­º­¶> Àx¦s³]³Æ/³Æ¥÷¤è®×

>>ÂsÄý©Ò¦³CiscoÀx¦s³]³Æ/³Æ¥÷¤è®×

Cisco
Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch

«¬¸¹¡GCisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch


CiscoCisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºCisco - Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch - Àx¦s³]³Æ/³Æ¥÷¤è®×
³Ì¦nªºCisco - Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óCisco¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§Cisco²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§Cisco­ì¼t°t¥ó


¡@

¡@

¡@


Cisco
Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch - ServerBank¸ê°T±ÄÁʺô
Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ

Protocols

¡´  Fibre Channel standards
¡´  FC-PH, Revision 4.3 (ANSI INCITS 230-1994)
¡´  FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996)
¡´  FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999)
¡´  FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997)
¡´  FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998)
¡´  FC-PI, Revision 13 (ANSI INCITS 352-2002)
¡´  FC-PI-2, Revision 10 (ANSI INCITS 404-2006)
¡´  FC-PI-3, Revision 4 (ANSI INCITS 460-2011)
¡´  FC-PI-4, Revision 8 (ANSI INCITS 450-2008)
¡´  FC-PI-5, Revision 6 (ANSI INCITS 479-2011)
¡´  FC-PI-6 (ANSI INCITS 512-2015)
¡´  FC-FS, Revision 1.9 (ANSI INCITS 373-2003)
¡´  FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007)
¡´  FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007)
¡´  FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011)
¡´  FC-FS-4
¡´  FC-LS, Revision 1.62 (ANSI INCITS 433-2007)
¡´  FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011)
¡´  FC-LS-3, Includes revision 3.53
¡´  FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001)
¡´  FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004)
¡´  FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006)
¡´  FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010)
¡´  FC-SW-6
¡´  FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001)
¡´  FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004)
¡´  FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007)
¡´  FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010)
¡´  FC-GS-7, Includes revision 10.8
¡´  FCP, Revision 12 (ANSI INCITS 269-1996)
¡´  FCP-2, Revision 8 (ANSI INCITS 350-2003)
¡´  FCP-3, Revision 4 (ANSI INCITS 416-2006)
¡´  FCP-4, Revision 2b (ANSI INCITS 481-2011)
¡´  FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001)
¡´  FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003)
¡´  FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007)
¡´  FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011)
¡´  FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014)
¡´  FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014)
¡´  FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003)
¡´  FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006)
¡´  FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008)
¡´  FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010)
¡´  FC-VI, Revision 1.84 (ANSI INCITS 357-2002)
¡´  FC-SP, Revision 1.8 (ANSI INCITS 426-2007)
¡´  FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012)
¡´  FAIS, Revision 1.03 (ANSI INCITS 432-2007)
¡´  FAIS-2, Revision 2.23 (ANSI INCITS 449-2008)
¡´  FC-IFR, Revision 1.06 (ANSI INCITS 475-2011)
¡´  FC-FLA, Revision 2.7 (INCITS TR-20-1998)
¡´  FC-PLDA, Revision 2.1 (INCITS TR-19-1998)
¡´  FC-Tape, Revision 1.17 (INCITS TR-24-1999)
¡´  FC-MI, Revision 1.92 (INCITS TR-30-2002)
¡´  FC-MI-2, Revision 2.6 (INCITS TR-39-2005)
¡´  FC-MI-3, Revision 1.03 (INCITS TR-48-2012)
¡´  FC-DA, Revision 3.1 (INCITS TR-36-2004)
¡´  FC-DA-2, Revision 1.06 (INCITS TR-49-2012)
¡´  FC-MSQS, Revision 3.2 (INCITS TR-46-2011)
¡´  Fibre Channel classes of service: Class 2, Class 3, and Class F
¡´  Fibre Channel standard port types: E, F, and B
¡´  Fibre Channel enhanced port types: SD, ST, and TE
¡´  FC-NVMe
¡´  In-band management using IP over Fibre Channel (RFC 2625)
¡´  IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338)
¡´  Extensive IETF-standards-based TCP/IP, Simple Network Management Protocol Version 3 (SNMPv3), and Remote Monitoring (RMON) MIBs

