­º­¶> ºô¸ô³]³Æ/ÀW¼eºÞ²z

>>ÂsÄý©Ò¦³ALCATELºô¸ô³]³Æ/ÀW¼eºÞ²z

ALCATEL
Alcatel-Lucent OmniSwitch 6855 Ethernet Hardened LAN Switch OS6855-24

«¬¸¹¡GOS6855-24


ALCATELOS6855-24


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºALCATEL - OS6855-24 - ºô¸ô³]³Æ/ÀW¼eºÞ²z
³Ì¦nªºALCATEL - Alcatel-Lucent OmniSwitch 6855 Ethernet Hardened LAN Switch OS6855-24±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Úºô¸ô³]³Æ/ÀW¼eºÞ²z Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óALCATEL¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§ALCATEL²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§ALCATEL­ì¼t°t¥ó


¡@

¡@

¡@

²£«~¯S¦â
  • Purpose built, industrial strength, engineered to operate in temperatures ranging from -40C up to + 75C

  • Convection cooling fan-less design that offers increased reliability and lower acoustic levels

  • Diverse power supply options: external, redundant, hot swappable, AC and DC

  • Wide choice of models offering different port densities: 10, 14, 24GigE, copper and support variety of fiber types: single-mode, multi-mode, short and long haul optics allowing distances of up to 70 km

  • Advanced quality of service (QoS) to support triple-play applications

  • Integrated security features that help mitigate against security threats

  • Wire rate IPv4/v6 layer 2 and 3 switching for future proof investment


ALCATEL
Alcatel-Lucent OmniSwitch 6855 Ethernet Hardened LAN Switch OS6855-24 - ServerBank¸ê°T±ÄÁʺô
OS6855-24
ºô¸ô³]³Æ/ÀW¼eºÞ²z


¡@
²£«~³W®æ
²£«~³W®æ

Simplified manageability and ease of use

Intuitive Alcatel-Lucent command line input (CLI)

Intuitive Alcatel-Lucent command line input (CLI)

Full configuration through SNMP- v1/v2/v3

Full configuration through SNMP- v1/v2/v3

Extensive user manuals with examples

Remote telnet management or secure shell access using SSH

Out-of-bound management through console

Secured file upload using SFTP or SCP

Dual image and dual configuration file storage provides backup

Human readable ASCII based configuration files for offline editing and
bulk configuration

BootP/DHCP client allows auto-config of switch IP information to simplify deployment

Auto-negotiating 10/100/1000 ports automatically configure port speed and duplex setting

Auto MDI/MDIX automatically configures transmit and receive signals to support straight through and crossover cabling

DHCP relay to forward client requests to a DHCP server

Integration with SNMP manager OmniVista for network-wide management

Integration with SNMP manager OmniVista for network-wide management

Network Time Protocol (NTP) client for network wide time synchronization

802.1AB ¡V Link Layer Discovery Protocol (LLDP) with MED extensions

802.1AB ¡V Link Layer Discovery Protocol (LLDP) with MED extensions

Auto QoS for switch management traffic as well as traffic from Alcatel-Lucent IP phones

Troubleshooting

Port-based mirroring

Remote-port mirroring

Policy-based mirroring - Allows selection of the type of traffic to mirror by using QoS policies

Port monitoring feature that allows capture of Ethernet packets to a file, or for on-screen display to assist in troubleshooting

sFlow v5 support to monitor and effectively control and manage the network usage

Local (on the flash) and remote logging (Syslog)

IP tools: ping and trace

802.1ag Ethernet OAM (L2 ping and trace)

High availability

Ring Rapid Spanning Tree optimized for ring topology to provide less than 100ms convergence time

802.1w Rapid Recovery Spanning Tree allows sub-second failover to redundant link

Alcatel-Lucent per-VLAN spanning tree (1x1)

802.1D spanning tree for loop free topology and link redundancy

802.1s multiple spanning tree

Fast forwarding mode on user ports to bypass 30-second delay for spanning tree

Static and 802.3ad dynamic link aggregation that supports automatic configuration of link aggregates with other switches

