­º­¶> Àx¦s³]³Æ/³Æ¥÷¤è®×

>>ÂsÄý©Ò¦³QSAN¼s²±Àx¦s³]³Æ/³Æ¥÷¤è®×

QSAN¼s²±
Qsan XS5212S

«¬¸¹¡GQsan XS5212S


QSAN¼s²±Qsan	XS5212S


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQSAN¼s²± - Qsan XS5212S - Àx¦s³]³Æ/³Æ¥÷¤è®×
³Ì¦nªºQSAN¼s²± - Qsan XS5212S±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óQSAN¼s²±¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§QSAN¼s²±²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§QSAN¼s²±­ì¼t°t¥ó


¡@

¡@

¡@


QSAN¼s²±
Qsan XS5212S - ServerBank¸ê°T±ÄÁʺô
Qsan XS5212S
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ

³W®æ


RAID Controller

Dual-active controller?(Model : XS5224D / XS5216D / XS5212D / XS5226D)

Single-upgradable controller (Model : XS5212S / XS5226S)

Processor

IntelR?XeonR?4-core processor?(8-core processor models are also available)

Memory
(per Controller)

DDR4 ECC 8GB, up to 128GB?(four DIMM slots, insert two DIMMs or more will boost performance)

Host Connectivity
(per Controller)

Host Card Slot 1?(optional)

  • 4 x 16Gb FC?(SFP+)?ports
  • 2 x 16Gb FC?(SFP+)?ports
  • 4 x 10GbE iSCSI?(SFP+)?ports
  • 2 x 10GbE iSCSI?(RJ45)?ports
  • 4 x 1GbE iSCSI?(RJ45)?ports

Host Card Slot 2?(optional)

  • 4 x 16Gb FC?(SFP+)?ports?(Slot 2 provides 20Gb bandwidth)
  • 2 x 16Gb FC?(SFP+)?ports?(Slot 2 provides 20Gb bandwidth)
  • 4 x 10GbE iSCSI?(SFP+)?ports?(Slot 2 provides 20Gb bandwidth)
  • 2 x 10GbE iSCSI?(RJ45)?ports
  • 4 x 1GbE iSCSI?(RJ45)?ports

Onboard

  • 2 x 10GBASE-T iSCSI ports
  • 1 x 1GbE management port

Expansion Connectivity?(per Controller)

Built-in 2 x 12Gb/s SAS wide ports?(SFF-8644)

Drive Type

XS5224 / XS5216 / XS5212

  • Mix & match 3.5¡² 2.5¡² SAS, NL-SAS, SED HDD
  • 2.5” SAS, SATA SSD?(6Gb MUX board needed for 2.5¡² SATA drives in dual controller system)

XS5226

  • 2.5¡² SAS, NL-SAS, SED HDD
  • 2.5” SAS, SATA SSD?(6Gb MUX board needed for 2.5¡² SATA drives in dual controller system)

Expansion Capabilities

Up to 10 expansion units using XD5300 series 12Gb SAS expansion enclosure
  • XD5324?(4U 24-bay, LFF)
  • XD5316?(3U 16-bay, LFF)
  • XD5312?(2U 12-bay, LFF)
  • XD5326?(2U 26-bay, SFF)

Max. Drives Supported

  • XS5224?(4U 24-bay, LFF)?: 284
  • XS5216?(3U 16-bay, LFF)?: 276
  • XS5212?(2U 12-bay, LFF)?: 272
  • XS5226?(2U 26-bay, SFF)?: 286

Dimension
(H x W x D)

19” Rackmount

  • XS5224?(4U 24-bay, LFF)?: 170.3 x 438 x 515 mm
  • XS5216?(3U 16-bay, LFF)?: 130.4 x 438 x 515 mm
  • XS5212?(2U 12-bay, LFF)?: 88 x 438 x 515 mm
  • XS5226?(2U 26-bay, SFF)?: 88 x 438 x 491 mm

Memory Protection

Cache-to-Flash module?(optional)

  • Battery backup module + Flash module?(to protect all memory capacity)
  • Super capacitor module + Flash module?(to protect up to 16GB memory per controller)

LCM?(LCD Module)

USB LCM?(optional)

Power Supply

80 PLUS Platinum, two redundant 770W?(1+1)
AC Input
100~127V????10A, 50-60Hz
200~240V????5A, 50-60Hz
DC Output
+12V????????63.4A
+5VSB??????2.0A

