FAS8080 EX | FAS8060 | FAS8040 | FAS8020 | |
---|---|---|---|---|
NAS Scaling | 1¡V24 nodes (12 HA pairs) | |||
Maximum drives | 17,280 | 14,400 | 8,640 | 5,760 |
Maximum capacity | 138PB | 115PB | 69PB | 46PB |
Maximum Flash Pool™ capacity | 1728TB | 864TB | 576TB | 288TB |
Maximum memory | 3072GB | 1536GB | 768GB | 576GB |
SAN Scaling | 1¡V8 nodes (4 HA pairs) | |||
Maximum drives | 5,760 | 4,800 | 2,880 | 1,920 |
Maximum capacity | 46PB | 38PB | 23PB | 15PB |
Maximum Flash Pool capacity | 576TB | 288TB | 192TB | 96TB |
Maximum memory | 1024GB | 512GB | 256GB | 192GB |
Cluster interconnect | 2, 4, or 6 10GbE | 2 or 4 10GbE | 2 or 4 10GbE | 2 10GbE |
¡@
¡@ | FAS8080 EX | FAS8060 | FAS8040 | FAS8020 |
Maximum capacity | 11520TB | 9600TB | 5760TB | 3840TB |
Maximum Flash Pool capacity | 144TB | 72TB | 48TB | 24TB |
Maximum drives | 1,440 | 1,200 | 720 | 480 |
Controller form factor |
Dual enclosure HA; 2 controllers in two 6U chassis; total of 12U |
Dual-enclosure HA; 2 controllers and 2 IOXMs in two
6U chassis; total of 12U or Single-enclosure HA; 2 controllers in single 6U chassis |
Single-enclosure HA; 2 controllers in single 6U chassis |
Single-enclosure HA; 2 controllers in single 3U chassis |
Memory | 256GB | 128GB | 64GB | 48GB |
Maximum Flash Cache™ | 24TB | 8TB | 4TB | 3TB |
Maximum Flash Pool | 144TB | 72TB | 48TB | 24TB |
Combined flash total | 144TB | 72TB | 48TB | 24TB |
NVRAM | 32GB | 16GB | 16GB | 8GB |
PCIe expansion slots | 24 | 8 or 24[1] | 8 | 4 |
Onboard I/O: UTA2 (10GbE/FCoE, 16Gb FC) |
8 | 8 | 8 | 4 |
Onboard I/O: 10GbE | 8 | 8 | 8 | 4 |
Onboard I/O: GbE | 8 | 8 | 8 | 4 |
Onboard I/O: 6Gb SAS | 8 | 8 | 8 | 4 |
Storage networking supported | FC; FCoE; iSCSI; NFS; pNFS; CIFS/SMB | |||
OS version | ONTAP® 8.2.2 RC1 or higher | ONTAP 8.2.1 RC2 or higher | ||
High-availability features | Alternate Control Path (ACP); Ethernet-based service processor and ONTAP management interface; redundant hot-swappable controllers, cooling fans, power supplies, and optic | |||
¡@ |
¡@ |
|||
Supported configurations ¡@ ONTAP 9, 8.3 ¡@ |
Hardware cluster configurations:
MetroCluster configurations for synchronous replication:
Consult the Interoperability Matrix Tool for
FAS8000 support on earlier versions of ONTAP
software. |
|||
Disk shelves supported |
DS2246 (2U; 24 drives, 2.5" SFF) DS4246 (4U; 24 drives, 3.5" LFF) DS4486 (4U; 48 drives, 3.5" LFF) DS4243 (4U; 24 drives, 3.5" LFF) supported for upgrades only DS14 disk shelves (mk2-AT, mk4) are supported for upgrades only See NetApp Disk Shelves and Storage Media for more details on each disk shelf and supported drive types. |
|||
Maximum RAID group sizes |
RAID-TEC™
(triple parity, ONTAP 9)
|
|||
Operating systems supported | Windows® 2000, Windows Server® 2003, Windows Server 2008, Windows Server 2012, Windows XP, Linux®, Oracle® Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX® | |||
Max. number of LUNs |
FAS8020/FAS8040: 8,192 (ONTAP 9 and 8.3.x) FAS8060/FAS8080: 12,288 (ONTAP 9 and 8.3.x) 7-mode, all FAS8000 systems: 2048 ¡@ |
|||
Number of supported SAN hosts |
FAS8020/FAS8040: 4,096 (ONTAP 9 and 8.3.x) FAS8060/FAS8080: 8,192 (ONTAP 9 and 8.3.x) 7-mode, all FAS8000 systems: Up to 512 hosts per HA pair ¡@ |
