­º­¶> Àx¦s³]³Æ/³Æ¥÷¤è®×

>>ÂsÄý©Ò¦³SunÀx¦s³]³Æ/³Æ¥÷¤è®×

Sun
Sun StorEdge(TM) 3510 FC Array Rack Ready, 730GB

«¬¸¹¡GXTA3510R01A2Z730


SunXTA3510R01A2Z730


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºSun - XTA3510R01A2Z730 - Àx¦s³]³Æ/³Æ¥÷¤è®×
³Ì¦nªºSun - Sun StorEdge(TM) 3510 FC Array Rack Ready, 730GB±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óSun¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§Sun²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§Sun­ì¼t°t¥ó


¡@

¡@

¡@


Sun
Sun StorEdge(TM) 3510 FC Array Rack Ready, 730GB - ServerBank¸ê°T±ÄÁʺô
XTA3510R01A2Z730
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ
Standard Interfaces
Host interface 320MB SCSI LVD

Drives 320MB SCSI 3.5 in. low profile

Supported drives 73GB 10K rpm; 73GB 15K rpm; 146GB 10K rpm; 146GB 15K rpm; 300GB 10K rpm

Maximum number of host ports
  • 3x320MB SCSI host ports (without expansion trays);
  • 2x320MB SCSI host ports (with 1 expansion tray);
  • 1x320MB SCSI host port (with 2 expansion trays)

Maximum cable lengh 12 m
Tray (12 HDDs) and RAID Array (36 HDDs) Maximum Raw Storage Capacities
73GB 10K rpm and 15K rpm HDDs 876GB per 2U tray; expandable to 2.6TB per RAID array

146GB 10K rpm and 15K rpm HDDs 1.72TB per 2U tray; expandable to 5.2TB per RAID array

300GB 10K rpm HDDs 3.60TB per 2U tray; expandable to 10.8TB per RAID array
RAID Controller Card
RAID configurations Per Tray: JBOD/Expansion (no controller); single RAID controller; dual (mirrored) RAID controllers

RAID levels 0, 1, 1+0, 3, 5, 3+0, and 5+0

Max. LUNS Up to 128 per RAID array

Max. local and/or global hot spares Up to 20 (RAID set and disk quantity dependent) per RAID array

Cache size (read and write) 512MB per controller

Cache battery backup Up to 72 hours

Cache write policy (user configurable) Write Back¡Xdefault; Write Through¡Xdefault for single controller or on battery/controller frame

Cache selectable block sizes 32K (random file transfer); 128K (sequential file transfer)

Included Management software Sun StorEdge Configuration Service; Sun StorEdge Diagnostic Reporter software Vibration 0.2 G, 5¡V500 Hz, swept-sine 1.0 G, 5¡V500 Hz, swept-sine

Optional supported software Sun StorEdge Enterprise Storage Manager, Sun StorEdge Traffic Manager, Sun Cluster 3, VERITAS NetBackup and VERITAS Volume Manager including DMP, Sun Logical Volume Manager for the Solaris 9 Operating System, Sun Solstice DiskSuite for the Solaris 8 Operating System, Sun StorEdge Resource Management, Sun StorEdge Utilization, and Sun StorEdge Performance Suites
Support Host Platforms
Suuported Hosts Servers All Sun Enterprise, Netra, and Sun Fire SPARC-based and Sun Fire x86-based servers; x86-based (Intel and AMD) third-party servers; IBM RISC-based servers; HP RISC-based servers

Supported HBAs Note: All non-Sun host bus adapters supported by third-party vendor.

Sun Solaris Operating Systems 8,9, 10 (SPARC-based) HBAs: SG-XPCI2SCSI-LM320, (X)6758A; (X)2222A; (X)4422A

Sun Solaris x86 9, 10 HBAs: (Sun Fire V60x, V65x, V20z, V40z), X9265A; SG-XPCI2SCSILM320; LSI Logic LSI22320-R

Red Hat Linux AS3.0 HBAs: (Sun Fire V60x, V65x, V20z, V40z), X9265A; SG-XPCI2SCSILM320; LSI Logic LSI22320-R

