­º­¶> Àx¦s³]³Æ/³Æ¥÷¤è®×

>>ÂsÄý©Ò¦³QLOGICÀx¦s³]³Æ/³Æ¥÷¤è®×

QLOGIC
QLOGICFibre Channel Switches(QLogic 9000)

«¬¸¹¡GQLogic 9000


QLOGICQLogic 9000


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQLOGIC - QLogic 9000 - Àx¦s³]³Æ/³Æ¥÷¤è®×
³Ì¦nªºQLOGIC - QLOGICFibre Channel Switches(QLogic 9000)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óQLOGIC¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§QLOGIC²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§QLOGIC­ì¼t°t¥ó


¡@

¡@

¡@

ùþ²¤¶  EonStor A04U-G2421 ¨t列¬O¤@´Ú¥i¤ä´©

ùþ²¤¶


Designed to the Core™ for Open Systems

Changing business requirements at many of today¡¦s best companies are driving the need for the scalability, resiliency, and manageability provided by modular chassis-based SAN switches. As new and unpredictable demands spring up every quarter, these companies require the flexibility to modify and expand their server/storage infrastructure frequently without impacting production environments. In addition, as the mission-critical role of data continues to grow, more businesses than ever must guarantee iron-clad security while providing a high degree of control and monitoring.

Until now, the robust performance, rapid deployment potential, and "pay as you grow" budgeting advantages of Fibre Channel chassis switches have been available only in the form of expensive Director appliances targeted primarily at mainframe customers. IT managers with high-port-count open systems SANs who are unwilling to pay a premium for unused Director features (such as FICON support) have been forced to purchase complicated meshes of smaller switches, or very large fixed-port units ¡V both of which offer high port counts, but much less flexibility, fault tolerance, and overall system control.

QLogic now provides a new class of core switch, representing a sane alternative to quarter-million dollar Directors and large, less resilient fixed-port switches. The QLogic 9000 is Designed to the Core for cost-sensitive, business-critical, open-system environments that require high port and performance, with support for 99.999% available solutions.

