DELL EMC Dell EMC SCv3000 Series Storage Arrays - ServerBank¸ê°T±ÄÁʺô Dell EMC SCv3000 Series Storage Arrays Àx¦s³]³Æ/³Æ¥÷¤è®×>SAN¸Ñ¨M¤è®×
¡@
Chassis format
All-in-one (dual controllers,
internal drive bays, networking
and expansion ports)
Rack size
3U
Controllers
2 hot-swappable per
chassis (active/active)
Processors
Intel® Xeon® Processor
E5-2603v4, 1.7GHz, 6 cores
Internal storage
capacity
SCv3000: 16 x 3.5¡¨
drive bays
SCv3020: 30 x
2.5¡¨ drive bays
System memory
32GB per SCv3xxx array (16GB per
controller)
Operating system
Storage Center OS (SC OS) 7.2 or
greater
Data Mobility and
Migration
Replication
Replicates with other SC Series
arrays*
Synchronous/Asynchronous via FC
or iSCSI
Per-volume QoS bandwidth
prioritization
Target/source relationships may
be one-to-many or many-to-one
Supports all SC data services on
source and target volumes
Change replication types and
topologies on demand
Supports cross-platform
replication with PS Series/EqualLogic
arrays (either direction)
Volume mobility
Live Migrate (included in base
product) enables
host-transparent data movement
among arrays; see also
Federation section
Federated multi-array
systems
Live Migrate (included in base
product) enables
host-transparent movement of
volumes among arrays
Snapshots maintained/preserved
during migration
Thin Import
Space-efficient, non-disruptive
data migration from PS Series (EqualLogic)
arrays
Thin Clones
Clone standalone volumes with
zero duplication of data
Clones maintain independent
snapshots and replication
Ideal for VDI, test/dev, other
applications that require
discrete instances of common
data
More efficient than dedupe for
database copies
Data Optimization
Auto-tiering method
Policy-based migration
based on real-time data usage,
customizable 512KB-4MB page
size.
Auto-tiering structure
Up to 3 primary (media-based)
tiers total, up to 2 SSD tiers
(write- and read-intensive SSDs)
Tiering customizations
User-defined profiles, option to
¡§pin¡¨ volumes to any tier
RAID support
RAID 0, 1, 5, 6, RAID
10, and RAID 10 DM (Dual
Mirror); any combination of RAID
levels can exist on a single
array
RAID tiering
Auto-provisions and dynamically
restripes multiple RAID levels
on the same tier; no need to
pre-allocate RAID groups
Thin provisioning
Active by default on all
volumes, operates at full
performance across all features
Thin snapshots
Records changes only, snapshots
auto-migrate to lower-cost
storage
Intelligent compression
Selectable option per volume
Applies to SSDs, HDDs or both in
hybrid configurations
HDD optimization
FastTrack moves frequently
accessed data to outer tracks
for quicker response times
¡@
Environmental
Operating Conditions
Operating
temperature: 50 - 95¢XF
(10 - 35¢XC)
Non-operating
temperature: -40 -
149¢XF (-40 - 65¢XC)
Operating humidity
ranges (non-condensing):
10% to 80% with 29¢XC (84.2¢XF)
maximum dew point
Non-operating humidity
(non-condensing): 5% to
95% with 33¢XC (91¢XF) maximum dew
point
Inlet type:
NEMA 5-15/CS22.2, n¢X42
¡@
Expansion Capacity
Supported expansion
enclosures
SCv300: 12 x 3.5¡¨ drive
bays (12Gb SAS)
SCv320: 24 x 2.5¡¨ drive bays
(12Gb SAS)
SCv360: 60 x 3.5¡¨ drive bays
(12Gb SAS)*
Maximum drive count
222 per array (internal plus
external expansion), more in
federated systems*
Max raw capacity
1PB per array*
(SSD or HDD), more in federated
systems
Storage media
SAS and NL-SAS drives; different
drive types, transfer rates and
rotational speeds can be mixed
in the same system.
SSD: write-intensive and
read-intensive drives
HDD: 15K, 10K, 7.2K RPM
Functional
Array configurations
All-flash, hybrid or HDD arrays
Storage format
Block (SAN)*
Max SAN hosts:
250
Max initiator ports:
500
Max LUN size
500TB
Max number of LUNs:
1000
Max number of snapshots:
4096
Max IOPS:
665,000*
Max IOPS (with latency
less than 1ms): 540,000*
Max IOPS (80% reads, 20%
writes): 231,000*
Max throughput (reads):
19,000 MB/s*
Max throughput (writes):
9,500 MB/s*
Management
Management interface
Browser-based (HTML 5):
Unisphere for SC (element
manager)
Unisphere Central (multi-array
management)
CloudIQ (cloud-based analytics
and monitoring)
Client application:
Dell Storage Manager
(multi-array, multi-site,
cross-platform management)
Federation
Create large multi-array systems
under unified management, with
seamless workload migration
between arrays via included Live
Migrate feature. Add arrays
non-disruptively, efficiently
utilizing their combined
capacity and performance. Volume
Advisor monitors federated
arrays to suggest optimal data
placement and load balancing.
Volume movement does not impact
snapshots or replication data
protection.*
Scripting support
Microsoft PowerShell
API
RESTful API
Host OS support
Microsoft® Windows Server®,
Novell® NetWare, SLES, VMware®,
Citrix® XenServer®, RedHat®
Third-party application
integration
VMware, Oracle, Microsoft, IBM,
OpenStack™, Symantec™, Commvault®,
Veeam®, Docker™ -- see SC Series
Management spec sheet for more
details
Coexistence with PS
Series arrays
Replication in either direction
Day-to-day management from a
single interface
Thin import: space-efficient,
non-disruptive data migration
from PS Series arrays
Certifications
VMware vSphere Metro Storage
Cluster, VMware SRM, Veritas
Storage Foundations Suite; see
Dell Storage Support Matrix for
additional certifications and
details
Reporting/alerts
Support assist (phone home),
remote diagnostics and
performance monitoring,
automated alerts, reports and
notifications, departmental
chargeback
Firmware updates
Online, non-disruptive.* Firmware
may be set to download
automatically, with option to
trigger installation manually if
desired.
