PS6110S
PS6110S
¡@
¡@
Product Configurations
Storage Controllers
Dual controllers, each with 4GB1 memory
for PS Series firmware. Each controller provides cache to flash for data
protection.
Hard Disk Drives
Twenty-four (24) SSD hot-pluggable hard disk drives (Twelve (12) drive
configuration available. Please contact your Dell Sales Representative for
details.)
Drive Capacities
2.5" SSD drives available in 200GB1 and
400GB1
System Capacities
4.8TB1 using
twenty-four (24) 200 GB1 SSD
drives
9.6TB1 using
twenty-four (24) 400 GB1 SSD
drives
Technical Highlights
Volumes
Up to 1,024
Snapshots
512 per volume / up to 10,000 total per group
Volume connections per PS series group
Up to 1,024
Host Protocol
Any standards-compliant iSCSI initiator
Operating Systems Supported
¡@
Windows® 2000 Server
Windows Server® 2003
Windowa Vista®
Windows XP®
Windows Server® 2008,
including Hyper-V™
Windows Server® 2008
R2, including Hyper-V™
VMware® ESX Server 3 /
3.5 / 4 / 4.1 / 5, ESXi 3.5 / 4 / 4.1 / 5
Citrix® XenServer™
Red Hat® Enterprise
Linux®
SUSE® Linux Enterprise
SunTM Solaris™
IBM® AIX
HP-UX®
Mac OS® X
Novell® Netware®
RAID Support
RAID 5, RAID 6, RAID 10, and RAID 50
Network Interfaces
¡@
10GbE connectivity with one (1) 10GBASE-T with RJ45, one (1)
10GbE SFP+ for fibre or twin-ax copper cabling, and one (1)
100BASE-TX dedicated management port per controller
TCP Network Support
IPv4, IPv6 core support
Expansion Option
Can be combined with other EqualLogic PS Series arrays in the same SAN group,
online. Up to 16 total members per group.
Reliability
Vertical port sharing
Redundant, hot-swappable controllers, power supplies / cooling fans, and
hot-swappable disks
Individual disk drive slot power control
Enclosure Monitoring System
¡@Automatic spare configuration and utilization
SMART
Automatic bad block replacement
Auto-Stat Disk Monitoring System (ADMS) to monitor health of data on disk
drives
Management Interfaces
SAN HeadQuarters (SANHQ)
multi-group performance and event monitoring tool
SNMP, telnet, SSH, HTTP, Web (SSL), host scripting
Serial console
Multi-administrator support
Ability to configure a separate management network
Security
CHAP authentication
Access control for iSCSI
Access control for management interfaces including Active Directory, LDAP or
RADIUS support
Notification Methods
SNMP traps, e-mail, syslog
Power
AC voltage: 100-240 VAC +10% single phase
700W (max, total), +5V up to 155W; +12V up to 924W; +5Vsb up to 10W
Frequency: 50/60 Hz
Power factor: 0.98 (minimum)
Power supplies: Dual 700W
Environmental
Temperature range: 5¢X to 40¢XC (41¢X to 104¢XF)
Storage temperature: -40¢X to 65¢XC (-40¢X to 149¢XF)
Altitude: For altitudes above 2950 feet, the maximum operating temperature is
derated 1¢XF/550 ft
Operating Relative humidity: 20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
Operational shock: Half-sine shock 31G +/- 5% with a pulse duration of 2.6ms
+/- 10% in operational orientations only
Operating Vibration: 0.26 Grms (5 to 350 Hz) for 5 minutes in operational
orientations
Acoustics Category 4: <=7.2 bels at 23C +/- 2C
Airborne contaminant level of G1 or lower as defined by ISA-S71.04-1985
Physical
Height: 2U/8.68 cm (3.41 inches)
Width: 44.63 cm (17.57 inches)
Depth: 54.1 cm (21.3 inches)
Weight: 25.4 kg (56 lb)
¡@