¡@


QLOGIC
QLOGICFibre Channel Switches(QLogic 9000) - ServerBank¸ê°T±ÄÁʺô
QLogic 9000
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ
³W®æ
³W®æ
Fibre Channel Protocols
  • Physical Interface (FC-PI-3)
  • Line Services (FC-LS)
  • Framing & Signaling (FC-FS-2)
  • Generic Services (FC-GS/FC-GS-2/FC-GS-3/FCGS- 4/FC-GS-5)
  • Switch Fabric (FC-SW-2/FC-SW-3/FC-SW-4), except for enhanced zoning
  • Arbitrated Loop Rev. 4.6 (FC-AL)
  • Arbitrated Loop-2 Rev. 7.0 (FC-AL-2)
  • Fibre Loop Attachment (FC-FLA)
  • Tape Technical Report (FC-Tape)
  • Virtual Interface Architecture Mapping (FC-VI)
  • Fabric Element MIB Specification (RFC 2837)
  • Fibre Alliance MIB Specification (Version 4.0)
  • Methodologies for Interconnects (FC-MI-2)
  • Device Attach (FC-DA)
  • Security Protocols (FC-SP)
Fibre Channel Classes of Service
Class 2, Class 3, and Class F (inter-switch frames) connectionless Fibre Channel protocol support
Modes of Operation
  • Fabric
  • Public loop
  • Broadcast
Performance Features
Fabric Port Speed
  • 4Gb I/O Blade (SB9004-4G) @ 1.0625, 2.125, and 4.250 Gbps
    • Auto sensing of 1, 2, and 4 Gbps port speeds
    • Optionally programmable to fixed port speed
  • 8Gb I/O Blade (SB9004-8G) @ 1.0625, 2.125, 4.250, and 8.50 Gbps
    • Auto sensing of 1, 2, 4 and 8 Gbps port speeds
    • Optionally programmable to fixed port speed
  • FC10G4 I/O Blades @ 12.75 Gbps
FC Fabric Latency (Best Case)
  • 4Gb I/O blade (SB9004-4G): <0.3£gsec @ 4 Gbps
  • 8Gb I/O blade (SB9008-8G): <0.2£gsec @ 8 Gbps
  • 10Gb I/O blade (SB9010-10G): <0.2£gsec @ 10 Gbps
FC Fabric Point-to-Point Bandwidth
  • 212MB/s Full-Duplex on 1Gb ports
  • 424MB/s Full-Duplex on 2Gb ports
  • 850MB/s Full-Duplex on 4Gb ports
  • 1700MB/s Full-Duplex on 8Gb ports
  • 2550MB/s Full-Duplex on 10Gb ports
System Bandwidth
  • Backplane switching capacity
    • SB9100 Model ¡V 408 Gbps, full-duplex
    • SB9200 Model ¡V 816 Gbps, full-duplex
    • 2X SB9200 HyperStack ¡V 1632 Gbps, fullduplex
    • Non-blocking HyperStack architecture
  • Local switching capacity
    • SB9100, 4Gb blades ¡V 1088 Gbps
    • SB9100, 8Gb blades ¡V 2176 Gbps
    • SB9200. 4Gb blades ¡V 2176 Gbps
    • SB9200, 8Gb blades ¡V 4352 Gbps
Maximum Frame Sizes
  • 2148 bytes (2112 byte payload)
  • In-order delivery assured within OX-ID
Per-port Buffering
  • ASIC-embedded memory (non-shared)
  • Each port has a guaranteed 16-credit zero wait state buffer for full performance up to
    13km @ 2Gb and 2Km @ 10Gb
  • Buffer credit donor support via software GUI wizard to extend distance with full performance
Inter-Switch Link (ISL) Trunking
  • Supports aggregation of up to 128 ISLs in one or more trunks between multiple switches in
    any port speed combination and across multiple I/O Blades
    • 10Gb recommended to maximize number of usable 4/2/1Gb Server/Storage ports on
      both QLogic 5000 Series and 9000 Series switches
  • Switch-On-Exchange (SOE) mode for dynamic ISL trunk load balancing to maximize throughput
    • Assured in-order delivery of frames in all multi-switch and multi-ISL trunked configurations
    • Adaptive Trunking to improve efficiency via optimal routing across multiple trunk groups
    • Intelligent Path Selection (IPS) on all 10Gbps and 4/2/1Gbps ISL trunk ports
  • Automatic configuration of ISL trunks including multi-hop paths between multiple switches
    • Supports all multi-switch fabric topologies including stack, cascade, cascaded loop,
      and mesh
    • Adaptive Trunking to improve efficiency via optimal routing across multiple trunk groups
    • Up to 239 switches depending on configuration
  • Non-disruptive dynamic addition of ISLs to an existing trunk
  • High availability with automatic path failover
System Processor
800 MHz PowerPC processor
I/O Blade Processor
400 MHz PowerPC processor
Modular Scalability
Ports Per Chassis Module
  • 16 to 128 FC 4/2/1 Gbps ports
  • 4 to 32 FC 10 Gbps ports
  • Full Blade intermix support, maximum 8 Blades, all Blades hot-pluggable
  • >475,000 user ports depending on configuration
Ports Per Rack
Up to 1,280 ports per 42U rack
Chassis Module HyperStack
  • Two BASE Model SB9200 chassis modules via 4 proprietary HyperStack cables
    • Two domains
    • Up to 256 Fibre Channel 4/2/1 Gbps ports
Multi-switch Fabrics
  • Supports all topologies, including: stack, cascade, cascaded loop, and mesh
  • Maximum 239 switches (domain IDs) depending on configuration
Fabric Port Types
  • All ports are universal, auto-discovering, self configuring and can assume the following states:
  • F_Port: Fabric (N_Port Id Virtualization [NPIV] support automatically enabled) with up to
    255 NPIVs per port
  • FL_Port: Fabric loop (public loop)
  • E_Port: Switch-to-switch
Administrative Port Types
  • G_Port: Generic
  • GL_Port: Generic loop
Port Security
  • Port binding via list of WWNs (up to 32) allowed access to a port
  • ISL and port authentication via Fibre Channel Security Protocol (FC-SP) and DH-CHA P
Port Statistics
  • Configuration and operational data
  • Transmitted and received frame counts
  • Transmitted and received error counts
Media Type (Ordered Separately)
  • 8Gb I/O blade (SB9008-8G) ¡V Hot-pluggable, industry standard 3.3 volt SFP+ transceivers (for 8 Gbps speed) or SFP transceivers (for 4 and 2 Gbps speed)
  • 4Gb I/O blade (SB9004-4G) ¡V Hot-pluggable, industry standard 3.3 volt SFPs for 4/2/1 Gbps speeds
  • 10Gb I/O blade (SB9010-10G) ¡V Hot-pluggable, indusatry-standard X2 optical transceivers or X2 copper ISL cables for 10 Gbps speed
Supported SFP Transceiver Types
  • Short Wave (optical)
  • Long Wave (optical)
  • Active/Passive Copper (8/4/2Gb)
Supported X2 Transceiver Types
  • Short Wave (optical)
  • Long Wave (optical)
Media Transmission Ranges (@ 10Gbps speeds)
  • Optical Media
  • Short Wave: 300 m (984 ft.)
  • Long Wave: 8.34 km (5.18 miles)
Optical Cable Types (4Gb, 8Gb, and 10Gb)
  • 50/62.5 micron multimode fiber optic
  • 9 micron single-mode fiber optic
Interoperability/Certifications
Interoperability/Certifications
  • Fully interoperable with all QLogic switch products
  • Compatible with FC-SW-2 compliant switches, including Brocade, Cisco & McDATA
  • Management interoperability with leading SAN management applications
  • FCIA SANmark and SNIA SMI-S certified
  • SCD-3001v2a1 (E_Port)
  • SCD-3002v2 (FL_Port)
  • SCD-3010v1 (RSCN)
  • SCD-3020v1 (Zoning)
  • Certified with leading SAN hardware and software vendors.
    Visit: http://www.qlogic.com/interoperability/interoperability.aspx/ for a comprehensive listing
Fabric Services
Software Releases
  • QuickTools version 7.08.XX or later
  • Enterprise Fabric Suite 2007 version 7.08.XX or later
  • Switch Firmware version 7.8.XX or later
Ethernet Connections
  • CPU Blade: RJ-45 Ethernet Connector on each CPU Blade on back of chassis module
  • Maintenance Panel: Two alternate RJ-45 Ethernet Connectors on Maintenance Panel on front
    of chassis module
  • IPv6 support
Management Methods
  • Enterprise Fabric Suite 2007 Graphical User Interface (GUI)
  • QuickTools Web Applet
  • Application Programming Interface (API)
  • Command Line Interface (CLI)
  • GS-4 Management Server (including FDMI)
  • Simple Network Management Protocol (SNMP)
  • RADIUS
  • File Transfer Protocol (FTP)
  • Trivial File Transfer Protocol (TFTP)
  • Storage Management Initiative (SMI-S)
Fabric Security
  • Fabric binding via list of allowed Domain IDs and Switch WWNs
  • Inter-switch management communication data path encryption
  • Secure Shell (SSH) for CL
  • Secure Socket Layer (SSL) for QuickTools, EFS 2007, and SMI-S
  • Device, Host, and Switch Authentication
  • Local security database configuration, or
  • Remote authentication via a RADIUS Server
  • Additional MS request authentication via FCGS4 CT authentication
  • Enable/Disable in-band management of switch
Registered State Change Notification (RSCN)
  • RSCNs are generated per standard (FC-GS, FCFS, FC-SW, etc.)
  • Delayed to allow consolidation into single RSCN
  • QLogic IO StreamGuard™ suppresses RSCNs between initiators
Fabric Diagnostics
  • Optional SANdoctor software package
Maintainability
Maintenance Strategy
  • Hot-pluggable Customer Replaceable Units (CRUs) per chassis module
    • SFP & X2 transceivers
    • I/O Blades (8 maximum, 3 types w/Intermix)
    • CPU Blades (2 w/Model SB9200, 1 w/Model SB9100)
    • Power Supply Blades (2)
    • Fan Blades (2)
  • Enhanced data integrity on all data paths
  • Fabric Shortest Path First (FSPF) rerouting around failed links
  • Integration with Simple Network Management Protocol (SNMP) managers
  • Non-disruptive ¡§hot¡¨ firmware code load and activation (NDCLA)
  • Easy configuration, save, and restore
  • E-Mail Call Home system initiated alarm/fault notification
Maintenance Access Methods
  • Single point in-band management with autodiscovery across multiple switches via software GUI
  • One out-of-band Ethernet 10/100Mb BaseT RJ-45 management port per CPU Blade,
    each replicated on Maintenance Panel
