Processor
|
| Number of processors |
4, 8, or 12 at 1.2-GHz |
|
| Architecture |
Superscalar SPARC V9, UltraSPARC III Cu
architecture |
|
| Cache per processor |
Level 1: Parity-protected 32-KB instruction
and 64-KB data on chip (single-bit errors are corrected) Level
2: 8-MB external cache |
|
| System bus |
Sun Fireplane interconnect at 9.6 GBps,
sustained |
|
Capacity
|
| Capacity |
- Up to 12 UltraSPARC III processors
- Up to 96 GB of Memory
- Up to 2x73 GB Ultra160 SCSI internal disks
- 1 integrated 160MB/s Ultra3 SCSI port
- Up to 6 PCI slots
|
|
System
|
| Main Memory |
8 GB to 96 GB |
|
| I/O |
2 integrated Gigabit Ethernet ports (66 MHz)
1 integrated 160MB/s Ultra3 SCSI port (66 MHz)
6 open 7-inch PCI slots (64 bit; one at 66 MHz, 5 at 33 MHz)
|
|
| System controller |
Integrated Ultra3 SCSI supports up to 15 SCSI
devices |
|
| Internal disk |
Two 73 GB Ultra3 SCSI internal disks |
|
| Removable media |
DVD-ROM internal drive
DDS-4 tape drive (optional) |
|
Availability
|
| Availability |
Dynamic Reconfiguration of CPU/memory boards,
hot CPU upgrades, redundant Sun Fireplane interconnect,
redundant network connections, hot-swap disks, smart fans, 2N
redundant hot-swap power supplies, hardened Operating System
Kernel, hardened I/O drivers, Systems Configuration Card,
proactive self-diagnostics, end-to-end data integrity including
ECC, and cluster support.
|
|
Resource Management
|
| Resource Management |
Solaris Resource Manager, Solaris Bandwidth
Manager |
|
Software
|
| Operating System |
Solaris 8 Operating System (2/02) or later
|
|
| Languages |
C, C++, Pascal, Fortran, Java |
|
| Networking |
ONC/NFS, TCP/IP, SunLink OSI, X.25, DCE,
NetWare |
|
| System monitoring |
Sun Management Center 3.0, Solaris Management
Console |
|
| System and network management |
Sun Cluster, Sun OpenBoot firmware, Solaris
Web Start, Solstice DiskSuite, SunScreen Secure Net, VERITAS
File System, VERITAS Volume Manager, Solaris Resource Manager,
Solaris Bandwidth Manager |
|
Environment
|
| DC power |
-48VDC or -60VDC |
|
| Operating |
5¢X C to 40¢X C (41¢X F to 104¢X F) at 5% to 85%
continuous humidity; -5¢XC to 55¢XC at 5% to 90% continuous
humidity for < 96 hours under the limits of Telcordia SR-3580
(NEBS) Level 3 |
|
| Altitude |
Up to 3,048 m (10,000 ft.) |
|
Regulations
|
| Regulations |
Meets or exceeds the following requirements:
|
|
| Safety |
North America: UL 60950 third edition, CSA
C22.2 No 60950-00 third edition (Certified: UL and UL for
Canada)
European Community: EN 60950:2000, (Certified: UL for
Germany/GS-Mark and GOST R for Russia)
Worldwide except North America: IEC 60950:1999 and CB Bulletin
(Certified: DEMKO and UL for Argentina/IRAM S-Mark)
RFI/EMI Class A: Australia/New Zealand AS/ NZ 3548, Industry
Canada ICES-003, European Community EN55022/CISPR22, Japan VCCI,
Taiwan CNS 13438, and U.S. FCC 47CFR15.B |
|
| RFI/EMI FCC Immunity |
- EN55024 (89/336/EEC)
- Telecordia GR-1089-CORE including ESD open doors (DC
only)
|
|
| Emissions |
- CFR Title 47 FCC Part 15 including 2-in-rack
- EN 55022 (89/336/EEC) including 2-in-rack
- Telcordia GR-1089-CORE including open doors (DC only)
|
|
| NEBS |
- GR-1089-CORE (EMC and Electrical Safety)
- GR-63-CORE (Physical Protection)
- SR-3580 Certification Levels
|
|
Dimensions and Weight
|
| Height |
527 mm (20.75 in.)
12 rack units |
|
| Depth |
558 mm (22 in.) excluding cable arm |
|
| Width |
445 mm (17.5 in.) |
|
| Weight |
110-132 kg (240-290 lb.) |
|
Upgrades
|
| Upgrades |
Trade-in allowances are available for the Sun
Enterprise 420R, 450, 35x0, 4x00, and Netra t 140x servers.
Older Sun servers and other vendors systems are eligible under
Suns Server Consolidation Program. For more information,
contact your local Sun sales representative or authorized Sun
reseller. |