Broadcast storm control

BPDU blocking ¡V automatically shuts down switch ports being used as user ports if a spanning tree BPDU packet is seen

Unidirectional Link Detection Protocol (UDLD) for detecting one way connections

Graceful Protocol Restart ¡V OSFP

VRRP

Redundant 1:1 power provided by the OmniSwitch 6855 backup power supplies

Quality of Service

Priority queues: eight hardware-based queues per port

Traffic prioritization: Flow-based QoS with internal and external (a.k.a., remarking) prioritization

Bandwidth management: flow based bandwidth management, ingress policing/egress shaping and port based egress shaping

Queue management: Random Early Detect/Discard (RED), configurable
de-queuing algorithm; strict priority, weighted and deficit round robin.

Advanced security

MAC limiting ¡V learned port security

Allowed MAC addresses

802.1X multi-client, multi-VLAN support for per client authentication and VLAN assignment

IEEE 802.1X with group mobility

IEEE 802.1X with MAC based authentication, group mobility or ¡§guest¡¨
VLAN support

802.1x with VoIP VLAN support

MAC-based authentication for non-802.1X host

Authenticated VLAN

Captive portal ¡V an embedded web portal for user authentication .*

Automatic quarantine

PKI authentication for SSH access

Support for host integrity check and remediation VLAN

Support for Alcatel-Lucent OmniVista 2770 Quarantine Manager and quarantine VLAN

Traffic Anomaly Detection (TAD) ¡V embedded

RADIUS and LDAP admin authentication

TACACS+ client allows for authentication authorization and accounting with a remote TACACS+ server

Secure Shell (SSH), Secure Socket Layer (SSL) for HTTPS access and SNMPv3
for encrypted remote management communication

Access control lists (ALC) to filter out unwanted traffic including denial of service attacks

Flow based filtering in hardware (L1-L4); port based, VLAN based ACLs

ACL editing

Support of Microsoft Network Access Protection

Switch protocol security


¡@

¬

MD5 for RIPv2, OSPFv2 and SNMPv3


¡@

¬

SSH for secure CLI session with PKI support


¡@

¬

SSL for secure HTTP session

Metro Ethernet Services

QinQ (VLAN stacking) - 802.1ad ¡V provider bridge

VLAN translation

Ethernet OAM compliant with 802.1ag version 7.0

Ethernet OAM compliant with 802.3ah*

DHCP Snooping, DHCP IP Spoof protection

DHCP Option 82 ¡V relay agent information

MEF 9 and 14 certified

L3 routing protocols (IPv4 and IPv6)

¡@

IP routing


¡@

¬

Static routing


¡@

¬

RIP v1 and v2, RIPng


¡@

¬

OSPF v2, v3


¡@

¬

GRE tunnels


¡@

¬

IP/IP tunnels

Multicast

IGMP v1/v2/v3

IGMP snooping, MLD snooping

PIM-SM, PIM-DM

DVMRP

Network protocol

TCP/IP stack

ARP

DHCP relay

Generic UDP relay per VLAN


¡@

Layer-3 routing (IPX): IP routing, static routing, RIP/SAP

Indicators

Per port LEDs: link / activity /PoE

System LEDs: OK (switch HW/SW status)

PS1/PS2: primary and/or redundant power
supply status

Compliance and Certification Commercial


¡@

EMI/EMC

FCC CRF Title 47 Subpart B (Class A and Class B* limits)

VCCI (Class A and Class B* limits

AS/NZS 3548 (Class A and Class B*)

CE marking for European countries (Class A and Class B*)

EN 55022: 2006 (Emission Standard)

EN 61000-3-3: 1995

EN 61000-3-2: 2006

EN 55024: 1998 (Immunity Standards)