  • One RJ-45 serial port per CPU Blade (RJ-45 to DB-9 conversion dongle included)
  • FC-GS4 Management Server
Diagnostics
  • Power-On Self-Test (POST) tests all functional components except SFP and X2 transceivers
  • Optional SANdoctor fabric diagnostics software
  • FC Ping: verifies functional path existence between two ports
  • FC Trace route: displays path information between a source and destination
  • Digital Diagnostics Monitoring: displays real-time SFP, X2, and XPAK transceiver data
Visual User Interface
LED indicators on the Maintenance Panel, I/O Blades, CPU Blade(s), Power Supply Blades, and Fan Blades
Maintenance Panel (MP)
Dual redundant Maintenance Panel EPROMs maintain chassis-specific information (such as WWN, SNMP System Object ID, Serial Number, Part Number, etc.), alternate Ethernet management interface ports, and LED summary status information for the switch
Global Services
Physical Characteristics
Enclosure Chassis Module/Blade Packaging
  • Standard Rack Mountable Chassis Module
  • Includes adjustable forward/reverse Mounting Rail/Racking kit & dual power cords
  • I/O Blades
  • Standard and Optional I/O Blades Do NOT Include SFPs, X2 Transceivers, or Copper/Optical
    Cables (which you can order separately)
  • Hardware and Software License Field Upgradeable:
  • SB9100 ENTRY Model to SB9200 BASE Model
  • SB9200 Model to SB9200 Fault Tolerant Model
  • One SB9200 BASE Model to Dual HyperStack Model
  • Two SB9200 BASE Models to Dual HyperStack Model
Dimensions (chassis module)
  • Width: 431 mm (17.0") 19" rack mountable
  • Height: 179 mm (7.0") (4U)
  • Depth: 673 mm (26.5")
Weight (SB9200 chassis module maximum)
  • 40.82 kg (90 lbs)
Power Supply/Cooling (both SB9100 & SB9200)
  • Hot-Pluggable/Dual-Redundant Power Supply Blades with Integrated Cooling Fans
  • Dual 76" long 3-wire 16AWG power cables with IEC320 input connector
  • Popular internet and country dual power cable/connector kit options available
  • Hot-Pluggable/Dual-Redundant Fan Blades
  • Back-to-Front and Front-to-Back Airflow Direction Models available
  • 150-cfm airflow
  • 1,000 watts or 3,414 BTU/hour rating per power supply
Heat Output (SB9200 full data traffic maximum)
  • 2,046 BTU/hour at 128-ports 4-Gb Fibre Channel (SFPs and "local switching")
  • 4,228 BTU/hour at 256-ports 4-Gb Fibre Channel HyperStack (SFPs and "local switching")
Electrical Requirements
Operating Voltage/Frequency
  • 100 to 240 VAC auto-sensing, single phase
  • 47 to 63Hz
Power Source Loading (SB9200 chassis module maximum power supply rating)
  • 10 Amps at 100 VAC
  • 4.2 Amps at 240 VAC
Operating Load (SB9200 with no data traffic)
  • 550 Watts at 128-ports 4Gb Fibre Channel (including SFPs)
  • 1,120 watts at 256-ports 4-Gb Fibre Channel HyperStack (including SFPs)
Operating Load (SB9200 with full data traffic)
  • 600 Watts at 128-ports 4Gb Fibre Channel (including SFPs and "local switching")
  • 1,240 watts at 256-ports 4-Gb Fibre Channel HyperStack (including SFPs and "local switching")
  • Circuit Protection
  • Internally fused
Circuit Protection
  • Internally fused
Environmental Factors
Operating
  • Temperature: 0¢XC to 40¢XC (32¢X to 104¢XF)
  • Humidity: 15% to 80% non-condensing
  • Altitude: 0 to 3048m (0 to 10,000 feet)
  • Vibration: IEC 68-2, 5-500 Hz, random, 0.21g RMS, 10 minutes
  • Shock: IEC 68-2: 4g, 11ms, 20 repetitions
Non-Operating
  • Temperature: -40¢XC to 70¢XC (-40¢X to 158 ¢XF)
  • Humidity: 5% to 90% non-condensing
  • Altitude: 0 to 15,240m (0 to 50,000 feet)
  • Vibration: IEC 68-2: 5-500 Hz, random, 2.1g RMS,10 minutes
  • Shock: IEC 68-2: 30g, 13 msec, trapezoidal pulse
Regulatory Certifications
Safety Standards
  • UL 60950-1 ¡V UL Listed (United States)
  • CAN/CSA C22.2 No. 60950-1 ¡V cUL Listed (Canada)
  • EN60950-1 (EC)
  • CB Scheme-IEC 60950-1 (International)
  • GOST R (Russia)
Emissions Standards
  • FCC Part 15B Class A (USA)
  • VCCI Class A ITE (Japan)
  • ICES-003 Class A ITE (Canada)
  • EN 55022 Level A (EC)
  • CISPR 22, Class A (International)
  • AS/NZS CISPR 22:2002 Class A (AUS/NZ)
  • GOST R (Russia)
  • KN22 ¡V Class A (Korea)
Environmental Standards
  • RoHS-5/WEE (EU & Japan)
Voltage Fluctuations
  • EN 61000-3-3
Harmonics
  • EN 61000-3-2
Immunity
  • EN 55024
Marking
  • FCC Part 15, UL (United States)
  • cUL, CUE, TUV (Canada)
  • TUV , CUE, CE (EC)
  • VCCI-A (Japan)
  • C-Tick (AUS/NZ)
  • GOST R (Russia)
  • MIC (Korea)
  • Exempt (Taiwan)
  • UL AR/S-Mark (Argentina)
  • CCC ¡V Field replaceable unit (FRU) power supply modules (China)