Fibre Channel ports

¡´  Fixed-switch form factor with 48 SFP+ ports base
¡´  Entry-level 24-port preactivated base model with flexibility to turn on any 24 ports
¡´  Incremental ports
   8-ports upgrade license offers the option of upgrading to 32, 40, and 48 ports

Security

¡´  VSAN fabric isolation
¡´  Intelligent packet inspection at port level
¡´  Hardware zoning by Access Control Lists (ACLs)
¡´  Fibre Channel Security Protocol (FC-SP) switch-to-switch authentication
¡´  FC-SP host-to-switch authentication
¡´  Role-based access control (RBAC) using RADIUS, TACACS+, or Lightweight Directory Access Protocol (LDAP) authentication, authorization, and accounting (AAA) functions
¡´  Secure FTP (SFTP)
¡´  Secure Shell Protocol Version 2 (SSHv2)
¡´  Simple Network Management Protocol Version 3 (SNMPv3) implementing Advanced Encryption Standard (AES)
¡´  Control-plane security
¡´  Cisco TrustSec ® payload encryption
¡´  Secure Boot and Anti-counterfeit technology

Performance

¡´  Port speed: 4-, 8-, 16-, and 32-Gbps autosensing with 32 Gbps of dedicated bandwidth per port
¡´  Aggregate bandwidth of 1.5-Tbps end-to-end full duplex
¡´  Buffer credits: Up to 8300 for a group of 16 ports, with a default of 500 buffer credits per port and a maximum of 8270 buffer credits for a single port in the group
¡´  Port groups: 3 port groups of 16 ports each
¡´  Port channel: Up to 16 load-balanced physical links grouped in one port channel

Diagnostics

¡´  Power-On-Self-Test (POST) diagnostics
¡´  Online Health Management System (OHMS) diagnostics
¡´  Internal loopbacks
¡´  SPAN
¡´  Fibre Channel traceroute
¡´  Fibre Channel ping
¡´  Fibre Channel debug
¡´  Cisco Fabric Analyzer
¡´  Syslog
¡´  Port-level statistics
¡´  Link diagnostics (E-port and F-port links)
¡´  Read Diagnostic Parameter

Serviceability

¡´  Configuration file management
¡´  Call Home
¡´  Port beaconing
¡´  Link cable beacon
¡´  System LEDs
¡´  SNMP traps for alerts

Reliability and availability

¡´  Cisco In-Service Software Upgrade (ISSU)
¡´  Hot-swappable, dual redundant power supplies
¡´  Hot-swappable fan tray with switch integrated temperature and power management
¡´  Hot-swappable SFP+ optics
¡´  Stateful process restart
¡´  Any port configuration for port channels
¡´  Fabric-based multipathing
¡´  Per-VSAN fabric services
¡´  Port tracking
¡´  Virtual Router Redundancy Protocol (VRRP) for management IP interface
¡´  FEC with HBA ports
¡´  Buffer-to-buffer state change notification with HBA ports

Network management

¡´  Management access through 2 out-of-band Ethernet ports
   mgmt0: 10/100/1000BASE-T port
   mgmt1: 1/10G SFP+ port #
¡´  RS-232 serial console port
¡´  USB power-on auto-provision port
¡´  Access protocols
¡´  Command-Line Interface (CLI) using the console and Ethernet port
¡´  SNMPv3 using the Ethernet port and in-band IP over Fibre Channel access
¡´  Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S)
¡´  NX-API for REST
¡´  full access through HTTPS REST
¡´  Distributed device alias service
¡´  Network security
¡´  Per-VSAN RBAC using LDAP, RADIUS, and TACACS+-based AAA functions
¡´  Simple File Transfer Protocol (SFTP)
¡´  SSHv2 implementing AES
¡´  SNMPv3 implementing AES
¡´  Cisco D ata Center Network Manager (DCNM)

Programming interfaces

¡´  Scriptable CLI
¡´  Cisco DCNM web services API
¡´  NX-API RESTful interfaces
¡´  Onboard Python interpreter
¡´  Cisco Embedded Event Manager (EEM)
¡´  Cisco NX-OS Software scheduler

