­º­¶> ºô¸ô³]³Æ/ÀW¼eºÞ²z

>>ÂsÄý©Ò¦³PLANETºô¸ô³]³Æ/ÀW¼eºÞ²z

PLANET
Planet BSP-360

«¬¸¹¡GPlanet BSP-360


PLANETPlanet BSP-360


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºPLANET - Planet BSP-360 - ºô¸ô³]³Æ/ÀW¼eºÞ²z
³Ì¦nªºPLANET - Planet BSP-360±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Úºô¸ô³]³Æ/ÀW¼eºÞ²z Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óPLANET¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§PLANET²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§PLANET­ì¼t°t¥ó


¡@

¡@

¡@


PLANET
Planet BSP-360 - ServerBank¸ê°T±ÄÁʺô
Planet BSP-360
ºô¸ô³]³Æ/ÀW¼eºÞ²z


¡@
²£«~³W®æ
·s¼Wºô­¶1

Planet BSP-360

Hardware Specifications
Copper Ports LAN: 5 10/100/1000Mbps auto MDI/MDI-X RJ45 port (Port 1 to Port 5, bridge mode)
WAN: 1 10/100/1000Mbps auto MDI/MDI-X RJ45 port (Port 5, gateway mode)
¡@
PoE Injector Port 4 ports with 802.3af/802.3at PoE injector function (Port 1 to Port 4)
USB 1 USB Type A female for setting backup
Power Output 4 PoE out 51VDC; max. 30 watts per PoE port
2 DC out 24@ 1A maximum (four-pin terminal block)
* The voltage of DC out is based on the battery.
¡@
Switch Architecture Store-and-Forward
Switch Fabric 10Gbps/non-blocking
Switch Throughput@64 bytes 5.95Mpps@64 bytes
MAC Address Table 8K entries
Shared Data Buffer 512Kbit
Flow Control IEEE 802.3x pause frame for full-duplex
Back pressure for half-duplex
¡@
Reset Button < 5 sec: System reboot
> 5 sec: Factory default
¡@
LED 3 LEDs for System and Power:
¡@
  • Green: Power
    ¡@
  • Green: Fault
    ¡@
  • Green: System