Novell SuSE Linux SLES 9 HBA: SG-XPCI2SCSI-LM320

MS Windows NT EE 4.0/2000/2003 HBAs: X9265A; SG-XPCI2SCSI-LM320; LSI Logic LSI22320-R

Novell NetWare 5.1, 6.0, 6.5 HBAs: Adaptec 39160; Adaptec 39320

HP-UX 11i HBA: HP A6829A (1st year on site, 2nd year return to depot)

IBM-AIX 5.1L HBA: IBM SYM53C1010
Reliability, Availability, Serviceability (RAS)
RAS
  • Hot-swap RAID controllers with battery-backed mirrored 512MB cache, (with dual RAID controllers)
  • 1x320MB SCSI host port (with 2 expansion trays) Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
  • Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
  • Hot-swap, redundant electrically-isolated redundant cooling fans
  • Non-disruptive firmware upgrades (with dual RAID controllers via SSCS)
Electrical Requirements
Wattage 420W each (Dual Hot-Swap Redundant Power Supplies)

AC Voltage 100 to 240 VAC, single phase

AC Power requirement 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)

AC Current per input 100 to 240 VAC, 50 to 60 Hz, 5.0¡V7.1A

DC Voltage ¡V48 or ¡V60 VDC, 18A

DC Power requirement ¡V36 to ¡V75 VDC

DC Current per input ¡V48 or ¡V60 VDC, 18A
Environment
¡@
Temperature
  • Operating: 5¢XC to 40¢XC (41¢XF to 104¢XF)
  • Nonoperating: ¡V40¢XC to 65¢XC (¡V40¢XF to 149¢XF)

Humidity (non-condensing)
  • Operating: 10% to 90% relative to 38¢X
  • Nonoperating: 0% to 90% relative to 27¢XC

Altitude
  • Operating: ¡V30m to 3048m (¡V100 to 10,000 ft.)
  • Nonoperating: ¡V30m to 12,192m (¡V100 to 40,000 ft.)

Shock
  • Operating: 5.0 G, 11-ms, half-sine
  • Nonoperating: 15.0 G, 11-ms, half-sine

Vibration
  • Operating: 0.2 G, 5¡V500 Hz, swept-sine
  • Nonoperating: 1.0 G, 5¡V500 Hz, swept-sine

Noise LWAD = 6.6 bels; LWAD (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23¢XC.
Regulations
Safety UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003

Emissions VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark

Harmonics IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001

Immunity CSIPR 24 EN 55024

Ruggedized NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386

Restriction of Hazardous Substances European Union (EU) Directive 2002/95/EC, invoking the ¡§lead-insolder¡¨ exemption, Article 4(1) paragraph 7.
Dimensions and Weight
Dimensions (Height, Width, Depth) H: 8.8 cm (3.5 in.; 2RU); W: 44.7 cm (17.6 in.); D: 53.3 cm (21 in.)

Weight (Fully Populated) 22.7 kg (50 lb.)
Warranty
Two year Sun two-year standard warranty, (1st year on site, 2nd year return to depot)