¡@

¬

EN 61000-4-2: 1995+A1: 1998


¡@

¬

EN 61000-4-3: 1996+A1: 1998


¡@

¬

EN 61000-4-4: 1995


¡@

¬

EN 61000-4-5: 1995


¡@

¬

EN 61000-4-6: 1996


¡@

¬

EN 61000-4-8: 1994


¡@

¬

EN 61000-4-11: 1994

IEEE802.3: Hi-Pot Test (2250 VDC on all
Ethernet ports)

Industrial

IEC 60870-2-2 (operational temperature)

IEC 60068-2-1 (temperature type test ¡V cold)

IEC 60068-2-2 (temperature type test ¡V hot)

IEC 60721-3-1: Class 1K5 (storage temperature)

IEC 68-2-30 95% non-condensing humidity

IEC 60255-21-2 (mechanical shock)

IEC 60255-21-1 (vibration)


¡@

EMI/EMC

EN 61131-2

EN 55024: 1998 (Immunity Standards)


¡@

¬

IEC 61000-4-3


¡@

¬

IEC 61000-4-12


¡@

¬

IEC 61000-4-16


¡@

¬

IEC 61000-4-17


¡@

¬

IEC 61000-4-29

IEC 60255-5

IEC 61850-3 (Electric power Substations)

IEEE 1613 (C37.90.x)


¡@

¬

C37.90.3 (ESD)


¡@

¬

C37.90.2 (Radiated RFI)


¡@

¬

IEEE1613 C37.90.1 (Fast Transient)


¡@

¬

IEEE1613 C37.90.1 ( Oscillatory)


¡@

¬

IEEE1613 C37.90 (H.V. Impulse)


¡@

¬

IEEE1613 C37.90 (Dielectric Strength)

NEBs **

GR-63-CORE (temp, humidity, altitude, contamination)

GR-1089-CORE Issue 4 (section 2-3)

GR-1089-CORE Issue 4 (section 3.2, 4-10)

Military

MIL-STD-810F (shock and vibration)

MIL-STD-901D (shock) **

MIL-STD-167-1 (vibration)**

MIL-STD-810F, Methods 500, 501, 502, 503, 504, 505, 506, 507, 508, 509, 510, 512, 514, 515, 516, 520, 521 **

MIL-STD-461E: CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE 102, RS101, RS103 **

Safety Agency Certifications

US UL 60950

IEC 60950-1:2001; all national deviations

EN 60950-1: 2001; all deviations

CAN/CSA-C22.2 No. 60950-1-03

NOM-019 SCFI, Mexico

AS/NZ TS-001 and 60950:2000, Australia

UL-AR, Argentina

UL-GS Mark, Germany

EN 60825-1 Laser, EN60825-2 Laser

CDRH Laser

Safety Agency Certifications

US UL 60950

IEC 60950-1:2001; all national deviations

EN 60950-1: 2001; all deviations

CAN/CSA-C22.2 No. 60950-1-03

NOM-019 SCFI, Mexico

AS/NZ TS-001 and 60950:2000, Australia

UL-AR, Argentina

UL-GS Mark, Germany

EN 60825-1 Laser, EN60825-2 Laser

CDRH Laser

IEEE


¡@

Standards

IEEE 802.1D (STP)

IEEE 802.1p (CoS)

IEEE 802.1Q (VLANs)

IEEE 802.1ad (Provider Bridge) QinQ(VLAN stacking)

IEEE 802.1ag (Connectivity Fault Management)

IEEE 802.1s (MSTP)

IEEE 802.1w (RSTP)

IEEE 802.1X (Port Based Network Access Protocol)

IEEE 802.3i (10BaseT)

IEEE 802.3u (Fast Ethernet)

IEEE 802.3x (Flow Control)

IEEE 802.3z (Gigabit Ethernet)

IEEE 802.3ab (1000BaseT)

IEEE 802.3ac (VLAN Tagging)

IEEE 802.3ad (Link Aggregation)

IEEE 802.3af (Power-over-Ethernet)

