ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô >
ºô¸ô³]³Æ/ÀW¼eºÞ²z
|
|
|
¡@ |
FoundryNetworks FastIron SuperX Family - ServerBank¸ê°T±ÄÁʺô SuperX ºô¸ô³]³Æ/ÀW¼eºÞ²z
¡@
IEEE Compliance
- 802.3 10BaseT
- 802.3u 100BaseTX
- 802.3z 100BaseFX
- 802.3z 100BaseLX
- 802.3ab 1000BaseT
- 802.3ae 10-Gigabit
Ethernet
- 802.3af Power over
Ethernet
- 802.3x Flow Control
- 802.3ad Link Aggregation
- 802.1d Bridging
- 802.1p/qVLAN Tagging
- 802.1W Rapid STP
- PVST/PVST+/PVRST
- 802.1X User
Authentication with Dynamic Filters and VLAN
assignment
- 802.3 Ethernet Like MIB
- Repeater MIB
- Ethernet Interface MIB
- SNMPv1, v2c, and v3
- SNMP MIB II
RFC Compliance - BGPv4
- RFC 1269, 1657 BGP3 and
BGP4 MIBs
- RFC 1745 OSPF
Interactions
- RFC 1771 BGP4
- RFC 1965 BGP4
Confederations
- RFC 1997 Communities and
Attributes
- RFC 2385 MD5
- Authentication of BGP
Session
- RFC 2439 Route Flap
Dampening
- RFC 2796 Route Reflection
- RFC 2842 BGP4
Capabilities
RFC Compliance - OSPF
- RFC 1583 and 2328 OSPF v2
- RFC 1587 OSPF NSSA
- RFC 1745 OSPF
Interactions
- RFC 1765 OSPF Database
Overflow
- RFC 1850 OSPF Traps
- RFC 1850 OSPF v2 MIB
- RFC 2154 OSPF w/Digital
Signatures (Password, MD-5)
- RFC 2178 OSPF
- RFC 2370 OSPF Opaque LSA
Options
- RFC 2385 TCP MD5
- RFC 2439 Route Flap
Damping
- RFC 2842 Capabilities
Advertisement
- RFC 2918 Route Refresh
Capability
RFC Compliance - RIP
- RFC 1058 RIP v1
- RFC 1723 RIP v2
- RFC 1812 RIP Requirements
RFC Compliance - IP Multicast
- DVMRP v3-07
- PIM-DM v1
- RFC 1112 IGMP
- RFC 1122 DVMRP Host
Requirements
- RFC 1122 Host Extensions
- RFC 1256 ICMP Router
Discovery Protocol
- RFC 2236 IGMP v2
- RFC 2362 PIM-SM
RFC Compliance - General
Routing Protocols
- RFC 768 UDP
- RFC 783 TFTP
- RFC 791 IP
- RFC 792 ICMP
- RFC 793 TCP
- RFC 826 ARP
- RFC 854 TELNET
- RFC 894 IP over Ethernet
- RFC 903 RARP
- RFC 906 TFTP Bootstrap
- RFC 951 BootP
- RFC 1027 Proxy ARP
- RFC 1122 Host
Requirements
- RFC 1256 IRDP
- RFC 1519 CIDR
- RFC 1541, 1542 & 2131
BootP/DHCP Helper
- RFC 1542 BootP Extensions
- RFC 1591 DNS (client)
- RFC 1812 General Routing
- RFC 2338VRRP
RFC Compliance - Others
- RFC 1157 SNMPv1
- RFC 1191 Path MTU
Discovery
- RFC 1215 SNMP Generic
Traps
- RFC 1354 IP Forwarding
MIB
- RFC 1573 SNMP MIB II
- RFC 1757 RMON Groups 1,
2, 3, 9
- RFC 1905, 1906 SNMPv2c
- RFC 4330 SNTP
- RFC 2068 HTTP
- RFC 2138 RADIUS
- RFC 3176 sFlow
- RFC 3411 SNMPv3 Framework
- RFC 3412 SNMPv3
Processing
- RFC 3414 SNMPv3 USM
- RFC 3415 SNMPv3VACM
- TACACS+ v1.78
- MRP I, MRP II (Metro Ring
Protocol)
- UDLD (Uni-directional
Link Detection)
- IGMP Snooping (v1, v2,
v3)
- RFC 2674 P-Bridge and
Q-Bridge
- Jumbo Frame with Gigabit
Ethernet
System Management
- IronView Network Manager
(INM) Web-based graphical user interface
- Industry Standard Command
Line Interface (CLI)
- Secure Copy
- Telnet and SSHv2
- SNMP v1, v2 and v3
- HTTP and HTTPS
- RMON HP OpenView for Sun
Solaris, HP-UX, IBMs AIX, and Windows NT
- Virtual Cable Tester
Element Security Options
- AAA
- RADIUS
- Secure Shell (SSHv2)
- Secure Copy (SCP)
- TACACS/ TACACS+
- Username/ Password
(Challenge and Response)
- Bi-level Access Mode