Service upgrades SunSpectrum service upgrades are available

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºSun - XTA3510R01A2Z730 - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºSun - Sun StorEdge(TM) 3510 FC Array Rack Ready, 730GB±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 NASºô¸ôÀx¦sÀɮצøªA¾¹
 ServerBank±ÀÂ˾÷ºØ
 ®à¤W«¬
 ¾÷¬[¦¡
 ª½¥ß¦¡
 ºÏºÐ°}¦C°t¥ó
 ¦Û°Ê¥úºÐ«þ¨©¾÷
 ¥~±µ¦¡µwºÐ
 ºÏ±a¾÷
 SDLT
 DLT
 LTO 1/2/3/4
 Ultrium I
 Ultrium II
 SAIT
 AIT
 AIT Turbo
 DAT
 DDS
 ºÏ±a´«±a¾÷Autoloader
 iSCSI¸Ñ¨M¤è®×
 iSCSIºÏºÐ°}¦C
 iSCSI¾ô±µ¾¹
 ºÏºÐ°}¦CRAID
 ServerBank±ÀÂ˾÷ºØ
 iSCSI
 iSCSI to SAS
 SATA
 SCSI-to-SCSI
 SCSI-to-IDE
 SCSI-to-SATA
 Fibre-to-SCSI
 Fibre-to-IDE
 Fibre-to-SATA
 Fibre-to-Fibre
 Fibre to SAS
 USB-to-IDE
 SATA-to-SATA
 SATA-to-IDE
 SAS
 IDE-to-IDE
 1394-to-IDE
 JBOD
 ºÏºÐ°}¦CÂd
 1394B-to-SATAII
 1394B-to PATA
 °ïÅ|¦¡Àx¦s¥~±µ²°
 SAS-to-SATA
 SAS-to-SAS
 SCSI-to-SAS
 PCIE
 USB
 IDE
 SAN¸Ñ¨M¤è®×
 ¥úÅÖ³q¹D¥æ´«¾¹
 ¥úÅÖ³q¹D¤¶­±¥d
 SAN Storage
 SAN Software
 ¥úÅÖ³q¹D¾ô±µ¾¹
 ¾É¦V¾¹director
 ¥úÅÖ¼Ò²Õ
 Àx¦sºÞ²z³nÅé
 ºÏ±aÂd
 ºÏ±a
 ¦Û°Ê´«¤ù¥úºÐ
 ÂÅ¥ú¥úºÐÂd
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > Àx¦s³]³Æ/³Æ¥÷¤è®×


SunXTA3510R01A2Z730

Sun StorEdge(TM) 3510 FC Array Rack Ready, 730GB


¼tµP¡GSun      >>ÂsÄýSun¥þ³¡²£«~
«¬¸¹¡GXTA3510R01A2Z730



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºSun - XTA3510R01A2Z730 - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºSun - Sun StorEdge(TM) 3510 FC Array Rack Ready, 730GB±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óSun¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§Sun²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§Sun­ì¼t°t¥ó


¡@

¡@

¡@


Sun
Sun StorEdge(TM) 3510 FC Array Rack Ready, 730GB - ServerBank¸ê°T±ÄÁʺô
XTA3510R01A2Z730
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ
Standard Interfaces
Host interface 320MB SCSI LVD

Drives 320MB SCSI 3.5 in. low profile

Supported drives 73GB 10K rpm; 73GB 15K rpm; 146GB 10K rpm; 146GB 15K rpm; 300GB 10K rpm

Maximum number of host ports
  • 3x320MB SCSI host ports (without expansion trays);
  • 2x320MB SCSI host ports (with 1 expansion tray);
  • 1x320MB SCSI host port (with 2 expansion trays)

Maximum cable lengh 12 m
Tray (12 HDDs) and RAID Array (36 HDDs) Maximum Raw Storage Capacities
73GB 10K rpm and 15K rpm HDDs 876GB per 2U tray; expandable to 2.6TB per RAID array

146GB 10K rpm and 15K rpm HDDs 1.72TB per 2U tray; expandable to 5.2TB per RAID array

300GB 10K rpm HDDs 3.60TB per 2U tray; expandable to 10.8TB per RAID array
RAID Controller Card
RAID configurations Per Tray: JBOD/Expansion (no controller); single RAID controller; dual (mirrored) RAID controllers

RAID levels 0, 1, 1+0, 3, 5, 3+0, and 5+0

Max. LUNS Up to 128 per RAID array

Max. local and/or global hot spares Up to 20 (RAID set and disk quantity dependent) per RAID array

Cache size (read and write) 512MB per controller

Cache battery backup Up to 72 hours

Cache write policy (user configurable) Write Back¡Xdefault; Write Through¡Xdefault for single controller or on battery/controller frame

Cache selectable block sizes 32K (random file transfer); 128K (sequential file transfer)

Included Management software Sun StorEdge Configuration Service; Sun StorEdge Diagnostic Reporter software Vibration 0.2 G, 5¡V500 Hz, swept-sine 1.0 G, 5¡V500 Hz, swept-sine

Optional supported software Sun StorEdge Enterprise Storage Manager, Sun StorEdge Traffic Manager, Sun Cluster 3, VERITAS NetBackup and VERITAS Volume Manager including DMP, Sun Logical Volume Manager for the Solaris 9 Operating System, Sun Solstice DiskSuite for the Solaris 8 Operating System, Sun StorEdge Resource Management, Sun StorEdge Utilization, and Sun StorEdge Performance Suites
Support Host Platforms
Suuported Hosts Servers All Sun Enterprise, Netra, and Sun Fire SPARC-based and Sun Fire x86-based servers; x86-based (Intel and AMD) third-party servers; IBM RISC-based servers; HP RISC-based servers

Supported HBAs Note: All non-Sun host bus adapters supported by third-party vendor.