Physical dimensions
(H x W x D) and weight

¡´  1 Rack Unit (1RU) (1.72 x 17.3 x 22.3 in. [4.37 x 43/9 x 56.6 cm]) excluding Power Supply Unit (PSU) and fan-tray handles
¡´  16.7 lb. (8.5 kg)

Power

¡´  80 Plus Platinum certified power supplies
¡´  Power supply options
   650W AC in base model, port-side exhaust variant (2 per switch)
   650W AC in base model, port-side intake variant (2 per switch)
¡´  Power cord
   IEC60320 C14 plug on 650W power supply connecting to a notched C15 socket connector (check Table 6 later in this document for power cords specific to regions)
¡´  AC input: 100 to 240 VAC (10% range)
¡´  Frequency: 50 to 60 Hz (nominal)
¡´  Typical power consumption
   217W for Idle 48-Port switch without optics modules
   251W for 48-Port switch with 24 32G SW optics modules under typical conditions
   297W for 48-Port switch with 48 32G SW optics modules under typical conditions
¡´  Airflow
   Back to front (toward ports) using port-side exhaust fans
   Front to back (inward from ports) using port-side intake fans
   50 Cubic Feet per Minute (CFM) through system fan assembly at 77¢XF (25¢XC)
   100 CFM maximum

Temperature range

¡´  Temperature, ambient operating:
   32 to 104¢XF (0 to 40¢XC) with port-side exhaust and intake airflow variants
¡´  Temperature, ambient nonoperating and storage: ¡V40 to 158¢XF (¡V40 to 70¢XC)
¡´  Relative humidity, ambient (noncondensing) operating: 10 to 90%
¡´  Relative humidity, ambient (noncondensing) nonoperating and storage: 10 to 95%
¡´  Altitude, operating: ¡V197 to 6500 ft (¡V60 to 2000m)

Approvals and compliance

¡´  Safety compliance
¡´  CE Marking
¡´  UL 60950
¡´  CAN/CSA-C22.2 No. 60950
¡´  EN 60950
¡´  IEC 60950
¡´  TS 001
¡´  AS/NZS 3260
¡´  IEC60825
¡´  EN60825
¡´  21 CFR 1040
¡´  EMC compliance
¡´  FCC Part 15 (CFR 47) Class A
¡´  ICES-003 Class A
¡´  EN 55022 Class A
¡´  CISPR 22 Class A
¡´  AS/NZS 3548 Class A
¡´  VCCI Class A
¡´  EN 55024
¡´  EN 50082-1
¡´  EN 61000-6-1
¡´  EN 61000-3-2
¡´  EN 61000-3-3

Fabric services

¡´  Name server
¡´  Registered State Change Notification (RSCN)
¡´  Login services
¡´  Fabric Configuration Server (FCS)
¡´  Broadcast
¡´  In-order delivery

Advanced functions

¡´  VSAN
¡´  IVR
¡´  Port Channel with multipath load balancing
¡´  Flow- and zone-based QoS