IETF Standards


¡@

IPv4

RFC 2003 IP/IP tunneling

RFC 2784 GRE tunneling

PoE models

OS6855-14

  • 12 10/100/1000 RJ-45 ports includinfour PoE capable ports

  • Two SFP fiber ports 100/1000Base-X

  • Operating temperature:

  • -40¢XC to +70¢XC

OS6855-24

  • 20 10/100/1000 RJ-45 copper portsFour of which support PoE

  • Four combo port

  • Operating temperature:

  • -40¢XC to +75¢XC

Fiber models

OS6855-U10

  • Eight SFP fiber ports 100/1000Base-X

  • Two RJ-45 10/100/1000 ports

  • Operating temperature:

  • -40¢XC to +70¢XC

OS6855-U24

  • 22 SFP fiber ports 100/1000Base-X

  • Two combo ports

  • Operating temperature:

  • -40¢XC to +75¢XC

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºALCATEL - OS6855-24 - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºALCATEL - Alcatel-Lucent OmniSwitch 6855 Ethernet Hardened LAN Switch OS6855-24±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 ServerBank¼ö½æ¾÷ºØ
 ÀW¼e­t¸ü¥­¿Å
 2 WAN
 3 WAN
 4 WAN
 8 WAN¤Î¥H¤W
 ¾÷½c«¬¥æ´«¾¹
 ¥æ´«¾¹¼Ò²Õ
 µL½u¸ô¥Ñ¾¹
 ¤u·~¯ÅPOE¥æ´«¾¹
 ¤u·~¯Å¥æ´«¾¹
 ¤u·~¯Å¤á¥~«¬L2
 µL½u°T¸¹ÂX¥R¾¹
 ¤u·~¯ÅºôºÞ¥æ´«¾¹L2
 ¥ø·~¥æ´«¾¹
 ºÞ²z¾÷«¬
 ¤A¤Óºô¸ô¹q·½¨ÑÀ³¾¹
 ºô¸ô¥æ´«¾¹
 ¤u·~¯Å«DºôºÞ¥æ´«¾¹
 4G LTE¹h¹D¾¹
 L2 Switch
 µL½uºô¸ô±±¨î¾¹
 µL½u¼öÂI»{ÃÒ¹h¹D¾¹
 ±µ¤J¼h¥æ´«¾¹
 Wi-Fi AP
 ºôºÞ¥æ´«¾¹
 ÀW¼eºÞ²zQoS
 ¤@¯ë®à¤W«¬¥æ´«¾¹L2
 ºôºÞ¥æ´«¾¹L2
 ¤@¯ë¥æ´«¾¹L2
 L3 Switch
 L4 Switch
 PoE Switch
 ¼eÀWIP¤À¨É¾¹
 ¹q«H¯Å¸ô¥Ñ¾¹Router
 ¥ø·~¥Î¸ô¥Ñ¾¹Router
 ¦C¦L¦øªA¾¹
 §ë¼v¾÷¦øªA¾¹
 ºô¸ô¥d
 µL½uºô¸ôWLAN
 ¶°½u¾¹Hub
 µL½u°ò¦a¥x
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > ºô¸ô³]³Æ/ÀW¼eºÞ²z


ALCATELOS6855-24

Alcatel-Lucent OmniSwitch 6855 Ethernet Hardened LAN Switch OS6855-24


¼tµP¡GALCATEL      >>ÂsÄýALCATEL¥þ³¡²£«~
«¬¸¹¡GOS6855-24



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºALCATEL - OS6855-24 - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºALCATEL - Alcatel-Lucent OmniSwitch 6855 Ethernet Hardened LAN Switch OS6855-24±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Úºô¸ô³]³Æ/ÀW¼eºÞ²z Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óALCATEL¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§ALCATEL²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§ALCATEL­ì¼t°t¥ó


¡@

¡@

¡@

²£«~¯S¦â
  • Purpose built, industrial strength, engineered to operate in temperatures ranging from -40C up to + 75C

