High-speed, Layer 2 Managed
Gigabit Switching
NETGEAR delivers wirespeed Gigabit
performance and a full set of Layer 2
management features with unsurpassed
affordability. These next-generation,
high-speed switches deliver maximum
throughput where you need it ¡X to
high-performance workgroups at the edge
of the network, or as a backbone for
Fast Ethernet switches and high-speed
servers in demanding small networks. The
non-blocking design offers full Gigabit
throughput simultaneously to all 12, 24
or 48 10/100/1000 ports to ensure
reliable performance. Powerful
Full 12, 24 or 48 10/100/1000 ports and
a non-blocking design provide wire speed
throughput and maximum bandwidth for the
most demanding network environments.
Small Form-factor Pluggable (SFP)
modules deliver choice in 1000Base-SX,
1000Base-LX or 1000Base-ZX (70Km)
optics. The Layer 2 management features
optimize bandwidth throughout the
network ¡V delivering Gigabit performance
to systems, applications, and services.
Take advantage of forwarding rates up to
71.4 million pps, and a switching
capacity of 96 Gbps.
Easy to Use
Move up to Gigabit power in minutes. Use
any of these solutions as a managed
switch out of the box ¡V just plug and
play! All ports are auto-negotiating and
support Auto Uplink™ technology. Choose
from two easy-to-use management
interface options ¡VWeb interface or a
command line interface available through
console or Telnet. Comprehensive remote
administration capabilities reduce the
need for on-site administration. Easy to
troubleshoot ¡V built-in testing
capability locates cable related network
problems.
Manageable
Meet your management needs with SNMP
(v1, v2c and v3), RMON, Command-Line
Interface (CLI) and complete Web-based
GUI. Advanced features include up to 512
VLANs, DiffServ traffic prioritization
and 802.1p (QoS) for Voice over IP
services (VoIP), broadcast storm
protection, RADIUS, 802.1x, port
trunking, rapid spanning tree, and link
aggregation. Full Layer 2 implementation
allows you to configure your network for
maximum performance, reliability, and
availability. Manageable with any
popular SNMP-based management software,
but optimized for NETGEAR
ProSafe Network Management Software
NMS100.
Outstanding
Layer 2 management and full Gigabit
power at a compelling price. Use at the
edge to improve workgroup connections,
or at the core to upgrade a Gigabit
Ethernet backbone ¡X now you can afford
the power your network deserves. Like
all NETGEAR products, everything you
need is in the box ¡V including rack
mount kit, power and serial cables, and
more.
|
NETGEAR ENTRY LEVEL 24-PORT 10/100/1000 MBPS -GSM7224 - ServerBank¸ê°T±ÄÁʺô GSM7224 ºô¸ô³]³Æ/ÀW¼eºÞ²z
¡@
Physical Interfaces
- RJ-45 Connectors for 10BASE-T,
100BASE-TX, and 1000BASE-T (Auto
Uplink™ on all ports):
GSM7212: 12 ports
GSM7224: 24 ports
GSM7248: 48 ports
- Small form-factor pluggable
(SFP) modules for fiber Gigabit
Ethernet interfaces:
GSM7212: 12 slots
GSM7224: 4 slots
GSM7248: 4 slots
- RS-232 Console Port
Layer 2 Services
- IEEE 802.1Q static VLAN (512)
- IEEE 802.1p Class of Service
(CoS)
- IEEE 802.1D Spanning Tree
Protocol
- IEEE 802.1v protocol VLAN & port
VLAN
- IEEE 802.1w Rapid Spanning Tree
- IEEE 802.1s Multiple Spanning
Tree
- IEEE 802.3ad Link Aggregation
(LACP)
- IEEE 802.1x port access
authentication
- IGMP v1, v2 snooping support
- Network storm protection
including broadcast, multicast and
unicast traffic
- Static multicast filtering
- Weighted round robin (WRR) query
technology
Switch Management
Specifications
- SNMP v1, v2c, v3 with multiple
IP addresses
- RFC 1157, 1902-1907
- RFC 768 UDP
- UDP relay
- RFC 854-859 telnet
- RFC 951 BOOTP
- RFC 1213 MIB II
- RFC 1757 RMON groups 1,2,3, and
9
- RFC 1215 SNMP traps
- RFC 1493 Bridge MIB
- RFC 1643 Ethernet Interface MIB
- RFC 1534 DHCP and BOOTP
interoperation
- RFC 2131, 2132 DHCP and BOOTP
- RFC 2865 RADIUS (both switch and
management access)
- RFC 2866 RADIUS accounting
- Private Enterprise MIB
- Port mirroring support
(many-to-one)
- RFC 2236 IGMP v2
- IGMP querier
- DHCP/BOOTP relay primary and
backup (RFC3046, option 82)
- RFC 2030 Simple Network Time
Protocol (SNTP)
- SYSLOG
- Firmware upgrade via TFTP or
HTTP
- Port description
GSM7248 only:
- Ingress rate limit in 1 Kbps
increments
- DiffServ QoS (RFC 2998)
- L3 prioritization
- L4 prioritization
- Policy-based QoS
- IEEE 802.1 QinQ
- Access control lists (ACL, MAC,
IP)
Performance Specifications
- Forwarding modes:
Store-and-forward
- Bandwidth:
GSM7212: 24 Gbps; 17.8 Mpps
GSM7224: 48 Gbps; 35.7 Mpps
GSM7248: 96 Gbps; 71.4 Mpps
- Switch latency: 20 £gs for
64-byte frames (1G to 1G)
- System memory: 64 MB
- Packet buffer memory: 122 KB
embedded memory per port
- Code storage (flash): 8 MB
- MAC address database size:
GSM7212: 8 K
GSM7224: 8 K
GSM7248: 16 K
- Number of VLANs:
GSM7212: 228
GSM7224: 228
GSM7248: 240
- Number of trunks: 6
- Number of queues: 8
- Jumbo frame support: up to 9K
packet size
- Acoustic noise:
GSM7212: 41.6 dB