Fan Module

2 x hot pluggable/redundant fan modules
SOFTWARE

Storage Management

  • RAID level 0 ,1 ,0+1 ,3 ,5 ,6 ,10 ,30 ,50, 60, and N-way mirror
  • RAID EE level 5EE, 6EE, 50EE, and 60EE
  • Flexible storage pool ownership
  • Thin Provisioning (QThin) with space reclamation
  • SSD Cache (QCache1)
  • Auto Tiering (QTiering1)
  • Global, local, and dedicated hot spares
  • Write-through and write-back cache policy
  • Online disk roaming
  • Spreading RAID disks drives across enclosures
  • Background I/O priority setting
  • Instant RAID volume availability
  • Fast RAID rebuild
  • Online storage pool expansion
  • Online RAID level migration
  • Online volume extension
  • Online volume migration2
  • Auto volume rebuilding
  • Instant volume restoration
  • SED & ISE drive support
  • Video editing mode for enhanced performance
  • Disk drive health check and S.M.A.R.T. attributes
  • Storage pool parity check and media scan for disk scrubbing
  • SSD wear lifetime indicator
  • Disk drive firmware batch update

iSCSI Host Connectivity

  • Proven QSOE 2.0 optimization engine
  • CHAP & mutual CHAP authentication
  • SCSI-3 PR (Persistent Reservation for I/O fencing) support
  • iSNS support
  • VLAN (Virtual LAN) support
  • Jumbo frame (9,000 bytes) support
  • Up to 256 iSCSI targets
  • Up to 512 hosts per controller
  • Up to 1,024 sessions per controller

Fibre Channel Host Connectivity

  • Proven QSOE 2.0 optimization engine
  • FCP-2 & FCP-3 support
  • Auto detect link speed and topology
  • Topology supports point-to-point3?and loop
  • Up to 256 hosts per controller

High Availability

  • Dual-Active (Active/Active) SAN controllers
  • Cache mirroring through NTB bus
  • ALUA support
  • Management port seamless failover
  • Fault-tolerant and redundant modular components for SAN controller, PSU, FAN module, and dual port disk drive interface
  • Dual-ported HDD tray connector
  • Multipath I/O and load balancing support (MPIO, MC/S, Trunking, and LACP)
  • Firmware update with zero system downtime

Security

  • Secured Web (HTTPS), SSH (Secure Shell)
  • iSCSI Force Field to protect from mutant network attack
  • iSCSI CHAP & mutual CHAP authentication
  • SED & ISE drive support

Storage Efficiency

  • Thin Provisioning (QThin) with space reclamation
  • Auto Tiering (QTiering1) with 3 levels of storage tiers

Networking

  • DHCP, Static IP, NTP, Trunking, LACP, VLAN, Jumbo frame (up to 9,000 bytes)

Advanced Data Protection

  • Snapshot (QSnap), block-level, differential backup
    • Writeable snapshot support
    • Manual or schedule tasks
    • Up to 64 snapshots per volume
    • Up to 64 volumes for snapshot
    • Up to 4,096 snapshots per system
  • Remote Replication (QReplica)
    • Asynchronous, block-level, differential backup based on snapshot technology
    • Traffic shaping for dynamic bandwidth controller
    • Manual or schedule tasks
    • Auto rollback to previous version if current replication fails
    • Up to 32 schedule tasks per controller
  • Volume clone for local replication
  • Configurable N-way mirroring
  • Integration with Windows VSS (Volume Shadow Copy Service)
  • Instant volume restoration
  • Cache-to-Flash memory protection1
    • M.2 flash module
    • Power module: BBM (Battery Backup Module)?or SCM (Super Capacitor Module)
  • Support USB UPS and network UPS with SNMP management

Virtualization Certification

  • Server Virtualization & Clustering
  • Latest VMware vSphere certification
  • VMware VAAI for iSCSI & FC
  • Windows Server 2016, 2012 R2 Hyper-V certification
  • Microsoft ODX
  • Latest Citrix XenServer certification

Easy Management

  • USB LCM1, serial console support, online firmware update
  • Intuitive Web management UI, secured web (HTTPS), SSH (Secured Shell), LED indicators
  • S.E.S. support, S.M.A.R.T. support, Wake-on-LAN, and Wake-on-SAS

Green & Energy Efficiency

  • 80 PLUS Platinum power supply
  • Wake-on-LAN to turn on or wake up the system only when necessary
  • Auto disk spin-down