(Standard and EXEC Level)
- Protection for Denial of
Service attacks, such as TCP SYN or Smurf
Attacks
Physical Design
- ETSI ETS 300 119-4,
Engineering Requirements for Subracks in
misc Racks and Cabinets
- ANSI/EIA-310-D, Cabinets,
Racks, Panels, and Associated Equipment
Physical Dimensions
- FastIron SuperX and SX
800
10.4in (H) x 17.3in (D) x 17.5in (W)
26.3cm (H) x 43.8cm (D) x 44.5cm (W)
- FastIron SX 1600
24.5in (H) x 17.3in (D) x 17.5in (W)
62.2cm (H) x 43.8cm (D) x 44.5cm (W)
Weight (Fully Loaded)
- FastIron SuperX and SX
800
70 lbs (31 kg)
- FastIron SX 1600
196 lbs (88.6 kg)
Environmental
- Operating Temperature: 0
¢XC to 40 ¢XC (32 ¢XF to 104 ¢XF)
- Relative Humidity: 5 to
90%, @40 ¢XC (104 ¢XF,non condensing)
- Operating Altitude: 6600
ft (2,000 m)
- Storage Temperature: -25
¢XC to 70 ¢XC (-13 ¢XF to 158 ¢XF)
- Storage Humidity: 95%
maximum relative humidity, non-condensing
- Storage Altitude: 15,000
ft (4,500 m) maximum
- EU 2002/95/EC RoHS
Directive
MTBF
- SuperX Chassis, Fan Tray,
1 P/S: 269,386 hrs
- SX 800 Chassis, Fan Tray,
1 P/S: 142,786 hrs
- SX 800 Chassis, Fan Tray,
2 P/S: 230,584 hrs
- SX1600 Chassis, Fan Tray,
2 P/S: 99,908 hrs
- SX1600 Chassis, Fan Tray,
4 P/S: 213,865 hrs
- M1 Management Module:
287,664 hrs
- M2 Management Module:
287,664 hrs
- M3 Management Module,
Zero ports: 534,522 hrs
- M4 Management Module,
2x10-GbE ports: 269,436 hrs
- 24-port 10/100/1000
Copper Module: 352,103 hrs
- 24-port SFP Module:
348,204 hrs
- 2-port 10-GbE Module:
464,938 hrs
SuperX System Power
Specifications
- System Power Supply
(SX-ACPWR, SX-DCPWR)
- -40 ¡V -60VDC
Consumption (Amps): 36A
- 100 ¡V 120VAC
Consumption (Amps): 14.3A
- 200 ¡V 240VAC
Consumption (Amps): 7.2A
- AC Frequency: 50 ¡V
60Hz
- Max BTU: 4874 BTU/Hr
- Max Watts (Output):
1200W
- Max Watts (Input):
1428W
- 1250W PoE Power Supply
- 100 ¡V 120VAC
Consumption (Amps): 14A
- 200 ¡V 240VAC
Consumption (Amps): 7A
- AC Frequency: 50 ¡V
60Hz
- Max BTU: 4736 BTU/Hr
- Max Watts (Output):
1250W
- Max Watts (Input):
1388W
- 2500W PoE Power Supply
(SX-ACPWR-2500-POE)
- 200 ¡V 240VAC
Consumption (Amps): 14A
- AC Frequency: 50 ¡V
60Hz
- Max BTU: 9471 BTU/Hr
- Max Watts (Output):
2500W
- Max Watts (Input):
2775W
Safety Agency Approvals
- CAN/CSA-C22.2
No.60950-1-03, Information Technology
Equipment¡VSafety ¡V Part 1: General
Requirement
- UL 60950-1, Information
Technology Equipment ¡V Safety ¡V Part 1:
General Requirement
- EN 60950-1, Information
Technology Equipment ¡V Safety ¡V Part 1:
General Requirement
- IEC 60950-1, Information
Technology Equipment ¡V Safety ¡V Part 1:
General Requirement
- EN 60825-1, Safety of
Laser Products. Equipment Classification,
Requirements and User Guide
- EN 60825-2, Safety of
Laser Products, Safety of Optical Fibre
Communications Systems
RoHS Compliant (5 of 6)
Electromagnetic Emission
- ICES-003, Electromagnetic
Emission
- FCC Class A
- EN 55022/CISPR 22 Class A
- VCCI Class A
- EN 61000-3-2, Power Line
Harmonics
- EN 61000-3-3, Voltage
Fluctuation & Flicker
- EN 61000-6-3,
Electromagnetic Compatibility
- AS/NZS CISPR 22,
Electromagnetic Compatibility
Immunity
- EN 61000-6-1,
Electromagnetic Compatability, Generic