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºCisco - Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºCisco - Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 NASºô¸ôÀx¦sÀɮצøªA¾¹
 ServerBank±ÀÂ˾÷ºØ
 ®à¤W«¬
 ¾÷¬[¦¡
 ª½¥ß¦¡
 ºÏºÐ°}¦C°t¥ó
 ¦Û°Ê¥úºÐ«þ¨©¾÷
 ¥~±µ¦¡µwºÐ
 ºÏ±a¾÷
 SDLT
 DLT
 LTO 1/2/3/4
 Ultrium I
 Ultrium II
 SAIT
 AIT
 AIT Turbo
 DAT
 DDS
 ºÏ±a´«±a¾÷Autoloader
 iSCSI¸Ñ¨M¤è®×
 iSCSIºÏºÐ°}¦C
 iSCSI¾ô±µ¾¹
 ºÏºÐ°}¦CRAID
 ServerBank±ÀÂ˾÷ºØ
 iSCSI
 iSCSI to SAS
 SATA
 SCSI-to-SCSI
 SCSI-to-IDE
 SCSI-to-SATA
 Fibre-to-SCSI
 Fibre-to-IDE
 Fibre-to-SATA
 Fibre-to-Fibre
 Fibre to SAS
 USB-to-IDE
 SATA-to-SATA
 SATA-to-IDE
 SAS
 IDE-to-IDE
 1394-to-IDE
 JBOD
 ºÏºÐ°}¦CÂd
 1394B-to-SATAII
 1394B-to PATA
 °ïÅ|¦¡Àx¦s¥~±µ²°
 SAS-to-SATA
 SAS-to-SAS
 SCSI-to-SAS
 PCIE
 USB
 IDE
 SAN¸Ñ¨M¤è®×
 ¥úÅÖ³q¹D¥æ´«¾¹
 ¥úÅÖ³q¹D¤¶­±¥d
 SAN Storage
 SAN Software
 ¥úÅÖ³q¹D¾ô±µ¾¹
 ¾É¦V¾¹director
 ¥úÅÖ¼Ò²Õ
 Àx¦sºÞ²z³nÅé
 ºÏ±aÂd
 ºÏ±a
 ¦Û°Ê´«¤ù¥úºÐ
 ÂÅ¥ú¥úºÐÂd
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > Àx¦s³]³Æ/³Æ¥÷¤è®×


CiscoCisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch

Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch


¼tµP¡GCisco      >>ÂsÄýCisco¥þ³¡²£«~
«¬¸¹¡GCisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºCisco - Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºCisco - Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óCisco¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§Cisco²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§Cisco­ì¼t°t¥ó


¡@

¡@

¡@


Cisco
Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch - ServerBank¸ê°T±ÄÁʺô
Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ

Protocols

¡´  Fibre Channel standards
¡´  FC-PH, Revision 4.3 (ANSI INCITS 230-1994)
¡´  FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996)
¡´  FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999)
¡´  FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997)
¡´  FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998)
¡´  FC-PI, Revision 13 (ANSI INCITS 352-2002)
¡´  FC-PI-2, Revision 10 (ANSI INCITS 404-2006)
¡´  FC-PI-3, Revision 4 (ANSI INCITS 460-2011)
¡´  FC-PI-4, Revision 8 (ANSI INCITS 450-2008)
¡´  FC-PI-5, Revision 6 (ANSI INCITS 479-2011)
¡´  FC-PI-6 (ANSI INCITS 512-2015)
¡´  FC-FS, Revision 1.9 (ANSI INCITS 373-2003)
¡´  FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007)
¡´  FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007)
¡´  FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011)
¡´  FC-FS-4
¡´  FC-LS, Revision 1.62 (ANSI INCITS 433-2007)
¡´  FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011)
¡´  FC-LS-3, Includes revision 3.53
¡´  FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001)
¡´  FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004)
¡´  FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006)
¡´  FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010)
¡´  FC-SW-6
¡´  FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001)
¡´  FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004)
¡´  FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007)
¡´  FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010)
¡´  FC-GS-7, Includes revision 10.8
¡´  FCP, Revision 12 (ANSI INCITS 269-1996)
¡´  FCP-2, Revision 8 (ANSI INCITS 350-2003)
¡´  FCP-3, Revision 4 (ANSI INCITS 416-2006)
¡´  FCP-4, Revision 2b (ANSI INCITS 481-2011)
¡´  FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001)
¡´  FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003)
¡´  FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007)
¡´  FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011)
¡´  FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014)
¡´  FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014)
¡´  FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003)
¡´  FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006)
¡´  FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008)
¡´  FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010)
¡´  FC-VI, Revision 1.84 (ANSI INCITS 357-2002)
¡´  FC-SP, Revision 1.8 (ANSI INCITS 426-2007)
¡´  FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012)
¡´  FAIS, Revision 1.03 (ANSI INCITS 432-2007)
¡´  FAIS-2, Revision 2.23 (ANSI INCITS 449-2008)
¡´  FC-IFR, Revision 1.06 (ANSI INCITS 475-2011)
¡´  FC-FLA, Revision 2.7 (INCITS TR-20-1998)
¡´  FC-PLDA, Revision 2.1 (INCITS TR-19-1998)
¡´  FC-Tape, Revision 1.17 (INCITS TR-24-1999)
¡´  FC-MI, Revision 1.92 (INCITS TR-30-2002)
¡´  FC-MI-2, Revision 2.6 (INCITS TR-39-2005)
¡´  FC-MI-3, Revision 1.03 (INCITS TR-48-2012)
¡´  FC-DA, Revision 3.1 (INCITS TR-36-2004)
¡´  FC-DA-2, Revision 1.06 (INCITS TR-49-2012)
¡´  FC-MSQS, Revision 3.2 (INCITS TR-46-2011)
¡´  Fibre Channel classes of service: Class 2, Class 3, and Class F
¡´  Fibre Channel standard port types: E, F, and B
¡´  Fibre Channel enhanced port types: SD, ST, and TE
¡´  FC-NVMe
¡´  In-band management using IP over Fibre Channel (RFC 2625)
¡´  IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338)
¡´  Extensive IETF-standards-based TCP/IP, Simple Network Management Protocol Version 3 (SNMPv3), and Remote Monitoring (RMON) MIBs