Host Operating Systems Support

  • Windows Server 2008, 2008 R2, 2012, 2012 R2, 2016
  • SLES (SUSE Linux Enterprise Server) 10, 11, 12
  • RHEL (Red Hat Enterprise Linux) 5, 6, 7
  • CentOS (Community ENTerprise Operating System) 6, 7
  • Solaris 10, 11
  • Free BSD 9, 10
  • Mac OS X 10.11 or later
WARRANTY & REGULATORY

Warranty

System : 3 years
Battery backup module : 1 year
Super capacitor module : 1 year

Regulatory

CE, FCC, BSMI, VCCI, KCC
OPERATING ENVIRONMENT

Temperature

Operating temperature : 0 to 40¢XC
Shipping temperature : -10 to 50¢XC

Relative Humidity

Operating relative humidity : 20% to 80% non-condensing
Non-operating relative humidity : 10% to 90%


¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQSAN¼s²± - Qsan XS5212S - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºQSAN¼s²± - Qsan XS5212S±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 NASºô¸ôÀx¦sÀɮצøªA¾¹
 ServerBank±ÀÂ˾÷ºØ
 ®à¤W«¬
 ¾÷¬[¦¡
 ª½¥ß¦¡
 ºÏºÐ°}¦C°t¥ó
 ¦Û°Ê¥úºÐ«þ¨©¾÷
 ¥~±µ¦¡µwºÐ
 ºÏ±a¾÷
 SDLT
 DLT
 LTO 1/2/3/4
 Ultrium I
 Ultrium II
 SAIT
 AIT
 AIT Turbo
 DAT
 DDS
 ºÏ±a´«±a¾÷Autoloader
 iSCSI¸Ñ¨M¤è®×
 iSCSIºÏºÐ°}¦C
 iSCSI¾ô±µ¾¹
 ºÏºÐ°}¦CRAID
 ServerBank±ÀÂ˾÷ºØ
 iSCSI
 iSCSI to SAS
 SATA
 SCSI-to-SCSI
 SCSI-to-IDE
 SCSI-to-SATA
 Fibre-to-SCSI
 Fibre-to-IDE
 Fibre-to-SATA
 Fibre-to-Fibre
 Fibre to SAS
 USB-to-IDE
 SATA-to-SATA
 SATA-to-IDE
 SAS
 IDE-to-IDE
 1394-to-IDE
 JBOD
 ºÏºÐ°}¦CÂd
 1394B-to-SATAII
 1394B-to PATA
 °ïÅ|¦¡Àx¦s¥~±µ²°
 SAS-to-SATA
 SAS-to-SAS
 SCSI-to-SAS
 PCIE
 USB
 IDE
 SAN¸Ñ¨M¤è®×
 ¥úÅÖ³q¹D¥æ´«¾¹
 ¥úÅÖ³q¹D¤¶­±¥d
 SAN Storage
 SAN Software
 ¥úÅÖ³q¹D¾ô±µ¾¹
 ¾É¦V¾¹director
 ¥úÅÖ¼Ò²Õ
 Àx¦sºÞ²z³nÅé
 ºÏ±aÂd
 ºÏ±a
 ¦Û°Ê´«¤ù¥úºÐ
 ÂÅ¥ú¥úºÐÂd
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > Àx¦s³]³Æ/³Æ¥÷¤è®×


QSAN¼s²±Qsan	XS5212S

Qsan XS5212S


¼tµP¡GQSAN¼s²±      >>ÂsÄýQSAN¼s²±¥þ³¡²£«~
«¬¸¹¡GQsan XS5212S



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQSAN¼s²± - Qsan XS5212S - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºQSAN¼s²± - Qsan XS5212S±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´ÚÀx¦s³]³Æ/³Æ¥÷¤è®× Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óQSAN¼s²±¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§QSAN¼s²±²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§QSAN¼s²±­ì¼t°t¥ó


¡@

¡@

¡@


QSAN¼s²±
Qsan XS5212S - ServerBank¸ê°T±ÄÁʺô
Qsan XS5212S
Àx¦s³]³Æ/³Æ¥÷¤è®×


¡@
²£«~³W®æ

³W®æ


RAID Controller

Dual-active controller?(Model : XS5224D / XS5216D / XS5212D / XS5226D)

Single-upgradable controller (Model : XS5212S / XS5226S)

Processor

IntelR?XeonR?4-core processor?(8-core processor models are also available)