|||
FlexVol® volumes | (In hardware clusters) Up to 1,000 per controller; (7-mode) up to 500 per controller | |||
Snapshot® copies |
Up to 255,000 per controller ¡@ |
|||
Maximum volume size | 100TB | 100TB | 100TB | 70TB |
Maximum aggregate size | 400TB | 400TB | 324TB | 324TB |
Maximum Port Count (Includes Integrated Ports and PCIe Expansion Slots) | ||||
FC target ports (16Gb autoranging) | 64 | 64 | 24 | 12 |
FC target ports (4Gb or 8Gb) | 64 | 64 | 40 | 20 |
FCoE target ports, UTA (max.) | 32 | 32 | 24 | 12 |
10GbE ports (max.) | 64 | 64 | 32 | 16 |
GbE ports (max.) | 72 | 72 | 40 | 20 |
6Gb/12Gb SAS ports (max.) | 56 | 56 | 40 | 20 |
FC initiator ports (max.) | 72 | 72 | 40 | 20 |
Maximum Adapters | ||||
Dual 10GbE (optical or copper) | 16 | 16 | 8 | 4 |
Dual 10Gbase-T (RJ-45,CAT 6A-E) | 16 | 16 | 8 | 4 |
Quad GbE (copper) | 16 | 16 | 8 | 4 |
Dual 10GbE/FCoE 16Gb FC Unified Target Adapter 2 (UTA2, optical or copper for 10GbE/FCoE deployments, optical for 16Gb FC) | 24 | 24 | 8 | 4 |
8Gb FC target | 16 | 16 | 8 | 4 |
Flash Cache Performance Acceleration Module (2TB) | 12 | 4 | 2 | 0 |
Flash Cache Performance Acceleration Module (1TB) | 24 | 8 | 4 | 2 |
Flash Cache Performance Acceleration Module (512GB) | 24 | 16 | 8 | 4 |
Quad 6Gb SAS storage HBA | 12 | 8 | 8 | 4 |
Quad 12Gb SAS storage HBA | 12 | 8 | 8 | 4 |
Quad 4Gb FC storage/tape HBA (fiber) | 16 | 8 | 8 | 4 |
¡@
¡@ |
FAS8080 EX | FAS8060 | FAS8040 | FAS8020 |
---|---|---|---|---|
Thermal Rating (at 200V) |
2,880 BTU (typical, per enclosure) 3,252 BTU (worst case, per enclosure) |
2,031 BTU (typical) 2,362 BTU (worst case) |
1,495 BTU (typical) 1,843 BTU (worst case) |
1,205 BTU (typical) 1,450 BTU (worst case) |
Weight (heaviest) | 115.08lb. | 121.47lb. | 119.49lb. | 74.08lb. |
Height | 12U (6U per enclosure) | 6U or 12U[1] | 6U | 3U |
Width | 19" IEC rack-compliant (17.6", 44.7cm) | |||
Depth | 24.3" (28.9" with cable management) | |||
Operating temperature, altitude, and relative humidity | 10¢XC to 40¢XC (50¢XF to 104¢XF); at <= 3,000m (at <= 10,000) elevation; 20% to 80% relative humidity, noncondensing (28¢XC wet bulb temperature) | |||
Nonoperating temperature and relative humidity | ¡V40¢XC to 70¢XC (¡V40¢XF to 158¢XF); 5% to 95% relative humidity, noncondensing, in original container | |||
Operating acoustic noise ¡@ |
FAS8020: ¡@
FAS8040/FAS8060: ¡@
FAS8080 EX: ¡@
|
|||
Compliance | RoHS-compliant (PDF) | |||
Safety/emissions/immunity |
Safety: EN 60950, CE, CSA 60950, UL
60950, CB IEC60950-1 (all national deviations),
EN60825-1, IRAM, CU, BIS, BSMI, SONCAP, NRCS LOA
(South Africa) Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI |
¡@
¡@ | FAS8080 EX | FAS8060 | FAS8040 | FAS8020 |
---|---|---|---|---|
Rack space | 42U | |||
Dimensions (height/width/depth) | 78.75" (200cm)/23.6" (60cm)/44.3" (112.5cm) | |||
Minimum cabinet clearances for airflow | 10" (25.4cm) front and 12" (30.5cm) rear | |||
Minimum cabinet clearances for service | 30" (76.3cm) front and rear, 12" top | |||
AC power | 200 to 240VAC | |||
Current | 30A single-phase or 3-phase | |||
Weight (empty) | 307lb. (138kg) | |||
Features | Split rear door with cable egress opening, reversible front door (left or right handed) |