  • Convection cooling fan-less design that offers increased reliability and lower acoustic levels

  • Diverse power supply options: external, redundant, hot swappable, AC and DC

  • Wide choice of models offering different port densities: 10, 14, 24GigE, copper and support variety of fiber types: single-mode, multi-mode, short and long haul optics allowing distances of up to 70 km

  • Advanced quality of service (QoS) to support triple-play applications

  • Integrated security features that help mitigate against security threats

  • Wire rate IPv4/v6 layer 2 and 3 switching for future proof investment


ALCATEL
Alcatel-Lucent OmniSwitch 6855 Ethernet Hardened LAN Switch OS6855-24 - ServerBank¸ê°T±ÄÁʺô
OS6855-24
ºô¸ô³]³Æ/ÀW¼eºÞ²z


¡@
²£«~³W®æ
²£«~³W®æ

Simplified manageability and ease of use

Intuitive Alcatel-Lucent command line input (CLI)

Intuitive Alcatel-Lucent command line input (CLI)

Full configuration through SNMP- v1/v2/v3

Full configuration through SNMP- v1/v2/v3

Extensive user manuals with examples

Remote telnet management or secure shell access using SSH

Out-of-bound management through console

Secured file upload using SFTP or SCP

Dual image and dual configuration file storage provides backup

Human readable ASCII based configuration files for offline editing and
bulk configuration

BootP/DHCP client allows auto-config of switch IP information to simplify deployment

Auto-negotiating 10/100/1000 ports automatically configure port speed and duplex setting

Auto MDI/MDIX automatically configures transmit and receive signals to support straight through and crossover cabling

DHCP relay to forward client requests to a DHCP server

Integration with SNMP manager OmniVista for network-wide management

Integration with SNMP manager OmniVista for network-wide management

Network Time Protocol (NTP) client for network wide time synchronization

802.1AB ¡V Link Layer Discovery Protocol (LLDP) with MED extensions

802.1AB ¡V Link Layer Discovery Protocol (LLDP) with MED extensions

Auto QoS for switch management traffic as well as traffic from Alcatel-Lucent IP phones

Troubleshooting

Port-based mirroring

Remote-port mirroring

Policy-based mirroring - Allows selection of the type of traffic to mirror by using QoS policies

Port monitoring feature that allows capture of Ethernet packets to a file, or for on-screen display to assist in troubleshooting

sFlow v5 support to monitor and effectively control and manage the network usage

Local (on the flash) and remote logging (Syslog)

IP tools: ping and trace

802.1ag Ethernet OAM (L2 ping and trace)

High availability

Ring Rapid Spanning Tree optimized for ring topology to provide less than 100ms convergence time

802.1w Rapid Recovery Spanning Tree allows sub-second failover to redundant link

Alcatel-Lucent per-VLAN spanning tree (1x1)

802.1D spanning tree for loop free topology and link redundancy

802.1s multiple spanning tree

Fast forwarding mode on user ports to bypass 30-second delay for spanning tree

Static and 802.3ad dynamic link aggregation that supports automatic configuration of link aggregates with other switches

Broadcast storm control

BPDU blocking ¡V automatically shuts down switch ports being used as user ports if a spanning tree BPDU packet is seen

Unidirectional Link Detection Protocol (UDLD) for detecting one way connections

Graceful Protocol Restart ¡V OSFP

VRRP

Redundant 1:1 power provided by the OmniSwitch 6855 backup power supplies

Quality of Service

Priority queues: eight hardware-based queues per port

Traffic prioritization: Flow-based QoS with internal and external (a.k.a., remarking) prioritization

Bandwidth management: flow based bandwidth management, ingress policing/egress shaping and port based egress shaping

Queue management: Random Early Detect/Discard (RED), configurable
de-queuing algorithm; strict priority, weighted and deficit round robin.