¡@


¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQLOGIC - QLogic 9000 - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºQLOGIC - QLOGICFibre Channel Switches(QLogic 9000)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 NASºô¸ôÀx¦sÀɮצøªA¾¹
 ServerBank±ÀÂ˾÷ºØ
 ®à¤W«¬
 ¾÷¬[¦¡
 ª½¥ß¦¡
 ºÏºÐ°}¦C°t¥ó
 ¦Û°Ê¥úºÐ«þ¨©¾÷
 ¥~±µ¦¡µwºÐ
 ºÏ±a¾÷
 SDLT
 DLT
 LTO 1/2/3/4
 Ultrium I
 Ultrium II
 SAIT
 AIT
 AIT Turbo
 DAT
 DDS
 ºÏ±a´«±a¾÷Autoloader
 iSCSI¸Ñ¨M¤è®×
 iSCSIºÏºÐ°}¦C
 iSCSI¾ô±µ¾¹
 ºÏºÐ°}¦CRAID
 ServerBank±ÀÂ˾÷ºØ
 iSCSI
 iSCSI to SAS
 SATA
 SCSI-to-SCSI
 SCSI-to-IDE
 SCSI-to-SATA
 Fibre-to-SCSI
 Fibre-to-IDE
 Fibre-to-SATA
 Fibre-to-Fibre
 Fibre to SAS
 USB-to-IDE
 SATA-to-SATA
 SATA-to-IDE
 SAS
 IDE-to-IDE
 1394-to-IDE
 JBOD
 ºÏºÐ°}¦CÂd
 1394B-to-SATAII
 1394B-to PATA
 °ïÅ|¦¡Àx¦s¥~±µ²°
 SAS-to-SATA
 SAS-to-SAS
 SCSI-to-SAS
 PCIE
 USB
 IDE
 SAN¸Ñ¨M¤è®×
 ¥úÅÖ³q¹D¥æ´«¾¹
 ¥úÅÖ³q¹D¤¶­±¥d
 SAN Storage
 SAN Software
 ¥úÅÖ³q¹D¾ô±µ¾¹
 ¾É¦V¾¹director
 ¥úÅÖ¼Ò²Õ
 Àx¦sºÞ²z³nÅé
 ºÏ±aÂd
 ºÏ±a
 ¦Û°Ê´«¤ù¥úºÐ
 ÂÅ¥ú¥úºÐÂd
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > Àx¦s³]³Æ/³Æ¥÷¤è®×


QLOGICQLogic 9000

QLOGICFibre Channel Switches(QLogic 9000)


¼tµP¡GQLOGIC      >>ÂsÄýQLOGIC¥þ³¡²£«~
«¬¸¹¡GQLogic 9000



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQLOGIC - QLogic 9000 - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºQLOGIC - QLOGICFibre Channel Switches(QLogic 9000)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óQLOGIC¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§QLOGIC²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§QLOGIC­ì¼t°t¥ó


¡@

¡@

¡@

ùþ²¤¶  EonStor A04U-G2421 ¨t列¬O¤@´Ú¥i¤ä´©

ùþ²¤¶


Designed to the Core™ for Open Systems

Changing business requirements at many of today¡¦s best companies are driving the need for the scalability, resiliency, and manageability provided by modular chassis-based SAN switches. As new and unpredictable demands spring up every quarter, these companies require the flexibility to modify and expand their server/storage infrastructure frequently without impacting production environments. In addition, as the mission-critical role of data continues to grow, more businesses than ever must guarantee iron-clad security while providing a high degree of control and monitoring.

Until now, the robust performance, rapid deployment potential, and "pay as you grow" budgeting advantages of Fibre Channel chassis switches have been available only in the form of expensive Director appliances targeted primarily at mainframe customers. IT managers with high-port-count open systems SANs who are unwilling to pay a premium for unused Director features (such as FICON support) have been forced to purchase complicated meshes of smaller switches, or very large fixed-port units ¡V both of which offer high port counts, but much less flexibility, fault tolerance, and overall system control.

QLogic now provides a new class of core switch, representing a sane alternative to quarter-million dollar Directors and large, less resilient fixed-port switches. The QLogic 9000 is Designed to the Core for cost-sensitive, business-critical, open-system environments that require high port and performance, with support for 99.999% available solutions.