Workload management
QoS, VVOLs
Network and
Expansion I/O
Front-end-network
protocols
FC, iSCSI, SAS (supports
simultaneous multiprotocol): FC
+ iSCSI or SAS + iSCSI)
Max 16Gb FC ports
8 per array (SFP+)
Max 10Gb iSCSI ports
16 SFP+ or BaseT per array
Max 12Gb SAS ports
Up to 8 12Gb SAS ports*
Management ports
2 per array (1Gb BASE-T)
Back-end expansion
protocols
12Gb SAS
Max back-end expansion
ports
8 per array
Up to 16 expansion enclosures
per array
Physical
SCv3000
Rack size: 3U
Height: 13.33
cm (5.25 inches)
Width: 44.5 cm
(17.52 inches)
Depth: 78.5 cm
(30.9 inches)
Weight at maximum
configuration: 24.22 kg
(53.4 lb)
Weight empty:
15.15 kg (33.4 lb)
SCv3020
Rack size: 3U
Height: 13.33
cm (5.25 inches)
Width: 44.5 cm
(17.52 inches)
Depth: 78.5 cm
(30.9 inches)
Weight at maximum
configuration: 24.22 kg
(53.4 lb)
Weight empty:
15.15 kg (33.4 lb)
¡@
Power
Power/wattage:
2 hot-swappable power supplies
(1378W or 1485W options
available, wattage type not
interchangeable after point of
sale)
Maximum output power:
1378W supply option: 1378 W;
1485W supply option: 1485 W
Maximum input power:
1378W supply option: 1584 W;
1485W supply option: 1688 W
Maximum input current:
1378W supply option: 16 A, 1485W
supply option: 8.8 A
Maximum inrush current:
55A for 10 ms or less
Nominal input voltage
operating range: 1378W
supply option: 100-240 VAC;
1485W supply option: 200-240 VAC
Nominal input frequency:
50/60 Hz
Maximum thermal
output/heat dissipation:
1378W option: 5,770 BTU per
hour; 1485 option: 5,760 BTU per
hour (for all-in-one base
appliance, no expansion
enclosures)
Regulatory
Product Safety, EMC and
Environmental Datasheets
Dell Regulatory Compliance Home
Page
Dell and the Environment
Data Protection
Features
Business continuity
Live Volume bi-directional
auto-failover, auto-repair*
Continuous operations, disaster
recovery, disaster avoidance
Includes third-site (tertiary)
replication options with Live
Volume Managed Replication*
Zero RTO/RPO with customizable
site failover SLAs per volume
VMware Metro Stretch Cluster
support
VMware Site Recovery Manager
Distributed sparing
No dedicated hot spares
required, all drives available
for I/O
Thin snapshots
Records changes only, snapshots
auto-migrate to lower-cost
storage
Application Consistency
Replay Manager:
Application-consistent snapshots
in Microsoft or VMware
environments
AppSync: Application-consistent
snapshots in Microsoft, VMware,
Oracle environments
Data-at-rest encryption
Self-encrypting drives (SEDs) in
SSD or HDD formats
Full Disk Encryption (FCE) based
on AES-256
Drives certified to FIPS 140-2
Level 2
Key Management Server (KMS)
options available for FIPS 140-2
Level 1, 2 and 3
External key manager
support
Gemalto¡¦s SafeNet KeySecure
k460, k250, k170v, k150v
Thales EMS 200
|
¡D¥»¤å¥óªº¸ê°TY¦³×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ùY¦³»~¡A¥Hì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨äì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C
º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á!
ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶WÈÀu´fªºDELL EMC - Dell EMC SCv3000 Series Storage Arrays - Àx¦s³]³Æ/³Æ¥÷¤è®×>
,³Ì¦nªºDELL EMC - Dell EMC SCv3000 Series Storage Arrays±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
|
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§ÚÌ·|¬°±z¦Vì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú̳£¥i¼u©Ê°t¦X±zªº»Ýn³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G
1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901 |
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»¶ÁʶR¸ß»ù§ÚÌ·|¥ß§Y»P±zÁpô! |
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw |
|
¥I´Ú¤è¦¡¡G¦p«È¤á¬°º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C |
¶Ç¯uq³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨qÁʵ{§Ç¡A§ÚÌ·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{q³æ¡C |
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú̦¬¨ì±zq³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C |
°e³f¤è¦¡¡G(1) ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C |
°e³f½d³ò¡G¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±zt¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C |
°â«áªA°È¡GY²£«~¥»¨·å²«©Î¹B°e¹Lµ{¾ÉP·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C |
«O©T¬Fµ¦¡G ¹ê»Ú¥Hì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C |
¤O±ô¸ê°T ServerBank Inc. ²¤¶
¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G
»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶Û¡B¥xÆWªFªÛ¡B¥xÆW^¸â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B
¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B
ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B
¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B
Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B
¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B
´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B¸ºÐ¼s¼½¡B·¼é°Û¤ù¡B®É³ø©P¥Z¡B
±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B
²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡Bì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°
¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B
ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B
¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B
¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤±]±¶¹B¡B¥xÆW´¼¼z¥d¡B
¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½^¡B¿ßÀYÆN
©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B
x¤è¡G ªÅx¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B
|
|
|
|
|
|
|