Advanced security

MAC limiting ¡V learned port security

Allowed MAC addresses

802.1X multi-client, multi-VLAN support for per client authentication and VLAN assignment

IEEE 802.1X with group mobility

IEEE 802.1X with MAC based authentication, group mobility or ¡§guest¡¨
VLAN support

802.1x with VoIP VLAN support

MAC-based authentication for non-802.1X host

Authenticated VLAN

Captive portal ¡V an embedded web portal for user authentication .*

Automatic quarantine

PKI authentication for SSH access

Support for host integrity check and remediation VLAN

Support for Alcatel-Lucent OmniVista 2770 Quarantine Manager and quarantine VLAN

Traffic Anomaly Detection (TAD) ¡V embedded

RADIUS and LDAP admin authentication

TACACS+ client allows for authentication authorization and accounting with a remote TACACS+ server

Secure Shell (SSH), Secure Socket Layer (SSL) for HTTPS access and SNMPv3
for encrypted remote management communication

Access control lists (ALC) to filter out unwanted traffic including denial of service attacks

Flow based filtering in hardware (L1-L4); port based, VLAN based ACLs

ACL editing

Support of Microsoft Network Access Protection

Switch protocol security


¡@

¬

MD5 for RIPv2, OSPFv2 and SNMPv3


¡@

¬

SSH for secure CLI session with PKI support


¡@

¬

SSL for secure HTTP session

Metro Ethernet Services

QinQ (VLAN stacking) - 802.1ad ¡V provider bridge

VLAN translation

Ethernet OAM compliant with 802.1ag version 7.0

Ethernet OAM compliant with 802.3ah*

DHCP Snooping, DHCP IP Spoof protection

DHCP Option 82 ¡V relay agent information

MEF 9 and 14 certified

L3 routing protocols (IPv4 and IPv6)

¡@

IP routing


¡@

¬

Static routing


¡@

¬

RIP v1 and v2, RIPng


¡@

¬

OSPF v2, v3


¡@

¬

GRE tunnels


¡@

¬

IP/IP tunnels

Multicast

IGMP v1/v2/v3

IGMP snooping, MLD snooping

PIM-SM, PIM-DM

DVMRP

Network protocol

TCP/IP stack

ARP

DHCP relay

Generic UDP relay per VLAN


¡@

Layer-3 routing (IPX): IP routing, static routing, RIP/SAP

Indicators

Per port LEDs: link / activity /PoE

System LEDs: OK (switch HW/SW status)

PS1/PS2: primary and/or redundant power
supply status

Compliance and Certification Commercial


¡@

EMI/EMC

FCC CRF Title 47 Subpart B (Class A and Class B* limits)

VCCI (Class A and Class B* limits

AS/NZS 3548 (Class A and Class B*)

CE marking for European countries (Class A and Class B*)

EN 55022: 2006 (Emission Standard)

EN 61000-3-3: 1995

EN 61000-3-2: 2006

EN 55024: 1998 (Immunity Standards)


¡@

¬

EN 61000-4-2: 1995+A1: 1998


¡@

¬

EN 61000-4-3: 1996+A1: 1998


¡@

¬

EN 61000-4-4: 1995


¡@

¬

EN 61000-4-5: 1995


¡@

¬

EN 61000-4-6: 1996


¡@

¬

EN 61000-4-8: 1994


¡@

¬

EN 61000-4-11: 1994

IEEE802.3: Hi-Pot Test (2250 VDC on all
Ethernet ports)

Industrial

IEC 60870-2-2 (operational temperature)

IEC 60068-2-1 (temperature type test ¡V cold)

IEC 60068-2-2 (temperature type test ¡V hot)

IEC 60721-3-1: Class 1K5 (storage temperature)

IEC 68-2-30 95% non-condensing humidity

IEC 60255-21-2 (mechanical shock)

IEC 60255-21-1 (vibration)


¡@

EMI/EMC

EN 61131-2

EN 55024: 1998 (Immunity Standards)


¡@

¬

IEC 61000-4-3


¡@

¬

IEC 61000-4-12


¡@

¬

IEC 61000-4-16


¡@

¬

IEC 61000-4-17


¡@

¬

IEC 61000-4-29

IEC 60255-5

IEC 61850-3 (Electric power Substations)