4 LEDs for PoE Copper Ports (Port 1~Port 4):
¡@
  • Green: LNK/ACT
    ¡@
  • Orange: PoE-in-use

1 LED for 10/100/1000T Copper Port (Port 5):
¡@
  • Green: LNK/ACT

3 LEDs for PoE Power Usage (W)
¡@
  • Green: 50, 100 and 120W
Connector Removable 6-pin terminal block
Pin 1/2 for PV panel; Pin 3/4 for alarm; Pin 5/6 for battery
¡@
Alarm 1 Digital Output (DO):
Level 0: -24V~2.1V (¡Ó0.1V)
Level 1: 2.1V~24V (¡Ó0.1V)
Open collector to 24V DC, 100mA max.
¡@
Power Requirements PV in: 24~45V DC
Battery in/out: 24V DC
¡@
Power Consumption/ Dissipation 5.04 watts, 17.1BTU (Standby without PoE function)
6.96 watts, 23.7 BTU (Full loading without PoE function)
135.36 watts, 461.5 BTU (Full loading with PoE function)
¡@
Dimensions (W x D x H) 84 x 107 x 152 mm
Weight 1026g
ESD Protection 6KV DC
Enclosure IP30 aluminum case
Installation DIN-rail kit and wall-mount ear
Power over Ethernet
PoE Standard IEEE 802.3af/802.3at Power over Ethernet PSE
PoE Power Supply Type End-span
PoE Power Output Per port 51V DC, 275mA. Max. 15.4 watts (IEEE 802.3af)
Per port 51V DC, 535mA. Max. 30 watts (IEEE 802.3at)
¡@
Power Pin Assignment 1/2 (+), 3/6 (-)
PoE Power Budget 120 watts (PoE consumption + DC out and depending on power input)
Max. Number of Class 2 PDs 4
Max. Number of Class 3 PDs 4
Max. Number of Class 4 PDs 4
Electrical Characteristics
System Voltage Rating 24V DC
Maximum Charging Current 6A
Max. Solar Array VOC 60V DC
Max. Operating Voltage 45V DC
Total Current Consumption While operating -32mA
At idle -11mA
¡@
High Temperature Shutdown 100 degrees C disconnect solar and load
80 degrees C reconnect solar and load
¡@
Battery Charging Characteristics
Charge Algorithm Bulk charge (constant current), Absorption charge (constant voltage) and Floating charge. Absorption and Floating charge with PWM protection.
Maximum Output Current 6A
Nickel-cadmium Battery ¡Ó 40 mV/degrees Celsius for NiCad type batteries; charge cut-off @ 55 degrees C
(Temperature compensation baseline@ 25 degrees C)
¡@
Lead Acid Battery (Default Setting) ¡Ó 60 mV/degrees Celsius for lead acid type batteries; charge cut-off @ 55 degrees C
(Temperature compensation baseline@ 25 degrees C)
¡@
Float Charge Voltage DC 27.2V (26.0~30.0V)
Absorption Charge Voltage DC 29.2V (28.0~32.0V)
LVD (Low Voltage Disconnection) DC 22.2V (21.0~25.0V)
LVR (Low Voltage Reconnection) DC 24.8V (23.0~27.0V)
Router Features
Internet Connection Type Shares data and Internet access with users, supporting the following internet accesses:
¡@
  • PPPoE
    ¡@
  • Dynamic IP
    ¡@
  • Static IP
    ¡@
  • PPTP
    ¡@
  • L2TP
Firewall NAT firewall with SPI (Stateful Packet Inspection)
Built-in NAT server supporting Port Forwarding, and DMZ
Built-in firewall with IP address/MAC address/Port/ URL filtering
Supports ICMP-FLOOD, UDP-FLOOD, TCP-SYN-FLOOD filter, DoS protection
¡@
Routing Protocol Static/Dynamic (RIP1 and 2) routing
VPN Pass-through PPTP, L2TP, IPSec, IPv6
LAN Built-in DHCP server supporting static IP address distribution
Supports UPnP, Dynamic DNS
Supports IGMP Proxy
Supports 802.1d STP (Spanning Tree)
IP/MAC-based bandwidth control
¡@
Management
Management Interface Setup of system/management functions
Web firmware upgrade
SNMP trap for alarm notification of events
¡@
PoE Management Power limit by consumption and allocation
PoE admin mode
Per port power schedule
Per port power enable/disable
Power feeding priority
Current per port usage and status
Total power consumption
PD alive check
Scheduled power recycling
¡@
Battery Management Battery current usage and status
Battery capacity statistics
Low Voltage Cut-Off Protection
¡@
Standards Conformance
Regulatory Compliance FCC Part 15 Class A, CE
Standards Compliance IEEE 802.3 10BASE-T Ethernet
IEEE 802.3u 100BASE-TX Fast Ethernet
IEEE 802.3ab 1000BASE-T Gigabit Ethernet
IEEE 802.3x Flow Control and Back Pressure
IEEE 802.1D Spanning Tree Protocol
IEEE 802.3af Power over Ethernet
IEEE 802.3at Power over Ethernet Plus
RFC 768: UDP
RFC 791: IP
RFC 2068 HTTP
RFC 1157: SNMP v1
RFC 1902: SNMP v2c
RFC 5424: Syslog
¡@
Environment
Operating Temperature: -10 ~ 60 degrees C
Relative Humidity: 5 ~ 95% (non-condensing)
¡@
Storage Temperature: -10 ~ 70 degrees C
Relative Humidity: 5 ~ 95% (non-condensing)
Ordering Information
BSP-360 Industrial Renewable Energy 4-Port 10/100/1000T 802.3at PoE+ Managed Ethernet Switch

