­º­¶> Àx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦CRAID>Fibre-to-SCSI

>>ÂsÄý©Ò¦³Infortrend´¶¦wÀx¦s³]³Æ/³Æ¥÷¤è®×>

Infortrend´¶¦w
ESVA F75-2830L

«¬¸¹¡GESVA F75-2830L


Infortrend´¶¦wESVA F75-2830L


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºInfortrend´¶¦w - ESVA F75-2830L - Àx¦s³]³Æ/³Æ¥÷¤è®×>
³Ì¦nªºInfortrend´¶¦w - ESVA F75-2830L±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦CRAID>Fibre-to-SCSI Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óInfortrend´¶¦w¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§Infortrend´¶¦w²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§Infortrend´¶¦w­ì¼t°t¥ó


¡@

¡@

¡@


Infortrend´¶¦w
ESVA F75-2830L - ServerBank¸ê°T±ÄÁʺô
ESVA F75-2830L
Àx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦CRAID>Fibre-to-SCSI


¡@
²£«~³W®æ
·s¼Wºô­¶1

Host Ports

Eight 8Gb/s Fibre Channel ports (4 per controller)
Four 1Gb/s iSCSI ports* (2 per controller)

* Optional 

Storage Controller

Dual redundant controllers

Cache Memory

16GB or 32GB

Drive Connectivity

¡P         6Gb/s SAS connectivity

¡P         Accommodates 3.5-inch disk drives

¡P         S.M.A.R.T. support

¡P         Automatic bad-sector reassignment

¡P         Dedicated bandwidth to each connected drive

Supported Drives

¡P         2.5" SAS 6G MLC SSD - 200GB, 400GB or 800GB

¡P         2.5" 10,000 RPM SAS drives - 300GB, 450GB, 600GB, 900GB or 1.2TB

¡P         3.5" 15,000 RPM SAS drives - 300GB, 450GB or 600GB

¡P         3.5" 7,200 RPM Nearline SAS drives - 2TB, 3TB or 4TB

Maximum Number of Drives

¡P         Per system: 16

¡P         Via JBOD: 400

¡P         Via scale-out*: 800

*Optional

Corresponding Expansion Enclosure

Please refer to Related Information

Form Factor

3U

RAID Functionality

¡P         Global, delicated or enclosure hot-spare

¡P         RAID levels supported : RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60

¡P         Online expansion by:

¡P         Adding new drives

¡P         Copying and replacing drives with drives of larger capacity

¡P         RAID migration

¡P         Configurable stripe size and write policy per system

¡P         Intelligent drive handling

¡P         In degraded mode: skips irreparable blocks to continue rebuild

¡P         In normal operation: data-block verification and repair

Data Services

¡P         Enterprise Scalable Virtualized Architecture
- Linear scaling of performance and capacity (Scale-out)*
- Storage pooling
- Thin-provisioning
- Automatic data migration
- Prioritized volume accessibility
- Distributed load balancing
- Automated storage tiering

¡P         Data Protection
Local replication
- Snapshot
- Volume copy/ volume mirror
- Quick recovery
Remote replication*
- Synchronous and asynchronous
- Data compression
- Near continuous data protection (N-CDP)

* Optional

Green Design

¡P         80 PLUS-certified power supplies delivering more than 80% energy efficiency

¡P         Intelligent multi-level drive spin-down

Availability and Reliability

¡P         Redundant, hot-swappable hardware modules

¡P         CacheSafe technology

¡P         Multi-pathing support (EonPath)

¡P         Online, non-disruptive firmware upgrades

¡P         Device mapper support

Notification

Various event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and Skype. 

Management

¡P         Java-based SANWatch management software

¡P         RS232 serial port for local access to firmware-embedded utility

¡P         Automated cache flush and caching mode operation per enclosure status

¡P         Telnet and SSH system monitoring via Ethernet

¡P         Platform-independent firmware management GUI

¡P         Module status LED indicators: component presence detection & thermal sensors via I2C bus

OS Support

¡P         Windows Server 2003

¡P         Windows Server 2008, 2008 R2 (including Hyper-V)

¡P         Windows Server 2012 (including Hyper-V)

¡P         Windows 7 Enterprise SP1

¡P         RedHat Enterprise Linux

¡P         SUSE Linux Enterprise

¡P         Sun Solaris

¡P         IBM AIX

¡P         HP-UX

¡P         Debian

¡P         CentOS

¡P         VMware

¡P         Citrix XenServer

** For the latest OS support details, please contact our sales representatives.

Service and Support

All ESVA systems are shipped with 3-year Standard Service

¡P         Standard Service:

¡P         Hardware warranty; replacement part dispatch on the next business day

¡P         Software update; 24x7 phone, web and email support

¡P         Advanced Service*: Standard service + Onsite diagnostics on the next business day

¡P         Premium Service*: Standard service + Onsite diagnostics in 4 hours

* Optional
** Service may vary by region

Power

¡P         Power supplies: Two 530W DC

¡P         AC voltage: 100VAC @ 10A to 240VAC @ 5A with PFC (auto-switching)

¡P         Frequency: 47-63 Hz

Environmental

¡P         Temperature:

¡P         Operating: 0 to 40¢XC without BBU or CBM / 0 to 35¢XC with BBU or CBM

¡P         Non-operating: -40 to 60¢X

¡P         Altitude: Sea level to 3660m (12,000ft) operating / sea level to 12,192m (40,000ft) non-operating

¡P         Relative humidity: 5 to 95% non-condensing, operating and non-operating

Dimensions

445mm (W) x 130mm (H) x 514mm (D)
**Without chassis ears / protrusions

Weight

19.66kg/ 43.69lbs (without HDDs)

Package Dimensions

776mm (W) x 533mm (H) x 573mm (D)

 


¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºInfortrend´¶¦w - ESVA F75-2830L - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºInfortrend´¶¦w - ESVA F75-2830L±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 NASºô¸ôÀx¦sÀɮצøªA¾¹
 ServerBank±ÀÂ˾÷ºØ
 ®à¤W«¬
 ¾÷¬[¦¡
 ª½¥ß¦¡
 ºÏºÐ°}¦C°t¥ó
 ¦Û°Ê¥úºÐ«þ¨©¾÷
 ¥~±µ¦¡µwºÐ
 ºÏ±a¾÷
 SDLT
 DLT
 LTO 1/2/3/4
 Ultrium I
 Ultrium II
 SAIT
 AIT
 AIT Turbo
 DAT
 DDS
 ºÏ±a´«±a¾÷Autoloader
 iSCSI¸Ñ¨M¤è®×
 iSCSIºÏºÐ°}¦C
 iSCSI¾ô±µ¾¹
 ºÏºÐ°}¦CRAID
 ServerBank±ÀÂ˾÷ºØ
 iSCSI
 iSCSI to SAS
 SATA
 SCSI-to-SCSI
 SCSI-to-IDE
 SCSI-to-SATA
 Fibre-to-SCSI
 Fibre-to-IDE
 Fibre-to-SATA
 Fibre-to-Fibre
 Fibre to SAS
 USB-to-IDE
 SATA-to-SATA
 SATA-to-IDE
 SAS
 IDE-to-IDE
 1394-to-IDE
 JBOD
 ºÏºÐ°}¦CÂd
 1394B-to-SATAII
 1394B-to PATA
 °ïÅ|¦¡Àx¦s¥~±µ²°
 SAS-to-SATA
 SAS-to-SAS
 SCSI-to-SAS
 PCIE
 USB
 IDE
 SAN¸Ñ¨M¤è®×
 ¥úÅÖ³q¹D¥æ´«¾¹
 ¥úÅÖ³q¹D¤¶­±¥d
 SAN Storage
 SAN Software
 ¥úÅÖ³q¹D¾ô±µ¾¹
 ¾É¦V¾¹director
 ¥úÅÖ¼Ò²Õ
 Àx¦sºÞ²z³nÅé
 ºÏ±aÂd
 ºÏ±a
 ¦Û°Ê´«¤ù¥úºÐ
 ÂÅ¥ú¥úºÐÂd
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > Àx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦CRAID>Fibre-to-SCSI


Infortrend´¶¦wESVA F75-2830L

ESVA F75-2830L


¼tµP¡GInfortrend´¶¦w      >>ÂsÄýInfortrend´¶¦w¥þ³¡²£«~
«¬¸¹¡GESVA F75-2830L



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºInfortrend´¶¦w - ESVA F75-2830L - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºInfortrend´¶¦w - ESVA F75-2830L±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦CRAID>Fibre-to-SCSI Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óInfortrend´¶¦w¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§Infortrend´¶¦w²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§Infortrend´¶¦w­ì¼t°t¥ó


¡@

¡@

¡@


Infortrend´¶¦w
ESVA F75-2830L - ServerBank¸ê°T±ÄÁʺô
ESVA F75-2830L
Àx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦CRAID>Fibre-to-SCSI


¡@
²£«~³W®æ
·s¼Wºô­¶1

Host Ports

Eight 8Gb/s Fibre Channel ports (4 per controller)
Four 1Gb/s iSCSI ports* (2 per controller)