IEEE 1613 (C37.90.x)


¡@

¬

C37.90.3 (ESD)


¡@

¬

C37.90.2 (Radiated RFI)


¡@

¬

IEEE1613 C37.90.1 (Fast Transient)


¡@

¬

IEEE1613 C37.90.1 ( Oscillatory)


¡@

¬

IEEE1613 C37.90 (H.V. Impulse)


¡@

¬

IEEE1613 C37.90 (Dielectric Strength)

NEBs **

GR-63-CORE (temp, humidity, altitude, contamination)

GR-1089-CORE Issue 4 (section 2-3)

GR-1089-CORE Issue 4 (section 3.2, 4-10)

Military

MIL-STD-810F (shock and vibration)

MIL-STD-901D (shock) **

MIL-STD-167-1 (vibration)**

MIL-STD-810F, Methods 500, 501, 502, 503, 504, 505, 506, 507, 508, 509, 510, 512, 514, 515, 516, 520, 521 **

MIL-STD-461E: CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE 102, RS101, RS103 **

Safety Agency Certifications

US UL 60950

IEC 60950-1:2001; all national deviations

EN 60950-1: 2001; all deviations

CAN/CSA-C22.2 No. 60950-1-03

NOM-019 SCFI, Mexico

AS/NZ TS-001 and 60950:2000, Australia

UL-AR, Argentina

UL-GS Mark, Germany

EN 60825-1 Laser, EN60825-2 Laser

CDRH Laser

Safety Agency Certifications

US UL 60950

IEC 60950-1:2001; all national deviations

EN 60950-1: 2001; all deviations

CAN/CSA-C22.2 No. 60950-1-03

NOM-019 SCFI, Mexico

AS/NZ TS-001 and 60950:2000, Australia

UL-AR, Argentina

UL-GS Mark, Germany

EN 60825-1 Laser, EN60825-2 Laser

CDRH Laser

IEEE


¡@

Standards

IEEE 802.1D (STP)

IEEE 802.1p (CoS)

IEEE 802.1Q (VLANs)

IEEE 802.1ad (Provider Bridge) QinQ(VLAN stacking)

IEEE 802.1ag (Connectivity Fault Management)

IEEE 802.1s (MSTP)

IEEE 802.1w (RSTP)

IEEE 802.1X (Port Based Network Access Protocol)

IEEE 802.3i (10BaseT)

IEEE 802.3u (Fast Ethernet)

IEEE 802.3x (Flow Control)

IEEE 802.3z (Gigabit Ethernet)

IEEE 802.3ab (1000BaseT)

IEEE 802.3ac (VLAN Tagging)

IEEE 802.3ad (Link Aggregation)

IEEE 802.3af (Power-over-Ethernet)

IETF Standards


¡@

IPv4

RFC 2003 IP/IP tunneling

RFC 2784 GRE tunneling

PoE models

OS6855-14

  • 12 10/100/1000 RJ-45 ports includinfour PoE capable ports

  • Two SFP fiber ports 100/1000Base-X

  • Operating temperature:

  • -40¢XC to +70¢XC

OS6855-24

  • 20 10/100/1000 RJ-45 copper portsFour of which support PoE

  • Four combo port

  • Operating temperature:

  • -40¢XC to +75¢XC

Fiber models

OS6855-U10

  • Eight SFP fiber ports 100/1000Base-X

  • Two RJ-45 10/100/1000 ports

  • Operating temperature:

  • -40¢XC to +70¢XC

OS6855-U24

  • 22 SFP fiber ports 100/1000Base-X

  • Two combo ports

  • Operating temperature:

  • -40¢XC to +75¢XC

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºALCATEL - OS6855-24 - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºALCATEL - Alcatel-Lucent OmniSwitch 6855 Ethernet Hardened LAN Switch OS6855-24±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@