Memory
(per Controller)

DDR4 ECC 8GB, up to 128GB?(four DIMM slots, insert two DIMMs or more will boost performance)

Host Connectivity
(per Controller)

Host Card Slot 1?(optional)

  • 4 x 16Gb FC?(SFP+)?ports
  • 2 x 16Gb FC?(SFP+)?ports
  • 4 x 10GbE iSCSI?(SFP+)?ports
  • 2 x 10GbE iSCSI?(RJ45)?ports
  • 4 x 1GbE iSCSI?(RJ45)?ports

Host Card Slot 2?(optional)

  • 4 x 16Gb FC?(SFP+)?ports?(Slot 2 provides 20Gb bandwidth)
  • 2 x 16Gb FC?(SFP+)?ports?(Slot 2 provides 20Gb bandwidth)
  • 4 x 10GbE iSCSI?(SFP+)?ports?(Slot 2 provides 20Gb bandwidth)
  • 2 x 10GbE iSCSI?(RJ45)?ports
  • 4 x 1GbE iSCSI?(RJ45)?ports

Onboard

  • 2 x 10GBASE-T iSCSI ports
  • 1 x 1GbE management port

Expansion Connectivity?(per Controller)

Built-in 2 x 12Gb/s SAS wide ports?(SFF-8644)

Drive Type

XS5224 / XS5216 / XS5212

  • Mix & match 3.5¡² 2.5¡² SAS, NL-SAS, SED HDD
  • 2.5” SAS, SATA SSD?(6Gb MUX board needed for 2.5¡² SATA drives in dual controller system)

XS5226

  • 2.5¡² SAS, NL-SAS, SED HDD
  • 2.5” SAS, SATA SSD?(6Gb MUX board needed for 2.5¡² SATA drives in dual controller system)

Expansion Capabilities

Up to 10 expansion units using XD5300 series 12Gb SAS expansion enclosure
  • XD5324?(4U 24-bay, LFF)
  • XD5316?(3U 16-bay, LFF)
  • XD5312?(2U 12-bay, LFF)
  • XD5326?(2U 26-bay, SFF)

Max. Drives Supported

  • XS5224?(4U 24-bay, LFF)?: 284
  • XS5216?(3U 16-bay, LFF)?: 276
  • XS5212?(2U 12-bay, LFF)?: 272
  • XS5226?(2U 26-bay, SFF)?: 286

Dimension
(H x W x D)

19” Rackmount

  • XS5224?(4U 24-bay, LFF)?: 170.3 x 438 x 515 mm
  • XS5216?(3U 16-bay, LFF)?: 130.4 x 438 x 515 mm
  • XS5212?(2U 12-bay, LFF)?: 88 x 438 x 515 mm
  • XS5226?(2U 26-bay, SFF)?: 88 x 438 x 491 mm

Memory Protection

Cache-to-Flash module?(optional)

  • Battery backup module + Flash module?(to protect all memory capacity)
  • Super capacitor module + Flash module?(to protect up to 16GB memory per controller)

LCM?(LCD Module)

USB LCM?(optional)

Power Supply

80 PLUS Platinum, two redundant 770W?(1+1)
AC Input
100~127V????10A, 50-60Hz
200~240V????5A, 50-60Hz
DC Output
+12V????????63.4A
+5VSB??????2.0A

Fan Module

2 x hot pluggable/redundant fan modules
SOFTWARE

Storage Management

  • RAID level 0 ,1 ,0+1 ,3 ,5 ,6 ,10 ,30 ,50, 60, and N-way mirror
  • RAID EE level 5EE, 6EE, 50EE, and 60EE
  • Flexible storage pool ownership
  • Thin Provisioning (QThin) with space reclamation
  • SSD Cache (QCache1)
  • Auto Tiering (QTiering1)
  • Global, local, and dedicated hot spares
  • Write-through and write-back cache policy
  • Online disk roaming
  • Spreading RAID disks drives across enclosures
  • Background I/O priority setting
  • Instant RAID volume availability
  • Fast RAID rebuild
  • Online storage pool expansion
  • Online RAID level migration
  • Online volume extension
  • Online volume migration2
  • Auto volume rebuilding
  • Instant volume restoration
  • SED & ISE drive support
  • Video editing mode for enhanced performance
  • Disk drive health check and S.M.A.R.T. attributes
  • Storage pool parity check and media scan for disk scrubbing
  • SSD wear lifetime indicator
  • Disk drive firmware batch update

iSCSI Host Connectivity

  • Proven QSOE 2.0 optimization engine
  • CHAP & mutual CHAP authentication
  • SCSI-3 PR (Persistent Reservation for I/O fencing) support
  • iSNS support
  • VLAN (Virtual LAN) support
  • Jumbo frame (9,000 bytes) support
  • Up to 256 iSCSI targets
  • Up to 512 hosts per controller
  • Up to 1,024 sessions per controller

