmware upgrades using dual RAID controllers via SSCS
  • Hot-swap RAID controllers with battery-backed mirrored 1GB cache, (with dual RAID controllers)
  • Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
  • Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
  • Hot-swap, redundant electrically-isolated redundant cooling fans
  • Local and global hot sparing
Electrical Requirements
Wattage 420W each (Dual Hot-Swap Redundant Power Supplies)

AC Voltage 100 to 240 VAC, single phase

AC Power requirement 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)

AC Current per input 100 to 240 VAC, 50 to 60 Hz, 5.0¡V7.1A

DC Voltage ¡V48 or ¡V60 VDC, 18A

DC Power requirement ¡V36 to ¡V75 VDC

DC Current per input ¡V48 or ¡V60 VDC, 18A
Environment
Temperature
  • Operating: 5¢XC to 40¢XC (41¢XF to 104¢XF)
  • Nonoperating: ¡V40¢XC to 65¢XC (¡V40¢XF to 149¢XF)

Humidity (non-condensing)
  • Operating: 10% to 90% relative to 38¢XC
  • Nonoperating: 0% to 90% relative to 27¢XC

Altitude
  • Operating: ¡V30m to 3048m(¡V100 to 10,000 ft.)
  • Nonoperating: ¡V30m to 12,192m(¡V100 to 40,000 ft.)

Shock
  • Operating: 5.0 G, 11-ms, half-sine
  • Nonoperating: 15.0 G, 11-ms, half-sine

Vibration
  • Operating: 0.2 G, 5¡V500 Hz, swept-sine
  • Nonoperating: 1.0 G, 5¡V500 Hz, swept-sine

Noise *
  • Operating: LWAD = 6.6 bels
  • Nonoperating: LWAD = 6.6 bels
*LWAD (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23¢XC.
Regulations - Meets or exceeds the following requirements:
Safety UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003

Emissions VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark

Harmonics IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001

Immunity CSIPR 24 EN 55024

Ruggedized NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386

Restriction of Hazardous Substances Expanion trays compliant under spare parts exemption only.
Dimensions and Weight
Dimensions (Height, Width, Depth) H: 8.8 cm (3.5 in.; 2U); W: 44.7 cm (17.6 in.); D: 54.5 cm (21.5 in.)

Weight (Fully Populated) 26.8 kg (59.1 lb.)
Warranty
Two year Sun two-year standard warranty, (1st year on site, 2nd year return to depot)

Service upgrades SunSpectrum service upgrades are available

¡@


¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºSun - XTA3511R01A1A2500 - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºSun - StorEdge 3511 (500GB * 5, 1 RAID)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@