¡@


QLOGIC
QLOGICFibre Channel Switches(QLogic 9000) - ServerBank¸ê°T±ÄÁʺô
QLogic 9000
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ
³W®æ
³W®æ
Fibre Channel Protocols
  • Physical Interface (FC-PI-3)
  • Line Services (FC-LS)
  • Framing & Signaling (FC-FS-2)
  • Generic Services (FC-GS/FC-GS-2/FC-GS-3/FCGS- 4/FC-GS-5)
  • Switch Fabric (FC-SW-2/FC-SW-3/FC-SW-4), except for enhanced zoning
  • Arbitrated Loop Rev. 4.6 (FC-AL)
  • Arbitrated Loop-2 Rev. 7.0 (FC-AL-2)
  • Fibre Loop Attachment (FC-FLA)
  • Tape Technical Report (FC-Tape)
  • Virtual Interface Architecture Mapping (FC-VI)
  • Fabric Element MIB Specification (RFC 2837)
  • Fibre Alliance MIB Specification (Version 4.0)
  • Methodologies for Interconnects (FC-MI-2)
  • Device Attach (FC-DA)
  • Security Protocols (FC-SP)
Fibre Channel Classes of Service
Class 2, Class 3, and Class F (inter-switch frames) connectionless Fibre Channel protocol support
Modes of Operation
  • Fabric
  • Public loop
  • Broadcast
Performance Features
Fabric Port Speed
  • 4Gb I/O Blade (SB9004-4G) @ 1.0625, 2.125, and 4.250 Gbps
    • Auto sensing of 1, 2, and 4 Gbps port speeds
    • Optionally programmable to fixed port speed
  • 8Gb I/O Blade (SB9004-8G) @ 1.0625, 2.125, 4.250, and 8.50 Gbps
    • Auto sensing of 1, 2, 4 and 8 Gbps port speeds
    • Optionally programmable to fixed port speed
  • FC10G4 I/O Blades @ 12.75 Gbps
FC Fabric Latency (Best Case)
  • 4Gb I/O blade (SB9004-4G): <0.3£gsec @ 4 Gbps
  • 8Gb I/O blade (SB9008-8G): <0.2£gsec @ 8 Gbps
  • 10Gb I/O blade (SB9010-10G): <0.2£gsec @ 10 Gbps
FC Fabric Point-to-Point Bandwidth
  • 212MB/s Full-Duplex on 1Gb ports
  • 424MB/s Full-Duplex on 2Gb ports
  • 850MB/s Full-Duplex on 4Gb ports
  • 1700MB/s Full-Duplex on 8Gb ports
  • 2550MB/s Full-Duplex on 10Gb ports
System Bandwidth
  • Backplane switching capacity
    • SB9100 Model ¡V 408 Gbps, full-duplex
    • SB9200 Model ¡V 816 Gbps, full-duplex
    • 2X SB9200 HyperStack ¡V 1632 Gbps, fullduplex
    • Non-blocking HyperStack architecture
  • Local switching capacity
    • SB9100, 4Gb blades ¡V 1088 Gbps
    • SB9100, 8Gb blades ¡V 2176 Gbps
    • SB9200. 4Gb blades ¡V 2176 Gbps
    • SB9200, 8Gb blades ¡V 4352 Gbps
Maximum Frame Sizes
  • 2148 bytes (2112 byte payload)
  • In-order delivery assured within OX-ID
Per-port Buffering
  • ASIC-embedded memory (non-shared)
  • Each port has a guaranteed 16-credit zero wait state buffer for full performance up to
    13km @ 2Gb and 2Km @ 10Gb
  • Buffer credit donor support via software GUI wizard to extend distance with full performance
Inter-Switch Link (ISL) Trunking
  • Supports aggregation of up to 128 ISLs in one or more trunks between multiple switches in
    any port speed combination and across multiple I/O Blades
    • 10Gb recommended to maximize number of usable 4/2/1Gb Server/Storage ports on
      both QLogic 5000 Series and 9000 Series switches
  • Switch-On-Exchange (SOE) mode for dynamic ISL trunk load balancing to maximize throughput
    • Assured in-order delivery of frames in all multi-switch and multi-ISL trunked configurations
    • Adaptive Trunking to improve efficiency via optimal routing across multiple trunk groups
    • Intelligent Path Selection (IPS) on all 10Gbps and 4/2/1Gbps ISL trunk ports
  • Automatic configuration of ISL trunks including multi-hop paths between multiple switches
    • Supports all multi-switch fabric topologies including stack, cascade, cascaded loop,
      and mesh
    • Adaptive Trunking to improve efficiency via optimal routing across multiple trunk groups
    • Up to 239 switches depending on configuration
  • Non-disruptive dynamic addition of ISLs to an existing trunk
  • High availability with automatic path failover
System Processor
800 MHz PowerPC processor
I/O Blade Processor
400 MHz PowerPC processor
Modular Scalability
Ports Per Chassis Module
  • 16 to 128 FC 4/2/1 Gbps ports
  • 4 to 32 FC 10 Gbps ports
  • Full Blade intermix support, maximum 8 Blades, all Blades hot-pluggable
  • >475,000 user ports depending on configuration
Ports Per Rack
Up to 1,280 ports per 42U rack
Chassis Module HyperStack
  • Two BASE Model SB9200 chassis modules via 4 proprietary HyperStack cables
    • Two domains
    • Up to 256 Fibre Channel 4/2/1 Gbps ports
Multi-switch Fabrics
  • Supports all topologies, including: stack, cascade, cascaded loop, and mesh
  • Maximum 239 switches (domain IDs) depending on configuration
Fabric Port Types
  • All ports are universal, auto-discovering, self configuring and can assume the following states:
  • F_Port: Fabric (N_Port Id Virtualization [NPIV] support automatically enabled) with up to
