NetApp All Flash FAS Technical Specifications - ServerBank¸ê°T±ÄÁʺô All Flash FAS Technical Specifications Àx¦s³]³Æ/³Æ¥÷¤è®×
¡@
Scale-out
|
AFF8080 EX |
AFF8060 |
AFF8040 |
AFF8020 |
NAS Scale-out |
1-24 nodes (12 HA Pairs) |
Maximum SSD |
2880 |
2880 |
2880 |
2880 |
Maximum Raw Capacity: All Flash |
4.6PB/4.09PiB |
4.6PB/4.09PiB |
4.6PB/4.09PiB |
4.6PBB/4.09PiB |
Effective Capacity[*] |
17.9PB/16.7PiB |
17.9PB/16.7PiB |
17.9PB/16.7PiB |
17.9PB/16.7PiB |
Maximum Memory |
3,072GB |
1,536GB |
768GB |
576GB |
SAN Scale-out |
1-8 nodes (4 HA Pairs) |
Maximum SSD |
960 |
960 |
960 |
960 |
Maximum Raw Capacity |
1.5PB/1.33PiB |
1.5PB/1.33PiB |
1.5PB/1.33PiB |
1.5PB/1.33PiB |
Effective Capacity[*] |
6.3PB/5.56PiB |
6.3PB/5.56PiB |
6.3PB/5.56PiB |
6.3PB/5.56PiB |
Maximum Memory |
1,024GB |
512GB |
256GB |
192GB |
Cluster Interconnect |
2, 4, or 6 10GbE |
2 or 4 10GbE |
2 or 4 10GbE |
2 10GbE |
[*]Effective capacity based on 5:1 storage efficiency ratios with the
maximum number of SSDs installed. Actual ratio is up to 10:1 and higher
depending on workloads and use cases.
Per HA Pair Specifications (active-active
dual controller)
|
AFF8080 EX |
AFF8060 |
AFF8040 |
AFF8020 |
Maximum SSD |
240 |
240 |
240 |
240 |
Maximum Raw
Capacity: All Flash |
384TB/349TiB |
384TB/349TiB |
384TB/349TiB |
384TB/349TiB |
Effective Capacity[*] |
1565.3TB/1423TiB |
1565.3TB/1423TiB |
1565.3TB/1423TiB |
1565.3TB/1423TiB |
Controller Form Factor |
Dual enclosure HA;
2 controllers in two 6U chassis; total of 12U |
Single enclosure HA;
2 controllers in single 6U chassis |
Single enclosure HA;
2 controllers in single 6U chassis |
Single enclosure HA;
2 controllers in single 3U chassis |
Memory |
256GB |
128GB |
64GB |
48GB |
NVRAM |
32GB |
16GB |
16GB |
8GB |
PCIe Expansion Slots |
24 |
8 |
8 |
4 |
Onboard I/O: UTA2 (10GbE/FCoE,
16Gb FC) |
8 |
8 |
8 |
4 |
Onboard I/O: 10GbE |
8 |
8 |
8 |
4 |
Onboard I/O: GbE |
8 |
8 |
8 |
4 |
Onboard I/O: 6Gb SAS |
8 |
8 |
8 |
4 |
Storage Networking Supported |
FC; FCoE; iSCSI; NFS; pNFS; CIFS/SMB |
OS Version |
Data ONTAP 8.3 or higher |
¡@ |
High-Availability Features |
Alternate Control Path (ACP); Ethernet-based service processor and
Data ONTAP management interface; redundant hot-swappable
controllers, cooling fans, power supplies, and optics |
Supported Configurations |
Cluster Configurations
- Single-node cluster
- Two-node switchless or switched
cluster
- Nodes within a cluster
MetroCluster Configurations
- Active-active controller with
stretch (non-switch) MetroCluster
- Active-active controller with
fabric-attached (switched) MetroCluster
|
Disk Shelves Supported |
DS2246 (2U; 24 drives, 2.5" SFF)
See NetApp Disk Shelves and Storage Media for more details on each
disk shelf and supported drive types. |
Maximum RAID Group Sizes |
RAID 6 (RAID-DP)
SSD: 28 (26 data disks plus 2 parity disks)
RAID 4
SSD: 14 (13 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror) |
Host Operating Systems Supported |
Windows® 2000, Windows Server 2003, Windows Server 2008, Windows
Server 2012, Windows XP, Linux®, Oracle® Solaris, AIX, HP-UX, Mac®
OS, VMware®, ESX |
Max. Number of LUNs |
12,000 per node |
Number of Supported SAN Hosts |
Up to 512 hosts per HA pair
Up to 24 directly connected servers per HA pair |
FlexVol® Volumes |
Up to 1,000 per controller |
Snapshot® Copies |
Up to 127,000 |
Maximum Volume/ Aggregate Size |
100TB |
100TB |
100TB |
70TB |
Maximum port count includes integrated ports and PCIe expansion
slots per HA pair
¡@ |
FC Target Ports (16Gb
autoranging) |
64 |
24 |
24 |
12 |
FC Target Ports (4Gb or 8Gb) |
64 |
40 |
40 |
20 |
FCoE Target Ports, UTA (max.) |
32 |
24 |
24 |
12 |
10GbE Ports (max.) |
64 |
32 |
32 |
16 |
GbE Ports (max.) |
72 |
40 |
40 |
20 |
6Gb SAS Ports (max.) |
56 |
40 |
40 |
20 |
FC Initiator Ports (max.) |
72 |
40 |
40 |
20 |
Maximum Adapters |
Dual 10GbE (optical or copper) |
16 |
8 |
8 |
4 |
Dual 10Gbase-T (RJ-45,CAT 6A-E) |
16 |
8 |
8 |
4 |
Quad GbE (copper) |
16 |
8 |
8 |
4 |
Dual 10GbE/FCoE 16Gb FC Unified
Target Adapter 2 (UTA2, optical or copper for 10GbE/FCoE
deployments, optical for 16Gb FC) |
24 |
8 |
8 |
4 |
8Gb FC Target |
16 |
8 |
8 |
4 |
Quad 6Gb SAS Storage HBA |
12 |
8 |
8 |
4 |
Quad 4Gb FC Storage/Tape HBA
(fiber) |
16 |
8 |
8 |
4 |
[*]Effective capacity based on 5:1 storage efficiency ratios with the
maximum number of SSDs installed. Actual ratio is up to 10:1 and higher
depending on workloads and use cases.