Fibre Channel ports

¡´  Fixed-switch form factor with 48 SFP+ ports base
¡´  Entry-level 24-port preactivated base model with flexibility to turn on any 24 ports
¡´  Incremental ports
   8-ports upgrade license offers the option of upgrading to 32, 40, and 48 ports

Security

¡´  VSAN fabric isolation
¡´  Intelligent packet inspection at port level
¡´  Hardware zoning by Access Control Lists (ACLs)
¡´  Fibre Channel Security Protocol (FC-SP) switch-to-switch authentication
¡´  FC-SP host-to-switch authentication
¡´  Role-based access control (RBAC) using RADIUS, TACACS+, or Lightweight Directory Access Protocol (LDAP) authentication, authorization, and accounting (AAA) functions
¡´  Secure FTP (SFTP)
¡´  Secure Shell Protocol Version 2 (SSHv2)
¡´  Simple Network Management Protocol Version 3 (SNMPv3) implementing Advanced Encryption Standard (AES)
¡´  Control-plane security
¡´  Cisco TrustSec ® payload encryption
¡´  Secure Boot and Anti-counterfeit technology

Performance

¡´  Port speed: 4-, 8-, 16-, and 32-Gbps autosensing with 32 Gbps of dedicated bandwidth per port
¡´  Aggregate bandwidth of 1.5-Tbps end-to-end full duplex
¡´  Buffer credits: Up to 8300 for a group of 16 ports, with a default of 500 buffer credits per port and a maximum of 8270 buffer credits for a single port in the group
¡´  Port groups: 3 port groups of 16 ports each
¡´  Port channel: Up to 16 load-balanced physical links grouped in one port channel

Diagnostics

¡´  Power-On-Self-Test (POST) diagnostics
¡´  Online Health Management System (OHMS) diagnostics
¡´  Internal loopbacks
¡´  SPAN
¡´  Fibre Channel traceroute
¡´  Fibre Channel ping
¡´  Fibre Channel debug
¡´  Cisco Fabric Analyzer
¡´  Syslog
¡´  Port-level statistics
¡´  Link diagnostics (E-port and F-port links)
¡´  Read Diagnostic Parameter

Serviceability

¡´  Configuration file management
¡´  Call Home
¡´  Port beaconing
¡´  Link cable beacon
¡´  System LEDs
¡´  SNMP traps for alerts

Reliability and availability

¡´  Cisco In-Service Software Upgrade (ISSU)
¡´  Hot-swappable, dual redundant power supplies
¡´  Hot-swappable fan tray with switch integrated temperature and power management
¡´  Hot-swappable SFP+ optics
¡´  Stateful process restart
¡´  Any port configuration for port channels
¡´  Fabric-based multipathing
¡´  Per-VSAN fabric services
¡´  Port tracking
¡´  Virtual Router Redundancy Protocol (VRRP) for management IP interface
¡´  FEC with HBA ports
¡´  Buffer-to-buffer state change notification with HBA ports