    255 NPIVs per port
  • FL_Port: Fabric loop (public loop)
  • E_Port: Switch-to-switch
Administrative Port Types
  • G_Port: Generic
  • GL_Port: Generic loop
Port Security
  • Port binding via list of WWNs (up to 32) allowed access to a port
  • ISL and port authentication via Fibre Channel Security Protocol (FC-SP) and DH-CHA P
Port Statistics
  • Configuration and operational data
  • Transmitted and received frame counts
  • Transmitted and received error counts
Media Type (Ordered Separately)
  • 8Gb I/O blade (SB9008-8G) ¡V Hot-pluggable, industry standard 3.3 volt SFP+ transceivers (for 8 Gbps speed) or SFP transceivers (for 4 and 2 Gbps speed)
  • 4Gb I/O blade (SB9004-4G) ¡V Hot-pluggable, industry standard 3.3 volt SFPs for 4/2/1 Gbps speeds
  • 10Gb I/O blade (SB9010-10G) ¡V Hot-pluggable, indusatry-standard X2 optical transceivers or X2 copper ISL cables for 10 Gbps speed
Supported SFP Transceiver Types
  • Short Wave (optical)
  • Long Wave (optical)
  • Active/Passive Copper (8/4/2Gb)
Supported X2 Transceiver Types
  • Short Wave (optical)
  • Long Wave (optical)
Media Transmission Ranges (@ 10Gbps speeds)
  • Optical Media
  • Short Wave: 300 m (984 ft.)
  • Long Wave: 8.34 km (5.18 miles)
Optical Cable Types (4Gb, 8Gb, and 10Gb)
  • 50/62.5 micron multimode fiber optic
  • 9 micron single-mode fiber optic
Interoperability/Certifications
Interoperability/Certifications
  • Fully interoperable with all QLogic switch products
  • Compatible with FC-SW-2 compliant switches, including Brocade, Cisco & McDATA
  • Management interoperability with leading SAN management applications
  • FCIA SANmark and SNIA SMI-S certified
  • SCD-3001v2a1 (E_Port)
  • SCD-3002v2 (FL_Port)
  • SCD-3010v1 (RSCN)
  • SCD-3020v1 (Zoning)
  • Certified with leading SAN hardware and software vendors.
    Visit: http://www.qlogic.com/interoperability/interoperability.aspx/ for a comprehensive listing
Fabric Services
Software Releases
  • QuickTools version 7.08.XX or later
  • Enterprise Fabric Suite 2007 version 7.08.XX or later
  • Switch Firmware version 7.8.XX or later
Ethernet Connections
  • CPU Blade: RJ-45 Ethernet Connector on each CPU Blade on back of chassis module
  • Maintenance Panel: Two alternate RJ-45 Ethernet Connectors on Maintenance Panel on front
    of chassis module
  • IPv6 support
Management Methods
  • Enterprise Fabric Suite 2007 Graphical User Interface (GUI)
  • QuickTools Web Applet
  • Application Programming Interface (API)
  • Command Line Interface (CLI)
  • GS-4 Management Server (including FDMI)
  • Simple Network Management Protocol (SNMP)
  • RADIUS
  • File Transfer Protocol (FTP)
  • Trivial File Transfer Protocol (TFTP)
  • Storage Management Initiative (SMI-S)
Fabric Security
  • Fabric binding via list of allowed Domain IDs and Switch WWNs
  • Inter-switch management communication data path encryption
  • Secure Shell (SSH) for CL
  • Secure Socket Layer (SSL) for QuickTools, EFS 2007, and SMI-S
  • Device, Host, and Switch Authentication
  • Local security database configuration, or
  • Remote authentication via a RADIUS Server
  • Additional MS request authentication via FCGS4 CT authentication
  • Enable/Disable in-band management of switch
Registered State Change Notification (RSCN)
  • RSCNs are generated per standard (FC-GS, FCFS, FC-SW, etc.)
  • Delayed to allow consolidation into single RSCN
  • QLogic IO StreamGuard™ suppresses RSCNs between initiators
Fabric Diagnostics
  • Optional SANdoctor software package
Maintainability
Maintenance Strategy
  • Hot-pluggable Customer Replaceable Units (CRUs) per chassis module
    • SFP & X2 transceivers
    • I/O Blades (8 maximum, 3 types w/Intermix)
    • CPU Blades (2 w/Model SB9200, 1 w/Model SB9100)
    • Power Supply Blades (2)
    • Fan Blades (2)
  • Enhanced data integrity on all data paths
  • Fabric Shortest Path First (FSPF) rerouting around failed links
  • Integration with Simple Network Management Protocol (SNMP) managers
  • Non-disruptive ¡§hot¡¨ firmware code load and activation (NDCLA)
  • Easy configuration, save, and restore
  • E-Mail Call Home system initiated alarm/fault notification
Maintenance Access Methods
  • Single point in-band management with autodiscovery across multiple switches via software GUI
  • One out-of-band Ethernet 10/100Mb BaseT RJ-45 management port per CPU Blade,
    each replicated on Maintenance Panel
  • One RJ-45 serial port per CPU Blade (RJ-45 to DB-9 conversion dongle included)
  • FC-GS4 Management Server
Diagnostics
  • Power-On Self-Test (POST) tests all functional components except SFP and X2 transceivers