GSM7224: 60 dB
GSM7248: 47 dB
- Heat Dissipation: 28.24 BTU/hr
- Mean time between failure
(MTBF):
GSM7212: 61,349 hours (>7 years)
GSM7224: 58,300 hours (>6.6 years)
GSM7248: 58,300 hours (>6.6 years)
- User Interfaces
- Command Line Interface (CLI) via
console port (4 sessions)
- Web-based management via
embedded HTTP server protected with
Secure Sockets Layer
- (SSLv3) or Transport Layer
Security (TLSv1)
- Telnet remote login (5 sessions)
securable with Secure Shell (SSH
v1.5, v2)
LEDs
- Per port: Speed, link, activity
- Per device: Power, fan status
Network Standards
Compatibility
- IEEE 802.3i 10BASE-T
- IEEE 802.3u 100BASE-TX
- IEEE 802.3ab 1000BASE-T
- IEEE 802.3z 1000BASE-X
- IEEE 802.3x flow control
Physical Specifications
- Dimensions (w x d x h): 440 x
257 x 43 mm (17.32 x 10.2 x 1.7 in)
- Weight: 4.2 kg (9.2 lb)
Environmental Specifications
- Operating temperature: 0¢X to 40¢X
C (32 to 104¢X F)
- Storage temperature: -20¢X to 70¢X
C (-4 to 158¢X F)
- Operating humidity: 90% maximum
relative humidity, non-condensing
- Storage humidity: 95% maximum
relative humidity, non-condensing
- Operating altitude: 3,000 m
(10,000 ft) maximum
- Storage altitude: 3,000 m
(10,000 ft) maximum
Electrical Specifications
- Power Consumption:
GSM7212 20.7W maximum
GSM7224 42.9W maximum
GSM7248 99W maximum
- Electromagnetic emissions
- CE mark
- EN 55022 Class A - Emissions
- EN 55024 - Immunity
- FCC Part 15 Class A
- VCCI Class A
- C-Tick
Electromagnetic
Safety
- CE mark
- EN 60950-1
- UL/cUL 60950-1
Modules
- ProSafe AGM731F 1000BASE-SX SFP
GBIC
- ProSafe AGM732F 1000BASE-LX SFP
GBIC
- ProSafe AGM733 1000BASE-ZX SFP
GBIC
Warranty
- NETGEAR Lifetime Warranty†
Package Contents
- ProSafe Gigabit L2 Managed
Switch (GSM7212, GSM7224 or GSM7248)
- Null modem cable
- Rubber footpads
- Power cable
- Rack-mount kit
- Installation guide
- Resource CD-ROM
- Warranty/support information
card
Ordering Information
- North America
GSM7212NA
GSM7224NA
GSM7248NA
- Europe
GSM7212EU
GSM7224EU
GSM7248EU
- Asia
GSM7212AU
GSM7224AU
GSM7248AU
- Japan
GSM7212JP
GSM7224JP
GSM7248JP
ProSupport Service Packs
Available
GSM7212 & GSM7224
OnCall 24x7, Category 2
XPressHW, Category 2
GSM7248
OnCall 24x7, Category 3
XPressHW, Category 3
¡@ |
|
¡D¥»¤å¥óªº¸ê°TY¦³×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ùY¦³»~¡A¥Hì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨äì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C
º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á!
ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶WÈÀu´fªºNETGEAR - GSM7224 - ºô¸ô³]³Æ/ÀW¼eºÞ²z
,³Ì¦nªºNETGEAR - ENTRY LEVEL 24-PORT 10/100/1000 MBPS -GSM7224±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
|
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§ÚÌ·|¬°±z¦Vì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú̳£¥i¼u©Ê°t¦X±zªº»Ýn³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G
1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901 |
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»¶ÁʶR¸ß»ù§ÚÌ·|¥ß§Y»P±zÁpô! |
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw |
|
¥I´Ú¤è¦¡¡G¦p«È¤á¬°º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C |
¶Ç¯uq³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨qÁʵ{§Ç¡A§ÚÌ·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{q³æ¡C |
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú̦¬¨ì±zq³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C |
°e³f¤è¦¡¡G(1) ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C |
°e³f½d³ò¡G¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±zt¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C |
°â«áªA°È¡GY²£«~¥»¨·å²«©Î¹B°e¹Lµ{¾ÉP·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C |
«O©T¬Fµ¦¡G ¹ê»Ú¥Hì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C |
¤O±ô¸ê°T ServerBank Inc. ²¤¶
¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G
»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶Û¡B¥xÆWªFªÛ¡B¥xÆW^¸â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B
¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B
ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B
¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B
Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B
¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B
´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B¸ºÐ¼s¼½¡B·¼é°Û¤ù¡B®É³ø©P¥Z¡B
±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B
²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡Bì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°
¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B
ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B
¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B
¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤±]±¶¹B¡B¥xÆW´¼¼z¥d¡B
¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½^¡B¿ßÀYÆN
©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B
x¤è¡G ªÅx¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B
|
|
|
|
|
|
|
¡@ |
|