Fibre Channel Host Connectivity

  • Proven QSOE 2.0 optimization engine
  • FCP-2 & FCP-3 support
  • Auto detect link speed and topology
  • Topology supports point-to-point3?and loop
  • Up to 256 hosts per controller

High Availability

  • Dual-Active (Active/Active) SAN controllers
  • Cache mirroring through NTB bus
  • ALUA support
  • Management port seamless failover
  • Fault-tolerant and redundant modular components for SAN controller, PSU, FAN module, and dual port disk drive interface
  • Dual-ported HDD tray connector
  • Multipath I/O and load balancing support (MPIO, MC/S, Trunking, and LACP)
  • Firmware update with zero system downtime

Security

  • Secured Web (HTTPS), SSH (Secure Shell)
  • iSCSI Force Field to protect from mutant network attack
  • iSCSI CHAP & mutual CHAP authentication
  • SED & ISE drive support

Storage Efficiency

  • Thin Provisioning (QThin) with space reclamation
  • Auto Tiering (QTiering1) with 3 levels of storage tiers

Networking

  • DHCP, Static IP, NTP, Trunking, LACP, VLAN, Jumbo frame (up to 9,000 bytes)

Advanced Data Protection

  • Snapshot (QSnap), block-level, differential backup
    • Writeable snapshot support
    • Manual or schedule tasks
    • Up to 64 snapshots per volume
    • Up to 64 volumes for snapshot
    • Up to 4,096 snapshots per system
  • Remote Replication (QReplica)
    • Asynchronous, block-level, differential backup based on snapshot technology
    • Traffic shaping for dynamic bandwidth controller
    • Manual or schedule tasks
    • Auto rollback to previous version if current replication fails
    • Up to 32 schedule tasks per controller
  • Volume clone for local replication
  • Configurable N-way mirroring
  • Integration with Windows VSS (Volume Shadow Copy Service)
  • Instant volume restoration
  • Cache-to-Flash memory protection1
    • M.2 flash module
    • Power module: BBM (Battery Backup Module)?or SCM (Super Capacitor Module)
  • Support USB UPS and network UPS with SNMP management

Virtualization Certification

  • Server Virtualization & Clustering
  • Latest VMware vSphere certification
  • VMware VAAI for iSCSI & FC
  • Windows Server 2016, 2012 R2 Hyper-V certification
  • Microsoft ODX
  • Latest Citrix XenServer certification

Easy Management

  • USB LCM1, serial console support, online firmware update
  • Intuitive Web management UI, secured web (HTTPS), SSH (Secured Shell), LED indicators
  • S.E.S. support, S.M.A.R.T. support, Wake-on-LAN, and Wake-on-SAS

Green & Energy Efficiency

  • 80 PLUS Platinum power supply
  • Wake-on-LAN to turn on or wake up the system only when necessary
  • Auto disk spin-down

Host Operating Systems Support

  • Windows Server 2008, 2008 R2, 2012, 2012 R2, 2016
  • SLES (SUSE Linux Enterprise Server) 10, 11, 12
  • RHEL (Red Hat Enterprise Linux) 5, 6, 7
  • CentOS (Community ENTerprise Operating System) 6, 7
  • Solaris 10, 11
  • Free BSD 9, 10
  • Mac OS X 10.11 or later
WARRANTY & REGULATORY

Warranty

System : 3 years
Battery backup module : 1 year
Super capacitor module : 1 year

Regulatory

CE, FCC, BSMI, VCCI, KCC
OPERATING ENVIRONMENT

Temperature

Operating temperature : 0 to 40¢XC
Shipping temperature : -10 to 50¢XC

Relative Humidity

Operating relative humidity : 20% to 80% non-condensing
Non-operating relative humidity : 10% to 90%


¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºQSAN¼s²± - Qsan XS5212S - Àx¦s³]³Æ/³Æ¥÷¤è®× ,³Ì¦nªºQSAN¼s²± - Qsan XS5212S±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@