Standard
- EN 55024,Immunity
Characteristics Supersedes:
- EN 61000-4-2, ESD
- EN 61000-4-3,
Radiated, Radio Frequency,
Electromagnetic Field
- EN 61000-4-4,
Electrical Fast Transient
- EN 61000-4-5, Surge
- EN 61000-4-6,
Conducted Disturbances Induced by Radio
Frequency Fields
- EN 61000-4-8, Power
Frequency Magnetic Field
- EN 61000-4-11, Power
Frequency Magnetic Field
Warranty
¡@ |
|
¡D¥»¤å¥óªº¸ê°TY¦³×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ùY¦³»~¡A¥Hì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨äì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C
º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á!
ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶WÈÀu´fªºFoundryNetworks - SuperX - ºô¸ô³]³Æ/ÀW¼eºÞ²z
,³Ì¦nªºFoundryNetworks - FastIron SuperX Family±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
|
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§ÚÌ·|¬°±z¦Vì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú̳£¥i¼u©Ê°t¦X±zªº»Ýn³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G
1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901 |
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»¶ÁʶR¸ß»ù§ÚÌ·|¥ß§Y»P±zÁpô! |
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw |
|
¥I´Ú¤è¦¡¡G¦p«È¤á¬°º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C |
¶Ç¯uq³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨qÁʵ{§Ç¡A§ÚÌ·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{q³æ¡C |
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú̦¬¨ì±zq³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C |
°e³f¤è¦¡¡G(1) ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C |
°e³f½d³ò¡G¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±zt¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C |
°â«áªA°È¡GY²£«~¥»¨·å²«©Î¹B°e¹Lµ{¾ÉP·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C |
«O©T¬Fµ¦¡G ¹ê»Ú¥Hì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C |
¤O±ô¸ê°T ServerBank Inc. ²¤¶
¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G
»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶Û¡B¥xÆWªFªÛ¡B¥xÆW^¸â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B
¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B
ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B
¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B
Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B
¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B
´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B¸ºÐ¼s¼½¡B·¼é°Û¤ù¡B®É³ø©P¥Z¡B
±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B
²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡Bì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°
¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B
ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B
¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B
¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤±]±¶¹B¡B¥xÆW´¼¼z¥d¡B
¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½^¡B¿ßÀYÆN
©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B
x¤è¡G ªÅx¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B
|
|
|
|
|
|
|
¡@ |
|