Sun Solaris Operating Systems 8,9, 10 (SPARC-based) HBAs: SG-XPCI2SCSI-LM320, (X)6758A; (X)2222A; (X)4422A

Sun Solaris x86 9, 10 HBAs: (Sun Fire V60x, V65x, V20z, V40z), X9265A; SG-XPCI2SCSILM320; LSI Logic LSI22320-R

Red Hat Linux AS3.0 HBAs: (Sun Fire V60x, V65x, V20z, V40z), X9265A; SG-XPCI2SCSILM320; LSI Logic LSI22320-R

Novell SuSE Linux SLES 9 HBA: SG-XPCI2SCSI-LM320

MS Windows NT EE 4.0/2000/2003 HBAs: X9265A; SG-XPCI2SCSI-LM320; LSI Logic LSI22320-R

Novell NetWare 5.1, 6.0, 6.5 HBAs: Adaptec 39160; Adaptec 39320

HP-UX 11i HBA: HP A6829A (1st year on site, 2nd year return to depot)

IBM-AIX 5.1L HBA: IBM SYM53C1010
Reliability, Availability, Serviceability (RAS)
RAS
  • Hot-swap RAID controllers with battery-backed mirrored 512MB cache, (with dual RAID controllers)
  • 1x320MB SCSI host port (with 2 expansion trays) Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
  • Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
  • Hot-swap, redundant electrically-isolated redundant cooling fans
  • Non-disruptive firmware upgrades (with dual RAID controllers via SSCS)
Electrical Requirements
Wattage 420W each (Dual Hot-Swap Redundant Power Supplies)

AC Voltage 100 to 240 VAC, single phase

AC Power requirement 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)

AC Current per input 100 to 240 VAC, 50 to 60 Hz, 5.0¡V7.1A

DC Voltage ¡V48 or ¡V60 VDC, 18A

DC Power requirement ¡V36 to ¡V75 VDC

DC Current per input ¡V48 or ¡V60 VDC, 18A
Environment
¡@
Temperature
  • Operating: 5¢XC to 40¢XC (41¢XF to 104¢XF)
  • Nonoperating: ¡V40¢XC to 65¢XC (¡V40¢XF to 149¢XF)

Humidity (non-condensing)
  • Operating: 10% to 90% relative to 38¢X
  • Nonoperating: 0% to 90% relative to 27¢XC

Altitude
  • Operating: ¡V30m to 3048m (¡V100 to 10,000 ft.)
  • Nonoperating: ¡V30m to 12,192m (¡V100 to 40,000 ft.)

Shock
  • Operating: 5.0 G, 11-ms, half-sine
  • Nonoperating: 15.0 G, 11-ms, half-sine

Vibration
  • Operating: 0.2 G, 5¡V500 Hz, swept-sine
  • Nonoperating: 1.0 G, 5¡V500 Hz, swept-sine

Noise LWAD = 6.6 bels; LWAD (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23¢XC.
Regulations
Safety UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003

Emissions VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark

Harmonics IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001

Immunity CSIPR 24 EN 55024

Ruggedized NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386

Restriction of Hazardous Substances European Union (EU) Directive 2002/95/EC, invoking the ¡§lead-insolder¡¨ exemption, Article 4(1) paragraph 7.
Dimensions and Weight
Dimensions (Height, Width, Depth) H: 8.8 cm (3.5 in.; 2RU); W: 44.7 cm (17.6 in.); D: 53.3 cm (21 in.)

Weight (Fully Populated) 22.7 kg (50 lb.)
Warranty
Two year Sun two-year standard warranty, (1st year on site, 2nd year return to depot)

Service upgrades SunSpectrum service upgrades are available

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºSun - XTA3510R01A2Z730 - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºSun - Sun StorEdge(TM) 3510 FC Array Rack Ready, 730GB±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@