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºPLANET - Planet BSP-360 - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºPLANET - Planet BSP-360±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 ServerBank¼ö½æ¾÷ºØ
 ÀW¼e­t¸ü¥­¿Å
 2 WAN
 3 WAN
 4 WAN
 8 WAN¤Î¥H¤W
 ¾÷½c«¬¥æ´«¾¹
 ¥æ´«¾¹¼Ò²Õ
 µL½u¸ô¥Ñ¾¹
 ¤u·~¯ÅPOE¥æ´«¾¹
 ¤u·~¯Å¥æ´«¾¹
 ¤u·~¯Å¤á¥~«¬L2
 µL½u°T¸¹ÂX¥R¾¹
 ¤u·~¯ÅºôºÞ¥æ´«¾¹L2
 ¥ø·~¥æ´«¾¹
 ºÞ²z¾÷«¬
 ¤A¤Óºô¸ô¹q·½¨ÑÀ³¾¹
 ºô¸ô¥æ´«¾¹
 ¤u·~¯Å«DºôºÞ¥æ´«¾¹
 4G LTE¹h¹D¾¹
 L2 Switch
 µL½uºô¸ô±±¨î¾¹
 µL½u¼öÂI»{ÃÒ¹h¹D¾¹
 ±µ¤J¼h¥æ´«¾¹
 Wi-Fi AP
 ºôºÞ¥æ´«¾¹
 ÀW¼eºÞ²zQoS
 ¤@¯ë®à¤W«¬¥æ´«¾¹L2
 ºôºÞ¥æ´«¾¹L2
 ¤@¯ë¥æ´«¾¹L2
 L3 Switch
 L4 Switch
 PoE Switch
 ¼eÀWIP¤À¨É¾¹
 ¹q«H¯Å¸ô¥Ñ¾¹Router
 ¥ø·~¥Î¸ô¥Ñ¾¹Router
 ¦C¦L¦øªA¾¹
 §ë¼v¾÷¦øªA¾¹
 ºô¸ô¥d
 µL½uºô¸ôWLAN
 ¶°½u¾¹Hub
 µL½u°ò¦a¥x
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > ºô¸ô³]³Æ/ÀW¼eºÞ²z


PLANETPlanet BSP-360

Planet BSP-360


¼tµP¡GPLANET      >>ÂsÄýPLANET¥þ³¡²£«~
«¬¸¹¡GPlanet BSP-360



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºPLANET - Planet BSP-360 - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºPLANET - Planet BSP-360±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Úºô¸ô³]³Æ/ÀW¼eºÞ²z Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óPLANET¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§PLANET²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§PLANET­ì¼t°t¥ó


¡@

¡@

¡@


PLANET
Planet BSP-360 - ServerBank¸ê°T±ÄÁʺô
Planet BSP-360
ºô¸ô³]³Æ/ÀW¼eºÞ²z


¡@
²£«~³W®æ
·s¼Wºô­¶1

Planet BSP-360

Hardware Specifications
Copper Ports LAN: 5 10/100/1000Mbps auto MDI/MDI-X RJ45 port (Port 1 to Port 5, bridge mode)
WAN: 1 10/100/1000Mbps auto MDI/MDI-X RJ45 port (Port 5, gateway mode)
¡@
PoE Injector Port 4 ports with 802.3af/802.3at PoE injector function (Port 1 to Port 4)
USB 1 USB Type A female for setting backup
Power Output 4 PoE out 51VDC; max. 30 watts per PoE port
2 DC out 24@ 1A maximum (four-pin terminal block)
* The voltage of DC out is based on the battery.
¡@
Switch Architecture Store-and-Forward
Switch Fabric 10Gbps/non-blocking
Switch Throughput@64 bytes 5.95Mpps@64 bytes
MAC Address Table 8K entries
Shared Data Buffer 512Kbit
Flow Control IEEE 802.3x pause frame for full-duplex
Back pressure for half-duplex
¡@
Reset Button < 5 sec: System reboot
> 5 sec: Factory default
¡@
LED 3 LEDs for System and Power:
¡@
  • Green: Power
    ¡@
  • Green: Fault
    ¡@
  • Green: System

