Standard Interfaces
|
Host interface |
2 Gb Fibre Channel |
|
Drives |
3.5 in. low profile |
|
Supported drives |
Dual-ported 1.5 Gb/s Serial ATA with
active-active loops, 250 GB, 500 GB 7200 rpm SATA |
|
Maximum number of host ports |
Dual RAID controllers: 12x2 Gb Fibre Channel
host ports (no expansion); 6x2 Gb Fibre Channel with expansion
trays |
|
Maximum cable length |
250 m |
Tray (12 HDDs) and RAID Array (108 HDDs) Maximum Raw Storage
Capacities
|
250GB 7200rpm HDDs |
3TB per 2U tray; expandable to 18TB per RAID
array |
|
500GB 7200rpm HDDs |
6TB per 2U tray; expandable to 54TB per RAID
array |
RAID Controller Card
|
RAID configurations |
Expansion (no controller); single RAID
controller; dual (mirrored) RAID controllers |
|
RAID levels |
0, 1, 1+0, 3, 5, 3+0, and 5+0 |
|
Max. LUNS |
Up to 1,024 per RAID array |
|
Max. LUN sizes and max. number of logical
drives |
Firmware 4.11 and below: Max. 2TB LUN size; 8
logical drives max.
Firmware 4.11 and above: Max. 16TB LUN size; 32 logical
drives max.
|
|
Max. local and/or global hot spares |
Up to 20 (RAID set and disk quantity
dependent) per RAID array
|
|
Cache size (read and write) |
1GB per controller |
|
Cache battery backup |
Up to 72 hours |
|
Cache write policy |
Write Back¡Xdefault; Write Through¡Xuser
configurable |
|
Cache selectable block sizes |
32K (random file transfer); 128K (sequential
file transfer)
|
|
Included Management software |
Sun StorEdge Configuration Service software;
Sun StorEdge support Diagnostic Reporter software |
|
Optional supported software |
Sun StorEdge Enterprise Storage Manager, Sun
StorEdge Traffic Manager, Sun Cluster 3, VERITAS NetBackup and
VERITAS Volume Manager including DMP, Sun Logical Volume Manager
for the Solaris 9 Operating System, Sun Solstice DiskSuite for
the Solaris 8 Operating System, Sun StorEdge Resource
Management, Sun StorEdge Utilization, and Sun StorEdge
Performance Suites |
Supported Host Platforms
|
Supported Host Servers |
All Sun Enterprise, Netra, and Sun Fire
SPARC-based and Sun Fire x86-based servers; x86-based (Intel and
AMD) third-party servers; IBM RISC-based servers; HP RISC-based
servers |
|
Supported host bus adapters |
- Sun Solaris Operating Systems 8, 9, 10 (SPARC-based):
X6727A, X6767A, X6768A, SG-XPCI1FC-QF2, SG-XPCI2FC-QF2,
SG-XPCI1FC-JF2, SG-XPCI2FC-JF2
- Sun Solaris x86 10: X9279A (Sun Fire V20Z and V40z
servers)
- Red Hat Linux, Enterprise Edition, 32b 64b; Novell SuSE
Linux Enterprise server 8; Novell SuSE Linux 9: QLA23XX 2Gb
FC PCI*
- MS Windows NT EE 4.0/2000/2003 server/Novell NetWare
5.1, 6.0, 6.5: QLA23XX 2Gb FC PCI*
- HP-UX 11.0 and 11i: Emulex LP9XXX 2Gb FC PCI* and
compatible
- IBM-AIX 4.3.3 and 5.1L (32 and 64 bit): Emulex LP9XXX
2Gb FC PCI* and compatible
*Note: All non-Sun host bus adapters supported by third-party
vendor |
Reliability, Availability, Serviceability (RAS)
|
RAS |
- Non-disruptive controller firmware upgrades using dual
RAID controllers via SSCS
- Hot-swap RAID controllers with battery-backed mirrored
1GB cache, (with dual RAID controllers)
- Up to twelve hot-swap disk drives per RAID array tray
and per expansion tray
- Dual hot-swap, redundant, load-sharing power supplies
with dual independent AC inputs
- Hot-swap, redundant electrically-isolated redundant
cooling fans
- Local and global hot sparing
|
Electrical Requirements
|
Wattage |
420W each (Dual Hot-Swap Redundant Power
Supplies) |
|
AC Voltage |
100 to 240 VAC, single phase |
|
AC Power requirement |
90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)
|
|
AC Current per input |
100 to 240 VAC, 50 to 60 Hz, 5.0¡V7.1A |
|
DC Voltage |
¡V48 or ¡V60 VDC, 18A |
|
DC Power requirement |
¡V36 to ¡V75 VDC |
|
DC Current per input |
¡V48 or ¡V60 VDC, 18A |
Environment
|
Temperature |
- Operating: 5¢XC to 40¢XC (41¢XF to 104¢XF)
- Nonoperating: ¡V40¢XC to 65¢XC (¡V40¢XF to 149¢XF)
|
|
Humidity (non-condensing) |
- Operating: 10% to 90% relative to 38¢XC
- Nonoperating: 0% to 90% relative to 27¢XC
|
|
Altitude |
- Operating: ¡V30m to 3048m(¡V100 to 10,000 ft.)
- Nonoperating: ¡V30m to 12,192m(¡V100 to 40,000 ft.)
|
|
Shock |
- Operating: 5.0 G, 11-ms, half-sine
- Nonoperating: 15.0 G, 11-ms, half-sine
|
|
Vibration |
- Operating: 0.2 G, 5¡V500 Hz, swept-sine
- Nonoperating: 1.0 G, 5¡V500 Hz, swept-sine
|
|
Noise * |
- Operating: LWAD = 6.6 bels
- Nonoperating: LWAD = 6.6 bels
*LWAD (1 bel = 10 dB) Declared noise emissions in accordance
with ISO 9296, measured at 23¢XC. |
Regulations - Meets or exceeds the following requirements:
|
Safety |
UL listed UL 60950:2000, CSA-C22.2 No.
60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark;
S-Mark, FCC Part 15 Class B, CISPR 22 55022:1998 Class B,
ICES-003 |
|
Emissions |
VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS
13438 Class B, S Mark |
|
Harmonics |
IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001
|
|
Immunity |
CSIPR 24 EN 55024 |
|
Ruggedized |
NEBS Level 3 (GR-63-CORE; GR-1089-CORE),
MIL-STD-810F, ETSI EN 300 386 |
|
Restriction of Hazardous Substances |
Expanion trays compliant under spare parts
exemption only.
|
Dimensions and Weight
|
Dimensions (Height, Width, Depth) |
H: 8.8 cm (3.5 in.; 2U); W: 44.7 cm (17.6
in.); D: 54.5 cm (21.5 in.) |
|
Weight (Fully Populated) |
26.8 kg (59.1 lb.) |
Warranty
|
Two year |
Sun two-year standard warranty, (1st year on
site, 2nd year return to depot) |
|
Service upgrades |
SunSpectrum service upgrades are available
|