* Optional 

Storage Controller

Dual redundant controllers

Cache Memory

16GB or 32GB

Drive Connectivity

¡P         6Gb/s SAS connectivity

¡P         Accommodates 3.5-inch disk drives

¡P         S.M.A.R.T. support

¡P         Automatic bad-sector reassignment

¡P         Dedicated bandwidth to each connected drive

Supported Drives

¡P         2.5" SAS 6G MLC SSD - 200GB, 400GB or 800GB

¡P         2.5" 10,000 RPM SAS drives - 300GB, 450GB, 600GB, 900GB or 1.2TB

¡P         3.5" 15,000 RPM SAS drives - 300GB, 450GB or 600GB

¡P         3.5" 7,200 RPM Nearline SAS drives - 2TB, 3TB or 4TB

Maximum Number of Drives

¡P         Per system: 16

¡P         Via JBOD: 400

¡P         Via scale-out*: 800

*Optional

Corresponding Expansion Enclosure

Please refer to Related Information

Form Factor

3U

RAID Functionality

¡P         Global, delicated or enclosure hot-spare

¡P         RAID levels supported : RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60

¡P         Online expansion by:

¡P         Adding new drives

¡P         Copying and replacing drives with drives of larger capacity

¡P         RAID migration

¡P         Configurable stripe size and write policy per system

¡P         Intelligent drive handling

¡P         In degraded mode: skips irreparable blocks to continue rebuild

¡P         In normal operation: data-block verification and repair

Data Services

¡P         Enterprise Scalable Virtualized Architecture
- Linear scaling of performance and capacity (Scale-out)*
- Storage pooling
- Thin-provisioning
- Automatic data migration
- Prioritized volume accessibility
- Distributed load balancing
- Automated storage tiering

¡P         Data Protection
Local replication
- Snapshot
- Volume copy/ volume mirror
- Quick recovery
Remote replication*
- Synchronous and asynchronous
- Data compression
- Near continuous data protection (N-CDP)

* Optional

Green Design

¡P         80 PLUS-certified power supplies delivering more than 80% energy efficiency

¡P         Intelligent multi-level drive spin-down

Availability and Reliability

¡P         Redundant, hot-swappable hardware modules

¡P         CacheSafe technology

¡P         Multi-pathing support (EonPath)

¡P         Online, non-disruptive firmware upgrades

¡P         Device mapper support

Notification

Various event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and Skype. 

Management

¡P         Java-based SANWatch management software

¡P         RS232 serial port for local access to firmware-embedded utility

¡P         Automated cache flush and caching mode operation per enclosure status

¡P         Telnet and SSH system monitoring via Ethernet

¡P         Platform-independent firmware management GUI

¡P         Module status LED indicators: component presence detection & thermal sensors via I2C bus

OS Support

¡P         Windows Server 2003

¡P         Windows Server 2008, 2008 R2 (including Hyper-V)

¡P         Windows Server 2012 (including Hyper-V)

¡P         Windows 7 Enterprise SP1

¡P         RedHat Enterprise Linux

¡P         SUSE Linux Enterprise

¡P         Sun Solaris

¡P         IBM AIX

¡P         HP-UX

¡P         Debian

¡P         CentOS

¡P         VMware

¡P         Citrix XenServer

** For the latest OS support details, please contact our sales representatives.

Service and Support

All ESVA systems are shipped with 3-year Standard Service

¡P         Standard Service:

¡P         Hardware warranty; replacement part dispatch on the next business day

¡P         Software update; 24x7 phone, web and email support

¡P         Advanced Service*: Standard service + Onsite diagnostics on the next business day

¡P         Premium Service*: Standard service + Onsite diagnostics in 4 hours

* Optional
** Service may vary by region

Power

¡P         Power supplies: Two 530W DC

¡P         AC voltage: 100VAC @ 10A to 240VAC @ 5A with PFC (auto-switching)

¡P         Frequency: 47-63 Hz

Environmental

¡P         Temperature:

¡P         Operating: 0 to 40¢XC without BBU or CBM / 0 to 35¢XC with BBU or CBM

¡P         Non-operating: -40 to 60¢X

¡P         Altitude: Sea level to 3660m (12,000ft) operating / sea level to 12,192m (40,000ft) non-operating

¡P         Relative humidity: 5 to 95% non-condensing, operating and non-operating

Dimensions

445mm (W) x 130mm (H) x 514mm (D)
**Without chassis ears / protrusions

Weight

19.66kg/ 43.69lbs (without HDDs)

Package Dimensions

776mm (W) x 533mm (H) x 573mm (D)

 


¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºInfortrend´¶¦w - ESVA F75-2830L - Àx¦s³]³Æ/³Æ¥÷¤è®×> ,³Ì¦nªºInfortrend´¶¦w - ESVA F75-2830L±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@