4 LEDs for PoE Copper Ports (Port 1~Port 4):
¡@
  • Green: LNK/ACT
    ¡@
  • Orange: PoE-in-use

1 LED for 10/100/1000T Copper Port (Port 5):
¡@
  • Green: LNK/ACT

3 LEDs for PoE Power Usage (W)
¡@
  • Green: 50, 100 and 120W
Connector Removable 6-pin terminal block
Pin 1/2 for PV panel; Pin 3/4 for alarm; Pin 5/6 for battery
¡@
Alarm 1 Digital Output (DO):
Level 0: -24V~2.1V (¡Ó0.1V)
Level 1: 2.1V~24V (¡Ó0.1V)
Open collector to 24V DC, 100mA max.
¡@
Power Requirements PV in: 24~45V DC
Battery in/out: 24V DC
¡@
Power Consumption/ Dissipation 5.04 watts, 17.1BTU (Standby without PoE function)
6.96 watts, 23.7 BTU (Full loading without PoE function)
135.36 watts, 461.5 BTU (Full loading with PoE function)
¡@
Dimensions (W x D x H) 84 x 107 x 152 mm
Weight 1026g
ESD Protection 6KV DC
Enclosure IP30 aluminum case
Installation DIN-rail kit and wall-mount ear
Power over Ethernet
PoE Standard IEEE 802.3af/802.3at Power over Ethernet PSE
PoE Power Supply Type End-span
PoE Power Output Per port 51V DC, 275mA. Max. 15.4 watts (IEEE 802.3af)
Per port 51V DC, 535mA. Max. 30 watts (IEEE 802.3at)
¡@
Power Pin Assignment 1/2 (+), 3/6 (-)
PoE Power Budget 120 watts (PoE consumption + DC out and depending on power input)
Max. Number of Class 2 PDs 4
Max. Number of Class 3 PDs 4
Max. Number of Class 4 PDs 4
Electrical Characteristics
System Voltage Rating 24V DC
Maximum Charging Current 6A
Max. Solar Array VOC 60V DC
Max. Operating Voltage 45V DC
Total Current Consumption While operating -32mA
At idle -11mA
¡@
High Temperature Shutdown 100 degrees C disconnect solar and load
80 degrees C reconnect solar and load
¡@
Battery Charging Characteristics
Charge Algorithm Bulk charge (constant current), Absorption charge (constant voltage) and Floating charge. Absorption and Floating charge with PWM protection.
Maximum Output Current 6A
Nickel-cadmium Battery ¡Ó 40 mV/degrees Celsius for NiCad type batteries; charge cut-off @ 55 degrees C
(Temperature compensation baseline@ 25 degrees C)
¡@
Lead Acid Battery (Default Setting) ¡Ó 60 mV/degrees Celsius for lead acid type batteries; charge cut-off @ 55 degrees C
(Temperature compensation baseline@ 25 degrees C)
¡@
Float Charge Voltage DC 27.2V (26.0~30.0V)
Absorption Charge Voltage DC 29.2V (28.0~32.0V)
LVD (Low Voltage Disconnection) DC 22.2V (21.0~25.0V)
LVR (Low Voltage Reconnection) DC 24.8V (23.0~27.0V)
Router Features
Internet Connection Type Shares data and Internet access with users, supporting the following internet accesses:
¡@
  • PPPoE
    ¡@
  • Dynamic IP
    ¡@
  • Static IP
    ¡@
  • PPTP
    ¡@
  • L2TP
Firewall NAT firewall with SPI (Stateful Packet Inspection)
Built-in NAT server supporting Port Forwarding, and DMZ
Built-in firewall with IP address/MAC address/Port/ URL filtering
Supports ICMP-FLOOD, UDP-FLOOD, TCP-SYN-FLOOD filter, DoS protection
¡@
Routing Protocol Static/Dynamic (RIP1 and 2) routing
VPN Pass-through PPTP, L2TP, IPSec, IPv6
LAN Built-in DHCP server supporting static IP address distribution
Supports UPnP, Dynamic DNS
Supports IGMP Proxy
Supports 802.1d STP (Spanning Tree)
IP/MAC-based bandwidth control
¡@
Management
Management Interface Setup of system/management functions
Web firmware upgrade
SNMP trap for alarm notification of events
¡@
PoE Management Power limit by consumption and allocation
PoE admin mode
Per port power schedule
Per port power enable/disable
Power feeding priority
Current per port usage and status
Total power consumption
PD alive check
Scheduled power recycling
¡@
Battery Management Battery current usage and status
Battery capacity statistics
Low Voltage Cut-Off Protection
¡@
Standards Conformance
Regulatory Compliance FCC Part 15 Class A, CE
Standards Compliance IEEE 802.3 10BASE-T Ethernet
IEEE 802.3u 100BASE-TX Fast Ethernet
IEEE 802.3ab 1000BASE-T Gigabit Ethernet
IEEE 802.3x Flow Control and Back Pressure
IEEE 802.1D Spanning Tree Protocol
IEEE 802.3af Power over Ethernet
IEEE 802.3at Power over Ethernet Plus
RFC 768: UDP
RFC 791: IP
RFC 2068 HTTP
RFC 1157: SNMP v1
RFC 1902: SNMP v2c
RFC 5424: Syslog
¡@
Environment
Operating Temperature: -10 ~ 60 degrees C
Relative Humidity: 5 ~ 95% (non-condensing)
¡@
Storage Temperature: -10 ~ 70 degrees C
Relative Humidity: 5 ~ 95% (non-condensing)
Ordering Information
BSP-360 Industrial Renewable Energy 4-Port 10/100/1000T 802.3at PoE+ Managed Ethernet Switch

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºPLANET - Planet BSP-360 - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºPLANET - Planet BSP-360±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@