  • Optional SANdoctor fabric diagnostics software
  • FC Ping: verifies functional path existence between two ports
  • FC Trace route: displays path information between a source and destination
  • Digital Diagnostics Monitoring: displays real-time SFP, X2, and XPAK transceiver data
Visual User Interface
LED indicators on the Maintenance Panel, I/O Blades, CPU Blade(s), Power Supply Blades, and Fan Blades
Maintenance Panel (MP)
Dual redundant Maintenance Panel EPROMs maintain chassis-specific information (such as WWN, SNMP System Object ID, Serial Number, Part Number, etc.), alternate Ethernet management interface ports, and LED summary status information for the switch
Global Services
Physical Characteristics
Enclosure Chassis Module/Blade Packaging
  • Standard Rack Mountable Chassis Module
  • Includes adjustable forward/reverse Mounting Rail/Racking kit & dual power cords
  • I/O Blades
  • Standard and Optional I/O Blades Do NOT Include SFPs, X2 Transceivers, or Copper/Optical
    Cables (which you can order separately)
  • Hardware and Software License Field Upgradeable:
  • SB9100 ENTRY Model to SB9200 BASE Model
  • SB9200 Model to SB9200 Fault Tolerant Model
  • One SB9200 BASE Model to Dual HyperStack Model
  • Two SB9200 BASE Models to Dual HyperStack Model
Dimensions (chassis module)
  • Width: 431 mm (17.0") 19" rack mountable
  • Height: 179 mm (7.0") (4U)
  • Depth: 673 mm (26.5")
Weight (SB9200 chassis module maximum)
  • 40.82 kg (90 lbs)
Power Supply/Cooling (both SB9100 & SB9200)
  • Hot-Pluggable/Dual-Redundant Power Supply Blades with Integrated Cooling Fans
  • Dual 76" long 3-wire 16AWG power cables with IEC320 input connector
  • Popular internet and country dual power cable/connector kit options available
  • Hot-Pluggable/Dual-Redundant Fan Blades
  • Back-to-Front and Front-to-Back Airflow Direction Models available
  • 150-cfm airflow
  • 1,000 watts or 3,414 BTU/hour rating per power supply
Heat Output (SB9200 full data traffic maximum)
  • 2,046 BTU/hour at 128-ports 4-Gb Fibre Channel (SFPs and "local switching")
  • 4,228 BTU/hour at 256-ports 4-Gb Fibre Channel HyperStack (SFPs and "local switching")
Electrical Requirements
Operating Voltage/Frequency
  • 100 to 240 VAC auto-sensing, single phase
  • 47 to 63Hz
Power Source Loading (SB9200 chassis module maximum power supply rating)
  • 10 Amps at 100 VAC
  • 4.2 Amps at 240 VAC
Operating Load (SB9200 with no data traffic)
  • 550 Watts at 128-ports 4Gb Fibre Channel (including SFPs)
  • 1,120 watts at 256-ports 4-Gb Fibre Channel HyperStack (including SFPs)
Operating Load (SB9200 with full data traffic)
  • 600 Watts at 128-ports 4Gb Fibre Channel (including SFPs and "local switching")
  • 1,240 watts at 256-ports 4-Gb Fibre Channel HyperStack (including SFPs and "local switching")
  • Circuit Protection
  • Internally fused
Circuit Protection
  • Internally fused
Environmental Factors
Operating
  • Temperature: 0¢XC to 40¢XC (32¢X to 104¢XF)
  • Humidity: 15% to 80% non-condensing
  • Altitude: 0 to 3048m (0 to 10,000 feet)
  • Vibration: IEC 68-2, 5-500 Hz, random, 0.21g RMS, 10 minutes
  • Shock: IEC 68-2: 4g, 11ms, 20 repetitions
Non-Operating
  • Temperature: -40¢XC to 70¢XC (-40¢X to 158 ¢XF)
  • Humidity: 5% to 90% non-condensing
  • Altitude: 0 to 15,240m (0 to 50,000 feet)
  • Vibration: IEC 68-2: 5-500 Hz, random, 2.1g RMS,10 minutes
  • Shock: IEC 68-2: 30g, 13 msec, trapezoidal pulse
Regulatory Certifications
Safety Standards
  • UL 60950-1 ¡V UL Listed (United States)
  • CAN/CSA C22.2 No. 60950-1 ¡V cUL Listed (Canada)
  • EN60950-1 (EC)
  • CB Scheme-IEC 60950-1 (International)
  • GOST R (Russia)
Emissions Standards
  • FCC Part 15B Class A (USA)
  • VCCI Class A ITE (Japan)
  • ICES-003 Class A ITE (Canada)
  • EN 55022 Level A (EC)
  • CISPR 22, Class A (International)
  • AS/NZS CISPR 22:2002 Class A (AUS/NZ)
  • GOST R (Russia)
  • KN22 ¡V Class A (Korea)
Environmental Standards
  • RoHS-5/WEE (EU & Japan)
Voltage Fluctuations
  • EN 61000-3-3
Harmonics
  • EN 61000-3-2
Immunity
  • EN 55024
Marking
  • FCC Part 15, UL (United States)
  • cUL, CUE, TUV (Canada)
  • TUV , CUE, CE (EC)
  • VCCI-A (Japan)
  • C-Tick (AUS/NZ)
  • GOST R (Russia)
  • MIC (Korea)
  • Exempt (Taiwan)
  • UL AR/S-Mark (Argentina)
  • CCC ¡V Field replaceable unit (FRU) power supply modules (China)

¡@


¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQLOGIC - QLogic 9000 - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºQLOGIC - QLOGICFibre Channel Switches(QLogic 9000)±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@