System Environmental Specifications
|
AFF8080 EX |
AFF8060 |
AFF8040 |
AFF8020 |
Thermal Rating
(at 200V) |
2,880 BTU (typical, per enclosure)
3,252 BTU (worst case, per enclosure) |
2,031 BTU (typical)
2,362 BTU (worst case) |
1,495 BTU (typical)
1,843 BTU (worst case) |
1,205 BTU (typical)
1,450 BTU (worst case) |
Weight |
119.8 lb |
121 lb |
121 lb |
78 lb |
Height |
12U (6U per enclosure) |
6U |
6U |
3U |
Width |
19" IEC rack-compliant (17.6", 44.7 cm) |
Depth |
24.3" (28.9" with cable management) |
Operating Temperature, Altitude,
and Relative Humidity |
10¢X C to 40¢X C (50¢X F to 104¢X F); at <= 3,000 m (at <= 10,000 feet)
elevation; 20% to 80% relative humidity, noncondensing (28¢X C wet
bulb temperature) |
Nonoperating Temperature and
Relative Humidity |
-40¢X C to 65¢X C (-40¢X F to 149¢X F); 5% to 95% relative humidity,
noncondensing, in original container |
Operating Acoustic Noise |
AFF8020:
- Declared sound power (LwAd) per
ISO 9296: 7.8 Bel
- Sound pressure (LpAm) (bystander
positions): 62.6 dB
AFF8040/AFF8060:
- Declared sound power (LwAd) per
ISO 9296: 7.6 Bel
- Sound pressure (LpAm) (bystander
positions): 62.9 dB
AFF8080 EX:
- Declared sound power (LwAd) per
ISO 9296: 7.5 Bel @ normal operating conditions (at 23 ¢XC and at
sea level)
|
Compliance |
RoHS-compliant (PDF)
¡@ |
Safety/Emissions/Immunity |
Safety: EN
60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national
deviations), EN60825-1, IRAM, GOST-R, BSMI, SONCAP, NRCS LOA (South
Africa)
Emissions/Immunity: FCC
Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022,
EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI |
NetApp Systems Cabinet
|
AFF8080 EX |
AFF8060 |
AFF8040 |
AFF8020 |
Rack Space |
42U |
Dimensions
(height/width/depth) |
78.75" (200 cm)/23.6" (60 cm)/44.3" (112.5 cm) |
Minimum Cabinet Clearances for
Airflow |
10" (25.4 cm) front and 12" (30.5 cm) rear |
Minimum Cabinet Clearances for
Service |
30" (76.3 cm) front and rear, 12" top |
AC Power |
200 to 240VAC |
Current |
30A Single Phase or 3-Phase |
Weight (empty) |
307 lbs (138 kg) |
Features |
Split rear door with cable egress opening, reversible front door
(left or right handed) |
FC and FCoE Switch Support
AFF8080 EX |
AFF8060 |
AFF8040 |
AFF8020 |
NetApp offers broad support for FC and FCoE
switches. A list of switches available through NetApp can be found here.
For the complete list of supported switches, please consult the
interoperability matrix found on the NetApp support site. Login
access is required. |
|
¡D¥»¤å¥óªº¸ê°TY¦³×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ùY¦³»~¡A¥Hì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨äì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C
º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á!
ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶WÈÀu´fªºNetApp - All Flash FAS Technical Specifications - Àx¦s³]³Æ/³Æ¥÷¤è®×
,³Ì¦nªºNetApp - All Flash FAS Technical Specifications±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
|
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§ÚÌ·|¬°±z¦Vì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú̳£¥i¼u©Ê°t¦X±zªº»Ýn³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G
1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901 |
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»¶ÁʶR¸ß»ù§ÚÌ·|¥ß§Y»P±zÁpô! |
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw |
|
¥I´Ú¤è¦¡¡G¦p«È¤á¬°º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C |
¶Ç¯uq³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨qÁʵ{§Ç¡A§ÚÌ·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{q³æ¡C |
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú̦¬¨ì±zq³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C |
°e³f¤è¦¡¡G(1) ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C |
°e³f½d³ò¡G¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±zt¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C |
°â«áªA°È¡GY²£«~¥»¨·å²«©Î¹B°e¹Lµ{¾ÉP·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C |
«O©T¬Fµ¦¡G ¹ê»Ú¥Hì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C |
¤O±ô¸ê°T ServerBank Inc. ²¤¶
¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G
»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶Û¡B¥xÆWªFªÛ¡B¥xÆW^¸â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B
¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B
ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B
¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B
Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B
¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B
´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B¸ºÐ¼s¼½¡B·¼é°Û¤ù¡B®É³ø©P¥Z¡B
±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B
²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡Bì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°
¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B
ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B
¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B
¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤±]±¶¹B¡B¥xÆW´¼¼z¥d¡B
¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½^¡B¿ßÀYÆN
©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B
x¤è¡G ªÅx¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B
|
|
|
|
|
|
|