Performance data
|
| |
Sun Fire X4200 |
Sun Fire X4200 M2 |
| Processor |
Up to two single-core/dual-core AMD Opteron
200 series processors, one MB Level 2 Cache per core |
Up to two Next-Generation AMD Opteron 2000
Series processors, one MB Level 2 cache per core |
|
| Main memory |
Four DIMM slots per CPU socket, DDR1/400 ECC
registered DIMMs (128-bit plus ECC databus), total eight DIMM
slots, up to 16 GB per CPU |
Four DIMM slots per CPU socket, DDR2/667 ECC
registered DIMMs (128-bit plus ECC databus), total eight DIMM
slots, up to 16 GB per CPU
|
|
System architecture
|
| |
Sun Fire X4200 |
Sun Fire X4200 M2 |
| System architecture |
Three 8.0 GB/sec. HyperTransport link with 6.0
GB/sec. access between processor and memory |
Three 8.0 GB/sec. Hypertransport links per
processor and 10.7 GB/sec. access between each processor and
memory |
|
Standard/Integrated Interfaces
|
| |
Sun Fire X4200 |
Sun Fire X4200 M2 |
| Network |
Four 10/100/1000Base-T Ethernet
ports |
|
| Network management |
One dedicated 10/100Base-T
Ethernet port |
|
| Serial |
One TIA/EIA-232-F asynchronous
RJ45 port |
|
| SAS |
Four channel SAS interface,
internal access only
|
|
| USB |
Two USB 1.1 ports (front), two USB 1.1 ports
(rear) |
Two USB 2.0 port (front), two USB 2.0 ports
(rear) |
|
| Expansion bus |
Five internal MD2 low-profile 64-bit PCI-X
slots (one at 100 MHz, one at 133 MHz, three at 66 MHz) |
Four internal low-profile 8-lane PCIe slots
and one internal MD2 low-profile 64-bit 133 MHz PCI-X slot |
|
Software
|
| |
Sun Fire X4200 |
Sun Fire X4200 M2 |
| Operating systems |
- Solaris 10 Operating System, 64-bit
- Red Hat Enterprise Linux 3.0, 32-bit/64-bit
- Red Hat Enterprise Linux 4.0, 64-bit
- SUSE LINUX Enterprise Server 9, 64-bit
- Windows Server 2003, Enterprise Edition, 32-bit/64-bit
- Windows Server 2003, Standard Edition, 32-bit/64-bit
- VMware ESX 2.5.x/3.0.x
Java Enterprise Services 4
- Solaris 10 Operating System
- Standard Linux distributions
|
- Solaris 10 Operating System, 64-bit
- Red Hat Enterprise Linux 4.0, 64-bit
- Windows Server 2003, Enterprise Edition, 32-bit/64-bit
- Windows Server 2003, Standard Edition, 32-bit/64-bit
Java Enterprise Services 4
- Solaris 10 Operating System
- Standard Linux distributions
|
|
| Languages |
- C/C++, FORTRAN (Solaris OS on x64)
- Java programming language
- All other standard Sun-supported languages
|
|
| Networking |
ONC, ONC+, NFS, WebNFS, TCP/IP,
SunLink, OSI, MHS, IPX/SPX, SMB technologies, and XML |
|
| Management |
ILOM Service Processor providing:
DMTF CLP-based CLI over SSH, Web-based GUI over HTTPS/HTTP, IPMI
2.0, SNMP V1, v2c and v3, remote graphical access over Ethernet
and remote storage over Ethernet
- N1 System Manager – discovering, grouping, bare metal
provisioning, hardware monitoring, OS monitoring
|
|
Mass Storage and Media
|
| |
Sun Fire X4200 |
Sun Fire X4200 M2 |
| Mass Storage |
Hot-swappable, 2.5-inch SAS
internal disks, RAID 0 and 1 onboard, up to four HDDs with
DVD-ROM/CD-RW |
|
Environment
|
| |
Sun Fire X4200 |
Sun Fire X4200 M2 |
| AC power |
90–264 V AC (47–63 Hz)
|
|
| DC power |
-48 V DC or -60 V DC (10.4 A at -48 V DC, 8.3
A at -60 V DC), -48 V DC or -60 V DC (10.4 A at -48 V DC, 8.3 A
at -60 V DC) |
-48 V DC or -60 V DC (10.4 A at -48 V DC, 8.3
A at -60 V DC), -48 V DC or -60 V DC (10.4 A at -48 V DC, 8.3 A
at -60 V DC)*
*Coming Soon |
|
| Operating temperature (single, non-rack
system) |
- 5°C to 35°C (41°F to 95°F)
- 10-90 percent relative humidity
- Non-condensing, 27°C max. wet bulb
|
|
| Non-operating temperature (single, non-rack
system) |
- -40°C to 65°C (-40°F to 149°F)
- Up to 93 percent relative humidity
- Non-condensing, 38°C max. wet bulb
|
|
| Operating Altitude (single, non-rack system)
|
Up to 3,048 m, maximum ambient
temperature is derated by 1°C per 300 m above 900 m |
|
| Non-Operating Altitude (single, non-rack
system) |
Up to 12000 m |
|
| Acoustic noise (single, non-rack system) |
- LwAd (1B = 10dB): 8.0 B at or below 25° C, 8.4 B at max
ambient
- LpAm bystander: 64 dB at or below 25° C, 69 dB at max
ambient
|
|
Power
|
| |
Sun Fire X4200 |
Sun Fire X4200 M2 |
| Power |
- Dual redundant, hot-swappable power supplies
- Maximum DC output: 550 W
|
|
Regulations
|
| |
Sun Fire X4200 |
Sun Fire X4200 M2 |
| |
Meets or exceeds the following
requirements:
|
|
| Safety |
IEC60950, UL/CSA60950, EN60950, CB
scheme with all country differences |
|
| RFI/EMI |
FCC Class A, Part 15 47 CFR,
EN55022, CISPR 22, EN300-386: v1.31, ICES-003 |
|
| Immunity |
EN55024, EN300-386:v1.3.2 |
|
Certifications
|
| |
Sun Fire X4200 |
Sun Fire X4200 M2 |
| Safety |
cULus Mark, TUV GS Mark, CE Mark,
CCC, GOST R, S-Mark
|
|
| EMC |
CE Mark (93/68/EEC), Emissions and
Immunity Class A Emissions Levels: FCC, VCCI, C-Tick, MIC, CCC,
GOST R, BSMI |
|
| Other |
Labeled per WEEE (Waste Electrical
and Electronic Equipment) Directive |
|
Dimensions and Weight
|
| |
Sun Fire X4200 |
Sun Fire X4200 M2 |
| Height |
87.6 mm (3.44 in) |
87.6 mm (3.44 in) |
|
| Width |
445 mm (17.5 in) |
445 mm (17.5 in) |
|
| Depth |
632 mm (24.8 in) |
632 mm (24.8 in) |
|
| Weight (w/ rack kit) |
25.5 kg (56.2 lbs.) max |
25.5 kg (56.2 lbs.) max |
|
Mounting option
|
| |
Sun Fire X4200 |
Sun Fire X4200 M2 |
| Mounting option |
19-inch rackmount kit |
19-inch rackmount kit |