Network management

¡´  Management access through 2 out-of-band Ethernet ports
   mgmt0: 10/100/1000BASE-T port
   mgmt1: 1/10G SFP+ port #
¡´  RS-232 serial console port
¡´  USB power-on auto-provision port
¡´  Access protocols
¡´  Command-Line Interface (CLI) using the console and Ethernet port
¡´  SNMPv3 using the Ethernet port and in-band IP over Fibre Channel access
¡´  Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S)
¡´  NX-API for REST
¡´  full access through HTTPS REST
¡´  Distributed device alias service
¡´  Network security
¡´  Per-VSAN RBAC using LDAP, RADIUS, and TACACS+-based AAA functions
¡´  Simple File Transfer Protocol (SFTP)
¡´  SSHv2 implementing AES
¡´  SNMPv3 implementing AES
¡´  Cisco D ata Center Network Manager (DCNM)

Programming interfaces

¡´  Scriptable CLI
¡´  Cisco DCNM web services API
¡´  NX-API RESTful interfaces
¡´  Onboard Python interpreter
¡´  Cisco Embedded Event Manager (EEM)
¡´  Cisco NX-OS Software scheduler

Physical dimensions
(H x W x D) and weight

¡´  1 Rack Unit (1RU) (1.72 x 17.3 x 22.3 in. [4.37 x 43/9 x 56.6 cm]) excluding Power Supply Unit (PSU) and fan-tray handles
¡´  16.7 lb. (8.5 kg)

Power

¡´  80 Plus Platinum certified power supplies
¡´  Power supply options
   650W AC in base model, port-side exhaust variant (2 per switch)
   650W AC in base model, port-side intake variant (2 per switch)
¡´  Power cord
   IEC60320 C14 plug on 650W power supply connecting to a notched C15 socket connector (check Table 6 later in this document for power cords specific to regions)
¡´  AC input: 100 to 240 VAC (10% range)
¡´  Frequency: 50 to 60 Hz (nominal)
¡´  Typical power consumption
   217W for Idle 48-Port switch without optics modules
   251W for 48-Port switch with 24 32G SW optics modules under typical conditions
   297W for 48-Port switch with 48 32G SW optics modules under typical conditions
¡´  Airflow
   Back to front (toward ports) using port-side exhaust fans
   Front to back (inward from ports) using port-side intake fans
   50 Cubic Feet per Minute (CFM) through system fan assembly at 77¢XF (25¢XC)
   100 CFM maximum

Temperature range

¡´  Temperature, ambient operating:
   32 to 104¢XF (0 to 40¢XC) with port-side exhaust and intake airflow variants
¡´  Temperature, ambient nonoperating and storage: ¡V40 to 158¢XF (¡V40 to 70¢XC)
¡´  Relative humidity, ambient (noncondensing) operating: 10 to 90%
¡´  Relative humidity, ambient (noncondensing) nonoperating and storage: 10 to 95%
¡´  Altitude, operating: ¡V197 to 6500 ft (¡V60 to 2000m)

Approvals and compliance

¡´  Safety compliance
¡´  CE Marking
¡´  UL 60950
¡´  CAN/CSA-C22.2 No. 60950
¡´  EN 60950
¡´  IEC 60950
¡´  TS 001
¡´  AS/NZS 3260
¡´  IEC60825
¡´  EN60825
¡´  21 CFR 1040
¡´  EMC compliance
¡´  FCC Part 15 (CFR 47) Class A
¡´  ICES-003 Class A
¡´  EN 55022 Class A
¡´  CISPR 22 Class A
¡´  AS/NZS 3548 Class A
¡´  VCCI Class A
¡´  EN 55024
¡´  EN 50082-1
¡´  EN 61000-6-1
¡´  EN 61000-3-2
¡´  EN 61000-3-3

Fabric services

¡´  Name server
¡´  Registered State Change Notification (RSCN)
¡´  Login services
¡´  Fabric Configuration Server (FCS)
¡´  Broadcast
¡´  In-order delivery

Advanced functions

¡´  VSAN
¡´  IVR
¡´  Port Channel with multipath load balancing
¡´  Flow- and zone-based QoS

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºCisco - Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºCisco - Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@